FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
CFR Sub-Part
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart C—General Hospital and Personal Use Monitoring Devices
CFR Sub-Part
Subpart D—Pathology Instrumentation and Accessories
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—General Hospital and Personal Use Therapeutic Devices
CFR Sub-Part
BRZ
Set, Blood Transfusion
2
Product Code
BWJ
Locator, Acupuncture Point
2
Product Code
CAK
Microfilter, Blood Transfusion
2
Product Code
DWL
Stocking, Medical Support (To Prevent Pooling Of Blood In Legs)
2
Product Code
FMF
Syringe, Piston
2
Product Code
FMG
Stopcock, I.V. Set
2
Product Code
FMI
Needle, Hypodermic, Single Lumen
2
Product Code
FMS
Bed, Pediatric Open Hospital
2
Product Code
FMT
Warmer, Infant Radiant
2
Product Code
FMZ
Incubator, Neonatal
2
Product Code
FNG
Lift, Patient, Ac-Powered
2
Product Code
FNJ
Bed, Manual
1
Product Code
FNK
Bed, Hydraulic, Adjustable Hospital
1
Product Code
FNL
Bed, Ac-Powered Adjustable Hospital
2
Product Code
FNM
Mattress, Air Flotation, Alternating Pressure
2
Product Code
FNN
Nipple, Lambs Feeding
1
Product Code
FOD
Device, Occlusion, Umbilical
1
Product Code
FOH
Mattress, Water, Temperature Regulated
1
Product Code
FOK
Pad, Neonatal Eye
1
Product Code
FOS
Catheter, Umbilical Artery
2
Product Code
FOZ
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
2
Product Code
FPA
Set, Administration, Intravascular
2
Product Code
K
24
2692
SteadiSet Infusion Set
2
Cleared 510(K)
K
24
2763
JetCan® Pro Safety Huber Needle
2
Cleared 510(K)
K
24
3529
Solution Administration Sets
2
Cleared 510(K)
K
24
2339
Intravascular Extension Sets and Accessories
2
Cleared 510(K)
K
24
1058
Lyka® PORT Needle Free Access Device (4170Y)
2
Cleared 510(K)
K
23
4129
Ecomed Disposable Administration Sets
2
Cleared 510(K)
K
24
2126
I.V. Administration Set
2
Cleared 510(K)
K
23
2475
Disposable infusion set with needle
2
Cleared 510(K)
K
22
2766
Disposable Extension Set
2
Cleared 510(K)
K
23
2328
Insignis™ Syringe Infusion System
2
Cleared 510(K)
K
23
1707
ResQ Administration Set
2
Cleared 510(K)
K
23
0528
Extension Set
2
Cleared 510(K)
K
22
2780
LILY Extension Tube and Needleless Connector
2
Cleared 510(K)
K
23
0343
ProSeal™ Closed System Administration Set
2
Cleared 510(K)
K
22
1327
BD Alaris™ Pump Infusion Sets
2
Cleared 510(K)
K
22
1411
Surflo Winged Infusion Set
2
Cleared 510(K)
K
22
1121
Volumat Polyethylene I.V. Administration Set
2
Cleared 510(K)
K
23
0992
DJF Intravascular Administration Set
2
Cleared 510(K)
K
22
0301
Volumat Line
2
Cleared 510(K)
K
22
3645
I.V. Administration Set, I.V. Extension Set
2
Cleared 510(K)
K
22
3101
BD Secondary Infusion Set
2
Cleared 510(K)
K
22
0288
NP Medical nPulse K150 Neutral Displacement Needle Free Connector, nPulse Neutral displacement needle free connector, nPulse K150 Needle Free Connector
2
Cleared 510(K)
K
22
0312
Polyfusion IV Administration Sets
2
Cleared 510(K)
K
22
3088
BD SmartSite™ Needle-Free Connector
2
Cleared 510(K)
K
22
2889
FlowArt® Needle-Free Split Septum Valve
2
Cleared 510(K)
K
22
1069
Infusion Sets for Single Use with Needles
2
Cleared 510(K)
K
22
1075
Infusion Sets for Single Use
2
Cleared 510(K)
K
22
1078
Intravenous Needles for Single Use,Safety Intravenous Needles for Single Use
2
Cleared 510(K)
K
22
1518
NP Medical nCompass Extension Set with Stabilizing Base
2
Cleared 510(K)
K
22
0267
AMSafe NeuFlo Needleless Connector
2
Cleared 510(K)
K
21
2262
PCA Syringe Sets
2
Cleared 510(K)
K
22
1473
Flowart
2
Cleared 510(K)
K
22
1481
NeutrArt
2
Cleared 510(K)
K
21
3846
Q2 Blood Administration Sets
2
Cleared 510(K)
K
21
3588
Q2 IV Administration Sets
2
Cleared 510(K)
K
21
3004
Needle Free Connector
2
Cleared 510(K)
K
20
2437
Infusion Sets for Single Use
2
Cleared 510(K)
K
21
3778
IV Administration Set
2
Cleared 510(K)
K
21
2842
Microvolume Luer Access Device
2
Cleared 510(K)
K
21
3089
Ivenix Infusion System, LVP Epidural Administraion Set NRFit Connector
2
Cleared 510(K)
K
20
3609
Intravascular Administration Sets
2
Cleared 510(K)
K
20
2618
IV Administration Sets
2
Cleared 510(K)
K
21
0381
I.V. Administration Set
2
Cleared 510(K)
K
20
2279
Insignis Subcutaneous Needle Sets
2
Cleared 510(K)
K
20
3796
Firefly Needleless Connector
2
Cleared 510(K)
K
21
0544
Medtronic Extended infusion set
2
Cleared 510(K)
K
21
0430
Intravascular Extension Set
2
Cleared 510(K)
K
21
0217
Needleless Connector
2
Cleared 510(K)
K
20
1626
Safety Subcutaneous Infusion Set
2
Cleared 510(K)
K
20
0439
Velano ExT Extension Set
2
Cleared 510(K)
K
20
2672
Precision Delivery Infusion Set
2
Cleared 510(K)
K
20
1872
NeutrArt
2
Cleared 510(K)
K
20
0425
Female Luer Lock Cap
2
Cleared 510(K)
K
19
3088
MaxZero Extension Sets with Needle-Free Connector(s)
2
Cleared 510(K)
K
20
0661
Steripath Micro Blood Collection System
2
Cleared 510(K)
K
19
2375
Intellifuse Administration and Intellifuse Blood Administration Sets
2
Cleared 510(K)
K
19
1640
TK Intravascular Administration Set
2
Cleared 510(K)
K
19
2681
Safety scalp vein set, Scalp vein set, Blood collection needle (Scalp vein set type), Blood collection needle (Needle holder type), Safety blood collection needle (Scalp vein set type), Safety blood collection needle (Needle holder type)
2
Cleared 510(K)
K
19
2366
Intravascular Extension Sets and Accessories
2
Cleared 510(K)
K
19
1362
LifeFlow Blood System
2
Cleared 510(K)
K
19
1658
IV Sets not made with PVC
2
Cleared 510(K)
K
19
0806
Flowart
2
Cleared 510(K)
K
19
2647
neria guard Infusion Set
2
Cleared 510(K)
K
18
0739
Clearlink System Solution Set
2
Cleared 510(K)
K
19
0233
K-Shield Advantage Port Access Infusion Set (PAIS)
2
Cleared 510(K)
K
18
0843
HIgH-Flo Super26 Subcutaneous Needle Sets
2
Cleared 510(K)
K
18
2897
Velano Vascular Q2 Extension Set
2
Cleared 510(K)
K
18
1870
Infusion Sets with Precision Filter for Single Use, Precision Infusion Filter for Single Use, Extended Infusion Sets for Single Use
2
Cleared 510(K)
K
18
2545
Tamper Evident Cap with Male Luer Lock
2
Cleared 510(K)
K
18
1718
BD FlowSmart Set/MiniMed Pro-Set
2
Cleared 510(K)
K
17
3665
AMSafe Sure-Lok Needle-Free Connector
2
Cleared 510(K)
K
17
3361
IV Administration Set
2
Cleared 510(K)
K
17
3879
MiniMed Mio Advance infusion set
2
Cleared 510(K)
K
17
0595
IV Administration Sets
2
Cleared 510(K)
K
16
2812
Unomedical Comfort Subcutaneous Infusion Set, Unomedical Comfort Short Subcutaneous Infusion Set, Unomedical Neria Soft Subcutaneous Infusion Set, Medtronic Silhouette Subcutaneous Infusion Set, Medtronic Silhouette Paradigm Subcutaneous Infusion Set, Roche Accu-Chek Tender Subcutaneous Infusion Set, Asante Comfort Subcutaneous Infusion Set, Abbott Comfort Subcutaneous Infusion Set
2
Cleared 510(K)
K
17
2544
IV Fat Emulsion Administration Sets
2
Cleared 510(K)
K
17
0002
Medline Blood Collection Set
2
Cleared 510(K)
K
17
1117
Carefusion NeutraClear Needle-free connector (EL-NC1000)
2
Cleared 510(K)
K
17
1118
Carefusion NeutraClear multi-fuse Extension Set with needle-free connector(s)
2
Cleared 510(K)
K
17
1132
Carefusion NeutraClear Needle-free connector
2
Cleared 510(K)
K
16
2951
TUBETECH IV Administration Set
2
Cleared 510(K)
K
17
1957
MaxZero Extension Sets with Needless Connector
2
Cleared 510(K)
K
16
1808
Solution Set with 1.2 Micron Air Eliminating Filter
2
Cleared 510(K)
K
16
2826
Encore Neutral
2
Cleared 510(K)
K
17
1101
Closed Male Luer
2
Cleared 510(K)
K
16
2601
Infusion Set for Single Use
2
Cleared 510(K)
K
16
3160
Sterile Single-use Infusion Set
2
Cleared 510(K)
K
16
2804
Q2 Low Pressure Power Injection Extension Set
2
Cleared 510(K)
K
16
1898
Burette-type Infusion Sets for Single Use, Disposable Infusion Sets with Precision Filters, Disposable Infusion Set
2
Cleared 510(K)
K
16
1036
Hospira Extension Set, Hospira Primary Set
2
Cleared 510(K)
K
16
0007
Paclitaxel Sets
2
Cleared 510(K)
K
16
2304
Q2 Multiport IV Administration Sets and Extension Sets, Checkmate Multiport IV Administration Sets, Q2 Extension Sets
2
Cleared 510(K)
K
16
1323
Solution Set for Epidural Use
2
Cleared 510(K)
K
15
3731
LifeFlow Rapid Infusion Device (LifeFlow Device)
2
Cleared 510(K)
K
15
3440
PowerLoc MAX Power Injectable Infusion Set, SafeStep Huber Needle Set
2
Cleared 510(K)
K
16
0648
MiniMed Quick-Set® MiniMed Sure-T® MiniMed Silhouette® MiniMed Mio®
2
Cleared 510(K)
K
15
1250
Smart Set
2
Cleared 510(K)
K
16
0870
Hospira Administration Sets
2
Cleared 510(K)
K
15
0921
Orbit Infusion Set
2
Cleared 510(K)
K
16
0651
BD FlowSmart Set, MiniMed Pro-Set
2
Cleared 510(K)
K
15
3293
Extension Set
2
Cleared 510(K)
K
15
1969
Hospira Extension Sets
2
Cleared 510(K)
K
15
3158
Solution Administration Sets with 0.2 Micron Filter
2
Cleared 510(K)
K
15
2323
Disposable Infusion Needle, Safelock Disposable Infusion Needle
2
Cleared 510(K)
K
15
3257
BD FlowSmart Set, MiniMed Pro-Set
2
Cleared 510(K)
K
15
1991
Safelock Disposable Blood Collection Set, Disposable Blood Collection Set
2
Cleared 510(K)
K
15
1079
Q2 Intravenous Adminstration Sets and Extension Sets
2
Cleared 510(K)
K
15
1151
U & U Intravascular Administration Set
2
Cleared 510(K)
K
14
3446
Accu-Chek FlexLink Plus infusion set
2
Cleared 510(K)
K
14
3082
IV Administration Sets with 200(micro)m Blood Filter
2
Cleared 510(K)
K
15
0513
Imed Technology Intravascular Administration Set, Imed Technology Extension Set
2
Cleared 510(K)
K
15
0059
BD FlowSmart Set
2
Cleared 510(K)
K
15
0860
Nitroglycerin Sets with DUO-VENT Spike
2
Cleared 510(K)
K
14
3087
Hospira Blood Set
2
Cleared 510(K)
K
14
3015
Hospira Primary Sets
2
Cleared 510(K)
K
14
1285
BUSSE EXTENSION SET
2
Cleared 510(K)
K
14
2590
All Safe Huber Safety Infusion Set
2
Cleared 510(K)
K
14
2622
IV Administration
2
Cleared 510(K)
K
14
2974
Extension Sets
2
Cleared 510(K)
K
14
2433
Hospira Extension Set
2
Cleared 510(K)
K
14
0838
IV ADMINISTRATION SET WITH HAND PUMP
2
Cleared 510(K)
K
14
2367
Hospira Primary Sets
2
Cleared 510(K)
K
14
3234
MaxZero Administration Sets
2
Cleared 510(K)
K
14
1200
PADI-LOCK
2
Cleared 510(K)
K
14
2527
Extension Set with BD Q-Syte Luer Access Split Septum
2
Cleared 510(K)
K
14
2097
SELEC-3 I.V.ADMINISTRATION SET
2
Cleared 510(K)
K
14
2036
INFUSOMAT SPACE VOLUMETRIC INFUSION PUMP ADMINISTRATION SETS
2
Cleared 510(K)
K
14
2011
SOLUTION SET/EXTENSION SET
2
Cleared 510(K)
K
14
1834
SAPPHIRE ADMINISTRATION SET
2
Cleared 510(K)
K
14
0175
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
14
1306
TEVADAPTOR; CONNECTING SET W/ ULTRASITE INJECTION SITE, SPIKE PORT ADAPTOR SET W/ ULTRASITE INJECTION SITE
2
Cleared 510(K)
K
13
3351
NEXUS NIS-6P LUER ACTIVATED DEVICE
2
Cleared 510(K)
K
14
0133
INFUSET FLOW CONTROL EXTENSION SET
2
Cleared 510(K)
K
14
0311
CARESITE LUER ACCESS DEVICE
2
Cleared 510(K)
K
14
0831
MAXZERO EXTENSION SET WITH NEEDLESS CONNECTOR
2
Cleared 510(K)
K
14
0131
SUB-Q SUBCUTANEOUS TISSUE INFUSION SET
2
Cleared 510(K)
K
13
3073
CAIR DRIVE, NEUTRACLEAR
2
Cleared 510(K)
K
13
3894
SURFLO WINGED INFUSION SET WITH FILTER & NEEDLE PROTECTION (SURSHIELD)
2
Cleared 510(K)
K
13
3867
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD)
2
Cleared 510(K)
K
13
2841
ZYNO MEDICAL ADMINISTRATION SET
2
Cleared 510(K)
K
13
2880
MEDCOMP POWER INJECTABLE SAFETY HUBER NEEDLE
2
Cleared 510(K)
K
13
2734
NEUTRAL LUER ACTIVATED DEVICE (ONE-LINK NEEDLE-FREE IV CONNECTOR) AND EXTENSION SETS
2
Cleared 510(K)
K
13
2142
NERIA SOFT 90 INFUSION SET
2
Cleared 510(K)
K
13
2413
MZ1000
2
Cleared 510(K)
K
13
0879
NEXUS IV TUBING SET WITH LUER-ACCESSBILE ONE-WAY CHECK VALVE - IV PLUS
2
Cleared 510(K)
K
13
0416
NEXUS TKO-6P LUER ACTIVATED DEVICE
2
Cleared 510(K)
K
12
2404
MODEL NUMBER: RMS1-2604, RMS1-2614, RMS1-2404, RMS1-2414, RMS2-2604, RMS2-2614, RMS2-2404, RMS2-2414, RMS3-2604, RMS3-26
2
Cleared 510(K)
K
13
0023
K100 NEUTRAL DISPLACEMENT NEEDLE FREE CONNECTOR
2
Cleared 510(K)
K
13
0468
ORBIT INFUSION SET
2
Cleared 510(K)
K
12
3344
K-SHIELD ADVANTAGE PORT ACCESS INFUSION SET (PAIS)
2
Cleared 510(K)
K
12
1511
MACLIN POWER INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
12
1269
TBA
2
Cleared 510(K)
K
12
3874
INTERLINK SYSTEM BURETROL SOLUTION SETS, INTERLINK SYSTEM BURETROL SOLUTION SETS, CONTINUED, CLEARLINK SYSTEM BURETROL S
2
Cleared 510(K)
K
12
3868
INTERLINK SYSTEM LEVER LOCK CANNULA WITH CHECK VALVE, SECONDARY MEDICATION SETS, SOLUTION SETS, CONTINU-FLO SOLUTION SET
2
Cleared 510(K)
K
12
3729
VERSARATE FLOW RATE CONTROLER
2
Cleared 510(K)
K
12
1803
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
12
2686
ACCU-CHEK ULTRAFLEX INFUSION SET
2
Cleared 510(K)
K
11
3471
NIPRO HUBER INFUSION SET, EXCEL HUBER INFUSION SET
2
Cleared 510(K)
K
11
3470
NIPRO SAFE TOUCH HUBER INFUSION SET
2
Cleared 510(K)
K
11
2204
KDL DISPOSABLE INFUSION SET
2
Cleared 510(K)
K
12
0685
ZYNO MEDICAL ADMINISTRATION SET
2
Cleared 510(K)
K
12
0195
SAFETY SUBCUTANEOUS TISSUE INFUSION SET
2
Cleared 510(K)
K
12
1634
INTERLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATORY CLEARLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATOR
2
Cleared 510(K)
K
12
1092
FLOWEASE [SUBCUTANEOUS] INFUSION SET
2
Cleared 510(K)
K
12
0375
MED-RX PATIENT DELIVERY SET
2
Cleared 510(K)
K
12
1032
PRIMARY SYMBIQ SET, DITAL MICROBORE TUBING, 0.2 MICRON FILTER, NON-DEHP
2
Cleared 510(K)
K
12
1554
Q-FLO CLOSED MALE LUER CONNECTOR
2
Cleared 510(K)
K
12
0395
NERIA MULTI SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
12
0443
NEUTRAL LUER ACTIVATED DEVICE AND EXTENSION SETS WITH NEUTRAL LUER ACTIVATED DEVICE
2
Cleared 510(K)
K
12
0548
HLIC NEEDLE-LESS VALVE
2
Cleared 510(K)
K
12
0261
PPS PI PRESSURE INJECTABLE SAFETY HUBER NEEDLE WITHOUT LATERAL INJECTION SITE, PPS PI PRESSURE INJECTABLE SAFETY HUBER
2
Cleared 510(K)
K
12
0872
ASANTE CONSET AND ASANTE COMFORT SUBCUTANEOUS INFUSION SETS FOR USE WITH ASANTE PEARL INFUSION PUMPS
2
Cleared 510(K)
K
11
3398
NEXUS TKO-6, LUER-ACTIVATED DEVICE
2
Cleared 510(K)
K
11
2073
INFUSITE NEEDLELESS ACCES DEVICE (STERILE, BULK NON-STERILE) AND INFUSITE NEEDLELESS ACCESS DEVICE 'Y' ADAPTER (BULK...
2
Cleared 510(K)
K
12
0799
ARISURE NEUTRAL VALVE
2
Cleared 510(K)
K
11
3683
LIFESHIELD VISION INFUSION SET WITH PRE-PIERCED RESEAL
2
Cleared 510(K)
K
11
2799
MED-RX EXTENSION SET WITH T-CONNECTOR
2
Cleared 510(K)
K
11
2636
CYTOGUARD(TM) CLOSED LUER CONNECTOR
2
Cleared 510(K)
K
11
2512
VANISHPOINT BLOOD COLLECTION SET
2
Cleared 510(K)
K
11
2893
CLEARLINK LUER ACTIVATED VALVE, CLEARLINK SYSTEM NON-DEHP CATHETER EXTENSION SETS
2
Cleared 510(K)
K
11
1351
TRUECARE BIOMEDIX INTRAVASCULAR ADMINISTRATION SET, TRUECARE BIOMEDIX EXTENSION SET
2
Cleared 510(K)
K
10
2405
INFUSION SET FOR POWERPICC SOLO 2 CATHETER
2
Cleared 510(K)
K
10
3562
CENTURION PRESSURE INJECTABLE EXTENSION SET
2
Cleared 510(K)
K
11
1016
SAFEPORT MANIFOLD (TM) (OR STOPCOCK)
2
Cleared 510(K)
K
10
2512
RMS SUBCUTANEOUS NEEDLE SET
2
Cleared 510(K)
K
11
0282
LIGHTY DD INFUSION SET
2
Cleared 510(K)
K
10
3551
INTERLINK S / CLEARLINK SYSTEM / V-LINK LAD WITH VITALSHIELD PROTECTIVE COATING NON-DEHP CATHETER EXTENSION SET KITS,
2
Cleared 510(K)
K
10
3224
HOSPIRA PLUM INFUSION SET; HOSPIRA INFUSION SET WITH YELLOW STRIPE TUBING
2
Cleared 510(K)
K
10
0576
HIGH PRESSURE SETS-400 PSI
2
Cleared 510(K)
K
10
3344
INFUSION SETS
2
Cleared 510(K)
K
10
1368
D. HEART MEDICAL INTRAVASCULAR ADMINISTRATION SET, SAFETY ACCES DEVICE AND ACCESSORIES
2
Cleared 510(K)
K
10
0720
K-SHIELD PORT ACCESS INFUSION SET WITH HIGH PRESSURE TUBING
2
Cleared 510(K)
K
10
3165
BLOOD SAMPLING SET
2
Cleared 510(K)
K
10
2073
MED-RX TRANSFER SET, MODELS 10-1227TS, 10-1300TS, 10-1305TS AND 10-1306TS
2
Cleared 510(K)
K
10
2890
K-SHIELD SMALL VEIN INFUSION / WINGED COLLECTION SET W/ ANTI NEEDLE STICK PROTECTOR (AND MULTISAMPLE LUER ADAPTER)
2
Cleared 510(K)
K
10
1958
AMSINO I.V. ADMINISTRATION AND EXTENSION SETS
2
Cleared 510(K)
K
10
1196
ACCU-CHEK ULTRFLEX INFUSION SET
2
Cleared 510(K)
K
10
1677
HOSPIRA INFUSION BLOOD SETS
2
Cleared 510(K)
K
10
1180
GRIPPER MICRO BLUNT CANNULA, NON-CORING SAFETY NEEDLE (GRIPPER MICRO NEEDLE) MODEL: 21-3253-24, 21-3258-24, 21-3262-24,
2
Cleared 510(K)
K
10
0946
INTRAVSCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
09
3489
IN VISION-PLUS NANO WITH NEUTRAL ADVANTAGE TECHNOLOGY
2
Cleared 510(K)
K
10
0432
POLYFIN INFUSION SET, MODELS MMT-165, MMT-365, MMT-366, MMT-312S AND MMT-312L AND SOF-SET INFUSION SETS
2
Cleared 510(K)
K
10
0434
CLAVE NEUTRON
2
Cleared 510(K)
K
10
1385
DUAL LUER LOCK CAP, MODEL 2C6250
2
Cleared 510(K)
K
09
2382
NEXUS PRESSURE RATED EXTENSION SETS
2
Cleared 510(K)
K
09
3773
AMSINO I.V. ADMINISTRATION SET, AMSAFE3 I.V ADMINISTRATION SET, EXTENSION SETS
2
Cleared 510(K)
K
09
2930
NEXUS INTRAVASCULAR TUBING SETS-PRE-PIERCED
2
Cleared 510(K)
K
09
2905
AUTOSTART BURETTE
2
Cleared 510(K)
K
09
2527
NEXUS INJECTION SITE, MODEL NIS-8
2
Cleared 510(K)
K
09
3271
EXTENSION SET (STANDARDBORE TUBING), EXTENSION SET (MINIBORE TUBING), IV ADMINISTRATION SET ( STANDARD
2
Cleared 510(K)
K
09
2172
EXEL I.V. EXTENSION SET
2
Cleared 510(K)
K
09
0459
DISPOSABLE TPE INFUSION SET
2
Cleared 510(K)
K
09
0012
DISPOSABLE INFUSION SET
2
Cleared 510(K)
K
08
3687
BAIXIN INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
08
3723
A6 LUER ACCESS DEVICE
2
Cleared 510(K)
K
09
0809
MPS ACACIA POWER INJECTABLE INFUSION SET
2
Cleared 510(K)
K
09
0134
INTRAVENOUS POWER INJECTOR EXTENSION SET
2
Cleared 510(K)
K
09
0189
ANTIMICROBIAL CLAVE, MODELS AG CLAVE, AG MICROCLAVE
2
Cleared 510(K)
K
08
2806
SPINNING SPIROS, MODEL CH-2000
2
Cleared 510(K)
K
08
3482
COOK VASCULAR VITAL-JECT POWER INJECTABLE SAFETY INFUSION SET
2
Cleared 510(K)
K
08
2027
FLU-ADMIN, MODELS 60150, 60150C, 60151C, 60153C, 60160
2
Cleared 510(K)
K
08
3765
MAXGUARD ADVANCED LUER ACTIVATED DEVICE WITH ANTIMICROBIAL
2
Cleared 510(K)
K
08
3576
MISER CONTRAST MANAGEMENT SYSTEM
2
Cleared 510(K)
K
08
2818
SUBCUTANEOUS NEEDLE INFUSION SET
2
Cleared 510(K)
K
08
3472
MEDEGEN PRESSURE RATED EXTENSION SETS
2
Cleared 510(K)
K
08
1123
NEXUS I.V. NEEDLESS ACCESS CANNULA FOR INTRAVASCULAR ADMINISTRATION SETS
2
Cleared 510(K)
K
08
1210
NIPRO SAFETOUCH HUBER INFUSTION SET
2
Cleared 510(K)
K
08
2306
POWERLOC CLEAR SAFETY INFUSION SET
2
Cleared 510(K)
K
08
1361
CHEMOCLAVE CYTOTOXIC MEDICATION PREPARATION AND DELIVERY SYSTEM, MODEL, CH-XXXX
2
Cleared 510(K)
K
07
3444
TRITON MEIDCAL TMED IV-SET
2
Cleared 510(K)
K
08
0544
UNASSIGNED
2
Cleared 510(K)
K
07
3396
ANTIMICROBIAL ULTRASITE VALUE, ULTRASITE AG
2
Cleared 510(K)
K
08
0303
EZ REGULAR
2
Cleared 510(K)
K
08
1289
V-LINK ANTIMICROBIAL LUER ACTIVATED DEVICE AND EXTENSION SETS WITH V-LINK ANTIMICROBIAL LUER ACTIVATED DEVICE
2
Cleared 510(K)
K
08
1156
CADD MEDICATION CASSETTE RESERVOIR
2
Cleared 510(K)
K
08
0695
