We're working on improving this tool, so please
email us
suggestions.
Sign up
for email updates to learn about new features.
✕
FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
Cardiovascular Monitoring Devices
CFR Sub-Part
Diagnostic Devices
CFR Sub-Part
General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
Miscellaneous
Miscellaneous
Monitoring Devices
CFR Sub-Part
Neurological Therapeutic Devices
CFR Sub-Part
Obstetrical and Gynecological Diagnostic Devices
CFR Sub-Part
Obstetrical and Gynecological Surgical Devices
CFR Sub-Part
Physical Medicine Therapeutic Devices
CFR Sub-Part
Prosthetic Devices
CFR Sub-Part
Surgical Devices
CFR Sub-Part
Therapeutic Devices
CFR Sub-Part
EZT
Pacemaker, Bladder
3
Product Code
EZW
Stimulator, Electrical, Implantable, For Incontinence
3
Product Code
EZY
Device, Incontinence, Mechanical/Hydraulic
3
Product Code
FAH
Dilator, Urethral, Mechanical
2
Product Code
BSS
Tube, Nasogastric
2
Product Code
EXA
Selector, Size, Ostomy
1
Product Code
EXB
Collector, Ostomy
1
Product Code
EXD
Irrigator, Ostomy
2
Product Code
EXE
Protector, Ostomy
1
Product Code
EXF
Bag, Bile Collecting
2
Product Code
EXG
Bag, Urine Collecting, Ureterostomy
1
Product Code
EXH
Bag, Urinary, Ileostomy
1
Product Code
EXI
Device, Paste-On For Incontinence, Sterile
1
Product Code
EXJ
Device, Incontinence, Urosheath Type, Sterile
1
Product Code
EXN
Support, Hernia
1
Product Code
EYA
Stylet, Ureteral
1
Product Code
EYB
Catheter, Ureteral, Gastro-Urology
2
Product Code
EYC
Catheter, Upper Urinary Tract
2
Product Code
EYI
Adaptor, Ureteral Catheter
1
Product Code
EYJ
Holder, Ureteral Catheter
1
Product Code
EYK
Connector, Ureteral Catheter
1
Product Code
EYQ
Garment, Protective, For Incontinence
1
Product Code
EYT
Sheath, Corrugated Rubber, For Nonindwelling Catheter, Sterile
1
Product Code
EYZ
System, Urine Drainage, Closed, For Nonindwelling Catheter, Sterile
1
Product Code
EZB
Stylet For Catheter, Gastro-Urology
1
Product Code
EZC
Catheter, Coude
2
Product Code
EZD
Catheter, Straight
2
Product Code
EZK
Catheter, Retention Type
2
Product Code
EZL
Catheter, Retention Type, Balloon
2
Product Code
EZM
Dilator, Esophageal (Metal Olive) Gastro-Urology
2
Product Code
EZN
Dilator, Catheter, Ureteral
2
Product Code
EZQ
Pouch, Colostomy
1
Product Code
EZR
Cement, Stomal Appliance, Ostomy
1
Product Code
EZS
Appliance, Colostomy, Disposable
1
Product Code
FAQ
Bag, Urine Collection, Leg, For External Use, Sterile
1
Product Code
FAT
Bougie, Esophageal, And Gastrointestinal, Gastro-Urology
2
Product Code
FAX
Bougie, Urological
1
Product Code
FBM
Cannula And Trocar, Suprapubic, Non-Disposable
1
Product Code
FBR
Urethrometer
1
Product Code
FBW
Filiform And Filiform Follower
1
Product Code
FBX
Sound, Urethral, Metal Or Plastic
1
Product Code
FCB
Bag, Hemostatic
2
Product Code
FCE
Enema Kit
1
Product Code
FCM
Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
2
Product Code
FCN
Urinary Drainage Collection Kit, For Indwelling Catheter
2
Product Code
FEF
Tube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression
2
Product Code
FEG
Tube, Double Lumen For Intestinal Decompression And/Or Intubation
2
Product Code
FEW
Catheter, Malecot
2
Product Code
FEX
Instrument, Catheter, Punch
1
Product Code
FEZ
Catheter And Tube, Suprapubic
2
Product Code
FFA
Tube, Drainage, Suprapubic
2
Product Code
FFH
Collector, Urine, Pediatric, For Indwelling Catheter
2
Product Code
FFP
Dilator, Rectal
1
Product Code
FFW
String And Tubes, Gastrointestinal, To Locate Internal Bleeding
2
Product Code
FGD
Catheter, Retention, Barium Enema With Bag
2
Product Code
FGE
Stents, Drains And Dilators For The Biliary Ducts
2
Product Code
FGF
Catheter, Ureteral Disposable (X-Ray)
2
Product Code
FGH
Catheter, Double Lumen Female Urethrographic
2
Product Code
FGI
Catheter, Urethrographic, Male
2
Product Code
FHA
Clamp, Penile
1
Product Code
FHS
Dialyzer, Single Coil
2
Product Code
FHT
Set, Gavage, Infant, Sterile
2
Product Code
FIA
Chair, Dialysis, Unpowered, Without Scales
1
Product Code
FIB
Protector, Transducer, Dialysis
2
Product Code
FID
Tubing, Dialysate
2
Product Code
FIE
Needle, Fistula
2
Product Code
FIF
Set, Dialysis, Single Needle With Uni-Directional Pump
2
Product Code
FIG
Clamp, Tubing, Blood, Automatic
2
Product Code
FIH
Pump, Infusion Or Syringe, Extra-Luminal
2
Product Code
FII
System, Dialysate Delivery, Sealed
2
Product Code
FIJ
System, Dialysate Delivery, Recirculating, Single Pass
2
Product Code
FIK
System, Dialysate Delivery, Recirculating
2
Product Code
FIL
System, Dialysate Delivery, Single Pass
2
Product Code
FIN
Tank, Holding, Dialysis
2
Product Code
FIP
Subsystem, Water Purification
2
Product Code
FIQ
Cannula, A-V Shunt
2
Product Code
FIR
Pump, Blood, Extra-Luminal
2
Product Code
FIS
Flowmeter, Dialysate
2
Product Code
FIW
Alarm, Pillow Pressure
2
Product Code
FIZ
Meter, Conductivity, Non-Remote
2
Product Code
FJA
Manometer, Water
2
Product Code
FJB
Detector, Dialysate Level
2
Product Code
FJC
Detector, Blood Level
2
Product Code
FJD
Detector, Leak, Blood
2
Product Code
FJF
Detector, Air Bubble
2
Product Code
FJG
Dialyzer, Parallel Flow
2
Product Code
FJH
Dialyzer, Disposable
2
Product Code
FJI
Dialyzer, Capillary, Hollow Fiber
2
Product Code
FJJ
Dialyzer, Twin Coil
2
Product Code
FJK
Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
2
Product Code
FJM
Guard, Shunt
2
Product Code
FJN
Stabilizer, Shunt
2
Product Code
FJO
Plier, Tube
1
Product Code
FJP
Adaptor, Y
2
Product Code
FJQ
Connector, Shunt
1
Product Code
FJR
Forceps, Disconnect
1
Product Code
FJS
Catheter, Peritoneal, Long-Term Indwelling
2
Product Code
FJT
Intracatheter, Dialysis
2
Product Code
FJW
Ring, Joint
1
Product Code
FJX
Ring, Crimp
1
Product Code
FJY
Plier, Crimp
1
Product Code
FJZ
Declotting Tray, Kit (Including Contents)
2
Product Code
FKA
Dilator, Vessel
2
Product Code
FKB
Connector, Blood Tubing, Infusion T
2
Product Code
FKC
Clamp, Cannula
1
Product Code
FKD
Canister, Coil
2
Product Code
FKE
Tie, Dialysis
1
Product Code
FKF
Gun, Tie, Dialysis
1
Product Code
FKG
Tray, Start/Stop (Including Contents), Dialysis
1
Product Code
FKH
Solution-Test Standard-Conductivity, Dialysis
2
Product Code
FKI
Set, Dialyzer Holder
2
Product Code
FKJ
Filter, Blood, Dialysis
2
Product Code
FKL
Insert, Pump, Blood
2
Product Code
FKM
Adaptor, Fistula
2
Product Code
FKN
Adaptor, Shunt
2
Product Code
FKO
Catheter, Peritoneal Dialysis, Single Use
2
Product Code
FKP
System, Dialysate Delivery, Single Patient
2
Product Code
FKQ
System, Dialysate Delivery, Central Multiple Patient
2
Product Code
FKR
Subsystem, Proportioning
2
Product Code
FKT
System, Dialysate Delivery, Sorbent Regenerated
2
Product Code
FKW
Tip, Vessel
2
Product Code
FKX
System, Peritoneal, Automatic Delivery
2
Product Code
FKY
Connector, Tubing, Dialysate
2
Product Code
FLA
Monitor, Temperature, Dialysis
2
Product Code
FLB
Meter, Conductivity, Induction, Remote Type
2
Product Code
FLC
Station, Dialysis Control, Negative Pressure Type
2
Product Code
FLD
Apparatus, Hemoperfusion, Sorbent
2
Product Code
FOC
Bag, Urine Collection, Newborn
2
Product Code
FON
Bag, Drainage, With Adhesive, Ostomy
1
Product Code
FPD
Tube, Feeding
2
Product Code
FRQ
Tube, Levine
2
Product Code
GBL
Catheter, Ureteral, General & Plastic Surgery
2
Product Code
GBM
Catheter, Urethral
2
Product Code
GBT
Catheter, Rectal
2
Product Code
GCA
Biliary Catheter For Stone Removal That May Also Allow For Irrigation And Contrast Injection
2
Product Code
GDS
Bag, Stomal
1
Product Code
KDH
Catheter (Gastric, Colonic, Etc.), Irrigation And Aspiration
2
Product Code
KDI
Dialyzer, High Permeability With Or Without Sealed Dialysate System
2
Product Code
KDJ
Set, Administration, For Peritoneal Dialysis, Disposable
2
Product Code
KDK
Container, Transport, Kidney
2
Product Code
KDL
Set, Perfusion, Kidney, Disposable
2
Product Code
KDN
System, Perfusion, Kidney
2
Product Code
KGC
Tube, Gastro-Enterostomy
2
Product Code
KNQ
Dilator, Esophageal
2
Product Code
KNR
Adapter, A-V Shunt Or Fistula
2
Product Code
KNT
Tubes, Gastrointestinal (And Accessories)
2
Product Code
K
22
0218
Siren SGT
2
Cleared 510(K)
K
22
0588
Avanos* CORTRAK* 2 Enteral Access System (EAS)
2
Cleared 510(K)
K
21
2444
Qora Stool Management Kit
2
Cleared 510(K)
K
21
2728
Standard Bougie, 38 Fr. and Hand Pump
2
Cleared 510(K)
K
21
0437
Standard Bougie, 38 Fr.
