KDI · Dialyzer, High Permeability With Or Without Sealed Dialysate System

Gastroenterology, Urology · 21 CFR 876.5860 · Class 2

Overview

Product CodeKDI
Device NameDialyzer, High Permeability With Or Without Sealed Dialysate System
Regulation21 CFR 876.5860
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A high permeability hemodialysis system is a device intended for use as an artificial kidney system for the treatment of patients with renal failure, fluid overload, or toxemic conditions by performing such therapies as hemodialysis, hemofiltration, hemoconcentration, and hemodiafiltration. Using a hemodialyzer with a semipermeable membrane that is more permeable to water than the semipermeable membrane of the conventional hemodialysis system (§ 876.5820), the high permeability hemodialysis system removes toxins or excess fluid from the patient's blood using the principles of convection (via a high ultrafiltration rate) and/or diffusion (via a concentration gradient in dialysate). During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment. The hemodialysis delivery machine controls and monitors the parameters related to this processing, including the rate at which blood and dialysate are pumped through the system, and the rate at which fluid is removed from the patient. The high permeability hemodialysis system consists of the following devices:(1) The hemodialyzer consists of a semipermeable membrane with an in vitro ultrafiltration coefficient (K uf ) greater than 8 milliliters per hour per conventional millimeter of mercury, as measured with bovine or expired human blood, and is used with either an automated ultrafiltration controller or anther method of ultrafiltration control to prevent fluid imbalance.(2) The hemodialysis delivery machine is similar to the extracorporeal blood system and dialysate delivery system of the hemodialysis system and accessories (§ 876.5820), with the addition of an ultrafiltration controller and mechanisms that monitor and/or control such parameters as fluid balance, dialysate composition, and patient treatment parameters (e.g., blood pressure, hematocrit, urea, etc.). (3) The high permeability hemodialysis system accessories include, but are not limited to, tubing lines and various treatment related monitors (e.g., dialysate pH, blood pressure, hematocrit, and blood recirculation monitors).

Classification Rationale

Class II. The special controls for this device are FDA's:

Special Controls

*Classification.* Class II. The special controls for this device are FDA's:(1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Device—Part I: Evaluation and Testing,’ ” (2) “Guidance for the Content of 510(k)s for Conventional and High Permeability Hemodialyzers,” (3) “Guidance for Industry and CDRH Reviewers on the Content of Premarket Notifications for Hemodialysis Delivery Systems,” (4) “Guidance for the Content of Premarket Notifications for Water Purification Components and Systems for Hemodialysis,” and (5) “Guidance for Hemodialyzer Reuse Labeling.”

Recent Cleared Devices (20 of 343)

Showing 20 most recent of 343 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K260533ELISIO™-HNipro Medical CorporationMar 19, 2026SESE
K252459multiFlux 130 (F00013123); multiFlux 160 (F00013124)Fresenius Medical Care Renal Therapies Group, LLCFeb 10, 2026SESE
K253412Tablo Hemodialysis System (PN-0008000, PN-0006000U)Outset Medical, Inc.Jan 26, 2026SESE
K253518FX CorAL 40; FX CorAL 50Fresenius Medical Care Renal Therapies Group, LLCDec 18, 2025SESE
K243920Purema H Hemoconcentrator - PediatricMedica USA, Inc.Sep 19, 2025SESE
K250508AK 98 Dialysis Machine (955607)Vantive US Healthcare, LLCAug 1, 2025SESE
K2432372008T HD SYS. CDX BLUESTAR (191124); 2008T HD SYS. CDX W/bibag BLUESTAR (191126); 2008T HD SYS. W/O CDX BLUESTAR (191128); 2008T HD SYS. W/O CDX W/bibag BLUESTAR (191130)Fresenius Medical Care Renal Therapies Group, LLCJun 13, 2025SESE
K2435055008X Hemodialysis SystemFresenius Medical Care Renal Therapies Group, LLCMay 30, 2025SESE
K242155DBB-06 PRO Hemodialysis Delivery System (DBB-06 PRO)NIKKISO CO., LTD.May 15, 2025SESE
K243264DHF 0.2 Hemoconcentrator (DHF 02); DHF 0.6 Hemoconcentrator (DHF 06); SH 14 Hemoconcentrator (SH 14)Sorin Group Italia S.R.L.Apr 25, 2025SESE
K242053FX CorAL 40 (F00009214); FX CorAL 50 (F00009215)Fresenius Medical Care Renal Therapies Group, LLCMar 21, 2025SESE
K243874FX CorAL 60 (F00012969); FX CorAL 80 (F00012970); FX CorAL 100 (F00012971); FX CorAL 120 (F00012972); FX CorAL 600 (F00012973); FX CorAL 800 (F00012974); FX CorAL 1000 (F00012975)Fresenius Medical Care Renal Therapies Group, LLCFeb 28, 2025SESE
K233798Moda-flx Hemodialysis System and CartridgeDiality, Inc.Aug 2, 2024SESE
K233557HemoCare Hemodialysis SystemDeka Research and DevelopmentJul 12, 2024SESE
K240394multiFlux 1000 (F00012408)Fresenius Medical Care Renal Therapies Group, LLCMay 31, 2024SESE
K232776Tablo® Hemodialysis System; TabloCart™ with Prefiltration DrawerOutset Medical, Inc.May 3, 2024SESE
K232803NxStage System One with Cartridge Express (CAR-170-E and CAR-172-E)Nxstage Medical, Inc.Mar 14, 2024SESE
K232171Purema® H Hemoconcentrator (EtO Sterilized)Tecnoideal AmericaFeb 7, 2024SESE
K2315345008X Hemodialysis SystemFresenius Medical CareFeb 2, 2024SESE
K2311252008T BlueStar Hemodialysis MachineFresenius Medical Care Renal Therapies Group, LLCDec 6, 2023SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...