- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- Cardiovascular Monitoring DevicesCFR Sub-Part
- Diagnostic DevicesCFR Sub-Part
- General Hospital and Personal Use Miscellaneous DevicesCFR Sub-Part
- MiscellaneousMiscellaneous
- Monitoring DevicesCFR Sub-Part
- Neurological Therapeutic DevicesCFR Sub-Part
- Obstetrical and Gynecological Diagnostic DevicesCFR Sub-Part
- Obstetrical and Gynecological Surgical DevicesCFR Sub-Part
- Physical Medicine Therapeutic DevicesCFR Sub-Part
- Prosthetic DevicesCFR Sub-Part
- Surgical DevicesCFR Sub-Part
- Therapeutic DevicesCFR Sub-Part
- EZTPacemaker, Bladder3Product Code
- EZWStimulator, Electrical, Implantable, For Incontinence3Product Code
- EZYDevice, Incontinence, Mechanical/Hydraulic3Product Code
- FAHDilator, Urethral, Mechanical2Product Code
- BSSTube, Nasogastric2Product Code
- EXASelector, Size, Ostomy1Product Code
- EXBCollector, Ostomy1Product Code
- EXDIrrigator, Ostomy2Product Code
- EXEProtector, Ostomy1Product Code
- EXFBag, Bile Collecting2Product Code
- EXGBag, Urine Collecting, Ureterostomy1Product Code
- EXHBag, Urinary, Ileostomy1Product Code
- EXIDevice, Paste-On For Incontinence, Sterile1Product Code
- EXJDevice, Incontinence, Urosheath Type, Sterile1Product Code
- EXNSupport, Hernia1Product Code
- EYAStylet, Ureteral1Product Code
- EYBCatheter, Ureteral, Gastro-Urology2Product Code
- EYCCatheter, Upper Urinary Tract2Product Code
- EYIAdaptor, Ureteral Catheter1Product Code
- EYJHolder, Ureteral Catheter1Product Code
- EYKConnector, Ureteral Catheter1Product Code
- EYQGarment, Protective, For Incontinence1Product Code
- EYTSheath, Corrugated Rubber, For Nonindwelling Catheter, Sterile1Product Code
- EYZSystem, Urine Drainage, Closed, For Nonindwelling Catheter, Sterile1Product Code
- EZBStylet For Catheter, Gastro-Urology1Product Code
- EZCCatheter, Coude2Product Code
- EZDCatheter, Straight2Product Code
- EZKCatheter, Retention Type2Product Code
- EZLCatheter, Retention Type, Balloon2Product Code
- EZMDilator, Esophageal (Metal Olive) Gastro-Urology2Product Code
- EZNDilator, Catheter, Ureteral2Product Code
- EZQPouch, Colostomy1Product Code
- EZRCement, Stomal Appliance, Ostomy1Product Code
- EZSAppliance, Colostomy, Disposable1Product Code
- FAQBag, Urine Collection, Leg, For External Use, Sterile1Product Code
- FATBougie, Esophageal, And Gastrointestinal, Gastro-Urology2Product Code
- FAXBougie, Urological1Product Code
- FBMCannula And Trocar, Suprapubic, Non-Disposable1Product Code
- FBRUrethrometer1Product Code
- FBWFiliform And Filiform Follower1Product Code
- FBXSound, Urethral, Metal Or Plastic1Product Code
- FCBBag, Hemostatic2Product Code
- FCEEnema Kit1Product Code
- FCMTray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)2Product Code
- FCNUrinary Drainage Collection Kit, For Indwelling Catheter2Product Code
- FEFTube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression2Product Code
- FEGTube, Double Lumen For Intestinal Decompression And/Or Intubation2Product Code
- FEWCatheter, Malecot2Product Code
- FEXInstrument, Catheter, Punch1Product Code
- FEZCatheter And Tube, Suprapubic2Product Code
- FFATube, Drainage, Suprapubic2Product Code
- FFHCollector, Urine, Pediatric, For Indwelling Catheter2Product Code
- FFPDilator, Rectal1Product Code
- FFWString And Tubes, Gastrointestinal, To Locate Internal Bleeding2Product Code
