ULTRAFREE STERILE LATEX POWDER-FREE SURGICAL GLOVES

K964474 · Allegiance Healthcare Corp. · KGO · Mar 11, 1997 · General, Plastic Surgery

Device Facts

Record IDK964474
Device NameULTRAFREE STERILE LATEX POWDER-FREE SURGICAL GLOVES
ApplicantAllegiance Healthcare Corp.
Product CodeKGO · General, Plastic Surgery
Decision DateMar 11, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4460
Device ClassClass 1

Intended Use

Ultrafree Sterile Latex Powder-Free Surgical Gloves are intended for use in sterile environments within hospitals and other healthcare facilities. The gloves are appropriate for use during invasive surgical procedures and non-invasive medical procedures requiring sterility. They are intended to be worn by operating room personnel to protect a surgical wound from contamination.

Device Story

Sterile, powder-free surgical gloves; composed of natural rubber latex; intended for use by operating room personnel in hospitals/healthcare facilities; provides barrier protection for surgical wounds during invasive and non-invasive procedures; prevents contamination between patient and clinician.

Clinical Evidence

Bench testing only. Biocompatibility: primary skin irritation (negative), systemic toxicity (negative), intracutaneous reactivity (none), hemocompatibility (no lysis), guinea pig maximization (no irritation). Physical: tensile strength/elongation meet ASTM D3577-91; barrier defects meet 21 CFR §800.20 (AQL 2.5); powder-free status verified via vacuum filtration (<2 mg/glove) and negative iodine test.

Technological Characteristics

Material: natural rubber latex. Form factor: surgical glove. Performance standards: ASTM D3577-91 (tensile strength/elongation), 21 CFR §800.20 (barrier integrity). Designation: powder-free (vacuum filtration/iodine test). Sterilization: sterile.

Indications for Use

Indicated for use by operating room personnel during invasive and non-invasive medical procedures requiring a sterile barrier to protect surgical wounds from contamination.

Regulatory Classification

Identification

A non-powdered surgeon's glove is a device intended to be worn on the hands of operating room personnel to protect a surgical wound from contamination. A non-powdered surgeon's glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} MAR 11 1997 K964474 # XIV. SUMMARY OF SAFETY AND EFFECTIVENESS ## Allegiance ### 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS ### ULTRAFREE STERILE LATEX POWDER-FREE SURGICAL GLOVES **Manufacturer:** Allegiance Healthcare Sdn. Bhd. Plot 87 Kampung Jawa 11900 Bayan Lepas Penang, West Malaysia **Regulatory Affairs Contact:** Maryalice Smith Allegiance Healthcare Corporation 1500 Waukegan Road, Bldg. K McGaw Park, IL 60085 **Telephone:** (847) 785-3322 **Date Summary Prepared:** February, 1997 **Product Trade Name:** Ultrafree Sterile Latex Powder-Free Surgical Gloves **Common Name:** Surgical Glove **Classification:** Glove, Surgical **Predicate Devices:** Triflex® Sterile Latex Powder-Free Surgical Gloves **Description:** The Ultrafree Surgical gloves are formulated using natural rubber latex and offered sterile. **Intended Use:** Ultrafree Sterile Latex Powder-Free Surgical Gloves are intended for use in sterile environments within hospitals and other healthcare facilities. The gloves are appropriate for use during invasive surgical procedures and non-invasive medical procedures requiring sterility. They are intended to be worn by operating room personnel to protect a surgical wound from contamination. 18 {1} Page 2 ## Substantial Equivalence: The Ultrafree Sterile Latex Powder-Free Surgical Gloves are substantially equivalent to Triflex® Sterile Latex Powder-Free Surgical Gloves in that they provide the following characteristics: - intended use - size, configuration, packaging - made of natural rubber latex - tensile strength and thickness profiles ## Summary of Testing: | Test | Result | | --- | --- | | Primary Skin Irritation | Glove does not display any potential for irritation. | | Systemic Toxicity | Glove does not elicit any toxic reactions to acute application. | | Intracutaneous Reactivity | No reactivity was observed. | | Hemocompatibility | Gloves are hemocompatible exhibiting no lysis. | | Guinea Pig Maximization | Glove does not display any potential for irritation. | | Ultimate Elongation & Tensile Strength | Glove meets or exceeds requirements for rubber surgical gloves per ASTM D3577-91. | | Barrier Defects | Glove meets or exceeds requirements per 21 CFR §800.20, AQL = 2.5. | | Data/Test Method | Glove meets powder level requirements for “Powder Free” designation using the vacuum filtration method plus a negative iodine test. Results generated values below the 2 mg/glove cornstarch level including negative iodine test. |
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...