NON-PVC FLUID PATH PORT ACCESS INFUSION SET WITH SLIT SEPTUM INJECTION SITE
Device Facts
| Record ID | K964117 |
|---|---|
| Device Name | NON-PVC FLUID PATH PORT ACCESS INFUSION SET WITH SLIT SEPTUM INJECTION SITE |
| Applicant | Kawasumi Laboratories Co., Ltd. |
| Product Code | LJT · General Hospital |
| Decision Date | Mar 14, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.5965 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
THE NON-PVC PORT ACCESS INFUSION SET IS ROUTINELY USED TO ACCESS IMPLANTED MEDICATION PORTS FOR THE DELIVERY OF MEDICATIONS.
Device Story
Sterile, single-use winged access set; consists of needle, wings, and non-PVC tubing. Used by clinicians in hospital settings to access implanted medication ports. Device punctures port septum to establish fluid path for medication delivery. Coextruded tubing prevents fluid contact with PVC. Benefits include non-reactive fluid path for safe medication administration.
Clinical Evidence
Bench testing only. Biocompatibility testing performed on body fluid-contacting materials. Device meets USP XXII Bacterial Endotoxins Test (LAL) requirements.
Technological Characteristics
Non-PVC coextruded tubing; winged needle assembly; sterile, single-use. Materials are non-reactive. No electronic or software components.
Indications for Use
Indicated for patients requiring access to implanted medication ports for the delivery of medications, including chemotherapy, in hospital settings.
Regulatory Classification
Identification
A subcutaneous, implanted, intravascular infusion port and catheter is a device that consists of a subcutaneous, implanted reservoir that connects to a long-term intravascular catheter. The device allows for repeated access to the vascular system for the infusion of fluids and medications and the sampling of blood. The device consists of a portal body with a resealable septum and outlet made of metal, plastic, or combination of these materials and a long-term intravascular catheter is either preattached to the port or attached to the port at the time of device placement. The device is available in various profiles and sizes and can be of a single or multiple lumen design.
Special Controls
*Classification.* Class II (special controls) Guidance Document: “Guidance on 510(k) Submissions for Implanted Infusion Ports,” FDA October 1990.
Predicate Devices
- Kawasumi Laboratories Port Access Infusion Set
- Baxter Health Care Interlink Slit Septum Injection Site
Related Devices
- K974829 — NON-PVC FLUID PATH PORT ACCESS INFUSION SET (WITH AND WITHOUT INJECTION SET) · Kawasumi Laboratories Co., Ltd. · Feb 12, 1998
- K060580 — K-SHIELD PORT ACCESS INFUSION SET · Kawasumi Laboratories, Inc. · Jun 6, 2006
- K972712 — CORE RESISTANT HUBER INFUSION SETS · Icu Medical, Inc. · Oct 1, 1997
- K170881 — ISP Safety Huber Needle Infusion Set · Infusion Safety Products, Inc. · Dec 14, 2017
- K990693 — FLEXNEEDLE PLUS · Act Medical, Inc. · May 14, 1999