2
Cleared 510(K)
K
21
1072
Safety Trocar Cannula
2
Cleared 510(K)
K
20
2748
Enteral Feeding Catheter
2
Cleared 510(K)
K
20
3133
ENvizion Medical ENvue ENvizion Medical Enteral Feeding Tube
2
Cleared 510(K)
K
20
0646
TubeClear System
2
Cleared 510(K)
K
20
2539
Nutriglide(TM) Nasal Feeding Tube
2
Cleared 510(K)
K
20
1322
Entuit Nasal Jejunal Feeding Tube
2
Cleared 510(K)
K
19
1885
Standard Bougie
2
Cleared 510(K)
K
19
3325
Avantgarde Faecal Management Systems, Avantgarde Faecal Management System Replacement Pouches
2
Cleared 510(K)
K
19
0977
Navina Smart System, Navina Classic System
2
Cleared 510(K)
K
19
0084
McLean-Ring Enteral Feeding Tube Set
2
Cleared 510(K)
K
19
1387
ENvizion Medical ENVue SYSTEM, ENvizion Medical Enteral Feeding Tube
2
Cleared 510(K)
K
19
1340
CORTRAK* 2 Equilateral Enteral Access System
2
Cleared 510(K)
K
18
3336
Entuit PEG, Entuit PEGJ
2
Cleared 510(K)
K
18
3577
Medline Quick-Clear Wand
2
Cleared 510(K)
K
19
0114
Flexi-Seal PROTECT PLUS Fecal Management System (with ENFit Connector)
2
Cleared 510(K)
K
18
3508
Micro Transgastric-Jejunal Feeding Device
2
Cleared 510(K)
K
18
2804
Traditional Length GJ Feeding Device
2
Cleared 510(K)
K
18
2915
ENvizion Medical ENvue; ENvizion Medical Enteral Feeding Tube
2
Cleared 510(K)
K
18
2248
Aspire Venting Tube
2
Cleared 510(K)
K
18
0605
GastroFlush
2
Cleared 510(K)
K
18
0622
Kangaroo Gastrostomy Feeding Tube with ENFit Y-Port
2
Cleared 510(K)
K
18
0725
Aspire Introducer Needle
2
Cleared 510(K)
K
17
2556
TubeClear System
2
Cleared 510(K)
K
18
0026
Bowel Management Device, Bowel Management Irrigation Set
2
Cleared 510(K)
K
17
3955
Mic-Key* SF Over-the-Wire Stoma Measuring Device
2
Cleared 510(K)
K
17
3355
Gastric Sizing Balloon Catheter
2
Cleared 510(K)
K
16
2340
Stomach Tube
2
Cleared 510(K)
K
17
0319
Low Profile Non-Balloon Feeding Device
2
Cleared 510(K)
K
17
0487
Navina Classic System
2
Cleared 510(K)
K
16
0567
Barone Jejunostomy Catheter Set
2
Cleared 510(K)
K
16
0509
Tiger 2 Self-Advancing Nasal Jejunal Feeding Tube
2
Cleared 510(K)
K
16
3002
Kangaroo Feeding Tube with IRIS Technology
2
Cleared 510(K)
K
16
2906
Flexi-Seal PROTECT Fecal Management System
2
Cleared 510(K)
K
16
1413
Low Profile Balloon Feeding Device
2
Cleared 510(K)
K
16
3092
TubeClear Control Box and Clearing Stem
2
Cleared 510(K)
K
16
2110
CORGRIP NG/NI Tube Retention System
2
Cleared 510(K)
K
16
0787
Gabriel Feeding Tube with Balloon, Magnetically Guided Feeding Tube w/Balloon, Gabriel Feeding Tube with Balloon, Preassembled with Stylet
2
Cleared 510(K)
K
15
2246
Aquarius Stoma Measuring Device
2
Cleared 510(K)
K
15
3506
Qora AIM Stool Management Kit, Qora Aeon Stool Management Kit, Qora Arida Stool Management Kit
2
Cleared 510(K)
K
16
0654
GastriSail Gastric Positioning System 40 Fr/CH (13.3mm)
2
Cleared 510(K)
K
15
3461
Guide wire for Edi Catheter 6 Fr, Guide wire for Edi Catheter 8 Fr, 100 cm, Guide wire for Edi Catheter 8 Fr, 125 cm
2
Cleared 510(K)
K
14
0310
Peristeen Anal Irrigation System
2
Cleared 510(K)
K
15
0350
Flexi-Seal Signal Fecal Management System
2
Cleared 510(K)
K
14
2548
MIDSLEEVE
2
Cleared 510(K)
K
14
2327
smARTrack Feeding Tube System
2
Cleared 510(K)
K
14
2971
AMT Bridle - Nasal Tube Retention System
2
Cleared 510(K)
K
14
3088
GastriSail Gastric Positioning System
2
Cleared 510(K)
K
14
2816
AbbVie J
2
Cleared 510(K)
K
14
2792
AbbVie NJ
2
Cleared 510(K)
K
14
2793
AbbVie PEG
2
Cleared 510(K)
K
14
3378
AQUARIUS Gastrostomy Replacement Tube
2
Cleared 510(K)
K
13
3334
VERITRACT ENTERAL FEEDING TUBE SYSTEM
2
Cleared 510(K)
K
14
1631
AQUARIUS EXTENSION FEEDING SET
2
Cleared 510(K)
K
13
3077
GENERICA MEDICAL ENTERNAL DELIVERY; PUMP BAG SET, PUMP SPIKE SET, GRAVITY BAG SET
2
Cleared 510(K)
K
13
3465
CONSURE STOOL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
13
3087
ABBVIE PEG
2
Cleared 510(K)
K
13
3129
ABBVIE NJ
2
Cleared 510(K)
K
13
3096
ABB VIE J
2
Cleared 510(K)
K
13
1183
MED-RX ORAL/ENTERAL SYRINGE
2
Cleared 510(K)
K
13
2686
AQUARIUS LOW PROFILE GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
13
3251
BARD DIGNISHIELD STOOL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
12
3555
KANGAROO FEEDING TUBES WITH IRIS TECHNOLOGY
2
Cleared 510(K)
K
13
3599
CORGRIP
2
Cleared 510(K)
K
13
2424
METRIXCARE
2
Cleared 510(K)
K
13
3881
MACY CATHETER
2
Cleared 510(K)
K
13
0674
ENTUIT THRIVE LP BALLOON RETENTION GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
13
0611
ENTUIT THRIVE BALLOON RETENTION GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
13
1052
TUBECLEAR MODEL 101 (WITH NEW CLEARING STEM NE AND G MODELS)
2
Cleared 510(K)
K
13
1532
ELECTROMAGNETIC TRANSMITTING STYLET
2
Cleared 510(K)
K
12
2653
MIC-KEY SF LOW PROFILE GASTROSTOMY TUBE AND ACCESSORIES
2
Cleared 510(K)
K
12
3716
AMT LOW-PROFILE TRANSGASTRIC-JEJUNAL FEEDING TUBE KIT
2
Cleared 510(K)
K
12
3804
INSTAFLO BOWEL CATHETER SYSTEM KIT
2
Cleared 510(K)
K
13
0483
BOEHRINGER GASTRIC SIZING TUBE
2
Cleared 510(K)
K
12
3659
TUBE-CLEAR, CONTROL BOX (COMPONENT OF TUBECLEAR), CLEARING STEM (COMPONENT OF TUBECLEAR)
2
Cleared 510(K)
K
12
2030
LOW PROFILE GASTROSTOMY FEEDING TUBE OR GASTROTOMEY BUTTON
2
Cleared 510(K)
K
12
1571
TUBECLEAR
2
Cleared 510(K)
K
11
2860
PERISTEEN ANAL IRRIGATION SYSTEM, PERISTEEN ANAL IRRIGATION ACCESSORY UNIT, PERISTEEN ANAL IRRIGATION RECTAL CATHETER
2
Cleared 510(K)
K
11
2511
DOBBHOFF DUAL PORT FEEDING TUBE
2
Cleared 510(K)
K
11
2342
FLEXI-SEAL SIGNAL FECAL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
11
3719
SAFETY SCREW CONNECTOR
2
Cleared 510(K)
K
12
0182
NEOMED GASTROINTESTINAL TUBE AND ACCESSORIES
2
Cleared 510(K)
K
11
2863
ENTERAL ADMINISTRATION SET WITH SOLUTION CONTAINER, ENTERAL ADMINISTRATION SET, ENTERAL EXTENSION SET WITH MINITUBE CONN
2
Cleared 510(K)
K
11
2268
CODAN SAFEFEED ENTERAL FEEDING RESERVOIR
2
Cleared 510(K)
K
12
0272
AMERITUS MEDICAL ENTERAL FEEDING EXTENSION SET
2
Cleared 510(K)
K
11
3351
CORTRAK ENTERAL ACCESS DEVICE
2
Cleared 510(K)
K
10
2712
MED GRAVITY SET, IMED PUMP SET
2
Cleared 510(K)
K
10
2741
ENTERAL FEEDING BAG AND SETS
2
Cleared 510(K)
K
11
0804
AMT G-J TUBE
2
Cleared 510(K)
K
11
2434
BD ORAL/ENTERAL SYRINGE WITH BD UNIVIA CONNECTION
2
Cleared 510(K)
K
11
0005
SYNCRO - BLUE TUBE, THE MAGNETICALLY GUIDED ENTERAL FEEDING TUBE- 8FR TUBE
2
Cleared 510(K)
K
11
0529
ENDOFLIP GASTRIC TUBE
2
Cleared 510(K)
K
10
3254
PERISTEEN ANAL IRRIGATION SYSTEM, IRRIGATION ACCESSORY UNIT, IRRIGATION RECTAL CATHETER, SYSTEM STRAP, IRRIGATION TUBE
2
Cleared 510(K)
K
10
2572
IYUNNI 3ID SUPRAPUBIC CYSTOSTOMY TUBE KIT
2
Cleared 510(K)
K
10
3109
PONSKY* NON-BALLOON REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
10
2391
BARD DIGNISHIELD STOOL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
10
2548
FOOTPRINT MEDICAL POLYURETHANE FEEDING TUBE
2
Cleared 510(K)
K
10
1199
GUIDE WIRE FOR EDI CATHETER, 8FR,125CM,5 EACH,GUIDE WIRE FOR EDI CATHETER, 8FR,125CM,5 EACH,GUIDE WIRE FOR EDI CATHETER,
2
Cleared 510(K)
K
10
0288
NEOMED ENTERAL ONLY EXTENSION SET
2
Cleared 510(K)
K
10
0366
MEDICINA ENTERAL FEEDING TUBES AND ACCESSORIES MODEL MGX/YY
2
Cleared 510(K)
K
10
0365
FARRELL VALVE WITH CORFLO ANTI-IV CONNECTORS MODEL 20-4300AIV
2
Cleared 510(K)
K
09
2628
ENTERAL FEEDING TUBE AND ACCESSORIES, FEEDING TUBE EXTENSION SET
2
Cleared 510(K)
K
10
0273
INSTAFLO BOWEL CATHETER SYSTEM KIT
2
Cleared 510(K)
K
10
0173
IYUNNI 3ID TRI-FUNNEL FEEDING TUBE KIT
2
Cleared 510(K)
K
09
3653
URESIL GASTROSTOMY CATHETER KIT , MODEL GCL-630HBK
2
Cleared 510(K)
K
08
3770
COLOPLAST PERISTEEN ANAL IRRIGATION (PAI) SYSTEM
2
Cleared 510(K)
K
09
2418
ENTRACARE GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
09
2049
IYUNNI 3ID TRI-FUNNEL GASTROSTOMY TUBE KIT
2
Cleared 510(K)
K
09
1637
CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
2
Cleared 510(K)
K
09
1759
SINGLE USE SPLINTING TUBE, MODELS ST-Y0002-S, ST-Y0002-H, ST-Y0003-S AND ST-Y0003-H
2
Cleared 510(K)
K
08
3685
ENDOVIVE LOW PROFILE REPLACEMENT GASTROSTOMY TUBE, MODEL 82XX, 8283, 8284, 8285
2
Cleared 510(K)
K
09
0559
FOOTPRINT MEDICAL SILICONE FEEDING TUBE
2
Cleared 510(K)
K
08
3684
ENDO VIVE STANDARD REPLACEMENT GASTROSTOMY TUBE, MODEL 82XX
2
Cleared 510(K)
K
08
3153
ACTIFLO INDWELLING BOWEL CATHETER SYSTEM KIT, MODELS: 32004, 32005, 32006, 32007
2
Cleared 510(K)
K
08
2710
SAFECHILD ENTERAL FEEDING TUBE AND ACCESSORIES AND FEEDING TUBE EXTENSION SET
2
Cleared 510(K)
K
08
