HEMOSIL SPECIAL TEST CONTROLS LEVEL 1 & 2

K040359 · Instrumentation Laboratory CO · JPA · Mar 19, 2004 · Hematology

Device Facts

Record IDK040359
Device NameHEMOSIL SPECIAL TEST CONTROLS LEVEL 1 & 2
ApplicantInstrumentation Laboratory CO
Product CodeJPA · Hematology
Decision DateMar 19, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 864.5425
Device ClassClass 2

Indications for Use

The intended use to HemosIL Special Test Controls Level 1 & 2 is being expanded with the addition of value assignments for chromogenic Factor VIII tests (Levels 1 and 2) and clotting factor assays (Level 2 only). There are no changes in product formulation or alterations in the fundamental scientific technology introduced with the new value assignments. HemosIL Special Test Controls Level 1 & 2 is labeled: - For the quality control in the abnormal range of the chromogenic tests (Antithrombin, Plasminogen, Plasmin Inhibitor, Protein C and Factor VIII) and Free Protein S assay performed on the IL Coagulation Systems. - For the Quality Control of von Willebrand Factor assay in the normal (Level 1) and abnormal range (Level 2) on the IL Coagulation Systems. - For the Quality Control of factor assays (clotting) in the abnormal range (Level 2) on the IL Coagulation Systems.

Device Story

Lyophilized human plasma control; contains buffer and stabilizers; used for quality control of coagulation assays on IL Coagulation Systems; assesses precision and accuracy of chromogenic, clotting, and protein assays; provides abnormal range values for monitoring patient testing; used in clinical laboratory settings by laboratory personnel; ensures reliability of diagnostic results for patients undergoing thrombolytic therapy or coagulation testing.

Clinical Evidence

No clinical data. Bench testing only. Performance established via traceability to WHO International Standards (e.g., 94/746, 97/586) and internal house standards for parameters lacking international references. Precision and accuracy assessed via multiple runs on IL Coagulation Systems.

Technological Characteristics

Lyophilized human plasma; contains buffer and stabilizers. Designed for use on IL Coagulation Systems. Traceable to WHO International Standards or internal house standards. No electronic or software components.

Indications for Use

Indicated for use as a quality control material for human plasma-based coagulation assays, including chromogenic tests (Antithrombin, Plasminogen, Plasmin Inhibitor, Protein C, Factor VIII), Free Protein S, von Willebrand Factor, and clotting factor assays on IL Coagulation Systems.

Regulatory Classification

Identification

A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated instrument and its associated reagents and controls. The system is used to perform a series of coagulation studies and coagulation factor assays.

