ULTRAFREE STERILE LATEX POWDER-FREE SURGICAL GLOVES
Device Facts
| Record ID | K964474 |
|---|---|
| Device Name | ULTRAFREE STERILE LATEX POWDER-FREE SURGICAL GLOVES |
| Applicant | Allegiance Healthcare Corp. |
| Product Code | KGO · General, Plastic Surgery |
| Decision Date | Mar 11, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4460 |
| Device Class | Class 1 |
Intended Use
Ultrafree Sterile Latex Powder-Free Surgical Gloves are intended for use in sterile environments within hospitals and other healthcare facilities. The gloves are appropriate for use during invasive surgical procedures and non-invasive medical procedures requiring sterility. They are intended to be worn by operating room personnel to protect a surgical wound from contamination.
Device Story
Sterile, powder-free surgical gloves; composed of natural rubber latex; intended for use by operating room personnel in hospitals/healthcare facilities; provides barrier protection for surgical wounds during invasive and non-invasive procedures; prevents contamination between patient and clinician.
Clinical Evidence
Bench testing only. Biocompatibility: primary skin irritation (negative), systemic toxicity (negative), intracutaneous reactivity (none), hemocompatibility (no lysis), guinea pig maximization (no irritation). Physical: tensile strength/elongation meet ASTM D3577-91; barrier defects meet 21 CFR §800.20 (AQL 2.5); powder-free status verified via vacuum filtration (<2 mg/glove) and negative iodine test.
Technological Characteristics
Material: natural rubber latex. Form factor: surgical glove. Performance standards: ASTM D3577-91 (tensile strength/elongation), 21 CFR §800.20 (barrier integrity). Designation: powder-free (vacuum filtration/iodine test). Sterilization: sterile.
Indications for Use
Indicated for use by operating room personnel during invasive and non-invasive medical procedures requiring a sterile barrier to protect surgical wounds from contamination.
Regulatory Classification
Identification
A non-powdered surgeon's glove is a device intended to be worn on the hands of operating room personnel to protect a surgical wound from contamination. A non-powdered surgeon's glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.
Predicate Devices
- Triflex® Sterile Latex Powder-Free Surgical Gloves
Related Devices
- K993562 — POWDER FREE LATEX STERILE SURGICAL GLOVES · Tg Medical Sdn. Bhd. · Dec 29, 1999
- K970795 — SHANG HO · Shang HO Industrial Corp. , Ltd. · Dec 18, 1997
- K992020 — BRIGHTWAY BRAND LATEX SURGICAL GLOVES - STERILE (POWDERED) · Brightsway Holdings Sdn Bhd · Jul 26, 1999
- K992219 — POWDERED LATEX STERILE SURGICAL GLOVES · Tg Medical Sdn. Bhd. · Jul 30, 1999
- K012135 — POWDER FREE BROWN LATEX SURGICAL GLOVES WITH PROTEIN CONTENT LABELING CLAIM (50 MICROGRAMS OR LESS) · Wrp Asia Pacific Sdn. Bhd. · Aug 1, 2001