2863
DYNAREX ENTERAL DELIVERY PUMP SET WITH SPIKE (1000ML), DYNAREX ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE (1000ML)
2
Cleared 510(K)
K
08
1739
2-PORT THROUGH-THE-PEG (TTP) JEJUNOSTOMY TUBE KIT
2
Cleared 510(K)
K
08
2654
ENTERAL ONLY EXTENSION SET
2
Cleared 510(K)
K
08
1725
ENTERAL PUMP SET, MODEL 20-1010
2
Cleared 510(K)
K
08
2241
THE DALE ACE CONNECTOR (ACCESS CONTROLLER FOR ENTERAL), MODEL H84104751
2
Cleared 510(K)
K
08
0679
MODIFICATION TO CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
2
Cleared 510(K)
K
07
3598
BARD DIGNICARE STOOL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
08
0328
MPS ACACIA ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
07
3034
AMT INITIAL PLACEMENT GI KIT (E2418) AND AMT DILATOR SET (E2419)
2
Cleared 510(K)
K
08
0340
COMPAT DUALFLO ENTERAL DELIVERY PUMP SET WITH SPIKERIGHT PIERCING SPIKE AND 1000 ML WAER BAG
2
Cleared 510(K)
K
07
2652
ENTERAL FEEDING SPIKE ADAPTER
2
Cleared 510(K)
K
07
2756
NON-IV ADAPTER FOR INFANT NG TUBE
2
Cleared 510(K)
K
07
2476
THROUGH-THE-PEG (TTP) JEJUNOSTOMY TUBE KIT
2
Cleared 510(K)
K
07
2550
SIGHTSURE OPERATIONAL INDICATOR, MODEL SS301
2
Cleared 510(K)
K
07
1579
PEF TUBE
2
Cleared 510(K)
K
07
2787
GABRIEL BLUE TUBE MAGNETICALLY GUIDED ENTERAL FEEDING TUBE, MODEL GFT-111
2
Cleared 510(K)
K
07
1764
REALIZE GASTRIC CALIBRATION TUBE, MODELS GCT180, GCT360
2
Cleared 510(K)
K
07
0449
LUMILOC (TM) SAFETY INTRODUCER NEEDLE
2
Cleared 510(K)
K
07
0124
GASTROSTOMY REPLACEMENT TUBE, MODEL 253
2
Cleared 510(K)
K
06
3061
CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
2
Cleared 510(K)
K
06
3118
BARD BALLOON DILATION KIT WITH TRIFUNNEL GASTROSTOMY TUBE
2
Cleared 510(K)
K
06
1432
HOSPIRA ENTERAL FEEDING SET, MODEL 20640
2
Cleared 510(K)
K
06
1021
ENTAKE STANDARD AND SAFETY PEG SYSTEM
2
Cleared 510(K)
K
05
2903
PEDIATRIC FEEDING TUBE
2
Cleared 510(K)
K
05
1206
Y2K2 ENTERNAL TUBE FLUID FILTER
2
Cleared 510(K)
K
05
1551
SMALL INTESTINAL VIDEOSCOPE SYSTEM
2
Cleared 510(K)
K
04
2431
PROCON2
2
Cleared 510(K)
K
04
3203
WILSON-COOK ENTERAL FEEDING TUBE, TIGER TUBE ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
04
3044
ANTI-I.V. ENTERAL FEEDING SYSTEM
2
Cleared 510(K)
K
04
2112
INFANT FEEDING TUBE
2
Cleared 510(K)
K
04
1987
CORTRAK
2
Cleared 510(K)
K
04
3258
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER, PART NO. T4634-02
2
Cleared 510(K)
K
04
3114
KIMBERLY-CLARK MIC-KEY LOW PROFILE GASTROSTOMY TUBE
2
Cleared 510(K)
K
04
3027
MONARCH, TRANSSHAPING GASTROSTOMY TUBE, MODEL 9-XX20
2
Cleared 510(K)
K
04
2572
KENDALL CO2NFIRM NOW CO2 DETECTOR
2
Cleared 510(K)
K
04
2300
AMT INTRODUCER: MINI BUTTON DELIVERY SYSTEM
2
Cleared 510(K)
K
04
1034
SKIN LEVEL GASTROSTOMY TUBE KIT (ECSL)
2
Cleared 510(K)
K
03
0413
Y2K2 ENTERNAL FEEDING MANAGER
2
Cleared 510(K)
K
03
2734
CONVATEC FECAL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
03
0784
NASOGASTRIC BRIDLE SYSTEM WITH MAGNETIC RETRIEVAL
2
Cleared 510(K)
K
03
1492
MOSSMED DUAL INTERMITTENT ASPIRATOR
2
Cleared 510(K)
K
03
3562
FASTRAC GASTRIC ACCESS PORT KIT
2
Cleared 510(K)
K
03
0841
COOK GASTRIC SIZING BALLOON CATHETER
2
Cleared 510(K)
K
02
2558
NGT
2
Cleared 510(K)
K
03
1538
ENDOVIVE INITIAL PLACEMENT PEG KIT, DIRECT PEJ KIT, AND PEG SAFETY KIT
2
Cleared 510(K)
K
03
0855
MODIFICATION TO ENDOVIVE INITIAL PLACEMENT PEG KIT, DIRECT PEJ KIT, PEG SAFETY KIT
2
Cleared 510(K)
K
02
2112
FORTUNE ALL SILICONE STOMACH (GASTRIC) TUBES, MODEL 2020
2
Cleared 510(K)
K
02
3344
INDWELLING FECAL MANAGEMENT SYSTEM-NON-STERILE
2
Cleared 510(K)
K
02
2648
ENDOVIVE INITIAL PLACEMENT DIRECT PEJ KIT, MODELS 6520 & 6521
2
Cleared 510(K)
K
02
1493
ANDERSEN NASOGASTRIC TUBE WITH STYLET, MODELS AN 11S, 13S, 14S & 18S
2
Cleared 510(K)
K
02
0120
ENDOVIVE INITIAL PLACEMENT DIRECT PEJ KIT, ENDOVIVE STANDARD PROFILE BALLOON REPLACEMENT, MODELS 6520, 6521, 6220
2
Cleared 510(K)
K
02
1991
MAGNAFLOW MAGNETICALLY GUIDED ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
02
0005
INFANT FEEDING TUBES
2
Cleared 510(K)
K
01
4297
ENDOVIVE INITIAL PLACEMENT GASTROSTOMY KIT; ENDOVIVE LOW PROFILE BUTTON REPLACEMENT GASTROSTOMY TUBE; SECURI-T INITIAL P
2
Cleared 510(K)
K
02
1034
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
2
Cleared 510(K)
K
02
0985
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
2
Cleared 510(K)
K
02
0379
PPD BALLOON DILATATION CATHETER
2
Cleared 510(K)
K
01
2113
INDWELLING FECAL MANAGEMENT SYSTEM
2
Cleared 510(K)
K
01
0798
RUSCH CANTOR TUBE
2
Cleared 510(K)
K
01
0797
RUSCH MILLER-ABBOTT TUBE
2
Cleared 510(K)
K
01
2147
DEVICE MODIFICATION OF ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE
2
Cleared 510(K)
K
01
3162
14F X 24CM ASH SPLIT-CATH,14F X 28CM ASH SPLIT-CATH, 14F X 32CM ASH SPLIT-CATH, 14FX36CM ASH SPLIT-CATH, 14F X 40CM ASH
2
Cleared 510(K)
K
01
3144
DUAL PORT WIZARD LOW PROFILE REPLACEMENT GASTROSTOMY DEVICE; DUAL PORT WIZARD FEEDING/DECOMPRESSION TUBE, MODEL 00220W
2
Cleared 510(K)
K
01
1341
LH400 YES-SET Y-PORT ENTERAL SPIKE PUMP SET
2
Cleared 510(K)
K
01
1343
LH 500 ENTERAL FEEDING GRAVITY BAG SET
2
Cleared 510(K)
K
01
1340
LH 450 ENTERAL FEEDING BAG PUMP SET W/INTEGRATED Y-PORT
2
Cleared 510(K)
K
01
2476
MONARCH, TRANSSHAPING GASTROSTOMY TUBE MODEL 9-2010
2
Cleared 510(K)
K
01
1467
ROSS EMBRACE PUMP SET
2
Cleared 510(K)
K
00
2838
GASTRIC SUCTION AND DRAINAGE CATHETER
2
Cleared 510(K)
K
01
1077
ANDERSEN INTESTINAL TUBE, MILLER-ABBOTT TYPE (AN 22)
2
Cleared 510(K)
K
00
1916
COMPAT REPLACEMENT GASTROSTOMY TUBE KIT, MODEL 0974XX
2
Cleared 510(K)
K
99
0365
GASTRIC LAVAGE VALVE
2
Cleared 510(K)
K
99
3358
SIGHTSURE OPERATION INDICATOR, MODEL SS301
2
Cleared 510(K)
K
99
4300
NASOGASTRIC TUBE HOLDER, MODEL 160
2
Cleared 510(K)
K
99
2719
AMSURE ENTERAL DELIVERY PUMP SET WITH SPIKE
2
Cleared 510(K)
K
99
3296
TRIP TONOMETRY CATHETER, 14F
2
Cleared 510(K)
K
99
1918
NUTRISAFE EXTENSION TUBE
2
Cleared 510(K)
K
99
3138
BALLARD MIC-KEY G LOW PROFILE GASTROSTOMY REPLACEMENT KIT
2
Cleared 510(K)
K
99
1375
BARD BALLOON INFLATION SYSTEM
2
Cleared 510(K)
K
99
2494
FLEXIFLO ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
99
2181
TRIP TONOMETRY CATHETER, 8F
2
Cleared 510(K)
K
99
1668
COMPAT JEJUNOSTOMY TUBE KIT, MODEL 088OXX (XX=16,14, OR 12)
2
Cleared 510(K)
K
99
0863
MODIFICATION TO FLEXFLO POLYG GASTROSTOMY TUBE
2
Cleared 510(K)
K
99
0389
MOSS GASTROSTOMY TUBE
2
Cleared 510(K)
K
98
4628
MODIFICATION OF MOSS P.E.G. TRAY
2
Cleared 510(K)
K
98
3476
BIONAVIGATION SYSTEM FOR PLACEMENT OF ENTERAL FEEDING TUBES
2
Cleared 510(K)
K
98
4310
MOSS TUBES, INC, ALL SILICONE GASTROSTOMY TUBE
2
Cleared 510(K)
K
99
0127
CORFLO CUBBY LOW PROFILE GASTROSTOMY DEVICE (LPGD)
2
Cleared 510(K)
K
98
2500
CHAIT CECOSTOMY CATHETER
2
Cleared 510(K)
K
98
3366
TRIP TONOMETRY CATHETER, 16F
2
Cleared 510(K)
K
98
1323
COMPAT MINI-G REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
98
2894
MIC-KEY GLOW PROFILE GASTROSTOMY REPLACEMENT KIT
2
Cleared 510(K)
K
97
1434
A.M.T. G-TUBE BALLOON REPLACEMENT GASTROSTOMY FEEDING DEVICE
2
Cleared 510(K)
K
98
1203
RUSCH BLAKEMORE 3 LUMEN, STERILE
2
Cleared 510(K)
K
97
3892
RUSCH BLAKEMORE TUBE - 4 LUMEN (MINNESOTA TYPE)
2
Cleared 510(K)
K
98
0305
AMT BUTTON REPLACEMENT GASTROSTOMY DEVICE
2
Cleared 510(K)
K
97
4806
VYGON NEO-SUMP
2
Cleared 510(K)
K
97
3409
KANGAROO ENTERAL FEEDING EXTENSION SET FOR SYRINGE PUMPS
2
Cleared 510(K)
K
97
2478
PRE-LOADED REPLACEMENT G-TUBES AND ACCESSORIES
2
Cleared 510(K)
K
97
2102
RADIUS PUSH OVER THE GUIDE WIRE PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
2
Cleared 510(K)
K
97
2025
RADIUS PULL PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
2
Cleared 510(K)
K
97
1901
RADIUS LOW PROFILE GASTROSTOMY TUBE KIT
2
Cleared 510(K)
K
97
3891
LAPAROSCOPIC GASTROSTOMY KIT
2
Cleared 510(K)
K
97
3893
AMT BALLOON STOMA MEASURING DEVICES, AMT BALLOON MEASURING DEVICE, AMT BALLOON MEASURING DEVICE WITH STOP VALVE, AMY BAE
2
Cleared 510(K)
K
97
1757
LOW PROFILE FEEDING SET ACCESSORY
2
Cleared 510(K)
K
96
2554
FLEXIFLO LOW-PROFILE BALLOON GASTROSTOMY TUBE
2
Cleared 510(K)
K
97
0849
ENTERAL NUTRITION 1000 ML/500ML
2
Cleared 510(K)
K
97
0178
CLOG ZAPPER ENTERAL FEEDING TUBE DECLOGGING SYSTEM
2
Cleared 510(K)
K
96
4920
RPI DUAL PORT IRRIGATION ADAPTER
2
Cleared 510(K)
K
97
1230
SHERWOOD MEDICAL COMPANY , KANGAROO, ENTRISTAR, PERCUTANEOUS GASTROSTOMY KIT
2
Cleared 510(K)
K
97
0890
#ES-32 SUCTION CATHETER 32 FR.