- FGDCatheter, Retention, Barium Enema With Bag2Product Code
- FGEStents, Drains And Dilators For The Biliary Ducts2Product Code
- FGFCatheter, Ureteral Disposable (X-Ray)2Product Code
- FGHCatheter, Double Lumen Female Urethrographic2Product Code
- FGICatheter, Urethrographic, Male2Product Code
- FHAClamp, Penile1Product Code
- FHSDialyzer, Single Coil2Product Code
- FHTSet, Gavage, Infant, Sterile2Product Code
- FIAChair, Dialysis, Unpowered, Without Scales1Product Code
- FIBProtector, Transducer, Dialysis2Product Code
- FIDTubing, Dialysate2Product Code
- FIENeedle, Fistula2Product Code
- FIFSet, Dialysis, Single Needle With Uni-Directional Pump2Product Code
- FIGClamp, Tubing, Blood, Automatic2Product Code
- FIHPump, Infusion Or Syringe, Extra-Luminal2Product Code
- FIISystem, Dialysate Delivery, Sealed2Product Code
- FIJSystem, Dialysate Delivery, Recirculating, Single Pass2Product Code
- FIKSystem, Dialysate Delivery, Recirculating2Product Code
- FILSystem, Dialysate Delivery, Single Pass2Product Code
- FINTank, Holding, Dialysis2Product Code
- FIPSubsystem, Water Purification2Product Code
- FIQCannula, A-V Shunt2Product Code
- FIRPump, Blood, Extra-Luminal2Product Code
- FISFlowmeter, Dialysate2Product Code
- FIWAlarm, Pillow Pressure2Product Code
- FIZMeter, Conductivity, Non-Remote2Product Code
- FJAManometer, Water2Product Code
- FJBDetector, Dialysate Level2Product Code
- FJCDetector, Blood Level2Product Code
- FJDDetector, Leak, Blood2Product Code
- FJFDetector, Air Bubble2Product Code
- FJGDialyzer, Parallel Flow2Product Code
- FJHDialyzer, Disposable2Product Code
- FJIDialyzer, Capillary, Hollow Fiber2Product Code
- FJJDialyzer, Twin Coil2Product Code
- FJKSet, Tubing, Blood, With And Without Anti-Regurgitation Valve2Product Code
- FJMGuard, Shunt2Product Code
- FJNStabilizer, Shunt2Product Code
- FJOPlier, Tube1Product Code
- FJPAdaptor, Y2Product Code
- FJQConnector, Shunt1Product Code
- FJRForceps, Disconnect1Product Code
- FJSCatheter, Peritoneal, Long-Term Indwelling2Product Code
- FJTIntracatheter, Dialysis2Product Code
- FJWRing, Joint1Product Code
- FJXRing, Crimp1Product Code
- FJYPlier, Crimp1Product Code
- FJZDeclotting Tray, Kit (Including Contents)2Product Code
- FKADilator, Vessel2Product Code
- FKBConnector, Blood Tubing, Infusion T2Product Code
- FKCClamp, Cannula1Product Code
- FKDCanister, Coil2Product Code
- FKETie, Dialysis1Product Code
- FKFGun, Tie, Dialysis1Product Code
- FKGTray, Start/Stop (Including Contents), Dialysis1Product Code
- FKHSolution-Test Standard-Conductivity, Dialysis2Product Code
- FKISet, Dialyzer Holder2Product Code
- FKJFilter, Blood, Dialysis2Product Code
- FKLInsert, Pump, Blood2Product Code
- FKMAdaptor, Fistula2Product Code
- FKNAdaptor, Shunt2Product Code
- FKOCatheter, Peritoneal Dialysis, Single Use2Product Code
- FKPSystem, Dialysate Delivery, Single Patient2Product Code
- FKQSystem, Dialysate Delivery, Central Multiple Patient2Product Code
- FKRSubsystem, Proportioning2Product Code
- FKTSystem, Dialysate Delivery, Sorbent Regenerated2Product Code
- FKWTip, Vessel2Product Code
- FKXSystem, Peritoneal, Automatic Delivery2Product Code
- FKYConnector, Tubing, Dialysate2Product Code
- FLAMonitor, Temperature, Dialysis2Product Code
- FLBMeter, Conductivity, Induction, Remote Type2Product Code
- FLCStation, Dialysis Control, Negative Pressure Type2Product Code
- FLDApparatus, Hemoperfusion, Sorbent2Product Code
