QPC · Gown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection
General, Plastic Surgery · 21 CFR 878.4040 · Class 2
Overview
| Product Code | QPC |
|---|---|
| Device Name | Gown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection |
| Regulation | 21 CFR 878.4040 |
| Device Class | Class 2 |
| Review Panel | General, Plastic Surgery |
Identification
Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded.
Classification Rationale
Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption: (i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.
Special Controls
*Classification.* (1) Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption:(i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.
Recent Cleared Devices (10 of 10)
| Record | Device Name | Applicant | Decision Date | Decision |
|---|---|---|---|---|
| K252940 | VR® Personal Protective Level 3 Gown (VR Gowns) | PolyConversions, Inc. | Dec 16, 2025 | SESE |
| K242689 | AAMI Level 4 Protective; Gown | Azac Group | Jan 13, 2025 | SESE |
| K233526 | Medline Open-back Level 3 Protective Gown | Medline Industries, LP | Mar 5, 2024 | SESE |
| K230384 | PolyWear® Personal Protective Level 3 Gown | PolyConversions, Inc. | Aug 11, 2023 | SESE |
| K222128 | Protective Gown AAMI Level 4 | Kenpax International Limited | Aug 8, 2023 | SESE |
| K212464 | Dukal Corporation AAMI Level 4 Open-Back Protective Gown | Dukal Corporation | Mar 30, 2022 | SESE |
| K203821 | Donagamex Blue Performance Protective Gown | Dong Nai Garment Corporation (Donagamex) | Dec 17, 2021 | SESE |
| K210405 | ProTEC-USA EZDoff Gown | Cadillac Products, Inc. | Dec 15, 2021 | SESE |
| K182830 | Cardinal HealthTM Poly-Coated Open-Back Protective Gown | Cardinal Health200, LLC | Apr 26, 2019 | SESE |
| K160337 | Safecare Open Back Protective Gowns and ValueCare Open Back Protective Gowns | Bam Corporation Limited | Jul 7, 2017 | SESE |
Top Applicants
- PolyConversions, Inc. — 2 clearances
- Azac Group — 1 clearance
- Bam Corporation Limited — 1 clearance
- Cadillac Products, Inc. — 1 clearance
- Cardinal Health200, LLC — 1 clearance