2
Cleared 510(K)
K
96
5087
COMPAT GASTROSTOMY/JEJUNOSTOMY FEEDING TUBE KIT(088000)
2
Cleared 510(K)
K
95
0017
FLEXIFLO FLOCATOR SMALL BOWEL FEEDING SYSTEM
2
Cleared 510(K)
K
96
1664
COMPAT NASOJEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
96
3113
FLEXIFLO POLYG GASTOSTOMY TUBE
2
Cleared 510(K)
K
96
1345
DOMED PERCUTANEOUS ENDOSCOPIC GASTROSTOMY(P.E.G.) FEEDING TUBE
2
Cleared 510(K)
K
96
2375
MICROVASIVE BALLOON GASTROSTOMY TUBE KIT
2
Cleared 510(K)
K
93
5512
CORPAK REPLACEMENT GASTROSTOMY DEVICE STOMACORE
2
Cleared 510(K)
K
96
1884
CATH CADDIE
2
Cleared 510(K)
K
95
5181
U.S. ENDOSCOPY GROUP, INC. BALLOON REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
95
5248
U.S. ENDOSCOPY PULL PEG KIT & U.S. ENDOSCOPY GUIDEWIRE PEG KIT
2
Cleared 510(K)
K
96
0677
KANGAROO JEJUNAL FEEDING SYSTEM
2
Cleared 510(K)
K
96
0632
KANGAROO FEEDING TUBE PLACMENT STYLET
2
Cleared 510(K)
K
96
0415
WILSON-COOK BALLOON INFLATION DEVICE
2
Cleared 510(K)
K
96
0177
P.E.G. PATIENT CARE KIT
2
Cleared 510(K)
K
95
4879
PERCUTANEOUS REPLACEMENT GASTROSTOMY FEEDING CATHETER TRAY (MODIFICATION)
2
Cleared 510(K)
K
95
4429
KANGAROO ENTRISTAR SKIN-LEVEL GASTROSTOMY KIT
2
Cleared 510(K)
K
95
4776
REPLACEMENT GASTROSTOMY FEEDING CATHETER TRAY
2
Cleared 510(K)
K
94
6249
BARD(R) JEJUNAL FEEDING/GASTRIC DECOMPRESSION TUBES
2
Cleared 510(K)
K
92
2567
LOW PROFILE CATHETER
2
Cleared 510(K)
K
94
5618
GASTROINTESTINAL TUBES & ACCESSORIES
2
Cleared 510(K)
K
94
1228
ENDOLUMINAL ACCESS TUBE
2
Cleared 510(K)
K
95
3375
NG SECURE
2
Cleared 510(K)
K
94
6140
PRG BUTTON
2
Cleared 510(K)
K
95
3232
HOLLISTER NASOGASTRIC TUBE ATTACHMENT DEVICE
2
Cleared 510(K)
K
92
3488
GASTRANIMAL PERCUTANEOUS REPLACEMENT GASTROOMY
2
Cleared 510(K)
K
93
1921
CORPAK GASTROSTOMY TUBE
2
Cleared 510(K)
K
95
1489
MRI'S ALL SILICONE GASTROSTOMY TUBE
2
Cleared 510(K)
K
93
2880
GRASSI GASTROJEJUNOSTOMY TUBE
2
Cleared 510(K)
K
92
4306
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY
2
Cleared 510(K)
K
94
5612
MIC NASOGASTRIC-GASTROJEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
94
3240
FLEXIFLO SIX ENTERAL NUTRITION PUMP SET
2
Cleared 510(K)
K
92
2217
FLEXIFLO NASOENTERIC FEEDING TUBE
2
Cleared 510(K)
K
94
5012
CATCO NUTRITIONAL CATHETER
2
Cleared 510(K)
K
94
0548
MIC PERCUTANEOUS ENDOSCOPIC JEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
92
1478
GUARDPORT
2
Cleared 510(K)
K
92
2216
FLEXIFLO TUBE PLACEMENT VERIFIER
2
Cleared 510(K)
K
94
3675
ENTERAL DELIVERY SETS WITH HYDRATION PORT
2
Cleared 510(K)
K
92
4850
VANSONNENBERG GASTROSTOMY CATHETER
2
Cleared 510(K)
K
94
3685
MIC DISPOSABLE SNARE
2
Cleared 510(K)
K
93
5633
NO-MES
2
Cleared 510(K)
K
92
3046
BIOLOGIC DT-1000 MACHINE
2
Cleared 510(K)
K
93
3842
KLEIN RECTAL TAMPNADE BALLOON
2
Cleared 510(K)
K
93
5198
GASTROENTEROLOGY AND UROLOGY GUIDEWIRE MODIFICATIONS
2
Cleared 510(K)
K
92
6581
MIC TRANSGASTRIC JEJUNAL TUBE
2
Cleared 510(K)
K
93
2295
NON-BALLOON REPLACEMENT GASTROSTOMY KIT
2
Cleared 510(K)
K
93
5045
BIOSEARCH LAPROSCOPIC GASTRONOMY CATHETER
2
Cleared 510(K)
K
92
0579
LOW PROFILE PASSPORT PUSH & PULL KITS & PEG TUBE
2
Cleared 510(K)
K
92
3002
ENTEROCLYSIS TUBE
2
Cleared 510(K)
K
92
5061
HELLER TRANSILLUMINATING STYLETTE
2
Cleared 510(K)
K
92
3168
DUAL PORT ENTERAL Y-ADAPTOR
2
Cleared 510(K)
K
93
2861
FLEXIFLO GASTROSTOMY KIT
2
Cleared 510(K)
K
92
5102
FLEXIFLO LAPAROSCOPIC JEJUNOSTOMY KIT
2
Cleared 510(K)
K
92
1680
E-Z PEG
2
Cleared 510(K)
K
92
5854
VYGON - ENTERAL FEEDING TUBE - POLYURETHANE
2
Cleared 510(K)
K
92
1652
MIC TRANSGASTRIC JEJUNAL FEEDING TUBE KIT
2
Cleared 510(K)
K
92
1370
MIC GASTRO-ENTEROSTOMY TUBE MODIFICATION
2
Cleared 510(K)
K
93
6168
WILSON-COOK BALLOON INFLATION DEVICE
2
Cleared 510(K)
K
93
4772
GASTRONOMY TUBE HOLDER
2
Cleared 510(K)
K
92
5261
NUTRICARE ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
92
4065
MIC PEG TUBE
2
Cleared 510(K)
K
92
2998
ENFUSE ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
92
0703
GASTROINTESTINAL FEEDING TUBE
2
Cleared 510(K)
K
92
2667
MIC LOW PROFILE GASTROSTOMY TUBE
2
Cleared 510(K)
K
93
0456
INTHERM SINGLE-STICK RADIALLY EXPANDING DILATOR
2
Cleared 510(K)
K
93
2855
HOLLISTER VERTICAL DRAIN/TUBE ATTACHMENT DEVICE
2
Cleared 510(K)
K
92
4996
FLEXIFLO 60 NASOJEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
92
4697
FLEXIFLO LAPAROSCOPIC GASTROSTOMY KIT
2
Cleared 510(K)
K
92
4308
GASTROPORT II
2
Cleared 510(K)
K
92
1853
4 SURE TM FEEDING TUBES
2
Cleared 510(K)
K
91
5841
BARD GAUDERER UNIVERSAL PERCUTANEOUS ENDOSCOPIC
2
Cleared 510(K)
K
92
3692
STOMA MEASURING DEVICE
2
Cleared 510(K)
K
92
0262
ONAT BALLOONED NASOGASTRIC TUBE
2
Cleared 510(K)
K
92
3983
PEG GUIDEWIRE SYSTEM GASTROSTOMY TUBE KIT
2
Cleared 510(K)
K
91
5837
NON-BALLOON REPLACEMENT GASTROSTOMY SYSTEM
2
Cleared 510(K)
K
92
3474
LOW PROFILE GASTROMSTOMY DEVICE
2
Cleared 510(K)
K
92
1127
PANDA NEEDLE CATHETER JEJUNOSTOMY KIT
2
Cleared 510(K)
K
92
0493
PEG PREP TRAY
2
Cleared 510(K)
K
92
2209
NASOGRASTRIC TUBBE HOLDER
2
Cleared 510(K)
K
92
1697
FLEXIFLO COMPANION ENTERAL PUMP SETS AND CONTAINER
2
Cleared 510(K)
K
91
5735
FLEXIFLO QUANTUM ENT. PUMP SETS AND ENT. NUT. CONT
2
Cleared 510(K)
K
92
0894
DECOMPRESSION TUBES
2
Cleared 510(K)
K
92
1026
PRESSURE GAUGE
2
Cleared 510(K)
K
91
5110
FLEXIFLO OVER-THE-GUIDEWIRE GASTROSTOMY KIT
2
Cleared 510(K)
K
91
4375
NON-WEIGHTED POLYURETHANE ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
91
3997
SAECG CARDIOGRAPH MODEL M1754A
2
Cleared 510(K)
K
91
3476
GI BLEEDER/OD SET
2
Cleared 510(K)
K
91
5171
LOPEZ VALVE TM II
2
Cleared 510(K)
K
91
3784
DOBBHOFF(R) SINGLE PASS PEG KIT
2
Cleared 510(K)
K
91
3786
FLEXIFLO OVER-THE-GUIDEWIRE GAST KIT W/CR-BAR BUMP
2
Cleared 510(K)
K
90
0623
ZIMMON ESOPHAGO-GASTRIC BALLOON TAMPONADE DEVICE
2
Cleared 510(K)
K
91
3603
FIBRETWINS
2
Cleared 510(K)
K
91
2047
WILSON-COOK RUSSELL GASTROSTOMY KIT
2
Cleared 510(K)
K
91
0382
FLEXIFLO ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
91
1897
GASPARAITIS ESOPHAGRAM CATHETER SET
2
Cleared 510(K)
K
91
0910
MOSS- ANCHOR SET
2
Cleared 510(K)
K
91
0912
MOSS NASAL TUBE MARK IV
2
Cleared 510(K)
K
91
0911
MOSS P.E.G. TRAY
2
Cleared 510(K)
K
91
0913
MOSS GASTROSTOMY TUBE
2
Cleared 510(K)
K
91
0332
FLEXIFLO SACKS-VINE GASTROSTOMY KITS
2
Cleared 510(K)
K
90
5164
TUBE DECLOGGER
2
Cleared 510(K)
K
90
2623
FLEXIFLO STOMATE EXTENSION TUBE
2
Cleared 510(K)
K
90
3662
PEEWEE REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
90
0464
MIC PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE
2
Cleared 510(K)
K
90
3579
FLEXIFLO STOMATE DECOMPRESSION TUBE
2
Cleared 510(K)
K
90
3325
FLEXIFLO (R) VERSA-PEG (TM) GASTROSTOMY KIT
2
Cleared 510(K)
K
90
2099
WILSON-COOK VARICES TAMPONADE BALLOON CUFF
2
Cleared 510(K)
K
89
5650
ENTERAL PUMP SET W/ENTERA-FLO SPIKE
2
Cleared 510(K)
K
89
5329
600ML AND 1200ML ENTERAL BAG ADM. SET FOR ENTERA
2
Cleared 510(K)
K
89
5142
ENTERAL PUMP SET WITH ENTERAL SPIKE
2
Cleared 510(K)
K
90