- FOCBag, Urine Collection, Newborn2Product Code
- FONBag, Drainage, With Adhesive, Ostomy1Product Code
- FPDTube, Feeding2Product Code
- FRQTube, Levine2Product Code
- GBLCatheter, Ureteral, General & Plastic Surgery2Product Code
- GBMCatheter, Urethral2Product Code
- GBTCatheter, Rectal2Product Code
- GCABiliary Catheter For Stone Removal That May Also Allow For Irrigation And Contrast Injection2Product Code
- GDSBag, Stomal1Product Code
- KDHCatheter (Gastric, Colonic, Etc.), Irrigation And Aspiration2Product Code
- KDIDialyzer, High Permeability With Or Without Sealed Dialysate System2Product Code
- KDJSet, Administration, For Peritoneal Dialysis, Disposable2Product Code
- KDKContainer, Transport, Kidney2Product Code
- KDLSet, Perfusion, Kidney, Disposable2Product Code
- KDNSystem, Perfusion, Kidney2Product Code
- KGCTube, Gastro-Enterostomy2Product Code
- KNQDilator, Esophageal2Product Code
- KNRAdapter, A-V Shunt Or Fistula2Product Code
- KNTTubes, Gastrointestinal (And Accessories)2Product Code
- KNXCollector, Urine, (And Accessories) For Indwelling Catheter2Product Code
- KNYAccessories, Catheter, G-U2Product Code
- KNZAccessories, A-V Shunt2Product Code
- KOBCatheter, Suprapubic (And Accessories)2Product Code
- KOCAccessories, Blood Circuit, Hemodialysis2Product Code
- KODCatheter, Urological2Product Code
- KOEDilator, Urethral2Product Code
- KPFSystem, Dialysate Delivery, Semi-Automatic, Peritoneal2Product Code
- KPHCatheter, Rectal For Continent Ileostomy1Product Code
- KPIStimulator, Electrical, Non-Implantable, For Incontinence2Product Code
- KPLColonic Irrigation System2Product Code
- KPMShunt, Peritoneal2Product Code
- KPODialysate Concentrate For Hemodialysis (Liquid Or Powder)2Product Code
- KPPPeritoneal Dialysate Filter2Product Code
- KQQTubing, Dialysate (And Connector)2Product Code
- KQRDetector, Air Or Foam2Product Code
- KXMSystem Accessories, Extracorporeal2Product Code
- LBWSet, Dialysis, Single Needle (Co-Axial Flow)2Product Code
- LCGIntestinal Splinting Tubes2Product Code
- LFJCatheter, Subclavian2Product Code
- LFKCatheter, Femoral2Product Code
- LIFDialyzer Reprocessing System2Product Code
- LJHSystem, Irrigation, Urological2Product Code
- LKYDevice, External Penile Rigidity2Product Code
- LLBSystem, Blood, Extracorporeal And Accessories2Product Code
- LNSLithotriptor, Extracorporeal Shock-Wave, Urological2Product Code
- LQRDislodger, Stone, Biliary2Product Code
- LRIPh Meter For Dialysis Hydrogen Ion Concentration2Product Code
- MJCCatheter, Urological (Antimicrobial) And Accessories2Product Code
- MLWWarmer, Peritoneal Dialysate2Product Code
- MNGExternal Urethral Occluder, Urinary Incontinence-Control, Female1Product Code
- MNVStrip, Dialysate Ph Indicator2Product Code
- MONSystem, Hemodialysis, Remote Accessories1Product Code
- MPBCatheter, Hemodialysis, Non-Implanted2Product Code
- MQSSystem, Hemodialysis, Access Recirculation Monitoring2Product Code
- MSBSystem And Accessories, Isolated Heart, Transport And Preservation2Product Code
- MSDCatheter, Hemodialysis, Implanted2Product Code
- MSEHemodialyzer, Re-Use, Low Flux2Product Code
- MSFHemodialyzer, Re-Use, High Flux2Product Code
- MSYStrip, Test, Reagent, Residuals For Dialysate, Disinfectant2Product Code
- MSZStrip, Test, Reagent, Residuals For Dialysate2Product Code
- NAMStimulator, Peripheral Nerve, Non-Implanted, For Pelvic Floor Dysfunction2Product Code