MOBILE I.V. SYSTEMS 10,20,60
2
Cleared 510(K)
K
08
0665
NOVOLET
2
Cleared 510(K)
K
08
0660
IV ADMINISTRATION SET
2
Cleared 510(K)
K
07
3050
SAFESTEP MAX POWER-INJECTABLE INFUSION SET
2
Cleared 510(K)
K
07
2375
SMARTPORT CT MP PORT ACCESS SYSTEM AND LIFEGUARD CT SAFETY INFUSION SET
2
Cleared 510(K)
K
07
2894
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD)
2
Cleared 510(K)
K
07
2576
CLEARLINK ANTIMICROBIAL LUER ACTIVATED DEVICE (LAD) AND EXTENSION SETS WITH THE CLEARLINK ANTIMICROBIAL LUER ACTIVATED
2
Cleared 510(K)
K
06
3631
POLYPERF / POLYPERF SAFE
2
Cleared 510(K)
K
07
1421
PROMEPLA INTRAVASCULAR ADMINISTRATION SET AND EXTENSION SET
2
Cleared 510(K)
K
07
2542
MAXPLUS TRU-SWAB POSITIVE DISPLACEMENT CONNECTOR
2
Cleared 510(K)
K
07
0630
HEALTH LINE INTERNATIONAL CORPORATION'S PRIMARY IV SOLUTION ADMINISTRATION SET WITH CHECK VALVE
2
Cleared 510(K)
K
07
1846
MODIFICATION TO EZ HUBER SAFETY INFUSION SET
2
Cleared 510(K)
K
07
0547
SURFLO WINGED INFUSION SET WITH FILTER AND NEEDLE PROTECTION (SURSHIELD)
2
Cleared 510(K)
K
07
0801
IMM HYPODERMIC NEEDLE SET
2
Cleared 510(K)
K
07
0362
SURFLO WINGED INFUSION SET
2
Cleared 510(K)
K
07
0430
PARADIGM QUICK-SET II AND QUICK-SET II SUBCUTANEOUS INFUSION SETS
2
Cleared 510(K)
K
07
0532
SPIROS
2
Cleared 510(K)
K
06
2308
LMT-KATH-S; LMT-KATH-I
2
Cleared 510(K)
K
06
2909
REPEATER PUMP II TUBE SETS
2
Cleared 510(K)
K
07
0189
ACCU-CHEK ULTRAFLEX INFUSION SET
2
Cleared 510(K)
K
06
1374
INTUITION INFUSION SETS
2
Cleared 510(K)
K
06
1285
SMARTSITE NEEDLE FREE VALVE ADMINISTRATION SETS
2
Cleared 510(K)
K
06
1771
EZ-CONNECT
2
Cleared 510(K)
K
06
1115
SPEEDFLOW 0.2UM FILTER, MODEL 11214; SPEEDFLOW 1.2UM FILTER, MODEL 11215; EASYDROP CONTROLLER, MODEL 11216
2
Cleared 510(K)
K
06
0488
DERMATECH IV HOLDER
2
Cleared 510(K)
K
06
0580
K-SHIELD PORT ACCESS INFUSION SET
2
Cleared 510(K)
K
06
0352
HEALTH LINE INTERNATIONAL CORPORATIONS,S IV ADMINISTRATIVE SETS
2
Cleared 510(K)
K
06
0672
ONE STICK Y EXTENSION SET AND VOLUMETER
2
Cleared 510(K)
K
06
0082
TIANJIN MEDIS DISPOSABLE INFUSION SET
2
Cleared 510(K)
K
06
0074
INTERLINK SYSTEM-T-CONNECTOR EXTENSION SET, MODEL 2N3326
2
Cleared 510(K)
K
05
3049
ALARIS SAFETY MALE LUER
2
Cleared 510(K)
K
05
3106
TEGO, MODEL D1000
2
Cleared 510(K)
K
05
3129
NEXUSTKO NEEDLELESS ACCESS DEVICE, MODEL NIS-5
2
Cleared 510(K)
K
05
2887
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD), MODEL SV-S23BL35VS
2
Cleared 510(K)
K
05
2432
MEDTRONIC MINIMED PARADIGM LEAPFROG II INFUSION SET, MODELS MMT-802S1, MMT-802L1, MMT-802S2, MMT-802L2
2
Cleared 510(K)
K
05
2252
CONTRAST MEDIA TRANSFER SETS
2
Cleared 510(K)
K
05
2722
LIFESHIELD LATEX-FREE MICROBORE EXTENSION SET, MODEL 14949 AND OTHERS
2
Cleared 510(K)
K
05
2658
SELECTFLOW - INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
05
1943
SUREFLOW SAFETY INFUSION DEVICE
2
Cleared 510(K)
K
05
1264
COMFORT AND INSET SUBCUTANEOUS INFUSION SETS FOR USE WITH ABBOTT INFUSION PUMPS
2
Cleared 510(K)
K
05
0906
VITALCARE I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
05
1437
CML 1000
2
Cleared 510(K)
K
05
1939
MAXPLUS TRU-SWAB POSITIVE DISPLACEMENT CONNECTOR
2
Cleared 510(K)
K
05
1142
ANGIODYNAMICS TUMESCENT INFUSION DEVICE
2
Cleared 510(K)
K
05
1009
HUBER CLEAR SAFETY INFUSION SET
2
Cleared 510(K)
K
05
1499
INTRAVASCULAR ADMINISTRATION SET AND EXTENSION SET
2
Cleared 510(K)
K
05
0600
MINILOC SAFETY INFUSION SET
2
Cleared 510(K)
K
04
3328
MICROFLO-SAFE SCALP VEIN SET
2
Cleared 510(K)
K
04
1495
PENTADEFLUE IV SOLUTION ADMINISTRATION SETS
2
Cleared 510(K)
K
05
0207
BD POSIFLOW POSITIVE DISPLACEMENT VALVE
2
Cleared 510(K)
K
04
3235
DRAGON HEART I.V. SET
2
Cleared 510(K)
K
04
2129
F00010 - IV GRAVITY SETWITH MALE LUER SLIP; F00027 - IV GRAVITY SET WITH MALE LUER LOCK
2
Cleared 510(K)
K
04
2666
LUTH-ALL SUB-Q NEEDLE SET
2
Cleared 510(K)
K
04
2936
SOLUTION ADMINISTRATION WITH LUER ACCESS INJECTION SITE
2
Cleared 510(K)
K
04
1861
NEXUS INTRAVENOUS TUBING SETS (NIVTS)
2
Cleared 510(K)
K
04
1490
IV ADMINISTRATION SETS WITH ULTRABLOCK UV-RESISTANT TUBING
2
Cleared 510(K)
K
04
2693
IV ADMINISTRATION SET B400 SP
2
Cleared 510(K)
K
04
2172
CLEO 90 INFUSION SET
2
Cleared 510(K)
K
04
1919
PERFUDROP AIR M-P WITH NEEDLE 20 G, MODEL 48451606
2
Cleared 510(K)
K
04
0533
EZ HUBER SAFETY INFUSION SET
2
Cleared 510(K)
K
04
2234
MODIFICATION TO: LIFTLOC SAFTEY INFUSION SET
2
Cleared 510(K)
K
04
1844
ALL SAFE HUBER SAFETY INFUSION SETS
2
Cleared 510(K)
K
04
2182
Y CLAVE CONNECTOR WITH INTEGRATED CHECK VALVE, MODEL XI-3432
2
Cleared 510(K)
K
04
1845
NEXUS PAV LUER LOCK DEVICE, MODEL NIS-4
2
Cleared 510(K)
K
04
0710
TEGO NEEDLE FREE ACCESS ACCESS DEVICE
2
Cleared 510(K)
K
04
1410
PUNCTUR-GUARD WINGED SET FOR BLOOD COLLECTION, MODEL 5118
2
Cleared 510(K)
K
04
1042
SPLIT SEPTUM INJECTION SITES
2
Cleared 510(K)
K
04
1545
CONTACT DETACH
2
Cleared 510(K)
K
04
1179
MODIFICATION TO THE NAC PLUS NEEDLELESS ACCESS CONNECTOR
2
Cleared 510(K)
K
03
2767
LILY VOLUME METERIC ADMINISTRATION SET, MODELS IB-2111 AND CIB-120ES
2
Cleared 510(K)
K
04
0636
CADD ADMINISTRATION SET WITH FLOW STOP, MEDICATION CASSETTE RESERVOIR WITH FLOW STOP AND EXTENSION SET
2
Cleared 510(K)
K
03
3290
TALON INFUSION SET, MODEL IP XXXX
2
Cleared 510(K)
K
04
0385
MULTIPORT MANIFOLD SET WITH SWABABLE VALVES, MODEL 9900
2
Cleared 510(K)
K
04
0633
CLICK-ON
2
Cleared 510(K)
K
04
0527
LOW PROFILE LUTHER SAFETY HUBER
2
Cleared 510(K)
K
03
3208
IVY DEVICES INC. IV/MEDICAL LINE STABILIZER
2
Cleared 510(K)
K
03
3892
ULTRAFLEX INFUSION SET
2
Cleared 510(K)
K
03
3301
IV ADMINISTRATION AND CONNECT SETS
2
Cleared 510(K)
K
03
3515
HUBERPRO SAFETY HUBER INFUSION SET
2
Cleared 510(K)
K
03
3576
LIFESHIELD LATEX-FREE PRIMARY IV PUMP SET DISTAL MICROBORE PATIENT LINE, CONVERTIBLE PIN, 72 INCH, WITH 2 PRESSURE
2
Cleared 510(K)
K
02
1692
CLC2000 CATHETER PATENCY DEVICE
2
Cleared 510(K)
K
03
3350
BD VACUTAINER SAFETY-LOK ADMINISTRATION SET WITH FILTER
2
Cleared 510(K)
K
03
2934
MPS ACACIA SAFEGUARD HUBER DEVICE
2
Cleared 510(K)
K
03
2484
MEDTRONIC MINIMED PARADIGM COUNTACH INFUSION SET, MODEL MMT 310
2
Cleared 510(K)
K
03
2485
MEDTRONIC MINIMED COUNTACH INFUSION SET, MODEL 313
2
Cleared 510(K)
K
03
3099
ADR THINSET INFUSION SET MODEL, 23-106, 23-109, 43-106, 43-109
2
Cleared 510(K)
K
03
2854
UNOMEDICAL MONICA INFUSION SET
2
Cleared 510(K)
K
03
2150
SAFETY-MULTIFLY
2
Cleared 510(K)
K
02
1471
MARQUETTE HUBER TRAP SAFETY INFUSION SET
2
Cleared 510(K)
K
02
0424
V SET
2
Cleared 510(K)
K
02
0419
V SET
2
Cleared 510(K)
K
03
1917
MEDTRONIC MINIMED PARADIGM POLYFIN QR, MODEL MMT 312L AND 312S
2
Cleared 510(K)
K
03
1923
ULTRASITE VALVE
2
Cleared 510(K)
K
03
1500
EXCEL PRIMARY SOLUTION SET
2
Cleared 510(K)
K
03
1783
SAFE-CONNECT DRUG DISPENSING SPIKE, MODELS SC 4020, SC 4015, SC 4010, SC 4005
2
Cleared 510(K)
K
02
3668
JMS EXTENSION SET WITH PLANECTA, PLANECTA (STAND ALONE UNIT), PLANECTA LOCK & PLANECTA ADAPTOR
2
Cleared 510(K)
K
03
1279
SURSHIELD SAFETY WINGED BLOOD COLLECTION SET
2
Cleared 510(K)
K
03
1266
SURSHIELD SAFETY WINGED INFUSION SET
2
Cleared 510(K)
K
03
1361
CADD HIGH-VOLUME ADMINISTRATION SETS WITH FLOWSTOP
2
Cleared 510(K)
K
03
0385
IV ADD-ON FILTER ADMINISTRATION SET WITH AND WITHOUT Y CONNECT OR NEEDLELESS ACCESS CONNECTOR
2
Cleared 510(K)
K
02
0189
EXEL BUTTERFLY SCALP VEIN SET
2
Cleared 510(K)
K
03
0149
MEDTRONIC MINIMED SOF-SITE INFUSION SET, MODELS MMT-359S6, MMT-359M6, MMT-359L6, MMT-359S9, MMT-359M9, AND MMT-359L9
2
Cleared 510(K)
K
03
0467
GRAVITECH TM FLOW CONTROLLER PRIMARY SET/GRAVITECH FLOW CONTROLLER EXTENSION SET
2
Cleared 510(K)
K
03
0246
VICTUS I.V. ADMINISTRATION SET, MODELS 27071 AND 27072
2
Cleared 510(K)
K
02
3917
WINGED NEEDLE SETS WITH AN ANTINEEDLE STICK PROTECTOR
2
Cleared 510(K)
K
03
0137
MEDTRONIC MINIMED SOF-SITE INFUSION SET, MODELS MMT-358S6, MMT-358M6, MMT-358L6, MMT-358S9, MMT-358M9, AND MMT-358L9
2
Cleared 510(K)
K
02
4363
NEXUS INJECTION SITE (NIS), MODEL NIS-1
2
Cleared 510(K)
K
03
0002
LIFESHIELD PRIMARY IV SET CONV. PIN. CLAVE; LF LC 5000 PLUMSET-DUAL W/CONV PIN & CAP PORT; LIFESHIELD LF MACROBORE EXT.
2
Cleared 510(K)
K
02
3769
PREPARE ADMINISTRATION SET
2
Cleared 510(K)
K
02
3595
BURETTE-IN LINE (150 ML)
2
Cleared 510(K)
K
02
3469
VICTUS I.V. ADMINISTRATION SET, MODELS 27058, 27059,27062
2
Cleared 510(K)
K
02
0533
EXEL VACULET BLOOD COLLECTION SET
2
Cleared 510(K)
K
02
3585
FLOSTAR NEEDLELESS CONNECTOR, MODEL FS3000
2
Cleared 510(K)
K
02
1565
LUTHER SAFETY HUBER NEEDLE SET
2
Cleared 510(K)
K
02
1916
HARMAC HUBER NEEDLE SAFETY DEVICE, H2984001
2
Cleared 510(K)
K
02
1080
NONCOR INFUSION SETS; NONCOR PORT INFUSION SETS
2
Cleared 510(K)
K
02
1999
GRIPPER PLUS NEEDLE
2
Cleared 510(K)
K
02
2209
ALARIS MEDICAL INFUSION SYSTEM ADMINISTRATION SETS
2
Cleared 510(K)
K
02
0926
EXTENSION SET, MODELS 1911-512
2
Cleared 510(K)
K
02
1488
SURECAN SAFETY HUBER NEEDLE INFUSION SETS
2
Cleared 510(K)
K
02
1480
EXTENSION SET LIGHT-SAFE, MODEL BC565
2
Cleared 510(K)
K
02
1530
SIMPLICITY EASY P SOFT INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE OF THE SKIN
2
Cleared 510(K)
K
02
1487
SIMPLICITY EASY ACCESS P INFUSION SET
2
Cleared 510(K)
K
02
1296
SIMPLICITY QD EASY P INFUSION SET
2
Cleared 510(K)
K
02
1395
MODIFICATION TO 30 EXTENSION SET
2
Cleared 510(K)
K
02
1216
SIMPLICTY SIMPLEX P INFUSION SET FOR USE WITH THE MINIMED PARADIGM INFUSION PUMPS
2
Cleared 510(K)
K
02
0530
EVANS SUB-Q, MODEL MC4206
2
Cleared 510(K)
K
02
1005
SIMPLICITY EASY ACCESS II INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE
2
Cleared 510(K)
K
01
3621
BD SAF-T PRN LUER ACTIVATED VALVE, MODEL 385100
2
Cleared 510(K)
K
02
0990
SIMPLICITY SOFT QD II INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE OF THE SKIN
2
Cleared 510(K)
K
02
0912
SIMPLICITY EASY SOFT INFUSION SET
2
Cleared 510(K)
K
02
0629
SIMPLICITY SIMPLEX SOFT INFUSION SET
2
Cleared 510(K)
K
01
3871
LIFEGUARD SAFETY INFUSION SET
2
Cleared 510(K)
K
01
3714
CODAN US I.V. ADMINISTRATION SET, MODEL B400 SP
2
Cleared 510(K)
K
01
3949
UNIVERSAL VIAL ACCESS SPIKE WITH NEEDLELESS CONNECTOR
2
Cleared 510(K)
K
02
0544
WING SAFE INFUSION SET 20 GA, SHS2000 SERIES; WING SAFE INFUSION SET 19 GA, SHS1900 SERIES; WING SAFE INFUSION SET 22 GA
2
Cleared 510(K)
K
01
4062
SIMPLICITY EASY ACCESS INFUSION SET
2
Cleared 510(K)
K
01
4061
SIMPLICITY STARPLUS SOFT INFUSION SET
2
Cleared 510(K)
K
01
2879
EXEL HUBER INFUSION SET WITH NEEDLELESS INJECTION SITE
2
Cleared 510(K)
K
01
3950
VENTED VIAL ACCESS DEVICE
2
Cleared 510(K)
K
01
3502
SIMPLICITY CLASSIC WING QD INFUSION SET
2
Cleared 510(K)
K
01
3394
LIFTLOC SAFETY INFUSION SET
2
Cleared 510(K)
K
01
2429
SURESET INFUSION SET, MODEL 8023
2
Cleared 510(K)
K
01
3164
SURSHIELD SAFETY WINGED BLOOD COLLECTION SET
2
Cleared 510(K)
K
01
3104
SIMPLICITY QD SOFT INFUSION SET FOR USE BY PEOPLE WITH DIABETES IN INFUSE INSULIN SUBCUTANEOUSLY FROM A PUMP OR SYRINGE
2
Cleared 510(K)
K
01
1405
EXEL INJECTION PLUG WITH CAP
2
Cleared 510(K)
K
01
2845
SIMPLICITY SOFT QD MICRO INFUSION SET
2
Cleared 510(K)
K
01
2526
BIOTEQUE SCALP VEIN SET
2
Cleared 510(K)
K
01
1888
PRESSURE ACTIVATED CHECK VALVE
2
Cleared 510(K)
K
01
0404
EXEL I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
01
2754
EZ SET INFUSION SET
2
Cleared 510(K)
K
01
2330
SIMPLICITY EURO QD INFUSION SET
2
Cleared 510(K)
K
01
1928
HYDROTOWER ARTHROSCOPIC ADMINISTRATION TUBING SET, MODEL 7-460-05
2
Cleared 510(K)
K
01
1216
PVC FREE INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
00
3254
CORTEZ NEEDLE FREE IV CONNECTOR, MODEL MMD-001
2
Cleared 510(K)
K
01
0888
SIDEPORT PINCH CLAMP DEVICE
2
Cleared 510(K)
K
01
1858
INTERLINK THREADED LOCK CANNULA
2
Cleared 510(K)
K
01
1187
SIMPLICITY SOFT YP INFUSION SET FOR USE WITH THE MINIMED PARAGIGM INFUSION PUMPS
2
Cleared 510(K)
K
01
1336
PRIMARY SOLUTION SET WITH UNIVERSAL SPIKE, INJECTION SITE AND MALE LUER LOCK
2
Cleared 510(K)
K
01
1193
NAC PLUS NEEDLELESS ACCESS CONNECTOR
2
Cleared 510(K)
K
01
1071
PARADIGM QUICK-SET INFUSION SET
2
Cleared 510(K)
K
01
1580
SIMPLICITY SOFT QD SILVER INFUSION SET
2
Cleared 510(K)
K
01
0279
MEDISYSTEMS LUER ACCESS INJECTION SITE
2
Cleared 510(K)
K
01
0197
EXEL SECURE TOUCH SAFETY (P.S.V.) SCALP VEIN SET
2
Cleared 510(K)
K
01
1120
GLUCOPRO INFUSION SET, MODEL GPISXXXXXXXX SERIES
2
Cleared 510(K)
K
01
0886
SIMPLICITY WING INFUSION SET
2
Cleared 510(K)
K
01
1003
SAFESTING AND SAFESTING HUB
2
Cleared 510(K)
K
01
0788
SIMPLICITY SOFT QD EASY INFUSION SET
2
Cleared 510(K)
K
01
0676
SIMPLICITY WINGED QD INFUSION SET
2
Cleared 510(K)
K
01
0647
SIMPLICITY INFUSER INFUSION SET
2
Cleared 510(K)
K
01
0846
SIMPLICITY SILVER SET SOFT INFUSION
2
Cleared 510(K)
K
00
0592
UNOLOK PLUS INFUSION SET AND VAKU-8 PLUS BLOOD COLLECTION SET
2
Cleared 510(K)
K
01
0538
PARSET NEEDLELESS PRIMARY SET FOR BLUNT CANNULA, A10003E, PARSET NEEDLELESS SECONDARY SET WITH BLUNT CANNULA, A14003E
2
Cleared 510(K)
K
01
0103
SURSHIELD WINGED INFUSION SET
2
Cleared 510(K)
K
01
0373
SIMPLICITY SOFT Y INFUSION SET FOR USE WITH THE MINIMED INFUSION PUMPS AND MINIMED MEDICATION RESERVOIRS (MODEL MMT-103)
2
Cleared 510(K)
K
00
2689
SWABSITE SWABBABLE VALVE, MODEL 245000
2
Cleared 510(K)
K
00
3977
DISETRONIC RAPID SUBCUTANEOUS INFUSION SET AND DISTERONIC RAPID D SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
00
1329
INTRAVASCULAR IV SET, IV SET WITH BURETTE, EXTENSION SET
2
Cleared 510(K)
K
00
3854
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
00
3513
TAXOL ADMINISTRATION SET
2
Cleared 510(K)
K
00
2449
BIOTEQ I.V. (INTRAVENOUS) SET
2
Cleared 510(K)
K
00
3283
SIMPLICITY WITH WINGS INFUSION SET, (MODEL MMT-103)
2
Cleared 510(K)
K
00
1233
ACTI-FLEX FLUID DELIVERY SYSTEM OR ACTI-FLEX F D S
2
Cleared 510(K)
K
00
2492
SIMPLICITY SOFT INFUSION SET
2
Cleared 510(K)
K
00
3225
SOLUTION ADMINISTRATION SETS WITH CAPLESS LUER ACTIVATED VALVE
2
Cleared 510(K)
K
00
2471
JETCAN HUBER NEEEDLE SET
2
Cleared 510(K)
K
00
1599
ACTI-FLEX IV ADMINISTRATION SET
2
Cleared 510(K)
K
00
1872
I.V. SET-LUER LOCK WITH LATEX FREE INJECTION SITE, MODEL B411
2
Cleared 510(K)
K
00
2138
PARADIGM SILHOUETTE, MODELS MMT-377, 378, 379, 380
2
Cleared 510(K)
K
00
1827
PARADIGM SOF-SET MICRO QR, MODELS 324 AND 325
2
Cleared 510(K)
K
00
1832
PARADIGM SOF-SET ULTIMATE QR, MODELS 317 AND 318
2
Cleared 510(K)
K
00
1106
MASTERSITE NEEDLELESS LUER ACTIVATED IV CONNECTOR, MODEL MS 1000
2
Cleared 510(K)
K
00
2006
LIFESHIELD ADDITIVE PIERCING PIN
2
Cleared 510(K)
K
00
1426
KAWASUMI LABORATORIES IV ADMINISTRATION SET WITH FILTER
2
Cleared 510(K)
K
00
1423
KAWASUMI LABORATORIES IV ADMINISTRATION SET, PRIMARY
2
Cleared 510(K)
K
00
1424
KAWASUMI LABORATORIES IV ADMINISTRATION SET, STANDARD
2
Cleared 510(K)
K
99
0331
SURGEN VALVE
2
Cleared 510(K)
K
00
0472
POSI-LINK
2
Cleared 510(K)
K
00
0942
CADD CHECKVALVE ADMINISTRATION SET, MODEL 21-7090
2
Cleared 510(K)
K
00
1102
PARSET PRIMARY SET WITH CHECK VALVE, MODEL A10002E
2
Cleared 510(K)
K
99
4429
VENUSA, LTD. EXTENSION SET WITH FILTER
2
Cleared 510(K)
K
00
0343
NAC Y-ADP
2
Cleared 510(K)
K
00
0152
KIPPMED I.V. MANIFOLD
2
Cleared 510(K)
K
99
2290
EXEL INJECTION PLUG WITH CAP
2
Cleared 510(K)
K
00
0017
PARSET SECONDARY ADMINISTRATION SET, LUERLOCK, MODEL A14001E, PARSET SECONDARY SECONDARY ADMINISTRATION SET, MODEL A1400
2
Cleared 510(K)
K
99
3848
MILLENNIUM HUBER PLUS SAFETY INFUSION SET
2
Cleared 510(K)
K
99
3463
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
99
3187
SHELLY PROTECTED AV FISTULA NEEDLE
2
Cleared 510(K)
K
99
2999
DAISY PROTECTED SCALP VEIN SET
2
Cleared 510(K)
K
99
3147
DECAP
2
Cleared 510(K)
K
99
2266
IV ADMINISTRATION SET
2
Cleared 510(K)
K
99
2145
ECOMED SCALP VEIN SET
2
Cleared 510(K)
K
99
2268
NAC PRN NEEDLELESS ACCESS CONNECTOR
2
Cleared 510(K)
K
99
2072
BOLUS ACCESSORY SET
2
Cleared 510(K)
K
99
1979
SOF-SET MICRO QR INFUSION SET, MODELS 320 AND 321
2
Cleared 510(K)
K
99
1112
SAGE CONTRAST MANAGEMENT SYSTEM
2
Cleared 510(K)
K
99
0777
MED-RX EXTENSION SETS
2
Cleared 510(K)
K
99
2104
PARSET, MODEL A10001E
2
Cleared 510(K)
K
99
1985
COOK HIGH VOLUME INFUSION ADAPTER INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
99
1932
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
98
4569
AB2 MED-FLO SOLUTION SET
2
Cleared 510(K)
K
98
4060
LUER ACCESS INJECTION SITE
2
Cleared 510(K)
K
99
0496
ANESFLOW-DUAL DRIP IV INFUSION SET
2
Cleared 510(K)
K
99
1759
MAERSK MEDICAL CONTOUR INFUSION SET
2
Cleared 510(K)
K
99
1653
INVISION-PLUS INJECTION PORT CONNECTOR SYSTEM
2
Cleared 510(K)
K
99
1513
HOMEPUMP C-SERIES AND HOMEPUMP C-SERIES ONE-STEP KVO
2
Cleared 510(K)
K
99
1599
CADD ADMINISTRATION SET
2
Cleared 510(K)
K
99
1301
CADD-PRIZM HIGH VOLUME ADMINISTRATION SET WITH 1.2 U FILTER AND ADD-ON ANTI-SIPHON VALVE, CADD ADMINISTRATION SET WITH 1
2
Cleared 510(K)
K
99
1255
CADD-TPN ADMINISTRATION SET, MODEL 21-7071
2
Cleared 510(K)
K
99
0693
FLEXNEEDLE PLUS
2
Cleared 510(K)
K
99
0388
TUTOPLUS IV ADMINISTRATION SET
2
Cleared 510(K)
K
98
2098
TUTODROP 1 AND TUTODROP 2
2
Cleared 510(K)
K
99
0288
FREE FLOW SAFETY DEVICE, MODEL MG 245052
2
Cleared 510(K)
K
98
4441
KVO CHECK VALVE ACCESSORY, MODEL EV-0001
2
Cleared 510(K)
K
98
4381
BURETROL SOLUTION SETS
2
Cleared 510(K)
K
99
0083
CADD ADMINISTRATION SET, CADD 250ML FLEXIBLE MEDICATION RESERVOIR, MODIFIED SECURIT SHELL, SECURITY SHELL ADAPTER
2
Cleared 510(K)
K
98
4638
PARAGON BOLUS ACCESSORY SET
2
Cleared 510(K)
K
98
4146
PARAGON INFUSION
2
Cleared 510(K)
K
98
4063
PARAGON BASAL/BOLUS ADMINISTRATION SET
2
Cleared 510(K)
K
98
3411
COLORVEES IV SET 20 DROPS/ML 105, 60 DROPS/ML 105, VENTED 20 DROPS 105, VENTED 60 DROPS 105
2
Cleared 510(K)
K
98
4561
SUBCUTANEOUS INFUSION SETS, MSR MODEL A & B
2
Cleared 510(K)
K
98
3926
MPS GRAVITY FLOW CONTROL SET
2
Cleared 510(K)
K
98
3217
ROWE DUAL-CHECK VALVE
2
Cleared 510(K)
K
98
3073
I.V. EXTENSION SET OR I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
98
2672
COLLEAGUE PUMP SYRINGE ADAPTER SET
2
Cleared 510(K)
K
98
2587
MPS FIXED FLOW RATE SET
2
Cleared 510(K)
K
98
1792
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
98
1683
HUBER NEEDLE INFUSION SET MODEL #20G01 & Y-SITE MODEL #20G01Y
2
Cleared 510(K)
K
98
2123
CONTRAST CONTROL DEVICE
2
Cleared 510(K)
K
98
2047
MPS HUBER NEEDLE EXTENSION SET
2
Cleared 510(K)
K
98
1386
MANAN BLUNT NEEDLE
2
Cleared 510(K)
K
98
1548
NFC NEEDLEFREE CONNECTOR MODEL 69900
2
Cleared 510(K)
K
98
1547
NFC NEEDLEFREE Y-SITE, MODEL 69970
2
Cleared 510(K)
K
98
1157
STABLE FLOW
2
Cleared 510(K)
K
98
0994
IV ADMINISTRATION SETS WITH NEEDLE ACCESS DEVICES
2
Cleared 510(K)
K
98
0992
IV ADMINISTRATION SETS WITH NEEDLELESS ACCESS DEVICES
2
Cleared 510(K)
K
97
4571
SOLUTION ADMINISTRATION SET WITH CAPPED LUER ACTIVATED VALVE
2
Cleared 510(K)
K
98
0583