2641
RPI ENTERAL FEEDING BAG 1000ML AND 500ML
2
Cleared 510(K)
K
90
2684
MIC ANAL INCONTINENCE TUBE
2
Cleared 510(K)
K
90
1835
LAKE N/G FEEDING TUBE (WITH Y PORT CONNECTOR)
2
Cleared 510(K)
K
90
2729
R.P.I. GRAVITY SAFE FEEDING BAG
2
Cleared 510(K)
K
90
0624
DOBBHOFF(R) GASTROTRAC JEJUNAL FEEDING SYSTEM
2
Cleared 510(K)
K
90
0590
BIOSEARCH DOBBHOFF(R) GASTROTRAC JEJUNAL FEEDING
2
Cleared 510(K)
K
90
0563
DOBBHOFF(R) ENDOENTERIC GASTRIC DECOMPRESSION CATH
2
Cleared 510(K)
K
90
0324
DOBBHOFF WIRE GUIDED JEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
90
1023
GASTROINTESTINAL TUBES AND ACCESSORIES
2
Cleared 510(K)
K
90
1574
ACKRAD MPR DRAINAGE CATHETER SET
2
Cleared 510(K)
K
90
1683
IMPROVED BAKER TWIN-CUFF SUMP TUBE
2
Cleared 510(K)
K
90
1134
ENTERA-FLO REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
90
1753
600 OR 1200 ML. ENTERAL BAG ADMINISTRATION SET
2
Cleared 510(K)
K
90
1130
ENTERA-FLO FEEDING TUBE
2
Cleared 510(K)
K
90
0852
MAGNET RETRIEVAL CATHETER
2
Cleared 510(K)
K
89
5933
ENTERAL PUMP SETS FOR USE WITH ROSS FLEXIFLO-III
2
Cleared 510(K)
K
89
5919
ENTERAL BAG ADMINI. SETS FOR USE W/FLEXIFLO-III
2
Cleared 510(K)
K
89
5696
ENTERAL PUMP SET W/ENTERAL SPIKE FOR USE W/FEED PU
2
Cleared 510(K)
K
89
5330
600ML AND 1200ML ENTERAL BAG ADM. SET FOR FRENTA
2
Cleared 510(K)
K
89
5366
ENTERAL PUMP SET WITH ENTERA (TM)-FLO SPIKE
2
Cleared 510(K)
K
89
5246
FRENTA(R) DUO-SET
2
Cleared 510(K)
K
89
6210
GASTRIC SUMP TUBE
2
Cleared 510(K)
K
89
5706
TUBING ORGANIZER
2
Cleared 510(K)
K
89
5616
L.T.C. FEEDING TUBE
2
Cleared 510(K)
K
89
3888
HOLLISTER FEEDING TUBE ATTACHMENT DEVICE
2
Cleared 510(K)
K
89
3541
VINYL BAG W/GRAVITY ADMINISTRATION SET
2
Cleared 510(K)
K
89
3540
VINYL BAG W/PUMP ADMINISTRATION SET
2
Cleared 510(K)
K
89
4857
PEDI-TUBE(R) STYLET
2
Cleared 510(K)
K
88
5220
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
2
Cleared 510(K)
K
89
1371
GILSDORF PERCU. ENDO.-PEG & PERCU. FLOURO.-PFG
2
Cleared 510(K)
K
89
3209
ENTERA-FLO SPIKE SET
2
Cleared 510(K)
K
89
0093
PVC EMPTY SOLUTION CONTAINER ENTERAL PUMP SET
2
Cleared 510(K)
K
89
2439
KENDALL CURITY STOMACH TUBES
2
Cleared 510(K)
K
89
0424
ENTERAL FEEDING CONTAINER
2
Cleared 510(K)
K
89
0430
ENTAINER(TM) ENTERAL FEEDING CONTAINER
2
Cleared 510(K)
K
89
0151
ENTERAL BAG/SET
2
Cleared 510(K)
K
89
1109
PANDA(R) NEEDLE CATHETER JEJUNOSTOMY TUBE
2
Cleared 510(K)
K
89
0871
BARD MOSS(R) GASTROSTOMY TUBE
2
Cleared 510(K)
K
89
0870
BARD GASTROSTOMY FEEDING DEVICE
2
Cleared 510(K)
K
88
5339
FLOW THRU 16,18,20,22 FR REPLACE. GASTRO TUBE KIT
2
Cleared 510(K)
K
89
0552
CP&S GAVAGE CONSTAINER, DISPOSABLE
2
Cleared 510(K)
K
88
4127
LAKE N/G FEEDING TUBE
2
Cleared 510(K)
K
88
4275
FLEXIFLO INTRODUCER (DIRECT STICK) GASTROSTOMY KIT
2
Cleared 510(K)
K
88
4309
NH PEDIATRIC REPLACEMENT GASTROSTOMY KIT
2
Cleared 510(K)
K
88
4128
LAKE N/G EXTENSION SET
2
Cleared 510(K)
K
88
4439
GASTROSTOMY FEEDING DEVICE
2
Cleared 510(K)
K
88
3319
HILL NASOGASTRIC TUBE
2
Cleared 510(K)
K
88
2918
KIM NASO-INTESTINAL TUBE
2
Cleared 510(K)
K
88
2682
COMPAT ENTERAL DELIVERY SYSTEM
2
Cleared 510(K)
K
88
2867
CORPAK PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE
2
Cleared 510(K)
K
88
2218
COMPAT (R) ENTERAL DELIVERY SYSTEM
2
Cleared 510(K)
K
88
2089
MRM GASTROSTOMY BELT
2
Cleared 510(K)
K
88
3351
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
88
3336
GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
88
0767
MIC NEEDLE JEJUNOSTOMY TUBE KIT
2
Cleared 510(K)
K
88
1978
ENTERAL FEEDING TUBES
2
Cleared 510(K)
K
88
1162
ENTERA* ENTERAL FEEDING BAG
2
Cleared 510(K)
K
87
5232
INTRO-REDUCER (NASOGASTRIC TUBE)
2
Cleared 510(K)
K
88
1310
DENT SLEEVE MANOMETRIC CATHETER
2
Cleared 510(K)
K
87
4154
ELECATH(R) TRANSESOPHAGEAL PACING CATHETER
2
Cleared 510(K)
K
88
0768
MIC (SPECIFIC LINE) REPLACEMENT KIT
2
Cleared 510(K)
K
88
0201
REPLACEMENT SILICONE GASTROSTOMY TUBE KIT #87600
2
Cleared 510(K)
K
88
0051
ENTERAL BAG/SET
2
Cleared 510(K)
K
87
4936
MEDSURG PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TRAY
2
Cleared 510(K)
K
87
5171
J-CATH(TM)
2
Cleared 510(K)
K
87
4755
EFFNER FE-EX* OROGASTRIC
2
Cleared 510(K)
K
87
3360
ENTERON PERCUTAN. ENDOSCOPIC GASTROSTOMY TRAY-PEG
2
Cleared 510(K)
K
88
0232
NH REPLACEMENT GASTROSTOMY KIT
2
Cleared 510(K)
K
87
5126
MIC (SPECIFIC LINE) INSERTION KIT
2
Cleared 510(K)
K
87
1848
NUTRITION DELIVERY SETS FOR VM 05 AMBULA. PUMP
2
Cleared 510(K)
K
87
4393
ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
87
3343
ENTUBE-MEER AND MEER FEEDING TUBE BRIDLE SYSTEM
2
Cleared 510(K)
K
87
2921
MSS ENTERAL DELIVERY SET
2
Cleared 510(K)
K
87
3441
BAKER TWIN-CUFF INTESTINAL DECOMP/PLICATION TUBE
2
Cleared 510(K)
K
87
2771
LOW PROFILE GASTROSTOMY
2
Cleared 510(K)
K
87
2932
MOSS(R) MARK IV NASAL TUBES CAT.# 87168
2
Cleared 510(K)
K
87
2531
MIC MUSHROOM TIP GASTROSTOMY TUBE
2
Cleared 510(K)
K
87
1846
FLEXIFLO TOPTAINER TOP-FILL ENTERAL NUTRIT. SYSTEM
2
Cleared 510(K)
K
87
2096
INFANT FEEDING KIT/SET NASOGASTRIC FEEDING KIT
2
Cleared 510(K)
K
87
2097
INFANT FEEDING TUBE
2
Cleared 510(K)
K
87
1691
MODIFIED MULTI-LUMEN NASOGASTRIC TUBE
2
Cleared 510(K)
K
87
1528
ENTRIMIT GRAVITY FEEDING SET
2
Cleared 510(K)
K
87
1554
MOSS(R) GASTROSTOMY TUBE CAT #5-17719
2
Cleared 510(K)
K
87
1019
ENFUSE ENTERNAL ADMINISTRATION SET & PUMP SET
2
Cleared 510(K)
K
87
1003
ENTROSET-SW
2
Cleared 510(K)
K
87
0508
GASTROINTESTINAL TUBE
2
Cleared 510(K)
K
86
4683
NEONATAL FEEDING KIT
2
Cleared 510(K)
K
86
4364
WINDSOR SAFETY-TOP ENTERAL FEEDING BAG/BAG & SET
2
Cleared 510(K)
K
86
4218
PROCON
2
Cleared 510(K)
K
86
1323
REPLACEMENT GASTROSTOMY TUBE
2
Cleared 510(K)
K
86
1309
JEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
86
4182
ENTERAL ADMINISTRATION ADAPTERS
2
Cleared 510(K)
K
86
2855
CRAIG NASO-GASTRIC TUBE HOLDER
2
Cleared 510(K)
K
86
1599
T-FASTENER
2
Cleared 510(K)
K
86
2573
HOLLISTER DRAIN TUBE ATTACHMENT
2
Cleared 510(K)
K
86
2489
ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE
2
Cleared 510(K)
K
86
1494
EMPTY SOLUTION TRANSFER CONTAINER 1,500 ML
2
Cleared 510(K)
K
86
2091
MCGAW NUTRA-FEED EFS ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
86
1862
DIETO CONTAINER FOR ENTERAL NUTRITION
2
Cleared 510(K)
K
86
1427
ENTUBE TM, ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
86
1618
TRAVASORB FEEDING TUBES - (2L8014) AND (2L8024)
2
Cleared 510(K)
K
86
1090
NUTRI-CATH - FEEDING TUBE
2
Cleared 510(K)
K
86
1552
TOP-PORT ENTERAL FEEDING BAG AND PREATTACHED SETS
2
Cleared 510(K)
K
86
0818
ONE TIME ENTERAL FEEDING BAG
2
Cleared 510(K)
K
86
0991
SCLEROTHERAPY INJECTION CATHETER
2
Cleared 510(K)
K
85
5098
COMPAT ENTERAL DELIVERY SYSTEMS
2
Cleared 510(K)
K
85
5097
COMPAT ENTERAL DELIVERY SYSTEMS
2
Cleared 510(K)
K
86
0589
INFLATOR/DEFLATOR PISTON SYRINGE
2
Cleared 510(K)
K
86
1051
ISOLIFE DISPENSING SYSTEM
2
Cleared 510(K)
K
86
0285
XRO GASTRO-DUODENAL, DUAL FLOW TUBE, SALEM TYPE
2
Cleared 510(K)
K
86
0052