- NDSMedia, Culture, Ex Vivo, Tissue And Cell2Product Code
- NFKKit, Repair, Catheter, Hemodialysis2Product Code
- NHVSystem, Water Purification, General Medical Use2Product Code
- NIECatheter, Hemodialysis, Triple Lumen, Non-Implanted2Product Code
- NIFCatheter, Hemodialysis, Triple Lumen, Implanted2Product Code
- NMLCatheter, Biliary, Reprocessed2Product Code
- NNENeedle, Fistula, Reprocessed2Product Code
- NNGSet, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed2Product Code
- NNWBag, Urine Collection, Leg, For External Use, Non-Sterile1Product Code
- NNXDevice, Incontinence, Urosheath Type, Non-Sterile1Product Code
- NNYSheath, Corrugated Rubber, For Non-Indwelling Catheter, Non-Sterile1Product Code
- NNZSystem, Urine Drainage, Closed, For Non-Indwelling Catheter, Non-Sterile1Product Code
- NOADevice, Paste-On For Incontinence, Non-Sterile1Product Code
- NOOClamp, Dialysis Arm1Product Code
- NOYAgents, Embolic, For Treatment Of Benign Prostatic Hyperplasia2Product Code
- NQJCatheter, Hemodialysis, Non-Implanted, Ultrafiltration, For Peripheral Use2Product Code
- NTZStrip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator2Product Code
- NUBColonic Irrigation System, General Well Being3Product Code
- NYUCatheter, Hemodialysis, Implanted, Coated2Product Code
- NWOKit, Catheter, Urinary (Exludes Hiv Testing)2Product Code
- NWPSuprapubic Cystostomy Catheter Kit2Product Code
- NWQKit, Catheter, External, Male (Excludes Hiv Testing)2Product Code
- NWRKit, Catheter, Foley (Excludes Hiv Testing)2Product Code
- NZUCollector, Urine, Powered, Non Indwelling Catheter1Product Code
- ODNUltrafiltration-Controlled Nocturnal Dialysate Delivery System2Product Code
- ODXAutonomous Extracorporeal Blood Leak Detector/Alarm2Product Code
- OHRCatheter Care Tray2Product Code
- ONWHemodialysis System For Home Use2Product Code
- ONYOral Removable Retainer For Weight Management2Product Code
- PBPRectal Insert2Product Code
- PCUPancreatic Stent, Covered, Metallic, Removable2Product Code
- PEHHemodialysis Catheter Luer End Cap2Product Code
- PEVDialysis Administration Kit2Product Code
- PEWImplantable Transprostatic Tissue Retractor System2Product Code
- PFHVenous Window Needle Guide2Product Code
- PIAVibrator For Climax Control Of Premature Ejaculation2Product Code
- PIDEsophageal Dilator Balloon With Or Without Electrode Sensors2Product Code
- PIEEsophageal Dilator With Balloon And Electrode Sensors2Product Code
- PIFGastrointestinal Tubes With Enteral Specific Connectors2Product Code
- QGCSuprapubic Catheter Accessories1Product Code
- PIHUrethral Insert With Pump For Bladder Drainage2Product Code
- PINKidney Perfusion Kit2Product Code
- PIOEnteral Specific Transition Connectors2Product Code
- PJHDynamic Rectal Control System2Product Code
- PKIFully Subcutaneous Implanted Hemodialysis Catheter2Product Code
- PLIGastrointestional Tube Holder2Product Code
- PLQEnzyme Packed Cartridge2Product Code
- PNBBiliary Stent System For Benign Strictures2Product Code
- PNGPeritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling2Product Code
- PNREnteral Syringes With Enteral Specific Connectors2Product Code
- QFQIngested, Transient, Space Occupying Device For Weight Management And/Or Weight Loss2Product Code
- PPABladder Irrigation Kit2Product Code
- PPBFoley Catheter Kit (Excludes Hiv Testing)2Product Code