EXTENSION SET WITH 0.2U FILTER AND ANTI-SIPHON VALVE CADD ADMINISTRATION SET WITH 0.2U FILTER AND ANTI-SIPHON VALVE
2
Cleared 510(K)
K
98
1318
DUAL LUER LOCK CAP
2
Cleared 510(K)
K
98
0127
6 INCH MINI-BONE EXTENSION SET WITH LUER LOCK, NES01S, 6 INCH MIN-BONE EXTENSION SET WITH LUER SLIP, NES02S, 6 INCH STAT
2
Cleared 510(K)
K
97
3916
NP MEDICAL CAPLESS LUER ACTIVATED VALVE
2
Cleared 510(K)
K
97
4163
MINIMED SOF-SET ULTIMATE QR INFUSION SET MODELS 315 AND 316
2
Cleared 510(K)
K
97
1844
MCKINLEY OUTBOUND-2 SYSTEM
2
Cleared 510(K)
K
97
4589
SMARTVALVE
2
Cleared 510(K)
K
97
4145
V3 VALVE
2
Cleared 510(K)
K
97
4013
EXTENSION SET WITH MICROBORE TUBING, EXTENSION SET WITH MICROBORE TUBING AND 0.2 U FILTER, EXTENSION SET WITH MICROBORE
2
Cleared 510(K)
K
97
2854
PROTOS I.V. ADMINISTRATION SET (15 DROPS/ML) I4070S/(60 DROPS/ML)I4670S PRELIMINARY
2
Cleared 510(K)
K
97
2839
PROTOS 100ML BURETTE INFUSION SET/ PROTOS 150ML BURETTE INFUSION SET
2
Cleared 510(K)
K
96
3659
EXEL I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
97
3167
POSITIVE PRESSURE CONNECTOR
2
Cleared 510(K)
K
97
3107
AMSINO I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
97
1004
MEDCORP FLOW I.V. REGULATOR EXTENSION SET
2
Cleared 510(K)
K
97
2712
CORE RESISTANT HUBER INFUSION SETS
2
Cleared 510(K)
K
97
2957
SA-EF MULTI-LUMEN EXTENSION SET
2
Cleared 510(K)
K
97
2527
PHASEAL, SYSTEM FOR SEALED HANDLING OF CHEMOTHERAPEUTIC AGENTS
2
Cleared 510(K)
K
97
2493
NIPRO DISPOSABLE SOLUTION INFUSION SET
2
Cleared 510(K)
K
97
1624
DYE STOP AND SAVE - QUICKFILL
2
Cleared 510(K)
K
97
2663
SMART SET
2
Cleared 510(K)
K
97
2135
MAERSK MEDICAL PURELINE COMFORT SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
97
1500
ACCESS SYSTEMS NEEDLELESS VIAL ADAPTER
2
Cleared 510(K)
K
96
4439
NEEDLE-FREE VALVED CONNECTOR AND CAP
2
Cleared 510(K)
K
97
1293
LIFESHIELD PRIMARY I.V. SET WITH BACKCHECK VALVE
2
Cleared 510(K)
K
97
0855
CLAVE CONNECTOR
2
Cleared 510(K)
K
96
5027
VENTED I.V. SET
2
Cleared 510(K)
K
97
1701
CONTINU-FLO SOLUTION SET
2
Cleared 510(K)
K
96
4067
GORE IRRIGATION SET
2
Cleared 510(K)
K
97
1066
TAMARYN I.V. FLOW REGULATOR EXTENSION SET
2
Cleared 510(K)
K
97
0909
SAFE-CONNECT I.V. SET
2
Cleared 510(K)
K
97
1266
SAFE-CONNECT Y-SITE ADAPTER CATALOG NO. 681518
2
Cleared 510(K)
K
97
0524
SAFE-CONNECT I.V. EXTENSION SET
2
Cleared 510(K)
K
97
0485
SMARTSITE ACCESS PIN
2
Cleared 510(K)
K
97
0255
KIPP MED I.V. MANIFOLD
2
Cleared 510(K)
K
96
4918
NIMA NEEDLELESS INJECTIONSITE MASTER ADAPTER WITH POSIFLOW POSITIVE DISPLACEMENT FEATURE, AND I.V. SETS
2
Cleared 510(K)
K
97
0259
E-Z SET INFUSION SET/SAF-T E-Z SET INFUSION SET
2
Cleared 510(K)
K
97
0800
MAXCESS NEEDLEFREE - Y- SITE (100713)
2
Cleared 510(K)
K
97
0438
INTERLINK MICRO-INFUSION MANIFOLD EXTENSION SETS
2
Cleared 510(K)
K
97
0076
NIPRO DISPOSABLE SOLUTION INFUSION SET
2
Cleared 510(K)
K
96
4844
CONMED: STAT 2 AND STAT 2 PUMPETTE EXTENSION SETS AND MASTERFLOW AND MASTERFLOW PUMPETTE PRIMARY SETS
2
Cleared 510(K)
K
96
4876
SA.EF(TM) INFUSION PORT II - CONNECTOR AND EXTENSION SET
2
Cleared 510(K)
K
96
4968
MR EXTENSION SET (001)
2
Cleared 510(K)
K
96
4850
SOLUTION ADMINISTRATION SET WITH 0.22 MICRON HIGH PRESSURE EXTENDED LIFE FILTER
2
Cleared 510(K)
K
96
3981
VYGON BIONECTOR WITH EXTENSION SET
2
Cleared 510(K)
K
96
4812
NIMA NEEDLELESS INJECTIONSITE MASTER ADAPTER AND I.V. SET
2
Cleared 510(K)
K
96
4456
POLYFIN QR WITH WINGS INFUSION SETS, MODELS 365, 366, AND 367
2
Cleared 510(K)
K
96
4455
POLYFIN WITH WINGS INFUSION SETS, MODELS 306, 307, 333
2
Cleared 510(K)
K
96
4384
MODEL D-290P ADMINISTRATION SET
2
Cleared 510(K)
K
96
0771
SLAV AND SLAV-ONE INJECTION PORT CONNECTOR SYSTEM
2
Cleared 510(K)
K
95
5775
SAFECONNECT VALVE (CATALOG NO. XXXX)
2
Cleared 510(K)
K
96
3112
MMG MULTI LUMON EXTENSION SET
2
Cleared 510(K)
K
96
0431
PRESSURE STOPCOCK/MANIFOLD
2
Cleared 510(K)
K
96
3009
DELTEC SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
96
2893
INTERLINK ADAPTER FOR CONVENTIONAL Y-SITE
2
Cleared 510(K)
K
96
1049
FLEX NEEDLE
2
Cleared 510(K)
K
96
1928
BIOMEDIX I.V. EXTENSION LINE W/ STOPCOCK MODEL B50-102/B51-102
2
Cleared 510(K)
K
96
3070
VENIPUNCTURE KIT
2
Cleared 510(K)
K
96
2802
SAFE MATE I.V. FLUID DELIVERY SETS
2
Cleared 510(K)
K
96
2801
SAFE MATE I.V. EXTENSION SETS
2
Cleared 510(K)
K
96
1794
FLUID ADMINISTRATION SET - CONTRAST MANAGER
2
Cleared 510(K)
K
95
5821
I.V. ADMINISTRATION SETS
2
Cleared 510(K)
K
96
0391
STRATO/INFUSAID PERIPORT INFUSION SET 41770,41771
2
Cleared 510(K)
K
96
1495
HUBER NEEDLE EXTENSION SET WITH STANDARD Y-INJECTION SITE, INTERLINK Y-INJECTION SITE, INTERLINK T-INJECTION SITE
2
Cleared 510(K)
K
96
1225
CONTINUFLO SOLUTION SET/SECONDARY MEDICATION SET
2
Cleared 510(K)
K
95
4283
ENERGIZED CONTAINER SYSTEM (MODIFICATION)
2
Cleared 510(K)
K
96
1327
BEC NEEDLELESS INJECTION SITE
2
Cleared 510(K)
K
95
5585
V2 INJECTION SITE
2
Cleared 510(K)
K
96
1474
POLYFIN INFUSION SET MMT-106/MMT-107/MMT-133
2
Cleared 510(K)
K
95
5410
SNAPDOSE DEVICE
2
Cleared 510(K)
K
95
4883
FREE FLOW SAFETY DEVICE
2
Cleared 510(K)
K
96
0280
IVAC NEEDLE FREE VALVE ADMINISTRATION SETS
2
Cleared 510(K)
K
96
0661
MAXCESS NEEDLE FREE CONNECTOR (8200)
2
Cleared 510(K)
K
95
3825
ANGIOFLUSH II FLUID MANAGEMENT SYSTEM
2
Cleared 510(K)
K
95
4969
POLYFIN QR SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
95
5732
VENTED SOLUTION SET
2
Cleared 510(K)
K
95
5709
WINGED & SUBCUTANEOUS INFUSION SETS
2
Cleared 510(K)
K
95
2852
NIMA (NEEDLELESS INJECTIONSITE MASTER ADAPTER) & I.V. SET
2
Cleared 510(K)
K
95
5783
VLV SA.EF INFUSION PORT EXTENSION SETS
2
Cleared 510(K)
K
95
4823
VENIPUNCTURE KIT
2
Cleared 510(K)
K
95
3746
ARROW HIGH FLOW FLUID ADMINSITRATION SET W/BLOOD FILTER & EXTENSION SET
2
Cleared 510(K)
K
95
4983
EXTENSION SET WITH CHECK VALVE
2
Cleared 510(K)
K
94
0832
I.V. ADMINISTRATION SET CONNECTING DEVICE
2
Cleared 510(K)
K
95
0970
INFUSION SET
2
Cleared 510(K)
K
95
4870
SIMS DELTEC ANTI-SIPHON VALVE
2
Cleared 510(K)
K
95
4841
MODEL D-285N ADMINISTRATION SET
2
Cleared 510(K)
K
95
4813
ICU EXTENSION KIT
2
Cleared 510(K)
K
95
4123
LOW PROFILE SAFSITE Y-SITE
2
Cleared 510(K)
K
95
3791
VLV SA EF INFUSION PORT
2
Cleared 510(K)
K
95
3343
NEEDLELESS INJECTION SITE
2
Cleared 510(K)
K
95
3584
LIFESHIELD LUER ACTIVATED VALVE MALE ADAPTER PLUG
2
Cleared 510(K)
K
95
1665
PP-SPF1 / PP-SPF2
2
Cleared 510(K)
K
95
3474
IV START KIT
2
Cleared 510(K)
K
95
3225
IVAC BALL VALCE ADMIN. SETS
2
Cleared 510(K)
K
93
3898
HUBER NEEDLE SETS
2
Cleared 510(K)
K
95
2160
INTRAVASCULAR (I-V) ADMININISTRATION SET (DVGENPERS FPA)
2
Cleared 510(K)
K
95
2976
PLASTIC BLUNT CANNULA
2
Cleared 510(K)
K
95
2242
TRANSFEER SPIKE II
2
Cleared 510(K)
K
95
2810
DOSI-FLOW, MODELS 20 & 30
2
Cleared 510(K)
K
95
3231
PPMI-(XXX) AND PPMO-(XXX)
2
Cleared 510(K)
K
95
0895
HARMAC EXTENSION INFUSION SET
2
Cleared 510(K)
K
95
0153
VENTED/NONVENTED GEMINI ADMINISTRATION SET WITH CHECK VALVE AND TWO SAFSITE(TM) VALVES
2
Cleared 510(K)
K
95
2760
FIXED FLOW RATE GRAVITY ADMINISTRATION SETS
2
Cleared 510(K)
K
95
2664
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
95
2392
MLI SET
2
Cleared 510(K)
K
95
2074
SOLUTION SET WITH 1.2 MICRON AIR ELIMINATING FILTER
2
Cleared 510(K)
K
95
0597
CORE-RESISTANT HUBER INFUSION SET WITH Y-SITE
2
Cleared 510(K)
K
95
1922
ADMINISTRATION SETS WITH BALL FLOAT
2
Cleared 510(K)
K
94
2988
FILTERED EXTENSION SETS
2
Cleared 510(K)
K
94
2271
LEVEL 1* INJECT NEEDLE-FREE INJECTION SITE
2
Cleared 510(K)
K
94
3591
VECTOR(TM) AMBULATORY DRUG DELIVERY SYSTEM
2
Cleared 510(K)
K
94
5298
SMARTFLOW I ADMINISTRATION SET
2
Cleared 510(K)
K
95
2053
E-Z SET, SAF-T E-Z SET, AND MINICATH INFUSION SETS
2
Cleared 510(K)
K
94
4692
C-SERIES HOMEPUMP
2
Cleared 510(K)
K
94
3770
LOW VOLUME MULTIPORT
2
Cleared 510(K)
K
94
3038
STATLOCK-IPIDURAL
2
Cleared 510(K)
K
94
4824
SUREWING
2
Cleared 510(K)
K
94
2931
STATLOCK SECUREMENT DEVICES
2
Cleared 510(K)
K
94
4293
SABRATEK SABSIL SETS
2
Cleared 510(K)
K
95
0304
DESERET (R) T-PORT (R) MULTI FLO(TM) AND DESERET (R)PRN ADAPTER
2
Cleared 510(K)
K
95
0303
DESERET(R) I.V. LOOP AND DESERET (R) J LOOP
2
Cleared 510(K)
K
95
0302
E-Z SET(R) AND MINICATH(R) INFUSION SETS
2
Cleared 510(K)
K
94
6082
BEECH PRO LOK FIXED
2
Cleared 510(K)
K
93
3848
PRESPO 7, SELF-SUFFICIENT DRIP DEVICE
2
Cleared 510(K)
K
94
2446
I.V. ROLLER GUARD CLAMP
2
Cleared 510(K)
K
94
4320
VENTED/NON-VENTED GEMINI ADMINISTRATION SET
2
Cleared 510(K)
K
94
5617
PHARMA-PLAST PURELINE(TM) BASIC(TM) AND PURELINE(TM) CONTACT(TM) SUBCUTANEOUS INFUSION SETS
2
Cleared 510(K)
K
94
3897
NU-SITE
2
Cleared 510(K)
K
94
2349
MICROBORE EXTENSION SET
2
Cleared 510(K)
K
94
0657
IV BAG PUMP
2
Cleared 510(K)
K
94
1190
CLAVE NEEDLE-LESS CONNECTOR OPEN EXTENSION SET
2
Cleared 510(K)
K
94
4619
I.V.I.D. FLUID ADMINISTRATION SET MARKER
2
Cleared 510(K)
K
93
5811
BOLUS DISPENSER
2
Cleared 510(K)
K
94
5070
VERSASAE PLASTIC CANNULA- 11 GAUGE
2
Cleared 510(K)
K
94
4208
IV ADMINISTRATION SET FPA
2
Cleared 510(K)
K
94
1244
SAFELINE SYSTEM TURN LOCK CANNULA
2
Cleared 510(K)
K
94
0319
R-GROUP INTERNATIONAL COILED LOW PRESSURE EXTENSION LINE
2
Cleared 510(K)
K
94
2046
PHARMACIA DELTEC EXTENSION SET WITH ANTI-SIPHON VALVE
2
Cleared 510(K)
K
94
0697
BECTON DICKINSON INTERLINK(TM) LEVER/Y LOCK
2
Cleared 510(K)
K
94
1453
CHECK VALVE SOLUTION SET
2
Cleared 510(K)
K
92
4010
REDINOV PERFUSION SET
2
Cleared 510(K)
K
93
4095
IVAC VENTED SYRINGE ADAPTER ADMINISTRATION SETS
2
Cleared 510(K)
K
93
4513
PROVIDER PUMP SET W/INFUSION CARTRIDGE
2
Cleared 510(K)
K
94
2181
SOF-SET QR INFUSION SETS, MODELS MMT-115 AND MMT-116
2
Cleared 510(K)
K
94
1445
EXTENSION SET WITH ANTI-SIPHON VALVE
2
Cleared 510(K)
K
94
0897
IVAC NEEDLELESS INFECTION VALVE ADMINISTRATION SET
2
Cleared 510(K)
K
93
4119
ENERGIZED DRUG CONTAINER SYSTEM
2
Cleared 510(K)
K
92
5733
ISOFLUX IXL FLOW REGULATOR
2
Cleared 510(K)
K
92
5732
ISOFLUX IXZ FLOW REGULATOR
2
Cleared 510(K)
K
92
5731
ISOFLUX IXP FLOW REGULATOR
2
Cleared 510(K)
K
94
0867
CONTROL-A-FLO(TM) REGULATOR
2
Cleared 510(K)
K
92
6448
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
94
0054
MEASURED VOLUME SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
93
1173
PRIMARY ADMIN SET W/UNIV SP-MAN BELOW/ABV PUMP CH
2
Cleared 510(K)
K
93
2165
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
94
0056
WINGED INFUSION SET A-PORT VASCULAR ACCESS SYSTEM
2
Cleared 510(K)
K
94
0053
INFUSION ADMINISTRATION SET
2
Cleared 510(K)
K
93
3326
LIFECARE PLUMSET VENTED SECONDARY I.V. SET
2
Cleared 510(K)
K
94
0072
I.V. SET (20 DROPS/ML)
2
Cleared 510(K)
K
94
0073
EXTENSION TUBE, EXTENSION TUBE LENGTH 20, & 30
2
Cleared 510(K)
K
94
0689
WALL IV EXTENSION TUBE
2
Cleared 510(K)
K
93
1377
SAFELINE SYSTEM IV ADMINISTRATION SETS & COMPONENT
2
Cleared 510(K)
K
94
0296
SAFE CONNECTOR
2
Cleared 510(K)
K
93
3390
REMOTE RESERVOIR ADAPTER(TM) CASSETTE WITH BAG
2
Cleared 510(K)
K
93
2856
IRRIGATION ACCESS CAP
2
Cleared 510(K)
K
93
5601
0.22 MICRON FINAL FILTER WITH EXTENSION TUBE
2
Cleared 510(K)
K
93
0854
SOLUTION SET WITH .2 MICRON FILTER
2
Cleared 510(K)
K
93
1550
EZ ADMINISTRATION SET
2
Cleared 510(K)
K
93
2637
SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
93
1659
3 LEAD CONNECTOR
2
Cleared 510(K)
K
93
3852
PRO-LOK EXTENSION SET
2
Cleared 510(K)
K
93
3749
BEECH VERSA LOK
2
Cleared 510(K)
K
93
3732
BEECH PROLOK
2
Cleared 510(K)
K
93
1658
IN-LINE BURETTE SET
2
Cleared 510(K)
K
93
2638
HUBER NEEDLE INFUSION SET
2
Cleared 510(K)
K
93
2446
INJECTION SITE
2
Cleared 510(K)
K
93
1119
DURHAM; NON CORING WINGED ADMINISTRATION SET
2
Cleared 510(K)
K
93
0974
DURHAM; INJECTION SITE EXTENSION SET, LUER LOCK
2
Cleared 510(K)
K
93
0927
DURHAM;T ADAPTOR EXTENSIONSET W/INJECTION SITE
2
Cleared 510(K)
K
92
5418
ENERGIZED CONTAINER SYSTEM
2
Cleared 510(K)
K
91
2069
AVI MODEL 4225 VENTED PIGGYBACK IV ADMIN SET
2
Cleared 510(K)
K
93
0926
DURHAM; Y CHECK SET-LUER LOCK W/INJECTION SITE
2
Cleared 510(K)
K
92
2115
IVAC NEEDLELESS INJECTION VALVE
2
Cleared 510(K)
K
92
5645
SELEC-3
2
Cleared 510(K)
K
93
0750
DURHAM; ADM. SET-LUER LOCK W/.22 MICRON FILTER
2
Cleared 510(K)
K
93
0751
DURHAM; EXTENSION TUBE LUER LOCK W/INJECTION SITE
2
Cleared 510(K)
K
93
0406
DURHAM; MIN BORE LUER LOCK EXTENSION SET
2
Cleared 510(K)
K
93
0410
DURHAM; LUER LOCK EXTENSION SET
2
Cleared 510(K)
K
92
5362
SUB-Q-SET(R) SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
92
5927
MPC-1000 INJECTION CAP/PLUG
2
Cleared 510(K)
K
92
5930
MPC-150 MALE TO MALE LUER ADAPTER
2
Cleared 510(K)
K
92
6119
EXEL HUBER INFUSION SET ROTATING WING
2
Cleared 510(K)
K
92
5430
LO-PROFILE EXTENSIONSET W/ .22 MICRON FILTER
2
Cleared 510(K)
K
92
5058
BARD AMBU PUMP SPIK TUB SET PACRET PROVID PUMP SET
2
Cleared 510(K)
K
93
0855
REPLACEMENT CAP
2
Cleared 510(K)
K
92
5228
IVAC 59 SERIES UNIVERSAL SET W/ ANTI-FREE FLOW VAL
2
Cleared 510(K)
K
92
6184
DOUGLAS MEDICAL PRODUCTS, INC. VENTED SPIKE ADAPT
2
Cleared 510(K)
K
92
5219
IVION ADMIN SETS W/FLOW CLIPS
2
Cleared 510(K)
K
93
1813
NEEDLESAFE HANDGUARD
2
Cleared 510(K)
K
92
4721
BAXTER SOLUTION ADMINISTRATION SETS
2
Cleared 510(K)
K
92
1322
MORSE ANESTHESIA MANIFOLD
2
Cleared 510(K)
K
92
5126
INTERLINK(TM) INJECTION SITE
2
Cleared 510(K)
K
92
4718
SHROUDED NEEDLE DEVICES
2
Cleared 510(K)
K
92
3560
ACCU-DROP I.V. EXTENSION SET
2
Cleared 510(K)
K
92
2637
HORIZON PUMP Y-TYPE BLOOD SET
2
Cleared 510(K)
K
92
4207
AVI(TM) MODEL 232 STANDARD IV ADMINISTRATION SET
2
Cleared 510(K)
K
92
1899
INTERLINK SYSTEM - T-CONNECTOR EXTENSION SET
2
Cleared 510(K)
K
92
2469
PRO-LOK EXTENSION SET(S)
2
Cleared 510(K)
K
92
3882
IV-TUBE SECURE
2
Cleared 510(K)
K
92
1594
HAEMOTROL MODEL #HT-SB/6 BURETTE SET
2
Cleared 510(K)
K
92
1429
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
90
4663
AUTO SASH (TM)
2
Cleared 510(K)
K
91
3982
LIFESHIELD ANESTHESIA SET
2
Cleared 510(K)
K
92
2558
INTERLINK(TM) INJECTION SITE
2
Cleared 510(K)
K
92
0537
SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
92
1674
LIFEPORT INFUSION SET AND INFUSION SET W/ Y SITE
2
Cleared 510(K)
K
92
1576
STRATO LIFEPORT LARGE BORE INFUSION SET
2
Cleared 510(K)
K
91
5571
CLAVE CONNECTOR
2
Cleared 510(K)
K
92
1391
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
92
1860
MODIFICATION TO IV SPIKE
2
Cleared 510(K)
K
91
5678
MERIT ADMINISTRATION SET
2
Cleared 510(K)
K
92
1703
CONTINU-FLO(R) SOLUTION SET
2
Cleared 510(K)
K
91
5828
INJECTION SITE WITH LUER LOCK
2
Cleared 510(K)
K
91
5109
RAPID ADD SITE DOUBLE LUMEN I.V.EXTENSION SET
2
Cleared 510(K)
K
92
0694
8000 SERIES VOLUMETRIC PUMP NON-GRAVITY FLOW SET
2
Cleared 510(K)
K
91
5390
3 LEAD EXTENSION WITH 2 INTERLINK INJECTION SITES
2
Cleared 510(K)
K
91
4924
CHEMO PRIMING PIN(TM)
2
Cleared 510(K)
K
91
3337
INJECTION CAP
2
Cleared 510(K)
K
91
4113
ANGIOGRAPHIC FLUSH SYSTEM
2
Cleared 510(K)
K
91
4792
PN 62290 0.22 MICRON MICRO INFUS I.V. EXTEN SET
2
Cleared 510(K)
K
90
5208
MORSE ANESTHESIA
2
Cleared 510(K)
K
91
4026
ANGIODYNAMICS ANGIOFILL FLUID MANAGEMENT SYSTEM
2
Cleared 510(K)
K
91
2856
MEDE-FLO I.V. EXTENSION SET
2
Cleared 510(K)
K
91
4048
NEEDLE*LOCK(TM) WITH INTERLINK(TM) INJECTION SITE
2
Cleared 510(K)
K
91
3333
I.V. PRIMING SET
2
Cleared 510(K)
K
91
4074
8000 SERIES VOLUMETRIC PUMP SOLUTION SET
2
Cleared 510(K)
K
91
3076
I.V. INSTANT TIMER
2
Cleared 510(K)
K
91
2861
FLU ADMIN/WASTE DISP SYS/PROTEC STA/ADMIN/FLUSH-N-
2
Cleared 510(K)
K
91
3627
3 PORT ADAPTER
2
Cleared 510(K)
K
91
3311
SAFETY INJECTION PORT, MODIFICATION
2
Cleared 510(K)
K
91
2141
VOLUMETRIC PUMP SOLUTION SET MODIFIED CASSETTE
2
Cleared 510(K)
K
91
1128
MEDIZIV INFUSION SET
2
Cleared 510(K)
K
91
0159
WINGED ADMININ. SET W/NON-CORING NEEDLE
2
Cleared 510(K)
K
91
2860
INTRAVASCULAR ADMINISTRATION SETS
2
Cleared 510(K)
K
91
1815
3RD HAND HELPER
2
Cleared 510(K)
K
91
1443
INSUL-LINE
2
Cleared 510(K)
K
91
1868
INTERLINK(TM) BLUNT CANNULA, MODIFICATION
2
Cleared 510(K)
K
91
1753
INTERVASCULAR ADMINSTRATION SET
2
Cleared 510(K)
K
91
1931
LUER LOCK INJECTION CAP
2
Cleared 510(K)
K
91
1136
B-D SAFETY-LOK(TM) I.V. NEEDLES
2
Cleared 510(K)
K
90
5218
4 LOW VOLUME IV EXTENSION SET WITH SLIDE CLAMP
2
Cleared 510(K)
K
90
5219
4' LOW VOLUME IV EXTENSION SET
2
Cleared 510(K)
K
90
5374
IV EXTENSION SETS WITH .22 MICRON FILTER
2
Cleared 510(K)
K
91
0142
SPARK KIT(R), MODIFICATION
2
Cleared 510(K)
K
91
0546
PIGGY LOCK NEEDLE HOUSING
2
Cleared 510(K)
K
91
0695
AUTO SASH (TM)
2
Cleared 510(K)
K
90
4886
VASCULAR ACCESS PORT CONTINUOUS INFUSION SETS
2
Cleared 510(K)
K
90
2858
AVI MODEL 4206 MANIFOLD CHECKVALVE IV ADMIN. SET
2
Cleared 510(K)
K
90
4685
EXEL HUBER INFUSION SET WITHOUT INJECTION SITE (Y)
2
Cleared 510(K)
K
90
2810
STERILE I.V. START KIT
2
Cleared 510(K)
K
90
2109
STATLOCK IV CONNECTOR AND ANCHOR SET
2
Cleared 510(K)
K
90
1088
LOW VOLUME BIFURCATED IV EXTENSION SET
2
Cleared 510(K)
K
90
1089
LOW VOLUME TRIFURCATED IV EXTENSION SET
2
Cleared 510(K)
K
90
0336
V SET
2
Cleared 510(K)
K
90
4217
PRO-LOK (TM) EXTENSION SETS
2
Cleared 510(K)
K
90
3809
PROTECTED NEEDLE WITH OR WITHOUT IV SET
2
Cleared 510(K)
K
90
4013
SPIVE NEEDLE SYSTEM, MODIFICATION
2
Cleared 510(K)
K
90
2330
E-Z FLO + SET
2
Cleared 510(K)
K
90
3541
SAFETY INJECTION PORT
2
Cleared 510(K)
K
90
1949
IV SET
2
Cleared 510(K)
K
89
6893
KAWASUMI I.V. ADMINISTRATION SET WITH BURETTE
2
Cleared 510(K)
K
89
6892
KAWASUMI Y-TYPE BLOOD ADMINISTRATION SET
2
Cleared 510(K)
K
89
6896
KAWASUMI SMALL VEIN INFUSION SET
2
Cleared 510(K)
K
89
6895
KAWASUMI I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
89
6894
KAWASUMI BLOOD ADMINISTRATION SET
2
Cleared 510(K)
K
90
2166
WINGED INFUSION SET
2
Cleared 510(K)
K
89
5770
EXEL HUBER INFUSION SET
2
Cleared 510(K)
K
90
1151
I.V. ADMINISTRATION SET CONNECTING DEVICE
2
Cleared 510(K)
K
90
2196
MODIFIED STICK-GARD SAFETY NEEDLE
2
Cleared 510(K)
K
90
0353
SHIELDED PIGGYBACK IV NEEDLE
2
Cleared 510(K)
K
90
1729
SAF-T CLIK I.V. IN-LINE CONNECTOR & EXTENSION SET
2
Cleared 510(K)
K
90
1081
PRO-LOCK(TM) SHIELDING NEEDLE CONNECTOR ASSEMBLY
2
Cleared 510(K)
K
90
1046
VERSA-LOCK(TM) UNIVERSAL NEEDLE CONNECTOR
2
Cleared 510(K)
K
90
0909
IN-LINE VIAL CONNECTION SITE
2
Cleared 510(K)
K
90
0651
TS-1800 MEDICATION TRANSFER SPIKE
2
Cleared 510(K)
K
90
0188
ADVANCE ADMINISTRATION SETS (VARYING LENGTH)
2
Cleared 510(K)
K
90
0187
ADVANCE CONTRAST MEDIA SETS (VARYING LENGTH)
2
Cleared 510(K)
K
90
0644
I.V. FREEDOM CLIP
2
Cleared 510(K)
K
90
0427
IV TRIFURCATED EXTENSION SET
2
Cleared 510(K)
K
90
0426
IV BIFURCATED EXTENSION SET
2
Cleared 510(K)
K
89
7065
PORT INFUSION SET (PIS) INFUSION SET (IS)
2
Cleared 510(K)
K
89
6561
EXTENSION SET
2
Cleared 510(K)
K
89
6346
GRIPPER PORT-A-CATH NEEDLE WITH STOPCOCK
2
Cleared 510(K)
K
89
6161
AVI MODEL 2012, 1.2 MICRON FILTER IV ADMINISTRA.