QWIK-CALL
2
Cleared 510(K)
K
86
0075
DYNAFEED ENTERAL PUMP FEED BAG
2
Cleared 510(K)
K
85
4616
ENTERAL FEEDING BAG
2
Cleared 510(K)
K
85
4660
THE MMG ENTERAL FEEDING ADMINISTRATION SET
2
Cleared 510(K)
K
85
5121
COLOSHIELD KIT
2
Cleared 510(K)
K
85
4215
DYNAFEED
2
Cleared 510(K)
K
85
3384
E-Z-EM GASTRIC LAVAGE CATHETER
2
Cleared 510(K)
K
85
3253
CORPAK FARRELL VALVE ENTERAL GASTRIC PRESSURE RELI
2
Cleared 510(K)
K
85
3353
88000 GASTROSTOMY-JEJUNAL FEEDING TUBE KIT
2
Cleared 510(K)
K
85
2552
COONS GASTROSTICK SYSTEM
2
Cleared 510(K)
K
85
2535
E-Z P.E.G. W/PERCUTANEOUS ENDOSCOPY GASTROSTOMY
2
Cleared 510(K)
K
85
3288
FEEDING UNITS & TUBES
2
Cleared 510(K)
K
85
1975
ENTERAL FEEDING BAG, 1000 ML, & TUBING SET
2
Cleared 510(K)
K
85
3309
P.A. ENTERAL FEEDING BAG 1100
2
Cleared 510(K)
K
85
2966
ENTERAL FEEDING CONTAINER
2
Cleared 510(K)
K
85
3197
MIC JEJUNAL FEEDING TUBE
2
Cleared 510(K)
K
85
2707
GASTRO-ENTEROSTOMY TUBE
2
Cleared 510(K)
K
85
2363
MIC GASTROSTOMY TUBE PERCUTANEOUS INSERTION KIT
2
Cleared 510(K)
K
85
2792
CORPAK ENTERAL SOL ADM PUMP SET W/ SCREW
2
Cleared 510(K)
K
85
1672
NYHUS/NELSON TUBE
2
Cleared 510(K)
K
85
0664
ENDO-TUBE
2
Cleared 510(K)
K
85
1671
GASTROINTESTINAL TUBE
2
Cleared 510(K)
K
85
1539
CHESEBROUGH-PONDS KANGAROO PUMP SET W/EASY-CAP CLO
2
Cleared 510(K)
K
85
1444
KEITH-A.R.V.
2
Cleared 510(K)
K
83
2170
MUFFLER GAS-AIR VENT UNIT
2
Cleared 510(K)
K
85
0182
IVAC KEOFEED II POLYURETHANE FEEDING TUBE
2
Cleared 510(K)
K
85
0134
ENTRON ENTERAL FEEDING BAG
2
Cleared 510(K)
K
84
3939
PEDIATRIC SIZE K-TUBE A OR B
2
Cleared 510(K)
K
84
3567
KANGAROO NASOGASTRIC FEEDING TUBE
2
Cleared 510(K)
K
84
4745
K-TUBE
2
Cleared 510(K)
K
84
4789
KANGAROO ACCESS II ENTERAL FEEDING CONTAINER
2
Cleared 510(K)
K
84
4203
ENTERNAL FEEDING TUBE SILICONE-EF401, 402 & 403
2
Cleared 510(K)
K
84
4175
ENTERNAL FEEDING TUBE-POLYURETHANE EF504
2
Cleared 510(K)
K
84
4174
FLEXIBLE STAINLESS STEEL STYLET FOR ENTERNAL FEEDI
2
Cleared 510(K)
K
84
2174
PERCUTANEOUS GASTROSTOMY TUBE
2
Cleared 510(K)
K
84
4222
BIOSEARCH GLASER PEG PERCUTANEOUS ENDOSCOPIC GASTR
2
Cleared 510(K)
K
84
3975
9 FRENCH 42LONG POLYURETHANE GRADUATED ENTERIC FE
2
Cleared 510(K)
K
84
2808
URITROL-M
2
Cleared 510(K)
K
84
3392
GAUDERER GASTROSTOMY BUTTON
2
Cleared 510(K)
K
84
3305
DAVOL GAUDERER-PONSKY PERCUTAN-ENDOSCOP
2
Cleared 510(K)
K
84
1986
PROTOMED/TOWIC NASOGASTRIC TUBE DRAINAGE BAG
2
Cleared 510(K)
K
84
2841
VIVONEX TUNG STEN TIP TUBE
2
Cleared 510(K)
K
84
2589
IVAC KEOFEED HYDROPHILIC FEEDING TUBE
2
Cleared 510(K)
K
84
2076
MIC GASTROSTOMY TUBE
2
Cleared 510(K)
K
84
1945
ENTERAL FEEDING BOTTLE
2
Cleared 510(K)
K
84
1349
ESOPHAGEAL TUBE
2
Cleared 510(K)
K
84
1428
JEJUNOSTOMY SET FOR TUBE FEEDING
2
Cleared 510(K)
K
84
1289
RECTAL IRRIGATION TUBE
2
Cleared 510(K)
K
84
0864
GORE-TEX CATHETER
2
Cleared 510(K)
K
84
1330
GASTROSTOMY FEEDING TUBE
2
Cleared 510(K)
K
84
0752
ENTEROCYSIS TUBE W/GUIDE WIRE & CONNECT
2
Cleared 510(K)
K
84
1014
WEIGHTED FEEDING TUBE W/PRE-INSERTED
2
Cleared 510(K)
K
84
1034
DEAVER T-DRAIN & CATTEL T-DRAIN
2
Cleared 510(K)
K
84
1039
CANTOR TUBE
2
Cleared 510(K)
K
84
1038
BLAKEMORE TUBE
2
Cleared 510(K)
K
84
1036
RECTAL BALLOON CATHETERS
2
Cleared 510(K)
K
84
1033
MILLER-ABBOTT TUBE
2
Cleared 510(K)
K
84
1035
ULTRA BAKER JEJUNOSTOMY TUBE
2
Cleared 510(K)
K
84
0916
DIETO CONTAINER FOR ENTERNAL NUTRIT
2
Cleared 510(K)
K
84
0656
ENTERNAL Y EXTENSION SET RECORDER
2
Cleared 510(K)
K
84
0936
NEEDLE CATHETER JEJUNOSTOMY REPAIR KIT
2
Cleared 510(K)
K
83
3687
DISPOS. ENTERIC FEEDING TUBES W/SAFE-T
2
Cleared 510(K)
K
83
4562
ENTERNAL FEEDING TUBE
2
Cleared 510(K)
K
84
0019
K-TUBE REPAIR KIT
2
Cleared 510(K)
K
83
4554
ETHOX WEIGHTED FEEDING TUBE
2
Cleared 510(K)
K
83
4268
ISLAMI GASTROINTESTINAL TUBE
2
Cleared 510(K)
K
83
4258
HODGE DECOMPRESSION TUBE
2
Cleared 510(K)
K
83
3947
SUPERIOR ENTERNAL FEEDING SYSTEM
2
Cleared 510(K)
K
83
2093
FEEDING GASTROSTOMY TUBE
2
Cleared 510(K)
K
83
3492
PERCUTANEOUS ENDOSCOPIC GASTROSCOPY
2
Cleared 510(K)
K
83
3621
ENTRI FLEX FEEDING TUBE
2
Cleared 510(K)
K
83
3591
FEEDING TUBE
2
Cleared 510(K)
K
83
3513
NEEDLE CATHETER JEJUNOSTOMY KIT
2
Cleared 510(K)
K
83
2859
FOAM HELMET - USE W/ESOPHAGEAL TAMPONA
2
Cleared 510(K)
K
83
3293
LEIDER FEEDING TUBE W/HYDROMER LUBR
2
Cleared 510(K)
K
83
2966
FLEXIFLO ENTERAL FEEDING TUBE
2
Cleared 510(K)
K
83
3054
GASTRIC SUMP TUBES
2
Cleared 510(K)
K
83
2927
GRAVITY ENTERAL FEEDING SET
2
Cleared 510(K)
K
83
2196
SHERIDAN/LEVI-A-SUMP
2
Cleared 510(K)
K
83
2672
FOUR LUMEN BLAKEMORE TUBE
2
Cleared 510(K)
K
83
2293
ENTERNAL FEEDING TUBE
2
Cleared 510(K)
K
83
1971
VIVONEX TUNGSTEN TIP TUBE-TWISTED WIRE
2
Cleared 510(K)
K
83
1968
VIVONEX TUNGSTEN TIP TUBE-BRAIDED
2
Cleared 510(K)
K
83
1969
VIVONEX TUNGSTEN TIP TUBE-WOUND
2
Cleared 510(K)
K
83
2501
ENEMA TUBE
2
Cleared 510(K)
K
83
1847
JEJUNOSTOMY KIT
2
Cleared 510(K)
K
83
1840
FEEDING TUBE PLACEMENT STYLET
2
Cleared 510(K)
K
83
1823
AXIOM FEEDING GASTRO TUBE
2
Cleared 510(K)
K
83
1631
GASTROSTOMY FEEDING SET
2
Cleared 510(K)
K
83
1328
NEONATAL NASOGASTRIC FEEDING TUBE-
2
Cleared 510(K)
K
83
1970
VIVONEX TUNGSTEN TIP TUBE-MONOFILA-
2
Cleared 510(K)
K
83
1974
STOMACH TUBE LEVIN TUBE
2
Cleared 510(K)
K
83
1868
DOBBHOFF FEEDING TUBE W/HYDROMER LUB
2
Cleared 510(K)
K
82
3475
BROOKS SCLEROTHERAPY CUFF
2
Cleared 510(K)
K
83
1009
CANTOR TUBE
2
Cleared 510(K)
K
83
0990
BLAKEMORE TUBE
2
Cleared 510(K)
K
83
0989
BAKER JEJUNOSTOMY TUBE
2
Cleared 510(K)
K
83
0998
MILLER-ABBOTT TUBE
2
Cleared 510(K)
K
83
0985
STOMACH TUBE
2
Cleared 510(K)
K
83
0987
LEVIN TUBE
2
Cleared 510(K)
K
83
0986
RECTAL TUBES
2
Cleared 510(K)
K
83
0794
ARGYLE MADEN SILICONE GASTROSTOMY TUBE
2
Cleared 510(K)
K
83
1167
ENTERAL PUMP SET
2
Cleared 510(K)
K
83
1168
ENTERAL DELIVERY SET
2
Cleared 510(K)
K
83
1169
TOP-FILL BAG
2
Cleared 510(K)
K
83
0965
ENTERAL SOLUTION ADMIN. PUMP SET
2
Cleared 510(K)
K
83
0710
ARGYLE SILICONE SALEM SUMP TUBE
2
Cleared 510(K)
K
83
0119
NEEDLE CATHETER JEJUNOSTOMY KIT
2
Cleared 510(K)
K
82
3195
GASTRIC LAVAGE KIT
2
Cleared 510(K)
K
82
2087
DIA SCOPE
2
Cleared 510(K)
K
82
3082
TRAVASORB NASOGASTRIC NASOINTESTINAL
2
Cleared 510(K)
K
82
2879
ENTERAL NUTRITION 1
2
Cleared 510(K)
K
82
2004
FACE SHIELDS
2
Cleared 510(K)
K
82
2875
PEDI-TUBE PEDIATRIC FEEDING TUBE
2
Cleared 510(K)
K
82
2565
NEEDLE CATHETER JEJUNOSTOMY KIT
2
Cleared 510(K)
K
82
2380
ROMBEAU GASTROSTOMY-JEJUNAL TUBE
2
Cleared 510(K)
K
82
2631
ARGYLE DUO-TUBE
2
Cleared 510(K)
K
82
2228
GASTRO VAGE SET FOR GASTRIC LAVAGE
2
Cleared 510(K)
K
82
2443
NASO-GARD NASOGASTRIC TUBE HOLDER
2
Cleared 510(K)
K
82
1825
CONPHAR SILICONE FEEDING TUBE
2
Cleared 510(K)
K
82
1906
CORPAK ENTERIC FEEDING TUBE W/GUIDE TIP
2
Cleared 510(K)
K
82
1409
CORPAK-ENTERAL FEEDING CONTAINER
2
Cleared 510(K)
K
82
1410
CORPAK-MONITOR ENTERAL FEEDING CONTAIN
2
Cleared 510(K)
K
82
1231
VIVONEX TUNGSTEN TIP TUBE PLACEMENT
2
Cleared 510(K)
K
82
1067
VIVONEX ACUTROL ENTERNAL FEEDING SYS
