← Product Code [FXX](/submissions/SU/subpart-e%E2%80%94surgical-devices/FXX) · K964114

# DEPUY OPTI-CON AND E-Z SHIELD SYSTEMS (K964114)

_Depuy, Inc. · FXX · May 6, 1997 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/HO/subpart-e%E2%80%94surgical-devices/FXX/K964114

## Device Facts

- **Applicant:** Depuy, Inc.
- **Product Code:** [FXX](/submissions/SU/subpart-e%E2%80%94surgical-devices/FXX.md)
- **Decision Date:** May 6, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4040
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery

## Intended Use

The DePuy Opti-Con and E-Z Shield Systems are intended as face shields to be worn by operating room personnel during surgical procedures to provide splash protection to protect the operating room personnel from the transfer of microorganisms, body fluids and particulate material. The Opti-Con Shields, E-Z Shield and Opti-Con goggles are intended to be disposable. The Opti-Con head gear is intended to be re-usable.

## Device Story

System provides splash protection for OR personnel eyes, nose, mouth, ears. Components: Opti-Con (disposable polycarbonate faceshields, reusable headgear); E-Z Shield (one-piece disposable PETG faceshield/headband); Opti-Con goggles (disposable polycarbonate). Used in surgical settings to prevent transfer of microorganisms, body fluids, and particulates. Protects wearer via physical barrier. No electronic or algorithmic components.

## Clinical Evidence

Bench testing only; impact resistance testing performed.

## Technological Characteristics

Materials: Polycarbonate (Opti-Con shields/goggles), PETG (E-Z Shield). Form factor: Faceshields (standard/long), goggles, headgear. Energy source: None. Connectivity: None. Sterilization: Sterile or non-sterile options.

## Regulatory Identification

Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded.

## Special Controls

*Classification.* (1) Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption:(i) The user contacting components of the device must be demonstrated to be biocompatible.
(ii) Analysis and nonclinical testing must:
(A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and
(B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device.
(iii) NIOSH approved under its regulation.
(2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

## Predicate Devices

- Splash Shield Splash Shields
- DePuy Disposable Filter/Hood
- DePuy Shades™ Protective Glasses

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

MAY - 6 1997

# 510(k) SUMMARY (K964114)

|  NAME OF FIRM: | DePuy Inc.
700 Orthopaedic Drive
Warsaw, Indiana 46581-0988  |
| --- | --- |
|  510(k) CONTACT: | Cheryl Hastings
Manager, Clinical Affairs  |
|  TRADE NAME: | DePuy Opti-Con and E-Z Shield Systems  |
|  COMMON NAME: | Surgical faceshields  |
|  CLASSIFICATION: | 878.4040 Surgical apparel  |
|  DEVICE PRODUCT CODE: | 79 FXX  |
|  SUBSTANTIALLY EQUIVALENT DEVICES: | - Splash Shield Splash Shields
- DePuy Disposable Filter/Hood
- DePuy Shades™ Protective Glasses  |

## INTENDED USE:

The DePuy Opti-Con and E-Z Shield Systems are intended as face shields to be worn by operating room personnel during surgical procedures to provide splash protection to protect the operating room personnel from the transfer of microorganisms, body fluids and particulate material. The Opti-Con Shields, E-Z Shield and Opti-Con goggles are intended to be disposable. The Opti-Con head gear is intended to be re-usable.

## DEVICE DESCRIPTIONS AND SUBSTANTIAL EQUIVALENCE RATIONALES:

The Opti-Con Faceshield System consists of a disposable faceshield which is designed to provide splash protection to the wearer’s eyes, nose, mouth and ears during surgical procedures and re-usable headgear which fits over the top of the head and holds the faceshield in place. The disposable faceshields are manufactured from polycarbonate and are available in a standard and a long length, either sterile or non-sterile. The Opti-Con Faceshields are substantially equivalent to the Splash Shield Splash Shields in that they have similar designs and the same intended use. Impact testing of both designs demonstrates that the impact resistance of the Opti-Con Shields is greater than that of the Splash Shield Splash Shields.

The E-Z Shield is a one-piece disposable faceshield and headband which is also designed to provide splash protection to the wearer’s eyes, nose, mouth and ears during surgical procedures. The E-Z Shield is identical to the Splash Shield Splash Shield but is relabeled by DePuy. The E-Z Shield is manufactured from PETG as is the faceshield of the DePuy Disposable Filter/Hood.

The Opti-Con goggles are disposable goggles designed to protect the eyes during surgical procedures. They are substantially equivalent to the DePuy Shades Protective Glasses in that they have similar designs, the same intended use, and both are manufactured from polycarbonate.

---

**Source:** [https://fda.innolitics.com/submissions/HO/subpart-e%E2%80%94surgical-devices/FXX/K964114](https://fda.innolitics.com/submissions/HO/subpart-e%E2%80%94surgical-devices/FXX/K964114)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