2
Cleared 510(K)
K
89
5290
CHEMO-SPIKE RECONSTITUTION DEVICE
2
Cleared 510(K)
K
89
5291
IV DISPESNSING SPIKE
2
Cleared 510(K)
K
89
3646
VOLUMETRIC PUMP SOLUTION SET W/INTEGRAL AIRWAY
2
Cleared 510(K)
K
89
6291
INJECTION PORT II --- FOR INTERMITTENT INJECTION
2
Cleared 510(K)
K
89
5480
BLUNT NEEDLE PORT/I.V. PORT
2
Cleared 510(K)
K
89
5046
REMOTE RESERVOIR ADAPTER CASSETTE W/BAG SPIKE
2
Cleared 510(K)
K
89
5481
SHAMROCK SAFETY WINGED INFUSION SET
2
Cleared 510(K)
K
89
5367
INTRAVENOUS EXTENSION SET
2
Cleared 510(K)
K
89
5109
SECONDARY IV SET WITH PROTECTED NEEDLE
2
Cleared 510(K)
K
89
1193
MEDI-TRACE ACCU-NATE DEVICE
2
Cleared 510(K)
K
89
3716
VOLUMETRIC PUMP SOLUTION SET FOR FLO-GARD 8000
2
Cleared 510(K)
K
89
4787
MEL-PAK GENERAL DRUG DELIVERY SYSTEM KIT
2
Cleared 510(K)
K
89
4842
IMED GEMINI 12 NONVENTED Y-TYPE BLOOD/SOLUTION ADM
2
Cleared 510(K)
K
89
3909
MODIFIED MATERIAL USED IN INFUSION T
2
Cleared 510(K)
K
89
3120
KIT, INTRAVENOUS EXTENSION TUBING
2
Cleared 510(K)
K
89
2429
INJECTION PORT FOR---INTERMITTENT INJECTION
2
Cleared 510(K)
K
89
2440
KENDALL CURITY EXTENSION TUBES
2
Cleared 510(K)
K
89
2438
KENDALL CURITY INTRAVASCULAR CUT DOWN TUBES
2
Cleared 510(K)
K
89
1164
SAMUELS - MICRO -SCLER CATHETER
2
Cleared 510(K)
K
89
1146
TERUMO SURFLO(R) INJECTION PLUG
2
Cleared 510(K)
K
89
1063
SURFLO(R) WINGED INFUSION SET
2
Cleared 510(K)
K
89
0489
EXTENSION SET W/FLOW REGULATOR
2
Cleared 510(K)
K
89
1226
VASCULAR ACCESS PORT CONTINUOUS INFUSION SET
2
Cleared 510(K)
K
89
1176
INJECTION SITE PLUG (INTRAVASCULAR ADMINISTRATION)
2
Cleared 510(K)
K
88
5031
LOW ADSORPTION ADMINISTRATION SET
2
Cleared 510(K)
K
89
0679
SCALP VEIN SET
2
Cleared 510(K)
K
89
0176
EXTENSION SETS WITH AND WITHOUT FILTERS
2
Cleared 510(K)
K
89
1072
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
88
4511
SAFE MULTIPORT INJECTOR
2
Cleared 510(K)
K
89
0340
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
88
4657
LILY I.V. SET
2
Cleared 510(K)
K
88
4141
MONOPLACE HYPERBARIC EXTENSION SET (L 11055)
2
Cleared 510(K)
K
88
3986
CRIS ADAPTER
2
Cleared 510(K)
K
88
5264
WINGED INFUSION SET
2
Cleared 510(K)
K
88
4102
MODIFIED 7 INCH CONTINUOUS INFUSION SETS
2
Cleared 510(K)
K
88
5030
STANDARD ADMINISTRATION SETS
2
Cleared 510(K)
K
88
3764
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
88
4264
HIGH RISK NEEDLE CONNECTOR ASSEMBLY
2
Cleared 510(K)
K
88
4053
PRN PLUS + INFUSION SET
2
Cleared 510(K)
K
88
3318
VALLEYLAB I.V. ADMINISTRATION SETS
2
Cleared 510(K)
K
88
3612
LECTROSPIRAL
2
Cleared 510(K)
K
88
3638
SAFESITE INJECTION SITE AND BLUNT CANNULA
2
Cleared 510(K)
K
88
2347
HARMAC EXTENSION INFUSION SET
2
Cleared 510(K)
K
88
2503
30 IV EXTENSION SET W/TWO MALE LUER LOCKS
2
Cleared 510(K)
K
88
1975
SET, INTRAVASCULAR
2
Cleared 510(K)
K
88
2798
MULTIFLO ADAPTER
2
Cleared 510(K)
K
88
2797
LUER-LOK MULTIFLO ADAPTER
2
Cleared 510(K)
K
88
2302
IVAC(R) UNVENTED VOL. INFUSION SET MODEL 52080
2
Cleared 510(K)
K
88
2007
EXTENDED LIFE INJECTION SITE
2
Cleared 510(K)
K
88
1321
BLOOD/SOLUTION SET W/PRESSURE PUMP
2
Cleared 510(K)
K
88
1234
VENOVALVE(TM)
2
Cleared 510(K)
K
88
1052
CHECK VALVE
2
Cleared 510(K)
K
88
1390
NEEDLE SHIELD NEEDLE DISPOSAL UNIT
2
Cleared 510(K)
K
88
0928
MARQUETTE MEDICAL, INC. IV EXTENSION SETS
2
Cleared 510(K)
K
87
4725
SITE SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
88
0482
SECONDARY SOLUTION ADMINISTRATION SET W/SHEATH
2
Cleared 510(K)
K
87
4307
MODEL DMC-75 MINI-CATHETER SET
2
Cleared 510(K)
K
87
4581
IVAC(R) DUAL RATE ADAPTER - MODEL 70090
2
Cleared 510(K)
K
87
4133
MX710 SERIES VASCULAR ACCESS INFUSION SET
2
Cleared 510(K)
K
87
4467
SET, ADMINISTRATION INTRAVASCULAR
2
Cleared 510(K)
K
87
2953
DISPOSABLE I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
87
4403
A SERIES OF 7 INCH CONTINUOUS INFUSION SETS
2
Cleared 510(K)
K
87
3729
RATE-MATE NITROGLYCERIN I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
87
3894
CONTINU-FLO SOLUTION W/CHECK VALVE 2 Y-INJECT SITE
2
Cleared 510(K)
K
87
3885
PHARMACIA DELTEC SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
87
3876
PHARMACIA DELTEC BAG SPIKE SET
2
Cleared 510(K)
K
87
3042
MODEL 1330 EXTENSION SET
2
Cleared 510(K)
K
87
1995
MICROS(TM)
2
Cleared 510(K)
K
87
2945
LOOK FLUID DISTRIBUTION SET
2
Cleared 510(K)
K
87
2124
CHURCHILL ALBUMIN IV ADMINISTRATION SET
2
Cleared 510(K)
K
87
2123
CHURCHILL TPN ADMINISTRATION SET
2
Cleared 510(K)
K
87
2795
CHANGE IN STERILITY TEST METHOD & TEST LAB. SITE
2
Cleared 510(K)
K
87
0995
SCALP VEIN SET
2
Cleared 510(K)
K
87
1843
TWO FLUID W/CHECK VALVE
2
Cleared 510(K)
K
87
0866
THE GRIPPER(TM) PORT-A-CATH NEEDLES
2
Cleared 510(K)
K
87
1841
THREE FLUID I.V. SETS
2
Cleared 510(K)
K
87
1842
TWO FLUID I.V. SETS
2
Cleared 510(K)
K
87
1732
CHURCHILL-H VENTED IV SET W/METERING CHAMBERS
2
Cleared 510(K)
K
87
1086
IV PUMP SET
2
Cleared 510(K)
K
87
1753
MASTER MEDICAL DEVICE IS I.V. STAT 2
2
Cleared 510(K)
K
87
0581
LIFEPORT(R) 7 INCH CONTINUOUS INFUSION SET
2
Cleared 510(K)
K
87
0582
LIFEPORT(R) 7 INCH CONTINUOUS INFUSION W/Y-SITE
2
Cleared 510(K)
K
87
0940
SOLUTION ADMINI. SETS- ALTER. DRIP CHAMBER/CONNEC.
2
Cleared 510(K)
K
87
0913
INJECTION SITE #014456-120
2
Cleared 510(K)
K
86
4296
S.C.T. MULTI PORT, INJECTION SITE
2
Cleared 510(K)
K
87
0188
NORFOLK MEDICAL BUTTERFLY INFUSION SET
2
Cleared 510(K)
K
86
4453
EMERGENCY & MILITARY INFUSION SYSTEM
2
Cleared 510(K)
K
86
4405
MANAN CONTRAST MEDIA ADMINISTRATION SET
2
Cleared 510(K)
K
86
4164
CRIS ADAPTED WITH VOLUME LIMITING BAG
2
Cleared 510(K)
K
86
3304
PRESELECTED FLOW RATE I.V. SET
2
Cleared 510(K)
K
86
4338
SECONDARY SET LOCK
2
Cleared 510(K)
K
86
3814
BAG SPIKE EXTENSION SET
2
Cleared 510(K)
K
86
2289
KOREAN GREEN CROSS SCALP VEIN SET
2
Cleared 510(K)
K
86
2491
EXEL BUTTERFLY SCALP VEIN SET
2
Cleared 510(K)
K
86
0952
I.V. SET WITH AND WITHOUT AIR VENT
2
Cleared 510(K)
K
86
2653
LUER LOCK ADAPTER/NUT
2
Cleared 510(K)
K
86
1182
TIMELINE VENIPUNCTURE SYSTEM
2
Cleared 510(K)
K
86
0609
TIMELINE VENIPUNCTURE SYSTEM
2
Cleared 510(K)
K
86
1275
HIGH FLOW I.V. SET
2
Cleared 510(K)
K
86
0616
VOLUME CONTROL SET WITH EXTENSION
2
Cleared 510(K)
K
86
1521
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0330)
2
Cleared 510(K)
K
86
1518
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0205F)
2
Cleared 510(K)
K
86
1519
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0330F)
2
Cleared 510(K)
K
86
1520
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0205)
2
Cleared 510(K)
K
86
1250
MESULIN, INSULIN INFUSION SET
2
Cleared 510(K)
K
86
1430
CHURCHILL INJECTION SITE
2
Cleared 510(K)
K
86
1439
CHURCHILL FEMALE LUER LOCK CAP
2
Cleared 510(K)
K
86
0157
NITROGLYCERIN INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
86
0322
CLINISET INFUSION SET
2
Cleared 510(K)
K
85
2616
MIRAGE INTRAVENOUS INFUSION SET OLOVSON-STERILE
2
Cleared 510(K)
K
86
0541
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
86
0605
FILTER SET 1) 1.2 MIC FILTER 2) 3.0 MIC FILTER
2
Cleared 510(K)
K
85
4365
IV SETS WITH NO PHTHALATE PLASTICIZER COMPONENTS
2
Cleared 510(K)
K
86
0272
SOLUTION ADMINISTRATION SETS
2
Cleared 510(K)
K
85
4806
RAPID SOLUTION ADMIN SET W/INTEGRAL HEAT EXCHANGER
2
Cleared 510(K)
K
85
4965
IN LINE VALVE CATALOG NO. 2000A
2
Cleared 510(K)
K
86
0242
JMS INFUSION SET
2
Cleared 510(K)
K
85
4804
MULTIPLE I.V. SETS
2
Cleared 510(K)
K
86
0201
PARENTERAL ADMINISTRATION SET
2
Cleared 510(K)
K
85
4754
PATIENTMATE TM
2
Cleared 510(K)
K
85
4658
CHURCHILL - HBC VENTED BALL CHECK IV SET
2
Cleared 510(K)
K
85
4574
IVAC CONTROLLED RELEASE INFUSION SYSTEM
2
Cleared 510(K)
K
85
4628
CHURCHILL-HCM VENTED IV SET
2
Cleared 510(K)
K
85
4446
TERUMO TERUFUSION BLOOD & Y-TYPE ADMIN. SET
2
Cleared 510(K)
K
85
4636
CHURCHILL-HE VENTED IV SET
2
Cleared 510(K)
K
85
4630
CHURCHILL-HS SUSPENDED NON-VENTED IV SET
2
Cleared 510(K)
K
85
4627
CHURCHILL-HS SUSPENDED VENTED IV SET
2
Cleared 510(K)
K
85
4436
CHURCHILL-H SCALP VEIN SET
2
Cleared 510(K)
K
85
4437
CHURCHILL-H VENTED IV SET
2
Cleared 510(K)
K
85
4435
CHURCHILL-H NON-VENTED IV SET
2
Cleared 510(K)
K
85
4346
MEDIFLEX DISPOSABLE TUBING CLAMP
2
Cleared 510(K)
K
85
2254
I.V. STAT MASTER
2
Cleared 510(K)
K
85
3019
NITROGLYCERIN INFUSION SET
2
Cleared 510(K)
K
85
3287
HUBOUT
2
Cleared 510(K)
K
85
3527
JUFREY CORP. UNIV. DISPOS. SCALP VEIN INFUSION SET
2
Cleared 510(K)
K
85
2606
FLEBOSET 1401(60 DROPS/MI) AND FLEBOSET1400(20)
2
Cleared 510(K)
K
85
3204
CHURCHILL VENTED IV SET
2
Cleared 510(K)
K
85
3385
I.A.S.S., IV SET W/AIR VENT & I.A.P.S. W/O AIRVENT
2
Cleared 510(K)
K
85
3255
OMNIMED I.V. SOLUTION ADMIN. SET
2
Cleared 510(K)
K
85
1516
CHERMEL SCALP VEIN SET
2
Cleared 510(K)
K
85
3387
ET - EXTENSION SETS
2
Cleared 510(K)
K
85
3327
JUFREY CORP. UNIVERSAL DISPOS. SCALP VEIN INFUSION
2
Cleared 510(K)
K
85
3086
SECONDARY ADMINISTRATION SET
2
Cleared 510(K)
K
85
2881
VENTED SECONDARY IV ADMINISTRATION SET
2
Cleared 510(K)
K
85
3184
PIGGYMATE I.V. TUBING LOCK
2
Cleared 510(K)
K
85
2989
WINGED INFUSION SETS
2
Cleared 510(K)
K
85
2361
INTRAVENOUS INJECTION SET
2
Cleared 510(K)
K
85
2488
CONTROLLED RELEASE INFUSION SYSTEM(CRIS)
2
Cleared 510(K)
K
85
2259
IVENT INTRAVENOUS ADMINSTRATION SET
2
Cleared 510(K)
K
85
2106
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
85
2140
NAMIC CONTRAST & FLUID DELIVERY SPIKES(VARIOUS)
2
Cleared 510(K)
K
85
1336
IV/0165 INFUSION SET
2
Cleared 510(K)
K
85
0769
VIGGO ACCESSORIES FOR I.V. THERAPY
2
Cleared 510(K)
K
85
1299
CORRECT FLO
2
Cleared 510(K)
K
85
0277
VIGGO I.V. ACCESSORIES-VIGGO EXTENSION TUBES ETC.
2
Cleared 510(K)
K
84
4843
IVAC DRUG ADMINISTRATION DEVICE
2
Cleared 510(K)
K
85
0506
CORRECT FLO INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
85
0061
MICRO VOLUME DOUBLE LINE EXTENSION SET
2
Cleared 510(K)
K
85
0533
ATLANTIC OPTICAL SYSTEMS OPTIFILTER SYSTEM
2
Cleared 510(K)
K
85
0339
SPECIAL PROCEDURES PACK
2
Cleared 510(K)
K
85
0507
CRITIKON I.V. ADMINISTRAION SET
2
Cleared 510(K)
K
85
0112
OMNIMED IV SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
84
4917
TURN NEEDLE INTRAVENOUS CANNUL, NUB, W/TUBING INTE
2
Cleared 510(K)
K
85
0088
ARTERIAL EXTENSION SET
2
Cleared 510(K)
K
84
4820
FLOW MED SK 140 BURET
2
Cleared 510(K)
K
84
4937
IVAC 52-99-0 UNVENTED & 52-99-1 VENTED VOL. INFUSI
2
Cleared 510(K)
K
84
3748
ANTI-ASPIRATION VALVE
2
Cleared 510(K)
K
84
4255
GENT-L-KARE STERILE I.V. START KIT
2
Cleared 510(K)
K
84
3090
UNIVERSITY OF CHICAGO VASCULAR ANGIOGRAM
2
Cleared 510(K)
K
84
3692
FLU VEN I.V. SET 0153-C PERMA-SET
2
Cleared 510(K)
K
84
3631
MINISET VEIN INFUSION SETS
2
Cleared 510(K)
K
84
2984
EXTENSION SET W/INJECTION SITE
2
Cleared 510(K)
K
84
2351
STERILE DESIGN-CUSTOM STERILE IV KIT
2
Cleared 510(K)
K
84
3463
PROVIDER BAG SPIKE W/12 MICROBORE EXTEN
2
Cleared 510(K)
K
84
2678
I.V. TRANSFER SPIKE
2
Cleared 510(K)
K
84
3185
IVAC C80014 Y SOLUTION ADMIN. SET
2
Cleared 510(K)
K
84
3054
DEKA SOLUTION ADMIN. SET DK 302-A
2
Cleared 510(K)
K
84
2858
FLUID ADMINISTRATION LINE W/SPIKE 14-923
2
Cleared 510(K)
K
84
3249
T-TYPE IV EXTENSION SET
2
Cleared 510(K)
K
84
2657
ACCESS. TO INTERAVACULAR ADMIN. SET
2
Cleared 510(K)
K
84
2088
FLU MET 2
2
Cleared 510(K)
K
84
2985
T- EXTENSION SET T-04-C
2
Cleared 510(K)
K
84
1717
INTRAVENOUS INJECTION SET
2
Cleared 510(K)
K
84
1562
HESUNG BLOOD TRANSFUSION SETS
2
Cleared 510(K)
K
84
2143
BENT WINGED MINI-VOL INFUSION SET
2
Cleared 510(K)
K
84
1564
HESUNG SCALP VEIN SET
2
Cleared 510(K)
K
84
1563
HESUNG'S SOLUTION INFUSION SETS
2
Cleared 510(K)
K
84
1772
HEPARIN CAP, INJECTION CAP MALE LUER-
2
Cleared 510(K)
K
84
1859
SECURA SET
2
Cleared 510(K)
K
84
1882
THREE WAY INFUSION SET
2
Cleared 510(K)
K
84
1361
SYRINGE ADDITIVE IV ADMIN. SETS
2
Cleared 510(K)
K
84
1186
INFUSION SET SCALP VEIN
2
Cleared 510(K)
K
84
1185
PLASTIC, STERILE TUBING CLOSED SET
2
Cleared 510(K)
K
84
1106
DELTA MULTIPLE NON RETURN CONNECTOR
2
Cleared 510(K)
K
84
0443
RETROGRADE INFUSION SET 3ML & 6ML-
2
Cleared 510(K)
K
84
1027
PROVIDER SITE PREP & CHECK STRIP KIT
2
Cleared 510(K)
K
84
1028
PROVIDER CAP SET
2
Cleared 510(K)
K
84
0760
HARVARD ANTI-REFLUX Y-SET
2
Cleared 510(K)
K
84
1025
TOP DISPOSABLE INFUSION SET
2
Cleared 510(K)
K
84
0878
QUIK LOK
2
Cleared 510(K)
K
84
0619
I.V. START KIT
2
Cleared 510(K)
K
84
0409
INFUSION SET-STERILE
2
Cleared 510(K)
K
84
0410
SOLUTION ADMIN. SET STERILE
2
Cleared 510(K)
K
84
0273
LOPEZ LOCK
2
Cleared 510(K)
K
84
0212
CONCENTRATED PLATELET ADMIN. SET
2
Cleared 510(K)
K
83
3398
MESULIN INSULIN INFUSION SET
2
Cleared 510(K)
K
83
4253
PBC IV SET NON-VENTED
2
Cleared 510(K)
K
83
4254
PBC IV SET VENTED
2
Cleared 510(K)
K
83
4252
PBC EXTENSION SET
2
Cleared 510(K)
K
84
0081
IV ADMINISTRATION SET
2
Cleared 510(K)
K
83
3939
NITROGLYCERIN I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
83
4289
CONTINU-FLO SOLUTION ADMIN. 2C9102
2
Cleared 510(K)
K
83
4130
INTRAVENOUS FILTER SET
2
Cleared 510(K)
K
83
4071
LYMPHANGIOGRAPHY SET SPECIAL 30G
2
Cleared 510(K)
K
83
3949
MICRO INFUSION SET
2
Cleared 510(K)
K
83
2284
SOLUTION ADMIN. SET 2C9096 W/10 PVC
2
Cleared 510(K)
K
83
3740
VENOSET MULTI-MED PIGGYBACK W/IVEX-2
2
Cleared 510(K)
K
83
3741
VENOSET MULTI MED DUAL RATE PIGGYBACK
2
Cleared 510(K)
K
83
3178
SOLUTION ADMINISTRATION LINE W/SPIKE
2
Cleared 510(K)
K
83
3033
INFUSION SET-52-05-1 20 DROPS-MI VOL
2
Cleared 510(K)
K
83
3034
UNIVERSAL VENTED & NON/VOLUME INFUS-
2
Cleared 510(K)
K
83
3030
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
83
2542
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
83
2549
SOLUTION ADMIN. LINE W/SPIKE
2
Cleared 510(K)
K
83
2622
WINGED INFUSION SET
2
Cleared 510(K)
K
83
2434
HBO-1 PASS-THROUGH/EXTENSION TUBE
2
Cleared 510(K)
K
83
2105
ADMINISTRATIVE IV SET
2
Cleared 510(K)
K
83
2104
STERILE DISP. BUTTERFLY INFUSION SET
2
Cleared 510(K)
K
83
1445
INFUSION SETS #'S 124 & 142 PERSONAL
2
Cleared 510(K)
K
83
2329
STERILE IV SET 4 SIZES
2
Cleared 510(K)
K
83
2123
VENIPUNCTURE VALVE
2
Cleared 510(K)
K
83
1311
SOLUTION ADMIN. SETS W/FLASHBALL
2
Cleared 510(K)
K
83
0182
CUSTOM IV SET
2
Cleared 510(K)
K
83
0453
IV ADMINISTRATION SETS - MVP INFUSION
2
Cleared 510(K)
K
83
1087
MINI-VOL EXTENSION SET
2
Cleared 510(K)
K
83
1088
MINI-VOL I.V. SET
2
Cleared 510(K)
K
83
0755
I.V. SETS WALRUS BRAND VARIOUS CONFIGUR-
2
Cleared 510(K)
K
83
0891
SPECIALTY SET MODEL IV7A01
2
Cleared 510(K)
K
83
0868
COMBISET OR INFUSION SET
2
Cleared 510(K)
K
83
0194
IDAS INFUSION SET
2
Cleared 510(K)
K
83
0654
INFUSION PUMP RETROGRADE EXTEN. AS 715
2
Cleared 510(K)
K
83
0565
SECURA SET SECONDARY ADMIN. SET
2
Cleared 510(K)
K
83
0377
SECURA SET PRIMARY ADMIN. SET
2
Cleared 510(K)
K
82
3845
PORT-LOCK
2
Cleared 510(K)
K
83
0448
SECURA SET VOLUME LIMITING SET
2
Cleared 510(K)
K
83
0258
CENTAURSET 300 & 300 P.E.D
2
Cleared 510(K)
K
83
0152
MINILOOP I.V. CONNECTORS & ADAPTOR
2
Cleared 510(K)
K
83
0178
MINILOOP DISPOS. IV CONNECTORS ADAPT.
2
Cleared 510(K)
K
82
3214
DOSIMETRIC RELEASE PROGRAM - ADMIN. SET
2
Cleared 510(K)
K
82
3346
ACCUSET ADMINISTRATION SET
2
Cleared 510(K)
K
82
3347
MACRODOT ADD-I-MED ADMIN. SET
2
Cleared 510(K)
K
82
3027
ACCUDOT 380 SECONDARY I.V. SET
2
Cleared 510(K)
K
82
2775
INFUS. SETS-9120-50 CM & 9121-100 CM,EXT
2
Cleared 510(K)
K
82
2848
PRIMARY & SECONDARY I.V. TUBING SETS
2
Cleared 510(K)
K
82
2836
MICROFLEX-VENOFLUX
2
Cleared 510(K)
K
82
2408
BOSTON INFUSION SETS
2
Cleared 510(K)
K
82
2407
BOSTON SCALP VEIN INFUSION SETS
2
Cleared 510(K)
K
82
2406
BOSTON SOLUTION INFUSION SETS
2
Cleared 510(K)
K
82
2354
DISPOSABLE PLASTIC TRANSFUS./INFUS. ASSB
2
Cleared 510(K)
K
82
2027
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
82
1995
SOLUTION ADMINISTRATION SET (W/O NEEDLE)
2
Cleared 510(K)
K
82
1750
DESERET E-Z SET INFUSION SET
2
Cleared 510(K)
K
82
1377
AS 700 SERIES INFUSION PUMP ADMIN.