2
Cleared 510(K)
K
82
1036
ENTERNAL SOLUTION ADMIN. SET
2
Cleared 510(K)
K
81
3585
WATERS ILEOSTOMY VALVE
2
Cleared 510(K)
K
82
0420
AM. PH. STERILE FEEDING TUBE
2
Cleared 510(K)
K
82
0441
ARGYLE PVC FEEDING TUBE
2
Cleared 510(K)
K
82
0442
ARGYLE INDWELL FEEDING TUBE
2
Cleared 510(K)
K
82
0176
VYGON ENTERNAL NUTRITION TUBES
2
Cleared 510(K)
K
81
3526
FECAL SANITARY TUBE
2
Cleared 510(K)
K
81
3132
THE CHICAGO GULLET
2
Cleared 510(K)
K
81
3169
CELESTIN PULSION ESOPHOGEAL PROSTHESIS
2
Cleared 510(K)
K
81
2648
EHTOX GASTRIC LAVAGE KIT #2050 & #2070
2
Cleared 510(K)
K
81
2427
CARTMILL/BARRY FEEDING TUBE
2
Cleared 510(K)
K
81
2507
THE KEOFEED STOMACH TUBE
2
Cleared 510(K)
K
81
2102
O.N.A.T.
2
Cleared 510(K)
K
81
2279
ENTER-A1 ENTERIC FEEDING TUBE
2
Cleared 510(K)
K
81
1968
VIVONEX TUNGSTEN TIP
2
Cleared 510(K)
K
81
1683
ENTRI ENTERNAL FEEDING SET
2
Cleared 510(K)
K
81
1533
MGN FEEDING TUBE
2
Cleared 510(K)
K
81
1639
ETHIX FEEDING TUBES POLYURETHANE/RADIOP.
2
Cleared 510(K)
K
81
1061
AUTOMATED GASTRIC LAVAGE
2
Cleared 510(K)
K
81
0979
ARROW NEEDLE-CATHETER JEJUNOSTOMY KIT
2
Cleared 510(K)
K
81
0996
ENTERNAL PUMP SET W/INTEGRAL CONTAINER
2
Cleared 510(K)
K
81
0573
TUBE FEEDING SET
2
Cleared 510(K)
K
81
0854
KANGAROO NASOGASTRIC FEEDING TUBE
2
Cleared 510(K)
K
81
0250
TRAY, IRRIGATION
2
Cleared 510(K)
K
81
0392
OESOPHAGEAL THERAPY KIT
2
Cleared 510(K)
K
81
0499
PERCUTANEOUS GASTROINTESTINAL TUBE
2
Cleared 510(K)
K
81
0156
ARGYLE SALEM SUMP TUBE
2
Cleared 510(K)
K
80
2585
FEEDING TUBES IN SILICONE 5,6,8&10 SIZES
2
Cleared 510(K)
K
80
2482
KEOFEED (R) EASY-FILL ENTERIC FEED BAG
2
Cleared 510(K)
K
80
2300
VIVONEX JEJUNOSTOMY KIT
2
Cleared 510(K)
K
80
1558
ENTERIC FEEDING TUBE W/SEGM. FLEX. WT.
2
Cleared 510(K)
K
80
1511
NASO-GARD NASOGASTRIC TUBE HOLDER
2
Cleared 510(K)
K
80
1498
ENTRI NASOGASTRIC FEEDING TUBE
2
Cleared 510(K)
K
80
0918
MODIFIED FEEDING JEJUNOSTOMY TUBE
2
Cleared 510(K)
K
80
0815
ENTERAL & NASOGASTRIC SOL. ADMIN. SET
2
Cleared 510(K)
K
80
0955
TUBE FEEDING CONTAINER 1500 ML DISPOSE.
2
Cleared 510(K)
K
80
0508
STOMACH TUBES
2
Cleared 510(K)
K
80
0510
RECTAL & HARRIS FLUSH TUBES
2
Cleared 510(K)
K
80
0507
FEEDING TUBES
2
Cleared 510(K)
K
79
2597
RECTAL LEAKAGE INHIBITOR
2
Cleared 510(K)
K
79
2333
BAKER INTESTINAL TUBE, TWIN CUFF
2
Cleared 510(K)
K
79
1714
SURGIFEED
2
Cleared 510(K)
K
79
1758
CLINIFEEDING SYSTEM 1
2
Cleared 510(K)
K
79
1250
CONPHAR STOMACH TUBE-STERILE-X-RAY
2
Cleared 510(K)
K
79
1269
CONPHAR STOMACH TUBE-STERILE
2
Cleared 510(K)
K
79
1268
CONPHAR RECTAL TUBE-STERILE
2
Cleared 510(K)
K
79
1257
CONPHAR FEEDING TUBE-STERILE
2
Cleared 510(K)
K
79
0612
NUTRIFLOW NASOGASTRIC FEEDING TUBE
2
Cleared 510(K)
K
79
0387
FEEDING TUBE W/ LUBRICANT COATING
2
Cleared 510(K)
K
78
1230
GAVAGE ADMIN. SET
2
Cleared 510(K)
K
76
0945
SILASTIC PERCUTANEOUS GASTROINTEST. TUBE
2
Cleared 510(K)
K
76
0708
SILASTIC BRAND Q7-2091 GASTRIC SUMP TUBE
2
Cleared 510(K)
KNX
Collector, Urine, (And Accessories) For Indwelling Catheter
2
Product Code
KNY
Accessories, Catheter, G-U
2
Product Code
KNZ
Accessories, A-V Shunt
2
Product Code
KOB
Catheter, Suprapubic (And Accessories)
2
Product Code
KOC
Accessories, Blood Circuit, Hemodialysis
2
Product Code
KOD
Catheter, Urological
2
Product Code
KOE
Dilator, Urethral
2
Product Code
KPF
System, Dialysate Delivery, Semi-Automatic, Peritoneal
2
Product Code
KPH
Catheter, Rectal For Continent Ileostomy
1
Product Code
KPI
Stimulator, Electrical, Non-Implantable, For Incontinence
2
Product Code
KPL
Colonic Irrigation System
2
Product Code
KPM
Shunt, Peritoneal
2
Product Code
KPO
Dialysate Concentrate For Hemodialysis (Liquid Or Powder)
2
Product Code
KPP
Peritoneal Dialysate Filter
2
Product Code
KQQ
Tubing, Dialysate (And Connector)
2
Product Code
KQR
Detector, Air Or Foam
2
Product Code
KXM
System Accessories, Extracorporeal
2
Product Code
LBW
Set, Dialysis, Single Needle (Co-Axial Flow)
2
Product Code
LCG
Intestinal Splinting Tubes
2
Product Code
LFJ
Catheter, Subclavian
2
Product Code
LFK
Catheter, Femoral
2
Product Code
LIF
Dialyzer Reprocessing System
2
Product Code
LJH
System, Irrigation, Urological
2
Product Code
LKY
Device, External Penile Rigidity
2
Product Code
LLB
System, Blood, Extracorporeal And Accessories
2
Product Code
LNS
Lithotriptor, Extracorporeal Shock-Wave, Urological
2
Product Code
LQR
Dislodger, Stone, Biliary
2
Product Code
LRI
Ph Meter For Dialysis Hydrogen Ion Concentration
2
Product Code
MJC
Catheter, Urological (Antimicrobial) And Accessories
2
Product Code
MLW
Warmer, Peritoneal Dialysate
2
Product Code
MNG
External Urethral Occluder, Urinary Incontinence-Control, Female
1
Product Code
MNV
Strip, Dialysate Ph Indicator
2
Product Code
MON
System, Hemodialysis, Remote Accessories
1
Product Code
MPB
Catheter, Hemodialysis, Non-Implanted
2
Product Code
MQS
System, Hemodialysis, Access Recirculation Monitoring
2
Product Code
MSB
System And Accessories, Isolated Heart, Transport And Preservation
2
Product Code
MSD
Catheter, Hemodialysis, Implanted
2
Product Code
MSE
Hemodialyzer, Re-Use, Low Flux
2
Product Code
MSF
Hemodialyzer, Re-Use, High Flux
2
Product Code
MSY
Strip, Test, Reagent, Residuals For Dialysate, Disinfectant
2
Product Code
MSZ
Strip, Test, Reagent, Residuals For Dialysate
2
Product Code
NAM
Stimulator, Peripheral Nerve, Non-Implanted, For Pelvic Floor Dysfunction
2
Product Code
NDS
Media, Culture, Ex Vivo, Tissue And Cell
2
Product Code
NFK
Kit, Repair, Catheter, Hemodialysis
2
Product Code
NHV
System, Water Purification, General Medical Use
2
Product Code
NIE
Catheter, Hemodialysis, Triple Lumen, Non-Implanted
2
Product Code
NIF
Catheter, Hemodialysis, Triple Lumen, Implanted
2
Product Code
NML
Catheter, Biliary, Reprocessed
2
Product Code
NNE
Needle, Fistula, Reprocessed
2
Product Code
NNG
Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed
2
Product Code
NNW
Bag, Urine Collection, Leg, For External Use, Non-Sterile
1
Product Code
NNX
Device, Incontinence, Urosheath Type, Non-Sterile
1
Product Code
NNY
Sheath, Corrugated Rubber, For Non-Indwelling Catheter, Non-Sterile
1
Product Code
NNZ
System, Urine Drainage, Closed, For Non-Indwelling Catheter, Non-Sterile
1
Product Code
NOA
Device, Paste-On For Incontinence, Non-Sterile
1
Product Code
NOO
Clamp, Dialysis Arm
1
Product Code
NOY
Agents, Embolic, For Treatment Of Benign Prostatic Hyperplasia
2
Product Code
NQJ
Catheter, Hemodialysis, Non-Implanted, Ultrafiltration, For Peripheral Use
2
Product Code
NTZ
Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator
2
Product Code
NUB
Colonic Irrigation System, General Well Being
3
Product Code
NYU
Catheter, Hemodialysis, Implanted, Coated
2
Product Code
NWO
Kit, Catheter, Urinary (Exludes Hiv Testing)
2
Product Code
NWP
Suprapubic Cystostomy Catheter Kit
2
Product Code
NWQ
Kit, Catheter, External, Male (Excludes Hiv Testing)
2
Product Code
NWR
Kit, Catheter, Foley (Excludes Hiv Testing)