- PPCMale External Catheterization Kit (Excludes Hiv Testing)2Product Code
- PPDUniversal Drainage Tray2Product Code
- PPFUrinary Irrigation Kit2Product Code
- PPGUrinary Drainage Collection Kit2Product Code
- PPHSingle Needle With Uni-Directional Pump Kit2Product Code
- PPIHemodialysis Tray (Not A Start/Stop Kit)2Product Code
- PPJPeritoneal Dialysis Administration Kit2Product Code
- PPKPeritoneal Dialysis Tubing Kit2Product Code
- PPLSingle Needle (Co-Axial Flow) Dialysis Kit2Product Code
- PPOMulti-Lumen Hemodialysis Catheterization Kit2Product Code
- PQEOstomy Care Kit1Product Code
- PRMEnteral Administration Kit (Adult & Pediatric)2Product Code
- PROAnti-Regurgitation Blood Tubing Kit2Product Code
- PRPBalloon Gastrostomy Tube Kit2Product Code
- PRQEsophageal Dilator Kit2Product Code
- PRRFeeding Tube Kit2Product Code
- PRSGastric Colonic Catheter Irrigation Kit2Product Code
- PRTGastric Irrigation And Aspiration Kit2Product Code
- PRWGastrointestinal Tube Kit2Product Code
- PRXGastrostomy Guide Wire Placement Kit2Product Code
- PRYGastrostomy Jejunostomy Feeding Tube Kit2Product Code
- PRZGastrostomy Tube Kit2Product Code
- PSALaparoscopic Jejunostomy Kit2Product Code
- PSBNasogastric Feed Tube Kit2Product Code
- PSCNasogastric-Gastrojejunal Kit2Product Code
- PSDLaparoscopic Gastrostomy Kit2Product Code
- PSENeedle Catheter Jejunostomy Kit2Product Code
- PSFNon-Balloon Replacement Gastrostomy System2Product Code
- PSGPercutaneous Endoscopic Gastrostomy Kit2Product Code
- PSHPercutaneous Replacement Gastrostomy Tube Kit2Product Code
- PSJRectal Dilator Kit1Product Code
- PSKReplacement Gastrostomy Feeding Catheter Tray2Product Code
- PSXChlorine Meter2Product Code
- PTKPediatric Esophageal Atresia Anastomosis Device3Product Code
- PTTBiliary Catheter For Irrigation And Contrast Injection, Exempt2Product Code
- PTUCatheter, Peritoneal, Long-Term Indwelling, Exempt2Product Code
- PTVCatheter, Peritoneal Dialysis, Single Use, Exempt2Product Code
- PTWSystem, Peritoneal, Automatic Delivery, Exempt2Product Code
- QAJCutaneous Electrode Stimulator For Urinary Incontinence2Product Code
- QGDImplanted Mechanical/Hydraulic Urinary Continence Device Surgical Accessories1Product Code
- QGEBiliary Stent, Drain, And Dilator Accessories1Product Code
- QONImplanted Electrical Device Intended For Treatment Of Fecal Incontinence3Product Code
- QRCNon-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation2Product Code
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Pancreatic Stent, Covered, Metallic, Removable
- Page Type
- Product Code
- Definition
- To facilitate transmural endoscopic drainage of pancreatic pseudocysts
- Physical State
- stent and delivery system, endoscope
- Technical Method
- Facilitates and secures the apposition of tissue for transmural placement of stent
- Target Area
- pancreatic pseudocysts adherent to bowel wall
- Regulation Medical Specialty
- Gastroenterology and Urology
- Review Panel
- Gastroenterology and Urology
- Submission Type
- 510(K)
- Device Classification
- Class 2
- Regulation Number
- 876.5015
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- Yes
- Life-Sustain/Support Device
- No
- Third Party Review
- Not Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 876.5015 Pancreatic drainage stent and delivery system
§ 876.5015 Pancreatic drainage stent and delivery system.
