K981147 · Care Technologies, Inc. · LJL · Jun 9, 1998 · General Hospital
Device Facts
Record ID
K981147
Device Name
CLEAR (TM) LICE EGG REMOVER SYSTEM
Applicant
Care Technologies, Inc.
Product Code
LJL · General Hospital
Decision Date
Jun 9, 1998
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5960
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
To remove lice eggs from hair.
Device Story
Clear™ Lice Egg Remover System is a two-component kit for nit removal. Components include a glass-reinforced nylon fine-tooth comb and a non-toxic, water-based, vegetable-derived enzyme gel. The gel is applied to hair to facilitate the mechanical removal of lice eggs using the comb. The comb features a tooth spacing of 0.2 mm, designed to capture lice nits, which have a minimum width of approximately 0.3 mm. The system is intended for over-the-counter use by individuals to assist in the physical extraction of nits from hair.
Clinical Evidence
No clinical data provided; bench testing only. The device relies on physical dimensions (comb tooth spacing of 0.2 mm) relative to the known minimum width of lice nits (0.3 mm) to demonstrate efficacy.
Technological Characteristics
System consists of a glass-reinforced nylon fine-tooth comb and a water-based vegetable-derived enzyme gel. Comb tooth spacing is 0.2 mm. Mechanical removal principle. No energy source or software components.
Indications for Use
Indicated for the removal of lice eggs (nits) from human hair.
Regulatory Classification
Identification
The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated.
K981037 — CLEAR (TM) SPECIAL NIT COMB · Care Technologies, Inc. · May 22, 1998
K991958 — KLOUT SHAMPOO AND LICE COMBING PRETREATMENT KIT · Kiel Laboratories, Inc. · Aug 13, 1999
K163401 — Nix Ultra Lice Treatment Kit · Medtech Products, Inc. · Mar 21, 2017
K981250 — LICEMEISTER COMB · National Pediculosis Assoc. · May 28, 1998
Submission Summary (Full Text)
{0}------------------------------------------------
K981147
EXHIBIT 5 (06/04/98)
## 510(k) Summary
Daniel J. Manelli Submitted by: Farkas & Manelli, P.L.L.C. 2000 M Street, NW (Suite 700) Washington, DC 20036 202-261-1000
> On behalf of Care Technologies, Inc. 510(k) Submission: Clear™ Lice Egg Remover System
June 4, 1998 Date Summary Prepared:
Clear™ Lice Egg Remover System Name of device:
Predicate Devices:
Innocomb Lice Comb Innomed PD-1 Kit
Description of Device:
The product is a system consisting of two components: (a) a glass reinforced nylon fine tooth nit comb; and (b) an enzyme gel cleansing agent intended to be used together with the comb to facilitate the combing out of lice eggs (nits) from the hair. The combing aid gel is a non-toxic water based vegetable derived enzyme composition. The product is substantially equivalent to other nit removal products, including the Innocomb Lice Comb (K822421) and the Innomed PD-1 Kit (K822574).
The technological characteristics of the nit comb component are the same as other marketed products, including the predicate devices, which range from 100 to 200 microns of spacing between comb teeth (0.1 to 0.2 mm). Spacing between the teeth of the comb component is 0.2 mm. The minimum width of a lice nit adhering to a human hair is approximately 300 microns (0.3 mm).
To remove lice eggs from hair Intended use:
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird-like figure with three curved lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the bird symbol.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUN - 9 1998
Care Technologies, Incorporated C/O Mr. Daniel J. Manelli Farkas & Manelli, P.L.L.C. 2000 M Street, NW (Suite 700) 20036 Washington, DC
Re : K981147 Clear™ Lice Egg Remover System Trade Name: Regulatory Class: Unclassified Product Code: LJL Dated: March 27, 1998 Received: March 30, 1998
Dear Mr. Manelli:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions aqainst misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531
{2}------------------------------------------------
Page 2 - Mr. Manelli
through 542 of the Act for devices under the Electronic emoduct Radiation Control provisions, or other Federal laws or requlations.
This letter will allow you to begin marketing your device as described in your 510 (k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4692. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address
"http://www.fda.gov/cdrh/dsma/dsmamain ,html" .
Sincerely yours
Timothy A. Ulatowski
Director Division of Dental, Infection Control, and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure ... ......
{3}------------------------------------------------
EXHIBIT 2
1 1 of Page_
510(k) Number (if known): K981147
Clear(tm) Lice Egg Remover System Device Name:_
Indications For Use:
To remove lice eggs from hair.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Pallina Cecchini
(Division Sign-Off) Division of Dental, Infection Control, and General Hospital Devices
510(k) Number K981147
Prescription Use (Per 21 CFR 801.109) OR
Over-The-Counter Use
(Optional Format 1-2-96)
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.