2
Cleared 510(K)
K
82
1764
DISPOSABLE INTRAVENOUS INJECTION SYSTEM
2
Cleared 510(K)
K
82
1624
LOW VOLUME INFUSTION SET
2
Cleared 510(K)
K
82
1578
VENOSET DUAL-RATE PIGGYBACK W/IVEX &
2
Cleared 510(K)
K
82
1515
VENTED NITROGLYCERIN I.V. SET
2
Cleared 510(K)
K
82
1032
MODEL SR-1020LF
2
Cleared 510(K)
K
82
0747
MONOJECT SAF-T-LOCK
2
Cleared 510(K)
K
82
0788
CLIRANS PRIMING SET
2
Cleared 510(K)
K
82
0133
MCGAW FAT EMULSION SET
2
Cleared 510(K)
K
82
0453
THE INT-STOPPER
2
Cleared 510(K)
K
82
0278
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
82
0203
FLUID ADMINISTRATIVE SET, AFI
2
Cleared 510(K)
K
81
3259
IN-STOPPER (INJECTION CAP
2
Cleared 510(K)
K
81
3092
ACCUPRO I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
81
3194
AUTO-SYRINGE SUB-CUTEANEOUS SET
2
Cleared 510(K)
K
81
3083
VENOFIX SCALP VEIN SET
2
Cleared 510(K)
K
81
2657
INJECTION CAP, LUER LOCK
2
Cleared 510(K)
K
81
2688
QI 1150-1T INFUSION T
2
Cleared 510(K)
K
81
1885
30-30-2 700 SYRINGE EXTENSION SET
2
Cleared 510(K)
K
81
2231
INTRAVENOUS ADMINISTRATION SET
2
Cleared 510(K)
K
81
1914
FLU VEN I.V. SETS
2
Cleared 510(K)
K
81
1837
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
81
1078
RADIATION STERILIZED ADMIN. SET
2
Cleared 510(K)
K
81
1685
I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
81
1561
LO-VOL I.V. SETS
2
Cleared 510(K)
K
81
1463
AUTO-SYRINGE MICRO VOLUME EXTENSION SET
2
Cleared 510(K)
K
81
1107
IV SETS
2
Cleared 510(K)
K
81
1110
MODELS: 52-01-0, 52-01-1
2
Cleared 510(K)
K
81
1006
SOLUTION ADMINISTRATION SET
2
Cleared 510(K)
K
81
0239
VENTED PRIMARY PIGGYBACK VENOSET DUAL
2
Cleared 510(K)
K
81
0317
NITROGLYCERINE IV SET
2
Cleared 510(K)
K
81
0921
MALE LUER LOCK PLUGS
2
Cleared 510(K)
K
81
0721
PROCESS CHANGE
2
Cleared 510(K)
K
80
2170
SURU BLOOD COLLECTION SET
2
Cleared 510(K)
K
80
2169
SURU INFUSION SET TYPE J
2
Cleared 510(K)
K
81
0365
HAEMONETICS 170 Y INFUSION SET
2
Cleared 510(K)
K
80
2329
DISPOSABLE CONSTRAST DELIVERY SPIKE KIT
2
Cleared 510(K)
K
80
1871
PRIMARY SOLUTION ADMIN. SET-#86-01-0 260
2
Cleared 510(K)
K
80
1874
MODEL 86-21-1 260 APPROX. 60 DROPS/VENTD
2
Cleared 510(K)
K
80
1873
MODEL 86-21-0 260 SECONDARY MEDICATION
2
Cleared 510(K)
K
80
1872
MODEL 86-01-1 260 SOLUTION ADMIN. SET
2
Cleared 510(K)
K
80
1821
FLOW MED 150
2
Cleared 510(K)
K
80
1613
MODEL 72-81-0 UNVENTED SOLUTION ADM. SET
2
Cleared 510(K)
K
80
1540
MCGRAW I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
80
0878
SECONDARY I.V. TUBING SETS
2
Cleared 510(K)
K
80
1179
FLOW MED 160
2
Cleared 510(K)
K
80
0711
VOLUMETRIC PUMP CASSETTE W/ATTACHED SET
2
Cleared 510(K)
K
80
0637
PLASMA PRODUCTS CO., INTRA/ADMIN/SET-
2
Cleared 510(K)
K
80
0638
PLASMA PRODUCTS CO. NON-VENTED INTRA/SET
2
Cleared 510(K)
K
80
1004
FLOW MED 160
2
Cleared 510(K)
K
80
0600
B-D STASET, I.V. FLOW CONTROLLER
2
Cleared 510(K)
K
80
0403
MCGAW/EPIC I.V. ADMIN. SET
2
Cleared 510(K)
K
80
0358
Y-TYPE INFUSION SET (2 LEAD)
2
Cleared 510(K)
K
79
1496
LOW PLASTICIZER ADMINISTRATION SETS
2
Cleared 510(K)
K
80
0137
PRI. PIGGYBACK I.V. W/DUAL PIERCING PIN
2
Cleared 510(K)
K
79
2228
VENTED I.V. SET
2
Cleared 510(K)
K
79
2560
MASTER I.V. DIAL LOCK
2
Cleared 510(K)
K
79
2538
CONTINU-FLO ADMIN. SET CODE 2C/200
2
Cleared 510(K)
K
79
1930
IV EXTENSION SET SL
2
Cleared 510(K)
K
79
1672
ALBUMIN INTRAVENOUS ADMINISTRATION SET
2
Cleared 510(K)
K
79
1529
INFUSION NEEDLE SET
2
Cleared 510(K)
K
79
1173
SURFLO INJECTION PLUG
2
Cleared 510(K)
K
79
0901
I.V. TUBING ORGANIZER
2
Cleared 510(K)
K
79
0582
INTRAVASCULAR ADMINISTRATION SET
2
Cleared 510(K)
K
79
0604
CUSTOM TUBING SETS
2
Cleared 510(K)
K
79
0574
EPIC D215
2
Cleared 510(K)
K
79
0424
FLU-VEN 01510
2
Cleared 510(K)
K
79
0408
T-CONNECTOR
2
Cleared 510(K)
K
79
0077
BIOSTIL # 3884
2
Cleared 510(K)
K
79
0062
IV ADMINISTRATION SET WITH BACKCHECK
2
Cleared 510(K)
K
79
0108
FILTERSET 0.22, I.V. PUMP
2
Cleared 510(K)
K
78
2134
FILTER FOR HYPERALIMENTATION SET
2
Cleared 510(K)
K
78
1813
SOLUTION ADMINISTRATION, TIP PROTECTOR
2
Cleared 510(K)
K
78
1637
MODEL IV 1500 STANDARD BURETTE
2
Cleared 510(K)
K
78
1812
SOLUTION ADMINISTRATION, FLEX VALVE
2
Cleared 510(K)
K
78
1744
IV SET WITH GRADUATED CHAMBER
2
Cleared 510(K)
K
78
1785
I.V. SET WITH IN-LINE FILTER
2
Cleared 510(K)
K
78
1575
DISPOSABLE LYMPHANGIOGRAM SET
2
Cleared 510(K)
K
78
1184
INFUSION SET, VENOTHIN 19
2
Cleared 510(K)
K
78
1190
INFUSION SET, VENOTHIN 21
2
Cleared 510(K)
K
78
1188
INFUSION SET, VENOTHIN 25
2
Cleared 510(K)
K
78
1187
INFUSION SET W/ INJECTION SITE, 23D-W
2
Cleared 510(K)
K
78
1186
INFUSION, VENOTHIN 23
2
Cleared 510(K)
K
78
1185
INFUSION SET W/ INJECTION SITE
2
Cleared 510(K)
K
78
1189
FLU VEN 0151
2
Cleared 510(K)
K
78
1036
AUTO-SYRINGE INFUSION SET
2
Cleared 510(K)
K
78
0970
BURETTE SET WITH AIR CONTROL LEVER
2
Cleared 510(K)
K
78
0655
STERILE INFUSION SET TYPE S
2
Cleared 510(K)
K
78
0658
STERILE BLOOD ADMINISTRATION SET
2
Cleared 510(K)
K
78
0657
STERILE BLOOD COLLECTION SET
2
Cleared 510(K)
K
78
0656
STERILE INFUSION SET TYPE J
2
Cleared 510(K)
K
78
0559
DISPOSABLE INFUSION SET
2
Cleared 510(K)
K
78
0551
I.V. ADMINISTRATION SET WITH MINI-SPIKE
2
Cleared 510(K)
K
78
0481
I.V. LEVER CLAMP
2
Cleared 510(K)
K
78
0130
BURETTE INTRAVENOUS ADMIN. SETS.
2
Cleared 510(K)
K
77
1983
SCALP VEIN SET
2
Cleared 510(K)
K
77
2008
SCALP VEIN SETS
2
Cleared 510(K)
K
77
2036
IN-LINE BURETTE SET
2
Cleared 510(K)
K
77
1593
I.V. PUMP SET FOR FAT EMULSION
2
Cleared 510(K)
K
77
1270
BLOOD ADMINISTRATION TYPE R
2
Cleared 510(K)
K
77
1267
INFUSION SET TYPE S
2
Cleared 510(K)
K
77
1268
INFUSION SET TYPE J
2
Cleared 510(K)
K
77
1271
SCALP VEIN SET
2
Cleared 510(K)
K
77
1453
FLUID HANDLING DEVICE W/INPUT TUBING
2
Cleared 510(K)
K
77
1362
FLU VEN 0150
2
Cleared 510(K)
K
77
1339
MALE LUER LOCK PLUG
2
Cleared 510(K)
K
77
1204
SURFLO WINGED INFUSION SET
2
Cleared 510(K)
K
77
0743
SOLUSET FOR IV FAT EMULSION
2
Cleared 510(K)
K
77
0863
FLU VEN 0160
2
Cleared 510(K)
K
77
0763
BURETTE SET, 2C0132
2
Cleared 510(K)
K
77
0744
IV SET THAT REVERTS TO KVO RATE
2
Cleared 510(K)
K
77
0589
FILTER, INTRAVENOUS W/AUTO AIR VENT
2
Cleared 510(K)
K
77
0518
PIGGYBACK VENOSET W/0.22 FILTER
2
Cleared 510(K)
K
77
0171
ERIKA I.V. ADMINISTRATION SET
2
Cleared 510(K)
K
77
0051
VENOSET FOR I.V. FAT EMULSION
2
Cleared 510(K)
K
76
1327
IV SETS 2000 SERIES (HS-200,2L0,220)
2
Cleared 510(K)
K
76
0110
FILTER, I.V. (#4700)
2
Cleared 510(K)
K
76
0111
FILTER, I.V., WITH FLASH BULB (#4701)
2
Cleared 510(K)
K
76
0103
CAP, INJECTION (#4600)
2
Cleared 510(K)
FPB
Filter, Infusion Line
2
Product Code
FPK
Tubing, Fluid Delivery
2
Product Code
FPL
Incubator, Neonatal Transport
2
Product Code
FQH
Lavage, Jet
2
Product Code
FQJ
Support, Scrotal, Therapeutic
1
Product Code
FQK
Binder, Perineal
1
Product Code
FQL
Stocking, Medical Support (For General Medical Purposes)
1
Product Code
FQM
Bandage, Elastic
1
Product Code
FRF
Cleaner, Air, Medical Recirculating
2
Product Code
FRL
Fiber, Medical, Absorbent
1
Product Code
FRN
Pump, Infusion
2
Product Code
FRP
Holder, Infant Position
1
Product Code
FRR
Chamber, Reverse Isolation, Patient Care
2
Product Code
FSA
Lift, Patient, Non-Ac-Powered
1
Product Code
FSD
Binder, Abdominal
1
Product Code
HEF
Binder, Breast
1
Product Code
HFS
Shield, Nipple
1
Product Code
IKY
Mattress, Flotation Therapy, Non-Powered
1
Product Code
KMK
Device, Intravascular Catheter Securement
1
Product Code
KMO
Binder, Elastic
1
Product Code
KPE
Container, I.V.
2
Product Code
KYP
Snake Bite Suction Kit
1
Product Code
KYQ
Kit, Chemical Snake-Bite
3
Product Code
KZD
Infusor, Pressure, For I.V. Bags
1
Product Code
KZE
Injector, Fluid, Non-Electrically Powered
2
Product Code
LBI
Unit, Neonatal Phototherapy
2
Product Code
LDR
Controller, Infusion, Intravascular, Electronic
2
Product Code
LGM
Chamber, Patient Isolation
2
Product Code
LGN
Chamber, Patient Transport Isolation
2
Product Code
LGZ
Warmer, Thermal, Infusion Fluid
2
Product Code
LHF
Warmer, Microwave, Infusion Fluid
2
Product Code
LHI
Set, I.V. Fluid Transfer
2
Product Code
LJL
Detectors And Removers, Lice, (Including Combs)
1
Product Code
LJS
Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
2
Product Code
LJT
Port & Catheter, Implanted, Subcutaneous, Intravascular
2
Product Code
LLI
Bed, Therapeutic, Ac-Powered, Adjustable Home-Use
2
Product Code
LLK
Legging, Compression, Non-Inflatable
2
Product Code
LZH
Pump, Infusion, Enteral
2
Product Code
MDR
Binder, Medical, Therapeutic
1
Product Code
MEA
Pump, Infusion, Pca
2
Product Code
MEB
Pump, Infusion, Elastomeric
2
Product Code
MEG
Syringe, Antistick
2
Product Code
MHC
Needle, Interosseous
2
Product Code
MHD
Pump, Infusion, Gallstone Dissolution
2
Product Code
MJF
Check Valve, Retrograde Flow (In-Line)
2
Product Code
MMK
Container, Sharps
2
Product Code
MQX
Needle, Acupuncture, Single Use
2
Product Code
MRZ
Accessories, Pump, Infusion
2
Product Code
MZR
Topical Approximation System
1
Product Code
NEP
System/Device, Pharmacy Compounding
2
Product Code
NGT
Saline, Vascular Access Flush
2
Product Code
NKK
Needle, Hypodermic, Single Lumen, Reprocessed
2
Product Code
NKN
Syringe, Piston, Reprocessed
2
Product Code
NRW
Stimulator, Intramuscular, Automatic
2
Product Code
NSC
Injector, Pen
2
Product Code
NTC
Nursing Pad, Hydrogel
1
Product Code
NTX
Nursing Pad, Polyurethane Pad With Starch Copolymer, Glycerin, And Surfactant (F-68)
1
Product Code
NXH
Nursing Pad, Cohesive Gel
1
Product Code
NZG
Bassinet, Hospital
2
Product Code
NZW
Heparin, Vascular Access Flush
2
Product Code
NZX
Water, Vascular Access Flush
2
Product Code
OBK
Port, Protector/Cushion
2
Product Code
ODI
Administration Set Docking Station
2
Product Code
ODY
Tunneled Catheter Remover
2
Product Code
OJA
Intravenous Extension Tubing Set
2
Product Code
OKC
Implanted Subcutaneous Securement Catheter
2
Product Code
OKE
Port Introducer Kit
2
Product Code
OKL
Intravascular Administration Set, Automated Air Removal System
2
Product Code
OMF
Percutaneous, Implanted, Long-Term Intravascular Catheter Accessory For Catheter Position
2
Product Code
ONB
Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System
2
Product Code
ONM
Radiant Infant Warmer Cabinet
2
Product Code
PUK
Administration Set Securement Device
1
Product Code
OPP
Pump, Infusion, Insulin Bolus
2
Product Code
OSI
Bariatric Bed
2
Product Code
OUW
Infant Positioner, Rx, Use In Highly Monitored Setting
1
Product Code
OWL
Peripheral Catheter Insertion Kit
2
Product Code
PDH
Blanket, Neonatal Phototherapy
2
Product Code
PEF
Heparin Flush In 0.45% Sodium Chloride
2
Product Code
PEZ
Central Venous Catheter Dressing Change Kit
2
Product Code
PHC
Infusion Safety Management Software
2
Product Code
PKP
Immunoglobulin G (Igg) Infusion System
2
Product Code
PMS
Peripheral Intravenous (Piv) Infiltration Monitor
2
Product Code
PND
Midline Catheter
2
Product Code
POQ
Blood Transfusion Kit
2
Product Code
POR
Parenteral Administration Kit
2
Product Code
PQH
Iodinated Contrast Media Transfer Tubing Set
2
Product Code
PQX
Epinephrine Syringe
2
Product Code
PRN
Pediatric Position Holder
1
Product Code
PTD
Subcutaneous Implanted Apheresis Port
2
Product Code
PTI
Non-Coring (Huber) Needle
2
Product Code
PUN
Lice Removal Kit Containing A Solution
1
Product Code
PUR
Vacuum Syringe
2
Product Code
PVZ
Non-Stainless Steel Needle
2
Product Code
PWH
Administrations Sets With Neuraxial Connectors
2
Product Code
PWN
Baby Care Kit
2
Product Code
PWO
Blood Administration Kit
2
Product Code
PWQ
Buret Administration Intravenous Kit
2
Product Code
PWR
Catheter Repair Kit
2
Product Code
PWX
Insect Sting Emergency Kit
1
Product Code
PWY
Lumbar Puncture Tray (Adult & Pediatric)
2
Product Code
PXB
Percutaneous Introducer Kit
2
Product Code
PXI
Thoracentesis Tray
2
Product Code
PXJ
Umbilical Catheter Insertion Tray
2
Product Code
PXK
Vascular Access Port Kit
2
Product Code
PXL
Venipuncture Kit
2
Product Code
PYR
Neuraxial Administration Set - Intrathecal Delivery
2
Product Code
PZW
Catheter Access Cover, Tamper-Resistant
2
Product Code
QBL
Piston Syringe Lever
2
Product Code
QDM
Midazolam Syringe
2
Product Code
QEH
Piston Syringe With Neuraxial Connector – Epidural, Peripheral, And/Or Indirect Cerebral Spinal Fluid Contact
2
Product Code
QJY
Infusion Pump, Drug Specific, Pharmacy-Filled
2
Product Code
QLF
On-Body Injector
2
Product Code
QLY
Ophthalmic Syringe
2
Product Code
QMT
Prep Kit – Vaccine Injection
2
Product Code
QNQ
Low Dead Space Piston Syringe
2
Product Code
QNS
Low Dead Space Needle, Single Lumen, Hypodermic
2
Product Code
QOG
Injection Data Capture Device
2
Product Code
QOI
Intravenous Catheter Force-Activated Separation Device.
2
Product Code
QTI
Saline Vascular Access Flush With Integrated Alcohol Disinfectant Device
2
Product Code
QYM
Ophthalmic Needle
2
Product Code
SCL
Allergen And Vaccine Delivery Needles
2
Product Code
SEF
Central Venous Catheter With Manual Insertion System
2
Product Code
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
Subpart G—Miscellaneous Devices
CFR Sub-Part
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 13 June 2025 at 11:06 pm
HO
/
subpart-f—general-hospital-and-personal-use-therapeutic-devices
/
FPA
/
K935811
View Source
BOLUS DISPENSER
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K935811
510(k) Type
Traditional
Applicant
I-FLOW CORP.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
1/20/1995
Days to Decision
414 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—General Hospital and Personal Use Monitoring Devices
Subpart D—Pathology Instrumentation and Accessories
Subpart D—Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—General Hospital and Personal Use Therapeutic Devices
BRZ
Set, Blood Transfusion
BWJ
Locator, Acupuncture Point
CAK
Microfilter, Blood Transfusion
DWL
Stocking, Medical Support (To Prevent Pooling Of Blood In Legs)
FMF
Syringe, Piston
FMG
Stopcock, I.V. Set
FMI
Needle, Hypodermic, Single Lumen
FMS
Bed, Pediatric Open Hospital
FMT
Warmer, Infant Radiant
FMZ
Incubator, Neonatal
FNG
Lift, Patient, Ac-Powered
FNJ
Bed, Manual
FNK
Bed, Hydraulic, Adjustable Hospital
FNL
Bed, Ac-Powered Adjustable Hospital
FNM
Mattress, Air Flotation, Alternating Pressure
FNN
Nipple, Lambs Feeding
FOD
Device, Occlusion, Umbilical
FOH
Mattress, Water, Temperature Regulated
FOK
Pad, Neonatal Eye
FOS
Catheter, Umbilical Artery
FOZ
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
FPA
Set, Administration, Intravascular
K
24
2692
SteadiSet Infusion Set
K
24
2763
JetCan® Pro Safety Huber Needle
K
24
3529
Solution Administration Sets
K
24
2339
Intravascular Extension Sets and Accessories
K
24
1058
Lyka® PORT Needle Free Access Device (4170Y)
K
23
4129
Ecomed Disposable Administration Sets
K
24
2126
I.V. Administration Set
K
23
2475
Disposable infusion set with needle
K
22
2766
Disposable Extension Set
K
23
2328
Insignis™ Syringe Infusion System
K
23
1707
ResQ Administration Set
K
23
0528
Extension Set
K
22
2780
LILY Extension Tube and Needleless Connector
K
23
0343
ProSeal™ Closed System Administration Set
K
22
1327
BD Alaris™ Pump Infusion Sets
K
22
1411
Surflo Winged Infusion Set
K
22
1121
Volumat Polyethylene I.V. Administration Set
K
23
0992
DJF Intravascular Administration Set
K
22
0301
Volumat Line
K
22
3645
I.V. Administration Set, I.V. Extension Set
K
22
3101
BD Secondary Infusion Set
K
22
0288
NP Medical nPulse K150 Neutral Displacement Needle Free Connector, nPulse Neutral displacement needle free connector, nPulse K150 Needle Free Connector
K
22
0312
Polyfusion IV Administration Sets
K
22
3088
BD SmartSite™ Needle-Free Connector
K
22
2889
FlowArt® Needle-Free Split Septum Valve
K
22
1069
Infusion Sets for Single Use with Needles
K
22
1075
Infusion Sets for Single Use
K
22
1078
Intravenous Needles for Single Use,Safety Intravenous Needles for Single Use
K
22
1518
NP Medical nCompass Extension Set with Stabilizing Base
K
22
0267
AMSafe NeuFlo Needleless Connector
K
21
2262
PCA Syringe Sets
K
22
1473
Flowart
K
22
1481
NeutrArt
K
21
3846
Q2 Blood Administration Sets
K
21
3588
Q2 IV Administration Sets
K
21
3004
Needle Free Connector
K
20
2437
Infusion Sets for Single Use
K
21
3778
IV Administration Set
K
21
2842
Microvolume Luer Access Device
K
21
3089
Ivenix Infusion System, LVP Epidural Administraion Set NRFit Connector
K
20
3609
Intravascular Administration Sets
K
20
2618
IV Administration Sets
K
21
0381
I.V. Administration Set
K
20
2279
Insignis Subcutaneous Needle Sets
K
20
3796
Firefly Needleless Connector
K
21
0544
Medtronic Extended infusion set
K
21
0430
Intravascular Extension Set
K
21
0217
Needleless Connector
K
20
1626
Safety Subcutaneous Infusion Set
K
20
0439
Velano ExT Extension Set
K
20
2672
Precision Delivery Infusion Set
K
20
1872
NeutrArt
K
20
0425
Female Luer Lock Cap
K
19
3088
MaxZero Extension Sets with Needle-Free Connector(s)
K
20
0661
Steripath Micro Blood Collection System
K
19
2375
Intellifuse Administration and Intellifuse Blood Administration Sets
K
19
1640
TK Intravascular Administration Set
K
19
2681
Safety scalp vein set, Scalp vein set, Blood collection needle (Scalp vein set type), Blood collection needle (Needle holder type), Safety blood collection needle (Scalp vein set type), Safety blood collection needle (Needle holder type)
K
19
2366
Intravascular Extension Sets and Accessories
K
19
1362
LifeFlow Blood System
K
19
1658
IV Sets not made with PVC
K
19
0806
Flowart
K
19
2647
neria guard Infusion Set
K
18
0739
Clearlink System Solution Set
K
19
0233
K-Shield Advantage Port Access Infusion Set (PAIS)
K
18
0843
HIgH-Flo Super26 Subcutaneous Needle Sets
K
18
2897
Velano Vascular Q2 Extension Set
K
18
1870
Infusion Sets with Precision Filter for Single Use, Precision Infusion Filter for Single Use, Extended Infusion Sets for Single Use
K
18
2545
Tamper Evident Cap with Male Luer Lock
K
18
1718
BD FlowSmart Set/MiniMed Pro-Set
K
17
3665
AMSafe Sure-Lok Needle-Free Connector
K
17
3361
IV Administration Set
K
17
3879
MiniMed Mio Advance infusion set
K
17
0595
IV Administration Sets
K
16
2812
Unomedical Comfort Subcutaneous Infusion Set, Unomedical Comfort Short Subcutaneous Infusion Set, Unomedical Neria Soft Subcutaneous Infusion Set, Medtronic Silhouette Subcutaneous Infusion Set, Medtronic Silhouette Paradigm Subcutaneous Infusion Set, Roche Accu-Chek Tender Subcutaneous Infusion Set, Asante Comfort Subcutaneous Infusion Set, Abbott Comfort Subcutaneous Infusion Set
K
17
2544
IV Fat Emulsion Administration Sets
K
17
0002
Medline Blood Collection Set
K
17
1117
Carefusion NeutraClear Needle-free connector (EL-NC1000)
K
17
1118
Carefusion NeutraClear multi-fuse Extension Set with needle-free connector(s)
K
17
1132
Carefusion NeutraClear Needle-free connector
K
16
2951
TUBETECH IV Administration Set
K
17
1957
MaxZero Extension Sets with Needless Connector
K
16
1808
Solution Set with 1.2 Micron Air Eliminating Filter
K
16
2826
Encore Neutral
K
17
1101
Closed Male Luer
K
16
2601
Infusion Set for Single Use
K
16
3160
Sterile Single-use Infusion Set
K
16
2804
Q2 Low Pressure Power Injection Extension Set
K
16
1898
Burette-type Infusion Sets for Single Use, Disposable Infusion Sets with Precision Filters, Disposable Infusion Set
K
16
1036
Hospira Extension Set, Hospira Primary Set
K
16
0007
Paclitaxel Sets
K
16
2304
Q2 Multiport IV Administration Sets and Extension Sets, Checkmate Multiport IV Administration Sets, Q2 Extension Sets
K
16
1323
Solution Set for Epidural Use
K
15
3731
LifeFlow Rapid Infusion Device (LifeFlow Device)
K
15
3440
PowerLoc MAX Power Injectable Infusion Set, SafeStep Huber Needle Set
K
16
0648
MiniMed Quick-Set® MiniMed Sure-T® MiniMed Silhouette® MiniMed Mio®
K
15
1250
Smart Set
K
16
0870
Hospira Administration Sets
K
15
0921
Orbit Infusion Set
K
16
0651
BD FlowSmart Set, MiniMed Pro-Set
K
15
3293
Extension Set
K
15
1969
Hospira Extension Sets
K
15
3158
Solution Administration Sets with 0.2 Micron Filter
K
15
2323
Disposable Infusion Needle, Safelock Disposable Infusion Needle
K
15
3257
BD FlowSmart Set, MiniMed Pro-Set
K
15
1991
Safelock Disposable Blood Collection Set, Disposable Blood Collection Set
K
15
1079
Q2 Intravenous Adminstration Sets and Extension Sets
K
15
1151
U & U Intravascular Administration Set
K
14
3446
Accu-Chek FlexLink Plus infusion set
K
14
3082
IV Administration Sets with 200(micro)m Blood Filter
K
15
0513
Imed Technology Intravascular Administration Set, Imed Technology Extension Set
K
15
0059
BD FlowSmart Set
K
15
0860
Nitroglycerin Sets with DUO-VENT Spike
K
14
3087
Hospira Blood Set
K
14
3015
Hospira Primary Sets
K
14
1285
BUSSE EXTENSION SET
K
14
2590
All Safe Huber Safety Infusion Set
K
14
2622
IV Administration
K
14
2974
Extension Sets
K
14
2433
Hospira Extension Set
K
14
0838
IV ADMINISTRATION SET WITH HAND PUMP
K
14
2367
Hospira Primary Sets
K
14
3234
MaxZero Administration Sets
K
14
1200
PADI-LOCK
K
14
2527
Extension Set with BD Q-Syte Luer Access Split Septum
K
14
2097
SELEC-3 I.V.ADMINISTRATION SET
K
14
2036
INFUSOMAT SPACE VOLUMETRIC INFUSION PUMP ADMINISTRATION SETS
K
14
2011
SOLUTION SET/EXTENSION SET
K
14
1834
SAPPHIRE ADMINISTRATION SET
K
14
0175
INTRAVASCULAR ADMINISTRATION SET
K
14
1306
TEVADAPTOR; CONNECTING SET W/ ULTRASITE INJECTION SITE, SPIKE PORT ADAPTOR SET W/ ULTRASITE INJECTION SITE
K
13
3351
NEXUS NIS-6P LUER ACTIVATED DEVICE
K
14
0133
INFUSET FLOW CONTROL EXTENSION SET
K
14
0311
CARESITE LUER ACCESS DEVICE
K
14
0831
MAXZERO EXTENSION SET WITH NEEDLESS CONNECTOR
K
14
0131
SUB-Q SUBCUTANEOUS TISSUE INFUSION SET
K
13
3073
CAIR DRIVE, NEUTRACLEAR
K
13
3894
SURFLO WINGED INFUSION SET WITH FILTER & NEEDLE PROTECTION (SURSHIELD)
K
13
3867
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD)
K
13
2841
ZYNO MEDICAL ADMINISTRATION SET
K
13
2880
MEDCOMP POWER INJECTABLE SAFETY HUBER NEEDLE
K
13
2734
NEUTRAL LUER ACTIVATED DEVICE (ONE-LINK NEEDLE-FREE IV CONNECTOR) AND EXTENSION SETS
K
13
2142
NERIA SOFT 90 INFUSION SET
K
13
2413
MZ1000
K
13
0879
NEXUS IV TUBING SET WITH LUER-ACCESSBILE ONE-WAY CHECK VALVE - IV PLUS
K
13
0416
NEXUS TKO-6P LUER ACTIVATED DEVICE
K
12
2404
MODEL NUMBER: RMS1-2604, RMS1-2614, RMS1-2404, RMS1-2414, RMS2-2604, RMS2-2614, RMS2-2404, RMS2-2414, RMS3-2604, RMS3-26
K
13
0023
K100 NEUTRAL DISPLACEMENT NEEDLE FREE CONNECTOR
K
13
0468
ORBIT INFUSION SET
K
12
3344
K-SHIELD ADVANTAGE PORT ACCESS INFUSION SET (PAIS)
K
12
1511
MACLIN POWER INTRAVASCULAR ADMINISTRATION SET
K
12
1269
TBA
K
12
3874
INTERLINK SYSTEM BURETROL SOLUTION SETS, INTERLINK SYSTEM BURETROL SOLUTION SETS, CONTINUED, CLEARLINK SYSTEM BURETROL S
K
12
3868
INTERLINK SYSTEM LEVER LOCK CANNULA WITH CHECK VALVE, SECONDARY MEDICATION SETS, SOLUTION SETS, CONTINU-FLO SOLUTION SET
K
12
3729
VERSARATE FLOW RATE CONTROLER
K
12
1803
INTRAVASCULAR ADMINISTRATION SET
K
12
2686
ACCU-CHEK ULTRAFLEX INFUSION SET
K
11
3471
NIPRO HUBER INFUSION SET, EXCEL HUBER INFUSION SET
K
11
3470
NIPRO SAFE TOUCH HUBER INFUSION SET
K
11
2204
KDL DISPOSABLE INFUSION SET
K
12
0685
ZYNO MEDICAL ADMINISTRATION SET
K
12
0195
SAFETY SUBCUTANEOUS TISSUE INFUSION SET
K
12
1634
INTERLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATORY CLEARLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATOR
K
12
1092
FLOWEASE [SUBCUTANEOUS] INFUSION SET
K
12
0375
MED-RX PATIENT DELIVERY SET
K
12
1032
PRIMARY SYMBIQ SET, DITAL MICROBORE TUBING, 0.2 MICRON FILTER, NON-DEHP
K
12
1554
Q-FLO CLOSED MALE LUER CONNECTOR
K
12
0395
NERIA MULTI SUBCUTANEOUS INFUSION SET
K
12
0443
NEUTRAL LUER ACTIVATED DEVICE AND EXTENSION SETS WITH NEUTRAL LUER ACTIVATED DEVICE
K
12
0548
HLIC NEEDLE-LESS VALVE
K
12
0261
PPS PI PRESSURE INJECTABLE SAFETY HUBER NEEDLE WITHOUT LATERAL INJECTION SITE, PPS PI PRESSURE INJECTABLE SAFETY HUBER
K
12
0872
ASANTE CONSET AND ASANTE COMFORT SUBCUTANEOUS INFUSION SETS FOR USE WITH ASANTE PEARL INFUSION PUMPS
K
11
3398
NEXUS TKO-6, LUER-ACTIVATED DEVICE
K
11
2073
INFUSITE NEEDLELESS ACCES DEVICE (STERILE, BULK NON-STERILE) AND INFUSITE NEEDLELESS ACCESS DEVICE 'Y' ADAPTER (BULK...
