← Product Code [FNM](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/FNM) · K960188

# PRESSUREGUARD: SELECTCARE (K960188)

_Span-America Medical Systems, Inc. · FNM · Oct 2, 1996 · General Hospital · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/FNM/K960188

## Device Facts

- **Applicant:** Span-America Medical Systems, Inc.
- **Product Code:** [FNM](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/FNM.md)
- **Decision Date:** Oct 2, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.5550
- **Device Class:** Class 2
- **Review Panel:** General Hospital
- **Attributes:** Therapeutic

## Indications for Use

For the prevention and treatment of pressure ulcers.

## Device Story

Powered air flotation mattress; provides pressure-reducing support; adjustable firmness for patient comfort; includes CPR mode for firm surface during resuscitation. Used in clinical settings; operated by healthcare staff. Output is physical support surface; affects patient positioning and pressure distribution; benefits include pressure ulcer prevention and treatment.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Powered air flotation mattress system; adjustable firmness controls; integrated CPR mode for surface firming. No specific materials or software algorithms described.

## Regulatory Identification

An alternating pressure air flotation mattress is a device intended for medical purposes that consists of a mattress with multiple air cells that can be filled and emptied in an alternating pattern by an associated control unit to provide regular, frequent, and automatic changes in the distribution of body pressure. The device is used to prevent and treat decubitus ulcers (bed sores).

## Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 880.9.

## Predicate Devices

- PressureGuard IV ([K951112](/device/K951112.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

SPAN-AMERICA
MEDICAL SYSTEMS, INC.
K960188
OCT - 2 1996

# PRESSUREGUARD: SELECT CARE

## 510K SUMMARY

1.0. Submitter: Span-America Medical Systems, Inc.
Address: 70 Commerce Drive; Greenville, SC 29615
Telephone: (864) 288-8877
Contact Person: Charles B. Mitchell, President &amp; CEO
Wanda J. Totton, Director of Quality
Date Prepared: January 8, 1995

2.0. Trade Name: PressureGuard: SelectCare Mattress System
Common Name: Powered Air Flotation Mattress
Classification Name: Unknown

3.0. Predicate Device: PressureGuard IV, 510K951112

4.0. Description: The PressureGuard SelectCare is a powered air flotation mattress which provides pressure-reducing support within a range of adjustable firmness to meet individual comfort needs. The system also includes a CPR mode, providing a firm surface for performing CPR.

5.0. Indications for Use: For the prevention and treatment of pressure ulcers.

6.0. Substantial Equivalence: The product is similar in function and intended use to the PressureGuard IV, 510K951112 for the Center and CPR Modes.

P.O. Box 5231, Greenville, S.C. 29606 • 803-288-8877 • FAX 803-288-8692

---

**Source:** [https://fda.innolitics.com/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/FNM/K960188](https://fda.innolitics.com/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/FNM/K960188)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