Special Controls

*Classification.* Class II (special controls). A control intended for use with a multipurpose system for in vitro coagulation studies is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY DEVICE ONLY TEMPLATE A. 510(k) Number: K040359 B. Analyte: Antithrombin, Plasminogen, Plasmin Inhibitor, Protein C, Protein S, von Willebrand Factor, Factors II, V, VII, VIII, IX, X, XI, XII C. Type of Test: N/A D. Applicant: Instrumentation Laboratory Company E. Proprietary and Established Names: HemosIL Special Test Control Level 1 & 2 F. Regulatory Information: 1. Regulation section: 864.5425 2. Classification: Class II 3. Product Code: JPA 4. Panel: Hematology (81) G. Intended Use: HemosIL Special Test Control Level 1 & 2 is human plasma used for quality control as follows: - In the abnormal range of the chromogenic tests (Antithrombin, Plasminogen, Plasmin Inhibitor, Protein C and Factor VIII) and Free Protein S assay on the IL Coagulation Systems - Of von Willebrand Factor assay in the normal (Level 1) and abnormal (Level 2) on the IL Coagulation Systems - Of factor assays (clotting) in the abnormal range (Level 2) on the IL Coagulation Systems 1. Indication for use: HemosIL Special Test Control Level 1 & 2 is human plasma used for quality control as follows: {1} Page 2 of 4 - In the abnormal range of the chromogenic tests (Antithrombin, Plasminogen, Plasmin Inhibitor, Protein C and Factor VIII) and Free Protein S assay on the IL Coagulation Systems - Of von Willebrand Factor assay in the normal (Level 1) and abnormal (Level 2) on the IL Coagulation Systems - Of factor assays (clotting) in the abnormal range (Level 2) on the IL Coagulation Systems 2. Special condition for use statement(s): Not Applicable 3. Special instrument Requirements: HemosIL Special Test Control Level 1 & 2 is for use on the IL Coagulation Systems. ## H. Device Description: HemosIL Special Test Control Level 1 & 2 is lyophilized human plasma containing buffer and stabilizers. ## I. Substantial Equivalence Information: 1. Predicate device name: HemosIL Special Test Controls Level 1 & 2 2. Predicate K number: K864271 3. Comparison with predicate: | Similarities | | | | --- | --- | --- | | Item | Predicate | Device | | | HemosIL Special Test Control Level 1 & 2 (K864271) | HemosIL Special Test Controls Level 1 & 2 | | Intended use | For the quality control in the abnormal range of the chromogenic tests (Antithrombin, Plasminogen, Plasmin Inhibitor and Protein C) and Free Protein S. For the quality control of von Willebrand Factor assay in the normal (Level 1) and abnormal range (Level 2). | Same with addition of Factor VIII (Level 1 and 2), and the addition of a quality control for factor assays (clotting) in the abnormal range (Level 2). | | Test Principle | Level 1: Abnormal levels for the chromogenic tests and the Free Protein assay in the range of 50-60% activity. It is intended for the assessment of precision and accuracy of the tests in the mid abnormal range. | Level 1: Same | {2} Page 3 of 4 | | Von Willebrand Factor values are within the normal range. **Level 2:** Abnormal levels for chromogenic test and the Free Protein S assay in the range of 20-30% activity. It is intended for the assessment of precision and accuracy of the chromogenic tests for patients undergoing thrombolytic therapy. Von Willebrand Factor values are in the low abnormal range. | **Level 2:** Abnormal levels for chromogenic test and the Free Protein S and factor assays (clotting) in the range of 20-40% activity. It is intended for the assessment of precision and accuracy of chromogenic tests for patients undergoing thrombolytic therapy. Same | | --- | --- | --- | ## J. Standard/Guidance Document Referenced (if applicable): National Committee for Clinical Laboratory Standards, Preparation and Testing of Reagent Water in the Clinical Laboratory, NCCLS Document C3-A3; Vol 17 No 18 ## K. Test Principle: Not Applicable ## L. Performance Characteristics (if/when applicable): 1. Analytical performance: a. Precision/Reproducibility: N/A b. Linearity/assay reportable range: N/A c. Traceability (controls, calibrators, or method): The reported values in the product insert are determined over multiple runs on IL Coagulation Systems using a specific lot of reagent and against a Calibration Plasma House Standard, which is traceable to the current International Standards. See below: | Test | WHO Standard Code No. | | --- | --- | | Chromogenic Factor VIII* | House Calibrator Standard | | Factor II | 94/746 | | Factor V* | House Calibrator Standard | | Factor VII | 94/746 | | Factor VIII | 97/586 | | Factor IX | 94/746 | | Factor X | 94/746 | | Factor XI* | House Calibrator Standard | | Factor XII* | House Calibrator Standard | *For the tests where International Standards are not available, these parameters have been assigned against a House Standard which is traceable to a frozen normal plasma pool of 100 donors following an internal Quality Control Procedure. {3} d. Detection limit: N/A e. Analytical specificity: N/A f. Assay cut-off: N/A 2. Comparison studies: a. Method comparison with predicate device: N/A b. Matrix comparison: N/A 3. Clinical studies: a. Clinical sensitivity: N/A b. Clinical specificity: N/A c. Other clinical supportive data (when a and b are not applicable): 4. Clinical cut-off: N/A 5. Expected values/Reference range: Refer to specific reagent inserts for performance characteristics. The reported ranges were determined over multiple runs on IL Coagulation Systems using specific lots of IL reagents. The mean of the control range determined in the user's laboratory may vary due to the lot of reagent used. M. Conclusion: Based on the review of the information provided, the HemosIL Special Test Control Level 1 & 2 is substantially equivalent (SE) to devices regulated under 21 CFR 864.5425, system, multipurpose for in vitro coagulation studies, product code JPA.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...