K
12
0799
ARISURE NEUTRAL VALVE
K
11
3683
LIFESHIELD VISION INFUSION SET WITH PRE-PIERCED RESEAL
K
11
2799
MED-RX EXTENSION SET WITH T-CONNECTOR
K
11
2636
CYTOGUARD(TM) CLOSED LUER CONNECTOR
K
11
2512
VANISHPOINT BLOOD COLLECTION SET
K
11
2893
CLEARLINK LUER ACTIVATED VALVE, CLEARLINK SYSTEM NON-DEHP CATHETER EXTENSION SETS
K
11
1351
TRUECARE BIOMEDIX INTRAVASCULAR ADMINISTRATION SET, TRUECARE BIOMEDIX EXTENSION SET
K
10
2405
INFUSION SET FOR POWERPICC SOLO 2 CATHETER
K
10
3562
CENTURION PRESSURE INJECTABLE EXTENSION SET
K
11
1016
SAFEPORT MANIFOLD (TM) (OR STOPCOCK)
K
10
2512
RMS SUBCUTANEOUS NEEDLE SET
K
11
0282
LIGHTY DD INFUSION SET
K
10
3551
INTERLINK S / CLEARLINK SYSTEM / V-LINK LAD WITH VITALSHIELD PROTECTIVE COATING NON-DEHP CATHETER EXTENSION SET KITS,
K
10
3224
HOSPIRA PLUM INFUSION SET; HOSPIRA INFUSION SET WITH YELLOW STRIPE TUBING
K
10
0576
HIGH PRESSURE SETS-400 PSI
K
10
3344
INFUSION SETS
K
10
1368
D. HEART MEDICAL INTRAVASCULAR ADMINISTRATION SET, SAFETY ACCES DEVICE AND ACCESSORIES
K
10
0720
K-SHIELD PORT ACCESS INFUSION SET WITH HIGH PRESSURE TUBING
K
10
3165
BLOOD SAMPLING SET
K
10
2073
MED-RX TRANSFER SET, MODELS 10-1227TS, 10-1300TS, 10-1305TS AND 10-1306TS
K
10
2890
K-SHIELD SMALL VEIN INFUSION / WINGED COLLECTION SET W/ ANTI NEEDLE STICK PROTECTOR (AND MULTISAMPLE LUER ADAPTER)
K
10
1958
AMSINO I.V. ADMINISTRATION AND EXTENSION SETS
K
10
1196
ACCU-CHEK ULTRFLEX INFUSION SET
K
10
1677
HOSPIRA INFUSION BLOOD SETS
K
10
1180
GRIPPER MICRO BLUNT CANNULA, NON-CORING SAFETY NEEDLE (GRIPPER MICRO NEEDLE) MODEL: 21-3253-24, 21-3258-24, 21-3262-24,
K
10
0946
INTRAVSCULAR ADMINISTRATION SET
K
09
3489
IN VISION-PLUS NANO WITH NEUTRAL ADVANTAGE TECHNOLOGY
K
10
0432
POLYFIN INFUSION SET, MODELS MMT-165, MMT-365, MMT-366, MMT-312S AND MMT-312L AND SOF-SET INFUSION SETS
K
10
0434
CLAVE NEUTRON
K
10
1385
DUAL LUER LOCK CAP, MODEL 2C6250
K
09
2382
NEXUS PRESSURE RATED EXTENSION SETS
K
09
3773
AMSINO I.V. ADMINISTRATION SET, AMSAFE3 I.V ADMINISTRATION SET, EXTENSION SETS
K
09
2930
NEXUS INTRAVASCULAR TUBING SETS-PRE-PIERCED
K
09
2905
AUTOSTART BURETTE
K
09
2527
NEXUS INJECTION SITE, MODEL NIS-8
K
09
3271
EXTENSION SET (STANDARDBORE TUBING), EXTENSION SET (MINIBORE TUBING), IV ADMINISTRATION SET ( STANDARD
K
09
2172
EXEL I.V. EXTENSION SET
K
09
0459
DISPOSABLE TPE INFUSION SET
K
09
0012
DISPOSABLE INFUSION SET
K
08
3687
BAIXIN INTRAVASCULAR ADMINISTRATION SET
K
08
3723
A6 LUER ACCESS DEVICE
K
09
0809
MPS ACACIA POWER INJECTABLE INFUSION SET
K
09
0134
INTRAVENOUS POWER INJECTOR EXTENSION SET
K
09
0189
ANTIMICROBIAL CLAVE, MODELS AG CLAVE, AG MICROCLAVE
K
08
2806
SPINNING SPIROS, MODEL CH-2000
K
08
3482
COOK VASCULAR VITAL-JECT POWER INJECTABLE SAFETY INFUSION SET
K
08
2027
FLU-ADMIN, MODELS 60150, 60150C, 60151C, 60153C, 60160
K
08
3765
MAXGUARD ADVANCED LUER ACTIVATED DEVICE WITH ANTIMICROBIAL
K
08
3576
MISER CONTRAST MANAGEMENT SYSTEM
K
08
2818
SUBCUTANEOUS NEEDLE INFUSION SET
K
08
3472
MEDEGEN PRESSURE RATED EXTENSION SETS
K
08
1123
NEXUS I.V. NEEDLESS ACCESS CANNULA FOR INTRAVASCULAR ADMINISTRATION SETS
K
08
1210
NIPRO SAFETOUCH HUBER INFUSTION SET
K
08
2306
POWERLOC CLEAR SAFETY INFUSION SET
K
08
1361
CHEMOCLAVE CYTOTOXIC MEDICATION PREPARATION AND DELIVERY SYSTEM, MODEL, CH-XXXX
K
07
3444
TRITON MEIDCAL TMED IV-SET
K
08
0544
UNASSIGNED
K
07
3396
ANTIMICROBIAL ULTRASITE VALUE, ULTRASITE AG
K
08
0303
EZ REGULAR
K
08
1289
V-LINK ANTIMICROBIAL LUER ACTIVATED DEVICE AND EXTENSION SETS WITH V-LINK ANTIMICROBIAL LUER ACTIVATED DEVICE
K
08
1156
CADD MEDICATION CASSETTE RESERVOIR
K
08
0695
MOBILE I.V. SYSTEMS 10,20,60
K
08
0665
NOVOLET
K
08
0660
IV ADMINISTRATION SET
K
07
3050
SAFESTEP MAX POWER-INJECTABLE INFUSION SET
K
07
2375
SMARTPORT CT MP PORT ACCESS SYSTEM AND LIFEGUARD CT SAFETY INFUSION SET
K
07
2894
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD)
K
07
2576
CLEARLINK ANTIMICROBIAL LUER ACTIVATED DEVICE (LAD) AND EXTENSION SETS WITH THE CLEARLINK ANTIMICROBIAL LUER ACTIVATED
K
06
3631
POLYPERF / POLYPERF SAFE
K
07
1421
PROMEPLA INTRAVASCULAR ADMINISTRATION SET AND EXTENSION SET
K
07
2542
MAXPLUS TRU-SWAB POSITIVE DISPLACEMENT CONNECTOR
K
07
0630
HEALTH LINE INTERNATIONAL CORPORATION'S PRIMARY IV SOLUTION ADMINISTRATION SET WITH CHECK VALVE
K
07
1846
MODIFICATION TO EZ HUBER SAFETY INFUSION SET
K
07
0547
SURFLO WINGED INFUSION SET WITH FILTER AND NEEDLE PROTECTION (SURSHIELD)
K
07
0801
IMM HYPODERMIC NEEDLE SET
K
07
0362
SURFLO WINGED INFUSION SET
K
07
0430
PARADIGM QUICK-SET II AND QUICK-SET II SUBCUTANEOUS INFUSION SETS
K
07
0532
SPIROS
K
06
2308
LMT-KATH-S; LMT-KATH-I
K
06
2909
REPEATER PUMP II TUBE SETS
K
07
0189
ACCU-CHEK ULTRAFLEX INFUSION SET
K
06
1374
INTUITION INFUSION SETS
K
06
1285
SMARTSITE NEEDLE FREE VALVE ADMINISTRATION SETS
K
06
1771
EZ-CONNECT
K
06
1115
SPEEDFLOW 0.2UM FILTER, MODEL 11214; SPEEDFLOW 1.2UM FILTER, MODEL 11215; EASYDROP CONTROLLER, MODEL 11216
K
06
0488
DERMATECH IV HOLDER
K
06
0580
K-SHIELD PORT ACCESS INFUSION SET
K
06
0352
HEALTH LINE INTERNATIONAL CORPORATIONS,S IV ADMINISTRATIVE SETS
K
06
0672
ONE STICK Y EXTENSION SET AND VOLUMETER
K
06
0082
TIANJIN MEDIS DISPOSABLE INFUSION SET
K
06
0074
INTERLINK SYSTEM-T-CONNECTOR EXTENSION SET, MODEL 2N3326
K
05
3049
ALARIS SAFETY MALE LUER
K
05
3106
TEGO, MODEL D1000
K
05
3129
NEXUSTKO NEEDLELESS ACCESS DEVICE, MODEL NIS-5
K
05
2887
SURFLO WINGED INFUSION SET WITH NEEDLE PROTECTION (SURSHIELD), MODEL SV-S23BL35VS
K
05
2432
MEDTRONIC MINIMED PARADIGM LEAPFROG II INFUSION SET, MODELS MMT-802S1, MMT-802L1, MMT-802S2, MMT-802L2
K
05
2252
CONTRAST MEDIA TRANSFER SETS
K
05
2722
LIFESHIELD LATEX-FREE MICROBORE EXTENSION SET, MODEL 14949 AND OTHERS
K
05
2658
SELECTFLOW - INTRAVASCULAR ADMINISTRATION SET
K
05
1943
SUREFLOW SAFETY INFUSION DEVICE
K
05
1264
COMFORT AND INSET SUBCUTANEOUS INFUSION SETS FOR USE WITH ABBOTT INFUSION PUMPS
K
05
0906
VITALCARE I.V. ADMINISTRATION SET
K
05
1437
CML 1000
K
05
1939
MAXPLUS TRU-SWAB POSITIVE DISPLACEMENT CONNECTOR
K
05
1142
ANGIODYNAMICS TUMESCENT INFUSION DEVICE
K
05
1009
HUBER CLEAR SAFETY INFUSION SET
K
05
1499
INTRAVASCULAR ADMINISTRATION SET AND EXTENSION SET
K
05
0600
MINILOC SAFETY INFUSION SET
K
04
3328
MICROFLO-SAFE SCALP VEIN SET
K
04
1495
PENTADEFLUE IV SOLUTION ADMINISTRATION SETS
K
05
0207
BD POSIFLOW POSITIVE DISPLACEMENT VALVE
K
04
3235
DRAGON HEART I.V. SET
K
04
2129
F00010 - IV GRAVITY SETWITH MALE LUER SLIP; F00027 - IV GRAVITY SET WITH MALE LUER LOCK
K
04
2666
LUTH-ALL SUB-Q NEEDLE SET
K
04
2936
SOLUTION ADMINISTRATION WITH LUER ACCESS INJECTION SITE
K
04
1861
NEXUS INTRAVENOUS TUBING SETS (NIVTS)
K
04
1490
IV ADMINISTRATION SETS WITH ULTRABLOCK UV-RESISTANT TUBING
K
04
2693
IV ADMINISTRATION SET B400 SP
K
04
2172
CLEO 90 INFUSION SET
K
04
1919
PERFUDROP AIR M-P WITH NEEDLE 20 G, MODEL 48451606
K
04
0533
EZ HUBER SAFETY INFUSION SET
K
04
2234
MODIFICATION TO: LIFTLOC SAFTEY INFUSION SET
K
04
1844
ALL SAFE HUBER SAFETY INFUSION SETS
K
04
2182
Y CLAVE CONNECTOR WITH INTEGRATED CHECK VALVE, MODEL XI-3432
K
04
1845
NEXUS PAV LUER LOCK DEVICE, MODEL NIS-4
K
04
0710
TEGO NEEDLE FREE ACCESS ACCESS DEVICE
K
04
1410
PUNCTUR-GUARD WINGED SET FOR BLOOD COLLECTION, MODEL 5118
K
04
1042
SPLIT SEPTUM INJECTION SITES
K
04
1545
CONTACT DETACH
K
04
1179
MODIFICATION TO THE NAC PLUS NEEDLELESS ACCESS CONNECTOR
K
03
2767
LILY VOLUME METERIC ADMINISTRATION SET, MODELS IB-2111 AND CIB-120ES
K
04
0636
CADD ADMINISTRATION SET WITH FLOW STOP, MEDICATION CASSETTE RESERVOIR WITH FLOW STOP AND EXTENSION SET
K
03
3290
TALON INFUSION SET, MODEL IP XXXX
K
04
0385
MULTIPORT MANIFOLD SET WITH SWABABLE VALVES, MODEL 9900
K
04
0633
CLICK-ON
K
04
0527
LOW PROFILE LUTHER SAFETY HUBER
K
03
3208
IVY DEVICES INC. IV/MEDICAL LINE STABILIZER
K
03
3892
ULTRAFLEX INFUSION SET
K
03
3301
IV ADMINISTRATION AND CONNECT SETS
K
03
3515
HUBERPRO SAFETY HUBER INFUSION SET
K
03
3576
LIFESHIELD LATEX-FREE PRIMARY IV PUMP SET DISTAL MICROBORE PATIENT LINE, CONVERTIBLE PIN, 72 INCH, WITH 2 PRESSURE
K
02
1692
CLC2000 CATHETER PATENCY DEVICE
K
03
3350
BD VACUTAINER SAFETY-LOK ADMINISTRATION SET WITH FILTER
K
03
2934
MPS ACACIA SAFEGUARD HUBER DEVICE
K
03
2484
MEDTRONIC MINIMED PARADIGM COUNTACH INFUSION SET, MODEL MMT 310
K
03
2485
MEDTRONIC MINIMED COUNTACH INFUSION SET, MODEL 313
K
03
3099
ADR THINSET INFUSION SET MODEL, 23-106, 23-109, 43-106, 43-109
K
03
2854
UNOMEDICAL MONICA INFUSION SET
K
03
2150
SAFETY-MULTIFLY
K
02
1471
MARQUETTE HUBER TRAP SAFETY INFUSION SET
K
02
0424
V SET
K
02
0419
V SET
K
03
1917
MEDTRONIC MINIMED PARADIGM POLYFIN QR, MODEL MMT 312L AND 312S
K
03
1923
ULTRASITE VALVE
K
03
1500
EXCEL PRIMARY SOLUTION SET
K
03
1783
SAFE-CONNECT DRUG DISPENSING SPIKE, MODELS SC 4020, SC 4015, SC 4010, SC 4005
K
02
3668
JMS EXTENSION SET WITH PLANECTA, PLANECTA (STAND ALONE UNIT), PLANECTA LOCK & PLANECTA ADAPTOR
K
03
1279
SURSHIELD SAFETY WINGED BLOOD COLLECTION SET
K
03
1266
SURSHIELD SAFETY WINGED INFUSION SET
K
03
1361
CADD HIGH-VOLUME ADMINISTRATION SETS WITH FLOWSTOP
K
03
0385
IV ADD-ON FILTER ADMINISTRATION SET WITH AND WITHOUT Y CONNECT OR NEEDLELESS ACCESS CONNECTOR
K
02
0189
EXEL BUTTERFLY SCALP VEIN SET
K
03
0149
MEDTRONIC MINIMED SOF-SITE INFUSION SET, MODELS MMT-359S6, MMT-359M6, MMT-359L6, MMT-359S9, MMT-359M9, AND MMT-359L9
K
03
0467
GRAVITECH TM FLOW CONTROLLER PRIMARY SET/GRAVITECH FLOW CONTROLLER EXTENSION SET
K
03
0246
VICTUS I.V. ADMINISTRATION SET, MODELS 27071 AND 27072
K
02
3917
WINGED NEEDLE SETS WITH AN ANTINEEDLE STICK PROTECTOR
K
03
0137
MEDTRONIC MINIMED SOF-SITE INFUSION SET, MODELS MMT-358S6, MMT-358M6, MMT-358L6, MMT-358S9, MMT-358M9, AND MMT-358L9
K
02
4363
NEXUS INJECTION SITE (NIS), MODEL NIS-1
K
03
0002
LIFESHIELD PRIMARY IV SET CONV. PIN. CLAVE; LF LC 5000 PLUMSET-DUAL W/CONV PIN & CAP PORT; LIFESHIELD LF MACROBORE EXT.
K
02
3769
PREPARE ADMINISTRATION SET
K
02
3595
BURETTE-IN LINE (150 ML)
K
02
3469
VICTUS I.V. ADMINISTRATION SET, MODELS 27058, 27059,27062
K
02
0533
EXEL VACULET BLOOD COLLECTION SET
K
02
3585
FLOSTAR NEEDLELESS CONNECTOR, MODEL FS3000
K
02
1565
LUTHER SAFETY HUBER NEEDLE SET
K
02
1916
HARMAC HUBER NEEDLE SAFETY DEVICE, H2984001
K
02
1080
NONCOR INFUSION SETS; NONCOR PORT INFUSION SETS
K
02
1999
GRIPPER PLUS NEEDLE
K
02
2209
ALARIS MEDICAL INFUSION SYSTEM ADMINISTRATION SETS
K
02
0926
EXTENSION SET, MODELS 1911-512
K
02
1488
SURECAN SAFETY HUBER NEEDLE INFUSION SETS
K
02
1480
EXTENSION SET LIGHT-SAFE, MODEL BC565
K
02
1530
SIMPLICITY EASY P SOFT INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE OF THE SKIN
K
02
1487
SIMPLICITY EASY ACCESS P INFUSION SET
K
02
1296
SIMPLICITY QD EASY P INFUSION SET
K
02
1395
MODIFICATION TO 30 EXTENSION SET
K
02
1216
SIMPLICTY SIMPLEX P INFUSION SET FOR USE WITH THE MINIMED PARADIGM INFUSION PUMPS
K
02
0530
EVANS SUB-Q, MODEL MC4206
K
02
1005
SIMPLICITY EASY ACCESS II INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE
K
01
3621
BD SAF-T PRN LUER ACTIVATED VALVE, MODEL 385100
K
02
0990
SIMPLICITY SOFT QD II INFUSION SET FOR INFUSION AND/OR INJECTION OF FLUIDS INTO THE BODY BELOW THE SURFACE OF THE SKIN
K
02
0912
SIMPLICITY EASY SOFT INFUSION SET
K
02
0629
SIMPLICITY SIMPLEX SOFT INFUSION SET
K
01
3871
LIFEGUARD SAFETY INFUSION SET
K
01
3714
CODAN US I.V. ADMINISTRATION SET, MODEL B400 SP
K
01
3949
UNIVERSAL VIAL ACCESS SPIKE WITH NEEDLELESS CONNECTOR
K
02
0544
WING SAFE INFUSION SET 20 GA, SHS2000 SERIES; WING SAFE INFUSION SET 19 GA, SHS1900 SERIES; WING SAFE INFUSION SET 22 GA
K
01
4062
SIMPLICITY EASY ACCESS INFUSION SET
K
01
4061
SIMPLICITY STARPLUS SOFT INFUSION SET
K
01
2879
EXEL HUBER INFUSION SET WITH NEEDLELESS INJECTION SITE
K
01
3950
VENTED VIAL ACCESS DEVICE
K
01
3502
SIMPLICITY CLASSIC WING QD INFUSION SET
K
01
3394
LIFTLOC SAFETY INFUSION SET
K
01
2429
SURESET INFUSION SET, MODEL 8023
K
01
3164
SURSHIELD SAFETY WINGED BLOOD COLLECTION SET
K
01
3104
SIMPLICITY QD SOFT INFUSION SET FOR USE BY PEOPLE WITH DIABETES IN INFUSE INSULIN SUBCUTANEOUSLY FROM A PUMP OR SYRINGE
K
01
1405
EXEL INJECTION PLUG WITH CAP
K
01
2845
SIMPLICITY SOFT QD MICRO INFUSION SET
K
01
2526
BIOTEQUE SCALP VEIN SET
K
01
1888
PRESSURE ACTIVATED CHECK VALVE
K
01
0404
EXEL I.V. ADMINISTRATION SET
K
01
2754
EZ SET INFUSION SET
K
01
2330
SIMPLICITY EURO QD INFUSION SET
K
01
1928
HYDROTOWER ARTHROSCOPIC ADMINISTRATION TUBING SET, MODEL 7-460-05
K
01
1216
PVC FREE INTRAVASCULAR ADMINISTRATION SET
K
00
3254
CORTEZ NEEDLE FREE IV CONNECTOR, MODEL MMD-001
K
01
0888
SIDEPORT PINCH CLAMP DEVICE
K
01
1858
INTERLINK THREADED LOCK CANNULA
K
01
1187
SIMPLICITY SOFT YP INFUSION SET FOR USE WITH THE MINIMED PARAGIGM INFUSION PUMPS
K
01
1336
PRIMARY SOLUTION SET WITH UNIVERSAL SPIKE, INJECTION SITE AND MALE LUER LOCK
K
01
1193
NAC PLUS NEEDLELESS ACCESS CONNECTOR
K
01
1071
PARADIGM QUICK-SET INFUSION SET
K
01
1580
SIMPLICITY SOFT QD SILVER INFUSION SET
K
01
0279
MEDISYSTEMS LUER ACCESS INJECTION SITE
K
01
0197
EXEL SECURE TOUCH SAFETY (P.S.V.) SCALP VEIN SET
K
01
1120
GLUCOPRO INFUSION SET, MODEL GPISXXXXXXXX SERIES
K
01
0886
SIMPLICITY WING INFUSION SET
K
01
1003
SAFESTING AND SAFESTING HUB
K
01
0788
SIMPLICITY SOFT QD EASY INFUSION SET
K
01
0676
SIMPLICITY WINGED QD INFUSION SET
K
01
0647
SIMPLICITY INFUSER INFUSION SET
K
01
0846
SIMPLICITY SILVER SET SOFT INFUSION
K
00
0592
UNOLOK PLUS INFUSION SET AND VAKU-8 PLUS BLOOD COLLECTION SET
K
01
0538
PARSET NEEDLELESS PRIMARY SET FOR BLUNT CANNULA, A10003E, PARSET NEEDLELESS SECONDARY SET WITH BLUNT CANNULA, A14003E
K
01
0103
SURSHIELD WINGED INFUSION SET
K
01
0373
SIMPLICITY SOFT Y INFUSION SET FOR USE WITH THE MINIMED INFUSION PUMPS AND MINIMED MEDICATION RESERVOIRS (MODEL MMT-103)
K
00
2689
SWABSITE SWABBABLE VALVE, MODEL 245000
K
00
3977
DISETRONIC RAPID SUBCUTANEOUS INFUSION SET AND DISTERONIC RAPID D SUBCUTANEOUS INFUSION SET
K
00
1329
INTRAVASCULAR IV SET, IV SET WITH BURETTE, EXTENSION SET
K
00
3854
INTRAVASCULAR ADMINISTRATION SET
K
00
3513
TAXOL ADMINISTRATION SET
K
00
2449
BIOTEQ I.V. (INTRAVENOUS) SET
K
00
3283
SIMPLICITY WITH WINGS INFUSION SET, (MODEL MMT-103)
K
00
1233
ACTI-FLEX FLUID DELIVERY SYSTEM OR ACTI-FLEX F D S
K
00
2492
SIMPLICITY SOFT INFUSION SET
K
00
3225
SOLUTION ADMINISTRATION SETS WITH CAPLESS LUER ACTIVATED VALVE
K
00
2471
JETCAN HUBER NEEEDLE SET
K
00
1599
ACTI-FLEX IV ADMINISTRATION SET
K
00
1872
I.V. SET-LUER LOCK WITH LATEX FREE INJECTION SITE, MODEL B411
K
00
2138
PARADIGM SILHOUETTE, MODELS MMT-377, 378, 379, 380
K
00
1827
PARADIGM SOF-SET MICRO QR, MODELS 324 AND 325
K
00
1832
PARADIGM SOF-SET ULTIMATE QR, MODELS 317 AND 318
K
00
1106
MASTERSITE NEEDLELESS LUER ACTIVATED IV CONNECTOR, MODEL MS 1000
K
00
2006
LIFESHIELD ADDITIVE PIERCING PIN
K
00
1426
KAWASUMI LABORATORIES IV ADMINISTRATION SET WITH FILTER
K
00
1423
KAWASUMI LABORATORIES IV ADMINISTRATION SET, PRIMARY
K
00
1424
KAWASUMI LABORATORIES IV ADMINISTRATION SET, STANDARD
K
99
0331
SURGEN VALVE
K
00
0472
POSI-LINK
K
00
0942
CADD CHECKVALVE ADMINISTRATION SET, MODEL 21-7090
K
00
1102
PARSET PRIMARY SET WITH CHECK VALVE, MODEL A10002E
K
99
4429
VENUSA, LTD. EXTENSION SET WITH FILTER
K
00
0343
NAC Y-ADP
K
00
0152
KIPPMED I.V. MANIFOLD
K
99
2290
EXEL INJECTION PLUG WITH CAP
K
00
0017
PARSET SECONDARY ADMINISTRATION SET, LUERLOCK, MODEL A14001E, PARSET SECONDARY SECONDARY ADMINISTRATION SET, MODEL A1400
K
99
3848
MILLENNIUM HUBER PLUS SAFETY INFUSION SET
K
99
3463
INTRAVASCULAR ADMINISTRATION SET
K
99
3187
SHELLY PROTECTED AV FISTULA NEEDLE
K
99
2999
DAISY PROTECTED SCALP VEIN SET
K
99
3147
DECAP
K
99
2266
IV ADMINISTRATION SET
K
99
2145
ECOMED SCALP VEIN SET
K
99
2268
NAC PRN NEEDLELESS ACCESS CONNECTOR
K
99
2072
BOLUS ACCESSORY SET
K
99
1979
SOF-SET MICRO QR INFUSION SET, MODELS 320 AND 321
K
99
1112
SAGE CONTRAST MANAGEMENT SYSTEM
K
99
0777
MED-RX EXTENSION SETS
K
99
2104
PARSET, MODEL A10001E
K
99
1985
COOK HIGH VOLUME INFUSION ADAPTER INTRAVASCULAR ADMINISTRATION SET
K
99
1932
INTRAVASCULAR ADMINISTRATION SET
K
98
4569
AB2 MED-FLO SOLUTION SET
K
98
4060
LUER ACCESS INJECTION SITE
K
99
0496
ANESFLOW-DUAL DRIP IV INFUSION SET
K
99
1759
MAERSK MEDICAL CONTOUR INFUSION SET
K
99
1653
INVISION-PLUS INJECTION PORT CONNECTOR SYSTEM
K
99
1513
HOMEPUMP C-SERIES AND HOMEPUMP C-SERIES ONE-STEP KVO
K
99
1599
CADD ADMINISTRATION SET
K
99
1301
CADD-PRIZM HIGH VOLUME ADMINISTRATION SET WITH 1.2 U FILTER AND ADD-ON ANTI-SIPHON VALVE, CADD ADMINISTRATION SET WITH 1
K
99
1255
CADD-TPN ADMINISTRATION SET, MODEL 21-7071
K
99
0693
FLEXNEEDLE PLUS
K
99
0388
TUTOPLUS IV ADMINISTRATION SET
K
98
2098
TUTODROP 1 AND TUTODROP 2
K
99
0288
FREE FLOW SAFETY DEVICE, MODEL MG 245052
K
98
4441
KVO CHECK VALVE ACCESSORY, MODEL EV-0001
K
98
4381
BURETROL SOLUTION SETS
K
99
0083
CADD ADMINISTRATION SET, CADD 250ML FLEXIBLE MEDICATION RESERVOIR, MODIFIED SECURIT SHELL, SECURITY SHELL ADAPTER
K
98
4638
PARAGON BOLUS ACCESSORY SET
K
98
4146
PARAGON INFUSION
K
98
4063
PARAGON BASAL/BOLUS ADMINISTRATION SET
K
98
3411
COLORVEES IV SET 20 DROPS/ML 105, 60 DROPS/ML 105, VENTED 20 DROPS 105, VENTED 60 DROPS 105
K
98
4561
SUBCUTANEOUS INFUSION SETS, MSR MODEL A & B
K
98
3926
MPS GRAVITY FLOW CONTROL SET
K
98
3217
ROWE DUAL-CHECK VALVE
K
98
3073
I.V. EXTENSION SET OR I.V. ADMINISTRATION SET
K
98
2672
COLLEAGUE PUMP SYRINGE ADAPTER SET
K
98
2587
MPS FIXED FLOW RATE SET
K
98
1792
SOLUTION ADMINISTRATION SET
K
98
1683
HUBER NEEDLE INFUSION SET MODEL #20G01 & Y-SITE MODEL #20G01Y
K
98
2123
CONTRAST CONTROL DEVICE
K
98
2047
MPS HUBER NEEDLE EXTENSION SET
K
98
1386
MANAN BLUNT NEEDLE
K
98
