STA COMPACT AUTOMATED MULTI-PARAMETRIC ANALYZER

K093167 · Diagnostica Stago, Inc. · JPA · Dec 22, 2009 · Hematology

Device Facts

Record IDK093167
Device NameSTA COMPACT AUTOMATED MULTI-PARAMETRIC ANALYZER
ApplicantDiagnostica Stago, Inc.
Product CodeJPA · Hematology
Decision DateDec 22, 2009
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 864.5425
Device ClassClass 2

Indications for Use

The STA Compact® Automated Multi-Parametric Analyzer is a fully automatic clinical instrument designed to perform tests on human plasmas, the results of which aid in the diagnosis of coagulation abnormalities or in monitoring anticoagulant therapy.

Device Story

STA Compact Automated Multi-Parametric Analyzer; performs clinical laboratory analysis. Modifications include: new hardware/mechanical components for reliability; updated software for user enhancements; modified data post-processing; addition of Hook Effect Detection function. Device operates in clinical laboratory settings; used by laboratory technicians/personnel. Input: clinical samples; Output: analytical results. Hook Effect Detection improves result reliability by identifying potential assay interference. Healthcare providers use output for clinical decision-making.

Clinical Evidence

Bench testing only. Verification and validation activities performed per design control procedures (21 CFR 820.30). Risk analysis conducted to assess impact of modifications; results demonstrated predetermined acceptance criteria were met.

Technological Characteristics

Fully automatic multi-parametric analyzer. Performs chronometric and photometric assays. Features barcoding for reagent management. Software includes data post-processing for Hook Effect Detection. Hardware updated for reliability. No specific materials or connectivity standards provided.

Indications for Use

Indicated for use on human plasma samples to aid in the diagnosis of coagulation abnormalities or to monitor anticoagulant therapy.

Regulatory Classification

Identification

A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated instrument and its associated reagents and controls. The system is used to perform a series of coagulation studies and coagulation factor assays.

Special Controls

*Classification.* Class II (special controls). A control intended for use with a multipurpose system for in vitro coagulation studies is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

Predicate Devices

Submission Summary (Full Text)

{1} SPECIAL 510(k): Device Modification ODE Review Memorandum (Decision Making Document is Attached) To: THE FILE RE: DOCUMENT NUMBER K093167 This 510(k) submission contains information/data on modifications made to the SUBMITTER'S own Class II, Class III or Class I devices requiring 510(k). The following items are present and acceptable (delete/add items as necessary): 1. STA Compact® Automated Multi-Parametric Analyzer, K961579 previously cleared device. 2. Submitter's statement that the INDICATION/INTENDED USE of the modified device as described in its labeling HAS NOT CHANGED along with the proposed labeling which includes instructions for use, package labeling, and, if available, advertisements or promotional materials (labeling changes are permitted as long as they do not affect the intended use). 3. A description of the device MODIFICATION(S), including clearly labeled diagrams, engineering drawings, photographs, user's and/or service manuals in sufficient detail to demonstrate that the FUNDAMENTAL SCIENTIFIC TECHNOLOGY of the modified device has not changed. This change was for modifications which include: (1) new hardware and mechanical components to increase the operation reliability or obsolete components, (2) updated software to include operator/user use enhancements and (3) modification of the data post-processing to increase reliability of results. Additionally, the software consists of the addition of a quality improvement function which provides Hook Effect Detection. 4. Comparison Information (similarities and differences) to applicant's legally marketed predicate device including, labeling, intended use, physical characteristics, and assay methods. The difference is in minor hardware and mechanical components to increase the reliability of operation, software to provide operator/user use enhancements. 5. A Design Control Activities Summary which includes: a) Identification of Risk Analysis method(s) used to assess the impact of the modification on the device and its components, and the results of the analysis (Attachment 5A, 5B) b) Based on the Risk Analysis, an identification of the verification and/or validation activities required, including methods or tests used and acceptance criteria to be applied (Pages 9-11, Attachment 3C) c) A declaration of conformity with design controls. The declaration of conformity should include: i) A statement signed by the individual responsible, that, as required by the risk analysis, all verification and validation activities were performed by the designated individual(s) and the results demonstrated that the predetermined acceptance criteria were met, and (Attachment 1) ii) A statement signed by the individual responsible, that the manufacturing facility is in conformance with design control procedure requirements as specified in 21 CFR 820.30 and the records are available for review. (Attachment 1) 6. A Truthful and Accurate Statement, a 510(k) Summary and the Indications for Use Enclosure. The labeling for this modified subject device has been reviewed to verify that the indication/intended use for the device is unaffected by the modification. In addition, the submitter's description of the particular modification(s) and the comparative information between the modified and unmodified devices demonstrate that the fundamental scientific technology has not changed. The submitter has provided the design control information as specified in The New 510(k) Paradigm and on this basis, I recommend the device be determined substantially equivalent to the previously cleared (or their preamendment) device.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...