(a) Identification. A pancreatic drainage stent is a prescription device that consists of a self-expanding, covered, metallic stent, intended for placement to facilitate transmural endoscopic drainage of pancreatic pseudocysts. This stent is intended to be removed upon confirmation of pseudocyst resolution. This device may also include a delivery system.
(b) Classification. Class II (special controls). The special controls for this device are:
(1) The device and elements of the delivery device that may contact the patient must be demonstrated to be biocompatible.
(2) Performance data must demonstrate the sterility of patient-contacting components of the device.
(3) Performance data must support the shelf life of the device by demonstrating continued sterility, package integrity, and device functionality over the requested shelf life.
(4) Non-clinical testing data must demonstrate that the stent and delivery system perform as intended under anticipated conditions of use. The following performance characteristics must be tested:
(i) Deployment testing of the stent and delivery system must be conducted under simulated use conditions.
(ii) Removal force testing must be conducted. The removal force testing must demonstrate that the stent can be safely removed, and that the stent will remain in place when subjected to forces encountered during use.
(iii) Expansion force testing must be conducted. The expansion force must demonstrate that the forces exerted by the stent will not damage the tissue surrounding the stent.
(iv) Compression force testing must be conducted. The compression force must demonstrate that the stent will withstand the forces encountered during use.
(v) Dimensional verification testing must be conducted.
(vi) Tensile testing of joints and materials must be conducted. The minimum acceptance criteria must be adequate for its intended use.
(vii) Fatigue testing must be conducted. Material strength must demonstrate that the stent will withstand forces encountered during use.
(viii) Corrosion testing must be conducted. Corrosion resistance must demonstrate that the stent will withstand conditions encountered during use.
(5) Non-clinical testing must evaluate the compatibility of the stent in a magnetic resonance (MR) environment.
(6) Well-documented clinical experience must demonstrate safe and effective use, and capture any adverse events observed during clinical use.
(7) Labeling must include the following:
(i) Appropriate instructions, warnings, cautions, limitations, and information related to the safe use of the device, including deployment of the device, maintenance of the drainage lumen, and removal of the device.
(ii) A warning that the safety and patency of the stent has not been established beyond the duration of the documented clinical experience.
(iii) Specific instructions and the qualifications and clinical training needed for the safe use of the device, including deployment of the device, maintenance of the drainage lumen, and removal of the device.
(iv) Information on the patient population for which the device has been demonstrated to be effective.
(v) A detailed summary of the clinical experience pertinent to use of the device.
(vi) A detailed summary of the device technical parameters.
(vii) A detailed summary of the device- and procedure-related complications pertinent to use of the device.
(viii) An expiration date/shelf life.
[79 FR 30724, May 29, 2014]