1548
NFC NEEDLEFREE CONNECTOR MODEL 69900
K
98
1547
NFC NEEDLEFREE Y-SITE, MODEL 69970
K
98
1157
STABLE FLOW
K
98
0994
IV ADMINISTRATION SETS WITH NEEDLE ACCESS DEVICES
K
98
0992
IV ADMINISTRATION SETS WITH NEEDLELESS ACCESS DEVICES
K
97
4571
SOLUTION ADMINISTRATION SET WITH CAPPED LUER ACTIVATED VALVE
K
98
0583
EXTENSION SET WITH 0.2U FILTER AND ANTI-SIPHON VALVE CADD ADMINISTRATION SET WITH 0.2U FILTER AND ANTI-SIPHON VALVE
K
98
1318
DUAL LUER LOCK CAP
K
98
0127
6 INCH MINI-BONE EXTENSION SET WITH LUER LOCK, NES01S, 6 INCH MIN-BONE EXTENSION SET WITH LUER SLIP, NES02S, 6 INCH STAT
K
97
3916
NP MEDICAL CAPLESS LUER ACTIVATED VALVE
K
97
4163
MINIMED SOF-SET ULTIMATE QR INFUSION SET MODELS 315 AND 316
K
97
1844
MCKINLEY OUTBOUND-2 SYSTEM
K
97
4589
SMARTVALVE
K
97
4145
V3 VALVE
K
97
4013
EXTENSION SET WITH MICROBORE TUBING, EXTENSION SET WITH MICROBORE TUBING AND 0.2 U FILTER, EXTENSION SET WITH MICROBORE
K
97
2854
PROTOS I.V. ADMINISTRATION SET (15 DROPS/ML) I4070S/(60 DROPS/ML)I4670S PRELIMINARY
K
97
2839
PROTOS 100ML BURETTE INFUSION SET/ PROTOS 150ML BURETTE INFUSION SET
K
96
3659
EXEL I.V. ADMINISTRATION SET
K
97
3167
POSITIVE PRESSURE CONNECTOR
K
97
3107
AMSINO I.V. ADMINISTRATION SET
K
97
1004
MEDCORP FLOW I.V. REGULATOR EXTENSION SET
K
97
2712
CORE RESISTANT HUBER INFUSION SETS
K
97
2957
SA-EF MULTI-LUMEN EXTENSION SET
K
97
2527
PHASEAL, SYSTEM FOR SEALED HANDLING OF CHEMOTHERAPEUTIC AGENTS
K
97
2493
NIPRO DISPOSABLE SOLUTION INFUSION SET
K
97
1624
DYE STOP AND SAVE - QUICKFILL
K
97
2663
SMART SET
K
97
2135
MAERSK MEDICAL PURELINE COMFORT SUBCUTANEOUS INFUSION SET
K
97
1500
ACCESS SYSTEMS NEEDLELESS VIAL ADAPTER
K
96
4439
NEEDLE-FREE VALVED CONNECTOR AND CAP
K
97
1293
LIFESHIELD PRIMARY I.V. SET WITH BACKCHECK VALVE
K
97
0855
CLAVE CONNECTOR
K
96
5027
VENTED I.V. SET
K
97
1701
CONTINU-FLO SOLUTION SET
K
96
4067
GORE IRRIGATION SET
K
97
1066
TAMARYN I.V. FLOW REGULATOR EXTENSION SET
K
97
0909
SAFE-CONNECT I.V. SET
K
97
1266
SAFE-CONNECT Y-SITE ADAPTER CATALOG NO. 681518
K
97
0524
SAFE-CONNECT I.V. EXTENSION SET
K
97
0485
SMARTSITE ACCESS PIN
K
97
0255
KIPP MED I.V. MANIFOLD
K
96
4918
NIMA NEEDLELESS INJECTIONSITE MASTER ADAPTER WITH POSIFLOW POSITIVE DISPLACEMENT FEATURE, AND I.V. SETS
K
97
0259
E-Z SET INFUSION SET/SAF-T E-Z SET INFUSION SET
K
97
0800
MAXCESS NEEDLEFREE - Y- SITE (100713)
K
97
0438
INTERLINK MICRO-INFUSION MANIFOLD EXTENSION SETS
K
97
0076
NIPRO DISPOSABLE SOLUTION INFUSION SET
K
96
4844
CONMED: STAT 2 AND STAT 2 PUMPETTE EXTENSION SETS AND MASTERFLOW AND MASTERFLOW PUMPETTE PRIMARY SETS
K
96
4876
SA.EF(TM) INFUSION PORT II - CONNECTOR AND EXTENSION SET
K
96
4968
MR EXTENSION SET (001)
K
96
4850
SOLUTION ADMINISTRATION SET WITH 0.22 MICRON HIGH PRESSURE EXTENDED LIFE FILTER
K
96
3981
VYGON BIONECTOR WITH EXTENSION SET
K
96
4812
NIMA NEEDLELESS INJECTIONSITE MASTER ADAPTER AND I.V. SET
K
96
4456
POLYFIN QR WITH WINGS INFUSION SETS, MODELS 365, 366, AND 367
K
96
4455
POLYFIN WITH WINGS INFUSION SETS, MODELS 306, 307, 333
K
96
4384
MODEL D-290P ADMINISTRATION SET
K
96
0771
SLAV AND SLAV-ONE INJECTION PORT CONNECTOR SYSTEM
K
95
5775
SAFECONNECT VALVE (CATALOG NO. XXXX)
K
96
3112
MMG MULTI LUMON EXTENSION SET
K
96
0431
PRESSURE STOPCOCK/MANIFOLD
K
96
3009
DELTEC SUBCUTANEOUS INFUSION SET
K
96
2893
INTERLINK ADAPTER FOR CONVENTIONAL Y-SITE
K
96
1049
FLEX NEEDLE
K
96
1928
BIOMEDIX I.V. EXTENSION LINE W/ STOPCOCK MODEL B50-102/B51-102
K
96
3070
VENIPUNCTURE KIT
K
96
2802
SAFE MATE I.V. FLUID DELIVERY SETS
K
96
2801
SAFE MATE I.V. EXTENSION SETS
K
96
1794
FLUID ADMINISTRATION SET - CONTRAST MANAGER
K
95
5821
I.V. ADMINISTRATION SETS
K
96
0391
STRATO/INFUSAID PERIPORT INFUSION SET 41770,41771
K
96
1495
HUBER NEEDLE EXTENSION SET WITH STANDARD Y-INJECTION SITE, INTERLINK Y-INJECTION SITE, INTERLINK T-INJECTION SITE
K
96
1225
CONTINUFLO SOLUTION SET/SECONDARY MEDICATION SET
K
95
4283
ENERGIZED CONTAINER SYSTEM (MODIFICATION)
K
96
1327
BEC NEEDLELESS INJECTION SITE
K
95
5585
V2 INJECTION SITE
K
96
1474
POLYFIN INFUSION SET MMT-106/MMT-107/MMT-133
K
95
5410
SNAPDOSE DEVICE
K
95
4883
FREE FLOW SAFETY DEVICE
K
96
0280
IVAC NEEDLE FREE VALVE ADMINISTRATION SETS
K
96
0661
MAXCESS NEEDLE FREE CONNECTOR (8200)
K
95
3825
ANGIOFLUSH II FLUID MANAGEMENT SYSTEM
K
95
4969
POLYFIN QR SUBCUTANEOUS INFUSION SET
K
95
5732
VENTED SOLUTION SET
K
95
5709
WINGED & SUBCUTANEOUS INFUSION SETS
K
95
2852
NIMA (NEEDLELESS INJECTIONSITE MASTER ADAPTER) & I.V. SET
K
95
5783
VLV SA.EF INFUSION PORT EXTENSION SETS
K
95
4823
VENIPUNCTURE KIT
K
95
3746
ARROW HIGH FLOW FLUID ADMINSITRATION SET W/BLOOD FILTER & EXTENSION SET
K
95
4983
EXTENSION SET WITH CHECK VALVE
K
94
0832
I.V. ADMINISTRATION SET CONNECTING DEVICE
K
95
0970
INFUSION SET
K
95
4870
SIMS DELTEC ANTI-SIPHON VALVE
K
95
4841
MODEL D-285N ADMINISTRATION SET
K
95
4813
ICU EXTENSION KIT
K
95
4123
LOW PROFILE SAFSITE Y-SITE
K
95
3791
VLV SA EF INFUSION PORT
K
95
3343
NEEDLELESS INJECTION SITE
K
95
3584
LIFESHIELD LUER ACTIVATED VALVE MALE ADAPTER PLUG
K
95
1665
PP-SPF1 / PP-SPF2
K
95
3474
IV START KIT
K
95
3225
IVAC BALL VALCE ADMIN. SETS
K
93
3898
HUBER NEEDLE SETS
K
95
2160
INTRAVASCULAR (I-V) ADMININISTRATION SET (DVGENPERS FPA)
K
95
2976
PLASTIC BLUNT CANNULA
K
95
2242
TRANSFEER SPIKE II
K
95
2810
DOSI-FLOW, MODELS 20 & 30
K
95
3231
PPMI-(XXX) AND PPMO-(XXX)
K
95
0895
HARMAC EXTENSION INFUSION SET
K
95
0153
VENTED/NONVENTED GEMINI ADMINISTRATION SET WITH CHECK VALVE AND TWO SAFSITE(TM) VALVES
K
95
2760
FIXED FLOW RATE GRAVITY ADMINISTRATION SETS
K
95
2664
SOLUTION ADMINISTRATION SET
K
95
2392
MLI SET
K
95
2074
SOLUTION SET WITH 1.2 MICRON AIR ELIMINATING FILTER
K
95
0597
CORE-RESISTANT HUBER INFUSION SET WITH Y-SITE
K
95
1922
ADMINISTRATION SETS WITH BALL FLOAT
K
94
2988
FILTERED EXTENSION SETS
K
94
2271
LEVEL 1* INJECT NEEDLE-FREE INJECTION SITE
K
94
3591
VECTOR(TM) AMBULATORY DRUG DELIVERY SYSTEM
K
94
5298
SMARTFLOW I ADMINISTRATION SET
K
95
2053
E-Z SET, SAF-T E-Z SET, AND MINICATH INFUSION SETS
K
94
4692
C-SERIES HOMEPUMP
K
94
3770
LOW VOLUME MULTIPORT
K
94
3038
STATLOCK-IPIDURAL
K
94
4824
SUREWING
K
94
2931
STATLOCK SECUREMENT DEVICES
K
94
4293
SABRATEK SABSIL SETS
K
95
0304
DESERET (R) T-PORT (R) MULTI FLO(TM) AND DESERET (R)PRN ADAPTER
K
95
0303
DESERET(R) I.V. LOOP AND DESERET (R) J LOOP
K
95
0302
E-Z SET(R) AND MINICATH(R) INFUSION SETS
K
94
6082
BEECH PRO LOK FIXED
K
93
3848
PRESPO 7, SELF-SUFFICIENT DRIP DEVICE
K
94
2446
I.V. ROLLER GUARD CLAMP
K
94
4320
VENTED/NON-VENTED GEMINI ADMINISTRATION SET
K
94
5617
PHARMA-PLAST PURELINE(TM) BASIC(TM) AND PURELINE(TM) CONTACT(TM) SUBCUTANEOUS INFUSION SETS
K
94
3897
NU-SITE
K
94
2349
MICROBORE EXTENSION SET
K
94
0657
IV BAG PUMP
K
94
1190
CLAVE NEEDLE-LESS CONNECTOR OPEN EXTENSION SET
K
94
4619
I.V.I.D. FLUID ADMINISTRATION SET MARKER
K
93
5811
BOLUS DISPENSER
K
94
5070
VERSASAE PLASTIC CANNULA- 11 GAUGE
K
94
4208
IV ADMINISTRATION SET FPA
K
94
1244
SAFELINE SYSTEM TURN LOCK CANNULA
K
94
0319
R-GROUP INTERNATIONAL COILED LOW PRESSURE EXTENSION LINE
K
94
2046
PHARMACIA DELTEC EXTENSION SET WITH ANTI-SIPHON VALVE
K
94
0697
BECTON DICKINSON INTERLINK(TM) LEVER/Y LOCK
K
94
1453
CHECK VALVE SOLUTION SET
K
92
4010
REDINOV PERFUSION SET
K
93
4095
IVAC VENTED SYRINGE ADAPTER ADMINISTRATION SETS
K
93
4513
PROVIDER PUMP SET W/INFUSION CARTRIDGE
K
94
2181
SOF-SET QR INFUSION SETS, MODELS MMT-115 AND MMT-116
K
94
1445
EXTENSION SET WITH ANTI-SIPHON VALVE
K
94
0897
IVAC NEEDLELESS INFECTION VALVE ADMINISTRATION SET
K
93
4119
ENERGIZED DRUG CONTAINER SYSTEM
K
92
5733
ISOFLUX IXL FLOW REGULATOR
K
92
5732
ISOFLUX IXZ FLOW REGULATOR
K
92
5731
ISOFLUX IXP FLOW REGULATOR
K
94
0867
CONTROL-A-FLO(TM) REGULATOR
K
92
6448
I.V. ADMINISTRATION SET
K
94
0054
MEASURED VOLUME SOLUTION ADMINISTRATION SET
K
93
1173
PRIMARY ADMIN SET W/UNIV SP-MAN BELOW/ABV PUMP CH
K
93
2165
INTRAVASCULAR ADMINISTRATION SET
K
94
0056
WINGED INFUSION SET A-PORT VASCULAR ACCESS SYSTEM
K
94
0053
INFUSION ADMINISTRATION SET
K
93
3326
LIFECARE PLUMSET VENTED SECONDARY I.V. SET
K
94
0072
I.V. SET (20 DROPS/ML)
K
94
0073
EXTENSION TUBE, EXTENSION TUBE LENGTH 20, & 30
K
94
0689
WALL IV EXTENSION TUBE
K
93
1377
SAFELINE SYSTEM IV ADMINISTRATION SETS & COMPONENT
K
94
0296
SAFE CONNECTOR
K
93
3390
REMOTE RESERVOIR ADAPTER(TM) CASSETTE WITH BAG
K
93
2856
IRRIGATION ACCESS CAP
K
93
5601
0.22 MICRON FINAL FILTER WITH EXTENSION TUBE
K
93
0854
SOLUTION SET WITH .2 MICRON FILTER
K
93
1550
EZ ADMINISTRATION SET
K
93
2637
SUBCUTANEOUS INFUSION SET
K
93
1659
3 LEAD CONNECTOR
K
93
3852
PRO-LOK EXTENSION SET
K
93
3749
BEECH VERSA LOK
K
93
3732
BEECH PROLOK
K
93
1658
IN-LINE BURETTE SET
K
93
2638
HUBER NEEDLE INFUSION SET
K
93
2446
INJECTION SITE
K
93
1119
DURHAM; NON CORING WINGED ADMINISTRATION SET
K
93
0974
DURHAM; INJECTION SITE EXTENSION SET, LUER LOCK
K
93
0927
DURHAM;T ADAPTOR EXTENSIONSET W/INJECTION SITE
K
92
5418
ENERGIZED CONTAINER SYSTEM
K
91
2069
AVI MODEL 4225 VENTED PIGGYBACK IV ADMIN SET
K
93
0926
DURHAM; Y CHECK SET-LUER LOCK W/INJECTION SITE
K
92
2115
IVAC NEEDLELESS INJECTION VALVE
K
92
5645
SELEC-3
K
93
0750
DURHAM; ADM. SET-LUER LOCK W/.22 MICRON FILTER
K
93
0751
DURHAM; EXTENSION TUBE LUER LOCK W/INJECTION SITE
K
93
0406
DURHAM; MIN BORE LUER LOCK EXTENSION SET
K
93
0410
DURHAM; LUER LOCK EXTENSION SET
K
92
5362
SUB-Q-SET(R) SUBCUTANEOUS INFUSION SET
K
92
5927
MPC-1000 INJECTION CAP/PLUG
K
92
5930
MPC-150 MALE TO MALE LUER ADAPTER
K
92
6119
EXEL HUBER INFUSION SET ROTATING WING
K
92
5430
LO-PROFILE EXTENSIONSET W/ .22 MICRON FILTER
K
92
5058
BARD AMBU PUMP SPIK TUB SET PACRET PROVID PUMP SET
K
93
0855
REPLACEMENT CAP
K
92
5228
IVAC 59 SERIES UNIVERSAL SET W/ ANTI-FREE FLOW VAL
K
92
6184
DOUGLAS MEDICAL PRODUCTS, INC. VENTED SPIKE ADAPT
K
92
5219
IVION ADMIN SETS W/FLOW CLIPS
K
93
1813
NEEDLESAFE HANDGUARD
K
92
4721
BAXTER SOLUTION ADMINISTRATION SETS
K
92
1322
MORSE ANESTHESIA MANIFOLD
K
92
5126
INTERLINK(TM) INJECTION SITE
K
92
4718
SHROUDED NEEDLE DEVICES
K
92
3560
ACCU-DROP I.V. EXTENSION SET
K
92
2637
HORIZON PUMP Y-TYPE BLOOD SET
K
92
4207
AVI(TM) MODEL 232 STANDARD IV ADMINISTRATION SET
K
92
1899
INTERLINK SYSTEM - T-CONNECTOR EXTENSION SET
K
92
2469
PRO-LOK EXTENSION SET(S)
K
92
3882
IV-TUBE SECURE
K
92
1594
HAEMOTROL MODEL #HT-SB/6 BURETTE SET
K
92
1429
SOLUTION ADMINISTRATION SET
K
90
4663
AUTO SASH (TM)
K
91
3982
LIFESHIELD ANESTHESIA SET
K
92
2558
INTERLINK(TM) INJECTION SITE
K
92
0537
SUBCUTANEOUS INFUSION SET
K
92
1674
LIFEPORT INFUSION SET AND INFUSION SET W/ Y SITE
K
92
1576
STRATO LIFEPORT LARGE BORE INFUSION SET
K
91
5571
CLAVE CONNECTOR
K
92
1391
SOLUTION ADMINISTRATION SET
K
92
1860
MODIFICATION TO IV SPIKE
K
91
5678
MERIT ADMINISTRATION SET
K
92
1703
CONTINU-FLO(R) SOLUTION SET
K
91
5828
INJECTION SITE WITH LUER LOCK
K
91
5109
RAPID ADD SITE DOUBLE LUMEN I.V.EXTENSION SET
K
92
0694
8000 SERIES VOLUMETRIC PUMP NON-GRAVITY FLOW SET
K
91
5390
3 LEAD EXTENSION WITH 2 INTERLINK INJECTION SITES
K
91
4924
CHEMO PRIMING PIN(TM)
K
91
3337
INJECTION CAP
K
91
4113
ANGIOGRAPHIC FLUSH SYSTEM
K
91
4792
PN 62290 0.22 MICRON MICRO INFUS I.V. EXTEN SET
K
90
5208
MORSE ANESTHESIA
K
91
4026
ANGIODYNAMICS ANGIOFILL FLUID MANAGEMENT SYSTEM
K
91
2856
MEDE-FLO I.V. EXTENSION SET
K
91
4048
NEEDLE*LOCK(TM) WITH INTERLINK(TM) INJECTION SITE
K
91
3333
I.V. PRIMING SET
K
91
4074
8000 SERIES VOLUMETRIC PUMP SOLUTION SET
K
91
3076
I.V. INSTANT TIMER
K
91
2861
FLU ADMIN/WASTE DISP SYS/PROTEC STA/ADMIN/FLUSH-N-
K
91
3627
3 PORT ADAPTER
K
91
3311
SAFETY INJECTION PORT, MODIFICATION
K
91
2141
VOLUMETRIC PUMP SOLUTION SET MODIFIED CASSETTE
K
91
1128
MEDIZIV INFUSION SET
K
91
0159
WINGED ADMININ. SET W/NON-CORING NEEDLE
K
91
2860
INTRAVASCULAR ADMINISTRATION SETS
K
91
1815
3RD HAND HELPER
K
91
1443
INSUL-LINE
K
91
1868
INTERLINK(TM) BLUNT CANNULA, MODIFICATION
K
91
1753
INTERVASCULAR ADMINSTRATION SET
K
91
1931
LUER LOCK INJECTION CAP
K
91
1136
B-D SAFETY-LOK(TM) I.V. NEEDLES
K
90
5218
4 LOW VOLUME IV EXTENSION SET WITH SLIDE CLAMP
K
90
5219
4' LOW VOLUME IV EXTENSION SET
K
90
5374
IV EXTENSION SETS WITH .22 MICRON FILTER
K
91
0142
SPARK KIT(R), MODIFICATION
K
91
0546
PIGGY LOCK NEEDLE HOUSING
K
91
0695
AUTO SASH (TM)
K
90
4886
VASCULAR ACCESS PORT CONTINUOUS INFUSION SETS
K
90
2858
AVI MODEL 4206 MANIFOLD CHECKVALVE IV ADMIN. SET
K
90
4685
EXEL HUBER INFUSION SET WITHOUT INJECTION SITE (Y)
K
90
2810
STERILE I.V. START KIT
K
90
2109
STATLOCK IV CONNECTOR AND ANCHOR SET
K
90
1088
LOW VOLUME BIFURCATED IV EXTENSION SET
K
90
1089
LOW VOLUME TRIFURCATED IV EXTENSION SET
K
90
0336
V SET
K
90
4217
PRO-LOK (TM) EXTENSION SETS
K
90
3809
PROTECTED NEEDLE WITH OR WITHOUT IV SET
K
90
4013
SPIVE NEEDLE SYSTEM, MODIFICATION
K
90
2330
E-Z FLO + SET
K
90
3541
SAFETY INJECTION PORT
K
90
1949
IV SET
K
89
6893
KAWASUMI I.V. ADMINISTRATION SET WITH BURETTE
K
89
6892
KAWASUMI Y-TYPE BLOOD ADMINISTRATION SET
K
89
6896
KAWASUMI SMALL VEIN INFUSION SET
K
89
6895
KAWASUMI I.V. ADMINISTRATION SET
K
89
6894
KAWASUMI BLOOD ADMINISTRATION SET
K
90
2166
WINGED INFUSION SET
K
89
5770
EXEL HUBER INFUSION SET
K
90
1151
I.V. ADMINISTRATION SET CONNECTING DEVICE
K
90
2196
MODIFIED STICK-GARD SAFETY NEEDLE
K
90
0353
SHIELDED PIGGYBACK IV NEEDLE
K
90
1729
SAF-T CLIK I.V. IN-LINE CONNECTOR & EXTENSION SET
K
90
1081
PRO-LOCK(TM) SHIELDING NEEDLE CONNECTOR ASSEMBLY
K
90
1046
VERSA-LOCK(TM) UNIVERSAL NEEDLE CONNECTOR
K
90
0909
IN-LINE VIAL CONNECTION SITE
K
90
0651
TS-1800 MEDICATION TRANSFER SPIKE
K
90
0188
ADVANCE ADMINISTRATION SETS (VARYING LENGTH)
K
90
0187
ADVANCE CONTRAST MEDIA SETS (VARYING LENGTH)
K
90
0644
I.V. FREEDOM CLIP
K
90
0427
IV TRIFURCATED EXTENSION SET
K
90
0426
IV BIFURCATED EXTENSION SET
K
89
7065
PORT INFUSION SET (PIS) INFUSION SET (IS)
K
89
6561
EXTENSION SET
K
89
6346
GRIPPER PORT-A-CATH NEEDLE WITH STOPCOCK
K
89
6161
AVI MODEL 2012, 1.2 MICRON FILTER IV ADMINISTRA.
K
89
5290
CHEMO-SPIKE RECONSTITUTION DEVICE
K
89
5291
IV DISPESNSING SPIKE
K
89
3646
VOLUMETRIC PUMP SOLUTION SET W/INTEGRAL AIRWAY
K
89
6291
INJECTION PORT II --- FOR INTERMITTENT INJECTION
K
89
5480
BLUNT NEEDLE PORT/I.V. PORT
K
89
5046
REMOTE RESERVOIR ADAPTER CASSETTE W/BAG SPIKE
K
89
5481
SHAMROCK SAFETY WINGED INFUSION SET
K
89
5367
INTRAVENOUS EXTENSION SET
K
89
5109
SECONDARY IV SET WITH PROTECTED NEEDLE
K
89
1193
MEDI-TRACE ACCU-NATE DEVICE
K
89
3716
VOLUMETRIC PUMP SOLUTION SET FOR FLO-GARD 8000
K
89
4787
MEL-PAK GENERAL DRUG DELIVERY SYSTEM KIT
K
89
4842
IMED GEMINI 12 NONVENTED Y-TYPE BLOOD/SOLUTION ADM
K
89
3909
MODIFIED MATERIAL USED IN INFUSION T
K
89
3120
KIT, INTRAVENOUS EXTENSION TUBING
K
89
2429
INJECTION PORT FOR---INTERMITTENT INJECTION
K
89
2440
KENDALL CURITY EXTENSION TUBES
K
89
2438
KENDALL CURITY INTRAVASCULAR CUT DOWN TUBES
K
89
1164
SAMUELS - MICRO -SCLER CATHETER
K
89
1146
TERUMO SURFLO(R) INJECTION PLUG
K
89
1063
SURFLO(R) WINGED INFUSION SET
K
89
0489
EXTENSION SET W/FLOW REGULATOR
K
89
1226
VASCULAR ACCESS PORT CONTINUOUS INFUSION SET
K
89
1176
INJECTION SITE PLUG (INTRAVASCULAR ADMINISTRATION)
K
88
5031
LOW ADSORPTION ADMINISTRATION SET
K
89
0679
SCALP VEIN SET
K
89
0176
EXTENSION SETS WITH AND WITHOUT FILTERS
K
89
1072
INTRAVASCULAR ADMINISTRATION SET
K
88
4511
SAFE MULTIPORT INJECTOR
K
89
0340
INTRAVASCULAR ADMINISTRATION SET
K
88
4657
LILY I.V. SET
K
88
4141
MONOPLACE HYPERBARIC EXTENSION SET (L 11055)
K
88
3986
CRIS ADAPTER
K
88
5264
WINGED INFUSION SET
K
88
4102
MODIFIED 7 INCH CONTINUOUS INFUSION SETS
K
88
5030
STANDARD ADMINISTRATION SETS
K
88
3764
INTRAVASCULAR ADMINISTRATION SET
K
88
4264
HIGH RISK NEEDLE CONNECTOR ASSEMBLY
K
88
4053
PRN PLUS + INFUSION SET
K
88
3318
VALLEYLAB I.V. ADMINISTRATION SETS
K
88
3612
LECTROSPIRAL
K
88
3638
SAFESITE INJECTION SITE AND BLUNT CANNULA
K
88
2347
HARMAC EXTENSION INFUSION SET
K
88
2503
30 IV EXTENSION SET W/TWO MALE LUER LOCKS
K
88
1975
SET, INTRAVASCULAR
K
88
2798
MULTIFLO ADAPTER
K
88
2797
LUER-LOK MULTIFLO ADAPTER
K
88
2302
IVAC(R) UNVENTED VOL. INFUSION SET MODEL 52080
K
88
2007
EXTENDED LIFE INJECTION SITE
K
88
1321
BLOOD/SOLUTION SET W/PRESSURE PUMP
K
88
1234
VENOVALVE(TM)
K
88
1052
CHECK VALVE
K
88
1390
NEEDLE SHIELD NEEDLE DISPOSAL UNIT
K
88
0928
MARQUETTE MEDICAL, INC. IV EXTENSION SETS
K
87
4725
SITE SOLUTION ADMINISTRATION SET
K
88
0482
SECONDARY SOLUTION ADMINISTRATION SET W/SHEATH
K
87
4307
MODEL DMC-75 MINI-CATHETER SET
K
87
4581
IVAC(R) DUAL RATE ADAPTER - MODEL 70090
K
87
4133
MX710 SERIES VASCULAR ACCESS INFUSION SET
K
87
4467
SET, ADMINISTRATION INTRAVASCULAR
K
87
2953
DISPOSABLE I.V. ADMINISTRATION SET
K
87
4403
A SERIES OF 7 INCH CONTINUOUS INFUSION SETS
K
87
3729
RATE-MATE NITROGLYCERIN I.V. ADMINISTRATION SET
K
87
3894
CONTINU-FLO SOLUTION W/CHECK VALVE 2 Y-INJECT SITE
K
87
3885
PHARMACIA DELTEC SUBCUTANEOUS INFUSION SET
K
87
3876
PHARMACIA DELTEC BAG SPIKE SET
K
87
3042
MODEL 1330 EXTENSION SET
K
87
1995
MICROS(TM)
K
87
2945
LOOK FLUID DISTRIBUTION SET
K
87
2124
CHURCHILL ALBUMIN IV ADMINISTRATION SET
K
87
2123
CHURCHILL TPN ADMINISTRATION SET
K
87
2795
CHANGE IN STERILITY TEST METHOD & TEST LAB. SITE
K
87
0995
SCALP VEIN SET
K
87
1843
TWO FLUID W/CHECK VALVE
K
87
0866
THE GRIPPER(TM) PORT-A-CATH NEEDLES
K
87
1841
THREE FLUID I.V. SETS
K
87
1842
TWO FLUID I.V. SETS
K
87
1732
CHURCHILL-H VENTED IV SET W/METERING CHAMBERS
K
87
1086
IV PUMP SET
K
87
1753
MASTER MEDICAL DEVICE IS I.V. STAT 2
K
87
0581
LIFEPORT(R) 7 INCH CONTINUOUS INFUSION SET
K
87
0582
LIFEPORT(R) 7 INCH CONTINUOUS INFUSION W/Y-SITE
K
87
0940
SOLUTION ADMINI. SETS- ALTER. DRIP CHAMBER/CONNEC.
