- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- MiscellaneousMiscellaneous
- Subpart B—Biological StainsCFR Sub-Part
- Subpart B—Diagnostic DevicesCFR Sub-Part
- Subpart C—Cell And Tissue Culture ProductsCFR Sub-Part
- Subpart C—Clinical Laboratory InstrumentsCFR Sub-Part
- Subpart E—Specimen Preparation ReagentsCFR Sub-Part
- Subpart F—Automated and Semi-Automated Hematology DevicesCFR Sub-Part
- Subpart F—General Hospital and Personal Use Therapeutic DevicesCFR Sub-Part
- Subpart F—Immunological Test SystemsCFR Sub-Part
- Subpart G—Manual Hematology DevicesCFR Sub-Part
- Subpart G—Tumor Associated Antigen immunological Test SystemsCFR Sub-Part
- Subpart H—Hematology Kits and PackagesCFR Sub-Part
- Subpart I—Hematology ReagentsCFR Sub-Part
- Subpart J—Products Used In Establishments That Manufacture Blood and Blood ProductsCFR Sub-Part
- Subpart K—Products Used In Establishments That Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps)CFR Sub-Part
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Oil, Clearing
- Page Type
- Product Code
- Regulation Medical Specialty
- Pathology
- Review Panel
- Hematology
- Submission Type
- 510(K) Exempt
- Device Classification
- Class 1
- Regulation Number
- 864.4010
- GMP Exempt?
- Yes
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Not Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 864.4010 General purpose reagent
§ 864.4010 General purpose reagent.
(a) A general purpose reagent is a chemical reagent that has general laboratory application, that is used to collect, prepare, and examine specimens from the human body for diagnostic purposes, and that is not labeled or otherwise intended for a specific diagnostic application. It may be either an individual substance, or multiple substances reformulated, which, when combined with or used in conjunction with an appropriate analyte specific reagent (ASR) and other general purpose reagents, is part of a diagnostic test procedure or system constituting a finished in vitro diagnostic (IVD) test. General purpose reagents are appropriate for combining with one or more than one ASR in producing such systems and include labware or disposable constituents of tests; but they do not include laboratory machinery, automated or powered systems. General purpose reagents include cytological preservatives, decalcifying reagents, fixative and adhesives, tissue processing reagents, isotonic solutions and pH buffers. Reagents used in tests for more than one individual chemical substance or ligand are general purpose reagents (e.g., Thermus aquaticus (TAQ) polymerase, substrates for enzyme immunoassay (EIA)).
(b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of § 820.180, with respect to general requirements concerning records, and § 820.198, with respect to complaint files.
[45 FR 60592, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 62 FR 62260, Nov. 21, 1997; 66 FR 38789, July 25, 2001]