K
87
0913
INJECTION SITE #014456-120
K
86
4296
S.C.T. MULTI PORT, INJECTION SITE
K
87
0188
NORFOLK MEDICAL BUTTERFLY INFUSION SET
K
86
4453
EMERGENCY & MILITARY INFUSION SYSTEM
K
86
4405
MANAN CONTRAST MEDIA ADMINISTRATION SET
K
86
4164
CRIS ADAPTED WITH VOLUME LIMITING BAG
K
86
3304
PRESELECTED FLOW RATE I.V. SET
K
86
4338
SECONDARY SET LOCK
K
86
3814
BAG SPIKE EXTENSION SET
K
86
2289
KOREAN GREEN CROSS SCALP VEIN SET
K
86
2491
EXEL BUTTERFLY SCALP VEIN SET
K
86
0952
I.V. SET WITH AND WITHOUT AIR VENT
K
86
2653
LUER LOCK ADAPTER/NUT
K
86
1182
TIMELINE VENIPUNCTURE SYSTEM
K
86
0609
TIMELINE VENIPUNCTURE SYSTEM
K
86
1275
HIGH FLOW I.V. SET
K
86
0616
VOLUME CONTROL SET WITH EXTENSION
K
86
1521
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0330)
K
86
1518
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0205F)
K
86
1519
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0330F)
K
86
1520
UNIVERSAL DISPOSABLE INFUSION SET (CODE 0205)
K
86
1250
MESULIN, INSULIN INFUSION SET
K
86
1430
CHURCHILL INJECTION SITE
K
86
1439
CHURCHILL FEMALE LUER LOCK CAP
K
86
0157
NITROGLYCERIN INTRAVASCULAR ADMINISTRATION SET
K
86
0322
CLINISET INFUSION SET
K
85
2616
MIRAGE INTRAVENOUS INFUSION SET OLOVSON-STERILE
K
86
0541
SOLUTION ADMINISTRATION SET
K
86
0605
FILTER SET 1) 1.2 MIC FILTER 2) 3.0 MIC FILTER
K
85
4365
IV SETS WITH NO PHTHALATE PLASTICIZER COMPONENTS
K
86
0272
SOLUTION ADMINISTRATION SETS
K
85
4806
RAPID SOLUTION ADMIN SET W/INTEGRAL HEAT EXCHANGER
K
85
4965
IN LINE VALVE CATALOG NO. 2000A
K
86
0242
JMS INFUSION SET
K
85
4804
MULTIPLE I.V. SETS
K
86
0201
PARENTERAL ADMINISTRATION SET
K
85
4754
PATIENTMATE TM
K
85
4658
CHURCHILL - HBC VENTED BALL CHECK IV SET
K
85
4574
IVAC CONTROLLED RELEASE INFUSION SYSTEM
K
85
4628
CHURCHILL-HCM VENTED IV SET
K
85
4446
TERUMO TERUFUSION BLOOD & Y-TYPE ADMIN. SET
K
85
4636
CHURCHILL-HE VENTED IV SET
K
85
4630
CHURCHILL-HS SUSPENDED NON-VENTED IV SET
K
85
4627
CHURCHILL-HS SUSPENDED VENTED IV SET
K
85
4436
CHURCHILL-H SCALP VEIN SET
K
85
4437
CHURCHILL-H VENTED IV SET
K
85
4435
CHURCHILL-H NON-VENTED IV SET
K
85
4346
MEDIFLEX DISPOSABLE TUBING CLAMP
K
85
2254
I.V. STAT MASTER
K
85
3019
NITROGLYCERIN INFUSION SET
K
85
3287
HUBOUT
K
85
3527
JUFREY CORP. UNIV. DISPOS. SCALP VEIN INFUSION SET
K
85
2606
FLEBOSET 1401(60 DROPS/MI) AND FLEBOSET1400(20)
K
85
3204
CHURCHILL VENTED IV SET
K
85
3385
I.A.S.S., IV SET W/AIR VENT & I.A.P.S. W/O AIRVENT
K
85
3255
OMNIMED I.V. SOLUTION ADMIN. SET
K
85
1516
CHERMEL SCALP VEIN SET
K
85
3387
ET - EXTENSION SETS
K
85
3327
JUFREY CORP. UNIVERSAL DISPOS. SCALP VEIN INFUSION
K
85
3086
SECONDARY ADMINISTRATION SET
K
85
2881
VENTED SECONDARY IV ADMINISTRATION SET
K
85
3184
PIGGYMATE I.V. TUBING LOCK
K
85
2989
WINGED INFUSION SETS
K
85
2361
INTRAVENOUS INJECTION SET
K
85
2488
CONTROLLED RELEASE INFUSION SYSTEM(CRIS)
K
85
2259
IVENT INTRAVENOUS ADMINSTRATION SET
K
85
2106
I.V. ADMINISTRATION SET
K
85
2140
NAMIC CONTRAST & FLUID DELIVERY SPIKES(VARIOUS)
K
85
1336
IV/0165 INFUSION SET
K
85
0769
VIGGO ACCESSORIES FOR I.V. THERAPY
K
85
1299
CORRECT FLO
K
85
0277
VIGGO I.V. ACCESSORIES-VIGGO EXTENSION TUBES ETC.
K
84
4843
IVAC DRUG ADMINISTRATION DEVICE
K
85
0506
CORRECT FLO INTRAVASCULAR ADMINISTRATION SET
K
85
0061
MICRO VOLUME DOUBLE LINE EXTENSION SET
K
85
0533
ATLANTIC OPTICAL SYSTEMS OPTIFILTER SYSTEM
K
85
0339
SPECIAL PROCEDURES PACK
K
85
0507
CRITIKON I.V. ADMINISTRAION SET
K
85
0112
OMNIMED IV SOLUTION ADMINISTRATION SET
K
84
4917
TURN NEEDLE INTRAVENOUS CANNUL, NUB, W/TUBING INTE
K
85
0088
ARTERIAL EXTENSION SET
K
84
4820
FLOW MED SK 140 BURET
K
84
4937
IVAC 52-99-0 UNVENTED & 52-99-1 VENTED VOL. INFUSI
K
84
3748
ANTI-ASPIRATION VALVE
K
84
4255
GENT-L-KARE STERILE I.V. START KIT
K
84
3090
UNIVERSITY OF CHICAGO VASCULAR ANGIOGRAM
K
84
3692
FLU VEN I.V. SET 0153-C PERMA-SET
K
84
3631
MINISET VEIN INFUSION SETS
K
84
2984
EXTENSION SET W/INJECTION SITE
K
84
2351
STERILE DESIGN-CUSTOM STERILE IV KIT
K
84
3463
PROVIDER BAG SPIKE W/12 MICROBORE EXTEN
K
84
2678
I.V. TRANSFER SPIKE
K
84
3185
IVAC C80014 Y SOLUTION ADMIN. SET
K
84
3054
DEKA SOLUTION ADMIN. SET DK 302-A
K
84
2858
FLUID ADMINISTRATION LINE W/SPIKE 14-923
K
84
3249
T-TYPE IV EXTENSION SET
K
84
2657
ACCESS. TO INTERAVACULAR ADMIN. SET
K
84
2088
FLU MET 2
K
84
2985
T- EXTENSION SET T-04-C
K
84
1717
INTRAVENOUS INJECTION SET
K
84
1562
HESUNG BLOOD TRANSFUSION SETS
K
84
2143
BENT WINGED MINI-VOL INFUSION SET
K
84
1564
HESUNG SCALP VEIN SET
K
84
1563
HESUNG'S SOLUTION INFUSION SETS
K
84
1772
HEPARIN CAP, INJECTION CAP MALE LUER-
K
84
1859
SECURA SET
K
84
1882
THREE WAY INFUSION SET
K
84
1361
SYRINGE ADDITIVE IV ADMIN. SETS
K
84
1186
INFUSION SET SCALP VEIN
K
84
1185
PLASTIC, STERILE TUBING CLOSED SET
K
84
1106
DELTA MULTIPLE NON RETURN CONNECTOR
K
84
0443
RETROGRADE INFUSION SET 3ML & 6ML-
K
84
1027
PROVIDER SITE PREP & CHECK STRIP KIT
K
84
1028
PROVIDER CAP SET
K
84
0760
HARVARD ANTI-REFLUX Y-SET
K
84
1025
TOP DISPOSABLE INFUSION SET
K
84
0878
QUIK LOK
K
84
0619
I.V. START KIT
K
84
0409
INFUSION SET-STERILE
K
84
0410
SOLUTION ADMIN. SET STERILE
K
84
0273
LOPEZ LOCK
K
84
0212
CONCENTRATED PLATELET ADMIN. SET
K
83
3398
MESULIN INSULIN INFUSION SET
K
83
4253
PBC IV SET NON-VENTED
K
83
4254
PBC IV SET VENTED
K
83
4252
PBC EXTENSION SET
K
84
0081
IV ADMINISTRATION SET
K
83
3939
NITROGLYCERIN I.V. ADMINISTRATION SET
K
83
4289
CONTINU-FLO SOLUTION ADMIN. 2C9102
K
83
4130
INTRAVENOUS FILTER SET
K
83
4071
LYMPHANGIOGRAPHY SET SPECIAL 30G
K
83
3949
MICRO INFUSION SET
K
83
2284
SOLUTION ADMIN. SET 2C9096 W/10 PVC
K
83
3740
VENOSET MULTI-MED PIGGYBACK W/IVEX-2
K
83
3741
VENOSET MULTI MED DUAL RATE PIGGYBACK
K
83
3178
SOLUTION ADMINISTRATION LINE W/SPIKE
K
83
3033
INFUSION SET-52-05-1 20 DROPS-MI VOL
K
83
3034
UNIVERSAL VENTED & NON/VOLUME INFUS-
K
83
3030
INTRAVASCULAR ADMINISTRATION SET
K
83
2542
I.V. ADMINISTRATION SET
K
83
2549
SOLUTION ADMIN. LINE W/SPIKE
K
83
2622
WINGED INFUSION SET
K
83
2434
HBO-1 PASS-THROUGH/EXTENSION TUBE
K
83
2105
ADMINISTRATIVE IV SET
K
83
2104
STERILE DISP. BUTTERFLY INFUSION SET
K
83
1445
INFUSION SETS #'S 124 & 142 PERSONAL
K
83
2329
STERILE IV SET 4 SIZES
K
83
2123
VENIPUNCTURE VALVE
K
83
1311
SOLUTION ADMIN. SETS W/FLASHBALL
K
83
0182
CUSTOM IV SET
K
83
0453
IV ADMINISTRATION SETS - MVP INFUSION
K
83
1087
MINI-VOL EXTENSION SET
K
83
1088
MINI-VOL I.V. SET
K
83
0755
I.V. SETS WALRUS BRAND VARIOUS CONFIGUR-
K
83
0891
SPECIALTY SET MODEL IV7A01
K
83
0868
COMBISET OR INFUSION SET
K
83
0194
IDAS INFUSION SET
K
83
0654
INFUSION PUMP RETROGRADE EXTEN. AS 715
K
83
0565
SECURA SET SECONDARY ADMIN. SET
K
83
0377
SECURA SET PRIMARY ADMIN. SET
K
82
3845
PORT-LOCK
K
83
0448
SECURA SET VOLUME LIMITING SET
K
83
0258
CENTAURSET 300 & 300 P.E.D
K
83
0152
MINILOOP I.V. CONNECTORS & ADAPTOR
K
83
0178
MINILOOP DISPOS. IV CONNECTORS ADAPT.
K
82
3214
DOSIMETRIC RELEASE PROGRAM - ADMIN. SET
K
82
3346
ACCUSET ADMINISTRATION SET
K
82
3347
MACRODOT ADD-I-MED ADMIN. SET
K
82
3027
ACCUDOT 380 SECONDARY I.V. SET
K
82
2775
INFUS. SETS-9120-50 CM & 9121-100 CM,EXT
K
82
2848
PRIMARY & SECONDARY I.V. TUBING SETS
K
82
2836
MICROFLEX-VENOFLUX
K
82
2408
BOSTON INFUSION SETS
K
82
2407
BOSTON SCALP VEIN INFUSION SETS
K
82
2406
BOSTON SOLUTION INFUSION SETS
K
82
2354
DISPOSABLE PLASTIC TRANSFUS./INFUS. ASSB
K
82
2027
I.V. ADMINISTRATION SET
K
82
1995
SOLUTION ADMINISTRATION SET (W/O NEEDLE)
K
82
1750
DESERET E-Z SET INFUSION SET
K
82
1377
AS 700 SERIES INFUSION PUMP ADMIN.
K
82
1764
DISPOSABLE INTRAVENOUS INJECTION SYSTEM
K
82
1624
LOW VOLUME INFUSTION SET
K
82
1578
VENOSET DUAL-RATE PIGGYBACK W/IVEX &
K
82
1515
VENTED NITROGLYCERIN I.V. SET
K
82
1032
MODEL SR-1020LF
K
82
0747
MONOJECT SAF-T-LOCK
K
82
0788
CLIRANS PRIMING SET
K
82
0133
MCGAW FAT EMULSION SET
K
82
0453
THE INT-STOPPER
K
82
0278
INTRAVASCULAR ADMINISTRATION SET
K
82
0203
FLUID ADMINISTRATIVE SET, AFI
K
81
3259
IN-STOPPER (INJECTION CAP
K
81
3092
ACCUPRO I.V. ADMINISTRATION SET
K
81
3194
AUTO-SYRINGE SUB-CUTEANEOUS SET
K
81
3083
VENOFIX SCALP VEIN SET
K
81
2657
INJECTION CAP, LUER LOCK
K
81
2688
QI 1150-1T INFUSION T
K
81
1885
30-30-2 700 SYRINGE EXTENSION SET
K
81
2231
INTRAVENOUS ADMINISTRATION SET
K
81
1914
FLU VEN I.V. SETS
K
81
1837
I.V. ADMINISTRATION SET
K
81
1078
RADIATION STERILIZED ADMIN. SET
K
81
1685
I.V. ADMINISTRATION SET
K
81
1561
LO-VOL I.V. SETS
K
81
1463
AUTO-SYRINGE MICRO VOLUME EXTENSION SET
K
81
1107
IV SETS
K
81
1110
MODELS: 52-01-0, 52-01-1
K
81
1006
SOLUTION ADMINISTRATION SET
K
81
0239
VENTED PRIMARY PIGGYBACK VENOSET DUAL
K
81
0317
NITROGLYCERINE IV SET
K
81
0921
MALE LUER LOCK PLUGS
K
81
0721
PROCESS CHANGE
K
80
2170
SURU BLOOD COLLECTION SET
K
80
2169
SURU INFUSION SET TYPE J
K
81
0365
HAEMONETICS 170 Y INFUSION SET
K
80
2329
DISPOSABLE CONSTRAST DELIVERY SPIKE KIT
K
80
1871
PRIMARY SOLUTION ADMIN. SET-#86-01-0 260
K
80
1874
MODEL 86-21-1 260 APPROX. 60 DROPS/VENTD
K
80
1873
MODEL 86-21-0 260 SECONDARY MEDICATION
K
80
1872
MODEL 86-01-1 260 SOLUTION ADMIN. SET
K
80
1821
FLOW MED 150
K
80
1613
MODEL 72-81-0 UNVENTED SOLUTION ADM. SET
K
80
1540
MCGRAW I.V. ADMINISTRATION SET
K
80
0878
SECONDARY I.V. TUBING SETS
K
80
1179
FLOW MED 160
K
80
0711
VOLUMETRIC PUMP CASSETTE W/ATTACHED SET
K
80
0637
PLASMA PRODUCTS CO., INTRA/ADMIN/SET-
K
80
0638
PLASMA PRODUCTS CO. NON-VENTED INTRA/SET
K
80
1004
FLOW MED 160
K
80
0600
B-D STASET, I.V. FLOW CONTROLLER
K
80
0403
MCGAW/EPIC I.V. ADMIN. SET
K
80
0358
Y-TYPE INFUSION SET (2 LEAD)
K
79
1496
LOW PLASTICIZER ADMINISTRATION SETS
K
80
0137
PRI. PIGGYBACK I.V. W/DUAL PIERCING PIN
K
79
2228
VENTED I.V. SET
K
79
2560
MASTER I.V. DIAL LOCK
K
79
2538
CONTINU-FLO ADMIN. SET CODE 2C/200
K
79
1930
IV EXTENSION SET SL
K
79
1672
ALBUMIN INTRAVENOUS ADMINISTRATION SET
K
79
1529
INFUSION NEEDLE SET
K
79
1173
SURFLO INJECTION PLUG
K
79
0901
I.V. TUBING ORGANIZER
K
79
0582
INTRAVASCULAR ADMINISTRATION SET
K
79
0604
CUSTOM TUBING SETS
K
79
0574
EPIC D215
K
79
0424
FLU-VEN 01510
K
79
0408
T-CONNECTOR
K
79
0077
BIOSTIL # 3884
K
79
0062
IV ADMINISTRATION SET WITH BACKCHECK
K
79
0108
FILTERSET 0.22, I.V. PUMP
K
78
2134
FILTER FOR HYPERALIMENTATION SET
K
78
1813
SOLUTION ADMINISTRATION, TIP PROTECTOR
K
78
1637
MODEL IV 1500 STANDARD BURETTE
K
78
1812
SOLUTION ADMINISTRATION, FLEX VALVE
K
78
1744
IV SET WITH GRADUATED CHAMBER
K
78
1785
I.V. SET WITH IN-LINE FILTER
K
78
1575
DISPOSABLE LYMPHANGIOGRAM SET
K
78
1184
INFUSION SET, VENOTHIN 19
K
78
1190
INFUSION SET, VENOTHIN 21
K
78
1188
INFUSION SET, VENOTHIN 25
K
78
1187
INFUSION SET W/ INJECTION SITE, 23D-W
K
78
1186
INFUSION, VENOTHIN 23
K
78
1185
INFUSION SET W/ INJECTION SITE
K
78
1189
FLU VEN 0151
K
78
1036
AUTO-SYRINGE INFUSION SET
K
78
0970
BURETTE SET WITH AIR CONTROL LEVER
K
78
0655
STERILE INFUSION SET TYPE S
K
78
0658
STERILE BLOOD ADMINISTRATION SET
K
78
0657
STERILE BLOOD COLLECTION SET
K
78
0656
STERILE INFUSION SET TYPE J
K
78
0559
DISPOSABLE INFUSION SET
K
78
0551
I.V. ADMINISTRATION SET WITH MINI-SPIKE
K
78
0481
I.V. LEVER CLAMP
K
78
0130
BURETTE INTRAVENOUS ADMIN. SETS.
K
77
1983
SCALP VEIN SET
K
77
2008
SCALP VEIN SETS
K
77
2036
IN-LINE BURETTE SET
K
77
1593
I.V. PUMP SET FOR FAT EMULSION
K
77
1270
BLOOD ADMINISTRATION TYPE R
K
77
1267
INFUSION SET TYPE S
K
77
1268
INFUSION SET TYPE J
K
77
1271
SCALP VEIN SET
K
77
1453
FLUID HANDLING DEVICE W/INPUT TUBING
K
77
1362
FLU VEN 0150
K
77
1339
MALE LUER LOCK PLUG
K
77
1204
SURFLO WINGED INFUSION SET
K
77
0743
SOLUSET FOR IV FAT EMULSION
K
77
0863
FLU VEN 0160
K
77
0763
BURETTE SET, 2C0132
K
77
0744
IV SET THAT REVERTS TO KVO RATE
K
77
0589
FILTER, INTRAVENOUS W/AUTO AIR VENT
K
77
0518
PIGGYBACK VENOSET W/0.22 FILTER
K
77
0171
ERIKA I.V. ADMINISTRATION SET
K
77
0051
VENOSET FOR I.V. FAT EMULSION
K
76
1327
IV SETS 2000 SERIES (HS-200,2L0,220)
K
76
0110
FILTER, I.V. (#4700)
K
76
0111
FILTER, I.V., WITH FLASH BULB (#4701)
K
76
0103
CAP, INJECTION (#4600)
FPB
Filter, Infusion Line
FPK
Tubing, Fluid Delivery
FPL
Incubator, Neonatal Transport
FQH
Lavage, Jet
FQJ
Support, Scrotal, Therapeutic
FQK
Binder, Perineal
FQL
Stocking, Medical Support (For General Medical Purposes)
FQM
Bandage, Elastic
FRF
Cleaner, Air, Medical Recirculating
FRL
Fiber, Medical, Absorbent
FRN
Pump, Infusion
FRP
Holder, Infant Position
FRR
Chamber, Reverse Isolation, Patient Care
FSA
Lift, Patient, Non-Ac-Powered
FSD
Binder, Abdominal
HEF
Binder, Breast
HFS
Shield, Nipple
IKY
Mattress, Flotation Therapy, Non-Powered
KMK
Device, Intravascular Catheter Securement
KMO
Binder, Elastic
KPE
Container, I.V.
KYP
Snake Bite Suction Kit
KYQ
Kit, Chemical Snake-Bite
KZD
Infusor, Pressure, For I.V. Bags
KZE
Injector, Fluid, Non-Electrically Powered
LBI
Unit, Neonatal Phototherapy
LDR
Controller, Infusion, Intravascular, Electronic
LGM
Chamber, Patient Isolation
LGN
Chamber, Patient Transport Isolation
LGZ
Warmer, Thermal, Infusion Fluid
LHF
Warmer, Microwave, Infusion Fluid
LHI
Set, I.V. Fluid Transfer
LJL
Detectors And Removers, Lice, (Including Combs)
LJS
Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
LJT
Port & Catheter, Implanted, Subcutaneous, Intravascular
LLI
Bed, Therapeutic, Ac-Powered, Adjustable Home-Use
LLK
Legging, Compression, Non-Inflatable
LZH
Pump, Infusion, Enteral
MDR
Binder, Medical, Therapeutic
MEA
Pump, Infusion, Pca
MEB
Pump, Infusion, Elastomeric
MEG
Syringe, Antistick
MHC
Needle, Interosseous
MHD
Pump, Infusion, Gallstone Dissolution
MJF
Check Valve, Retrograde Flow (In-Line)
MMK
Container, Sharps
MQX
Needle, Acupuncture, Single Use
MRZ
Accessories, Pump, Infusion
MZR
Topical Approximation System
NEP
System/Device, Pharmacy Compounding
NGT
Saline, Vascular Access Flush
NKK
Needle, Hypodermic, Single Lumen, Reprocessed
NKN
Syringe, Piston, Reprocessed
NRW
Stimulator, Intramuscular, Automatic
NSC
Injector, Pen
NTC
Nursing Pad, Hydrogel
NTX
Nursing Pad, Polyurethane Pad With Starch Copolymer, Glycerin, And Surfactant (F-68)
NXH
Nursing Pad, Cohesive Gel
NZG
Bassinet, Hospital
NZW
Heparin, Vascular Access Flush
NZX
Water, Vascular Access Flush
OBK
Port, Protector/Cushion
ODI
Administration Set Docking Station
ODY
Tunneled Catheter Remover
OJA
Intravenous Extension Tubing Set
OKC
Implanted Subcutaneous Securement Catheter
OKE
Port Introducer Kit
OKL
Intravascular Administration Set, Automated Air Removal System
OMF
Percutaneous, Implanted, Long-Term Intravascular Catheter Accessory For Catheter Position
ONB
Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System
ONM
Radiant Infant Warmer Cabinet
PUK
Administration Set Securement Device
OPP
Pump, Infusion, Insulin Bolus
OSI
Bariatric Bed
OUW
Infant Positioner, Rx, Use In Highly Monitored Setting
OWL
Peripheral Catheter Insertion Kit
PDH
Blanket, Neonatal Phototherapy
PEF
Heparin Flush In 0.45% Sodium Chloride
PEZ
Central Venous Catheter Dressing Change Kit
PHC
Infusion Safety Management Software
PKP
Immunoglobulin G (Igg) Infusion System
PMS
Peripheral Intravenous (Piv) Infiltration Monitor
PND
Midline Catheter
POQ
Blood Transfusion Kit
POR
Parenteral Administration Kit
PQH
Iodinated Contrast Media Transfer Tubing Set
PQX
Epinephrine Syringe
PRN
Pediatric Position Holder
PTD
Subcutaneous Implanted Apheresis Port
PTI
Non-Coring (Huber) Needle
PUN
Lice Removal Kit Containing A Solution
PUR
Vacuum Syringe
PVZ
Non-Stainless Steel Needle
PWH
Administrations Sets With Neuraxial Connectors
PWN
Baby Care Kit
PWO
Blood Administration Kit
PWQ
Buret Administration Intravenous Kit
PWR
Catheter Repair Kit
PWX
Insect Sting Emergency Kit
PWY
Lumbar Puncture Tray (Adult & Pediatric)
PXB
Percutaneous Introducer Kit
PXI
Thoracentesis Tray
PXJ
Umbilical Catheter Insertion Tray
PXK
Vascular Access Port Kit
PXL
Venipuncture Kit
PYR
Neuraxial Administration Set - Intrathecal Delivery
PZW
Catheter Access Cover, Tamper-Resistant
QBL
Piston Syringe Lever
QDM
Midazolam Syringe
QEH
Piston Syringe With Neuraxial Connector – Epidural, Peripheral, And/Or Indirect Cerebral Spinal Fluid Contact
QJY
Infusion Pump, Drug Specific, Pharmacy-Filled
QLF
On-Body Injector
QLY
Ophthalmic Syringe
QMT
Prep Kit – Vaccine Injection
QNQ
Low Dead Space Piston Syringe
QNS
Low Dead Space Needle, Single Lumen, Hypodermic
QOG
Injection Data Capture Device
QOI
Intravenous Catheter Force-Activated Separation Device.
QTI
Saline Vascular Access Flush With Integrated Alcohol Disinfectant Device
QYM
Ophthalmic Needle
SCL
Allergen And Vaccine Delivery Needles
SEF
Central Venous Catheter With Manual Insertion System
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
Subpart G—General Hospital and Personal Use Miscellaneous Devices
Subpart G—Miscellaneous Devices
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
HO
/
subpart-f—general-hospital-and-personal-use-therapeutic-devices
/
FPA
/
K935811
View Source
BOLUS DISPENSER
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K935811
510(k) Type
Traditional
Applicant
I-FLOW CORP.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
1/20/1995
Days to Decision
414 days
Submission Type
Summary