2
Product Code
NZU
Collector, Urine, Powered, Non Indwelling Catheter
1
Product Code
ODN
Ultrafiltration-Controlled Nocturnal Dialysate Delivery System
2
Product Code
ODX
Autonomous Extracorporeal Blood Leak Detector/Alarm
2
Product Code
OHR
Catheter Care Tray
2
Product Code
ONW
Hemodialysis System For Home Use
2
Product Code
ONY
Oral Removable Retainer For Weight Management
2
Product Code
PBP
Rectal Insert
2
Product Code
PCU
Pancreatic Stent, Covered, Metallic, Removable
2
Product Code
PEH
Hemodialysis Catheter Luer End Cap
2
Product Code
PEV
Dialysis Administration Kit
2
Product Code
PEW
Implantable Transprostatic Tissue Retractor System
2
Product Code
PFH
Venous Window Needle Guide
2
Product Code
PIA
Vibrator For Climax Control Of Premature Ejaculation
2
Product Code
PID
Esophageal Dilator Balloon With Or Without Electrode Sensors
2
Product Code
PIE
Esophageal Dilator With Balloon And Electrode Sensors
2
Product Code
PIF
Gastrointestinal Tubes With Enteral Specific Connectors
2
Product Code
QGC
Suprapubic Catheter Accessories
1
Product Code
PIH
Urethral Insert With Pump For Bladder Drainage
2
Product Code
PIN
Kidney Perfusion Kit
2
Product Code
PIO
Enteral Specific Transition Connectors
2
Product Code
PJH
Dynamic Rectal Control System
2
Product Code
PKI
Fully Subcutaneous Implanted Hemodialysis Catheter
2
Product Code
PLI
Gastrointestional Tube Holder
2
Product Code
PLQ
Enzyme Packed Cartridge
2
Product Code
PNB
Biliary Stent System For Benign Strictures
2
Product Code
PNG
Peritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling
2
Product Code
PNR
Enteral Syringes With Enteral Specific Connectors
2
Product Code
QFQ
Ingested, Transient, Space Occupying Device For Weight Management And/Or Weight Loss
2
Product Code
PPA
Bladder Irrigation Kit
2
Product Code
PPB
Foley Catheter Kit (Excludes Hiv Testing)
2
Product Code
PPC
Male External Catheterization Kit (Excludes Hiv Testing)
2
Product Code
PPD
Universal Drainage Tray
2
Product Code
PPF
Urinary Irrigation Kit
2
Product Code
PPG
Urinary Drainage Collection Kit
2
Product Code
PPH
Single Needle With Uni-Directional Pump Kit
2
Product Code
PPI
Hemodialysis Tray (Not A Start/Stop Kit)
2
Product Code
PPJ
Peritoneal Dialysis Administration Kit
2
Product Code
PPK
Peritoneal Dialysis Tubing Kit
2
Product Code
PPL
Single Needle (Co-Axial Flow) Dialysis Kit
2
Product Code
PPO
Multi-Lumen Hemodialysis Catheterization Kit
2
Product Code
PQE
Ostomy Care Kit
1
Product Code
PRM
Enteral Administration Kit (Adult & Pediatric)
2
Product Code
PRO
Anti-Regurgitation Blood Tubing Kit
2
Product Code
PRP
Balloon Gastrostomy Tube Kit
2
Product Code
PRQ
Esophageal Dilator Kit
2
Product Code
PRR
Feeding Tube Kit
2
Product Code
PRS
Gastric Colonic Catheter Irrigation Kit
2
Product Code
PRT
Gastric Irrigation And Aspiration Kit
2
Product Code
PRW
Gastrointestinal Tube Kit
2
Product Code
PRX
Gastrostomy Guide Wire Placement Kit
2
Product Code
PRY
Gastrostomy Jejunostomy Feeding Tube Kit
2
Product Code
PRZ
Gastrostomy Tube Kit
2
Product Code
PSA
Laparoscopic Jejunostomy Kit
2
Product Code
PSB
Nasogastric Feed Tube Kit
2
Product Code
PSC
Nasogastric-Gastrojejunal Kit
2
Product Code
PSD
Laparoscopic Gastrostomy Kit
2
Product Code
PSE
Needle Catheter Jejunostomy Kit
2
Product Code
PSF
Non-Balloon Replacement Gastrostomy System
2
Product Code
PSG
Percutaneous Endoscopic Gastrostomy Kit
2
Product Code
PSH
Percutaneous Replacement Gastrostomy Tube Kit
2
Product Code
PSJ
Rectal Dilator Kit
1
Product Code
PSK
Replacement Gastrostomy Feeding Catheter Tray
2
Product Code
PSX
Chlorine Meter
2
Product Code
PTK
Pediatric Esophageal Atresia Anastomosis Device
3
Product Code
PTT
Biliary Catheter For Irrigation And Contrast Injection, Exempt
2
Product Code
PTU
Catheter, Peritoneal, Long-Term Indwelling, Exempt
2
Product Code
PTV
Catheter, Peritoneal Dialysis, Single Use, Exempt
2
Product Code
PTW
System, Peritoneal, Automatic Delivery, Exempt
2
Product Code
QAJ
Cutaneous Electrode Stimulator For Urinary Incontinence
2
Product Code
QGD
Implanted Mechanical/Hydraulic Urinary Continence Device Surgical Accessories
1
Product Code
QGE
Biliary Stent, Drain, And Dilator Accessories
1
Product Code
QON
Implanted Electrical Device Intended For Treatment Of Fecal Incontinence
3
Product Code
QRC
Non-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation
2
Product Code
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 27 January 2023 at 11:04 pm
GU
/
therapeutic-devices
/
KNT
/
K872932
View Source
MOSS(R) MARK IV NASAL TUBES CAT.# 87168
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K872932
510(k) Type
Traditional
Applicant
MFG. AND RESEARCH, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
9/15/1987
Days to Decision
50 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
Cardiovascular Monitoring Devices
Diagnostic Devices
General Hospital and Personal Use Miscellaneous Devices
Miscellaneous
Monitoring Devices
Neurological Therapeutic Devices
Obstetrical and Gynecological Diagnostic Devices
Obstetrical and Gynecological Surgical Devices
Physical Medicine Therapeutic Devices
Prosthetic Devices
Surgical Devices
Therapeutic Devices
EZT
Pacemaker, Bladder
EZW
Stimulator, Electrical, Implantable, For Incontinence
EZY
Device, Incontinence, Mechanical/Hydraulic
FAH
Dilator, Urethral, Mechanical
BSS
Tube, Nasogastric
EXA
Selector, Size, Ostomy
EXB
Collector, Ostomy
EXD
Irrigator, Ostomy
EXE
Protector, Ostomy
EXF
Bag, Bile Collecting
EXG
Bag, Urine Collecting, Ureterostomy
EXH
Bag, Urinary, Ileostomy
EXI
Device, Paste-On For Incontinence, Sterile
EXJ
Device, Incontinence, Urosheath Type, Sterile
EXN
Support, Hernia
EYA
Stylet, Ureteral
EYB
Catheter, Ureteral, Gastro-Urology
EYC
Catheter, Upper Urinary Tract
EYI
Adaptor, Ureteral Catheter
EYJ
Holder, Ureteral Catheter
EYK
Connector, Ureteral Catheter
EYQ
Garment, Protective, For Incontinence
EYT
Sheath, Corrugated Rubber, For Nonindwelling Catheter, Sterile
EYZ
System, Urine Drainage, Closed, For Nonindwelling Catheter, Sterile
EZB
Stylet For Catheter, Gastro-Urology
EZC
Catheter, Coude
EZD
Catheter, Straight
EZK
Catheter, Retention Type
EZL
Catheter, Retention Type, Balloon
EZM
Dilator, Esophageal (Metal Olive) Gastro-Urology
EZN
Dilator, Catheter, Ureteral
EZQ
Pouch, Colostomy
EZR
Cement, Stomal Appliance, Ostomy
EZS
Appliance, Colostomy, Disposable
FAQ
Bag, Urine Collection, Leg, For External Use, Sterile
FAT
Bougie, Esophageal, And Gastrointestinal, Gastro-Urology
FAX
Bougie, Urological
FBM
Cannula And Trocar, Suprapubic, Non-Disposable
FBR
Urethrometer
FBW
Filiform And Filiform Follower
FBX
Sound, Urethral, Metal Or Plastic
FCB
Bag, Hemostatic
FCE
Enema Kit
FCM
Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
FCN
Urinary Drainage Collection Kit, For Indwelling Catheter
FEF
Tube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression
FEG
Tube, Double Lumen For Intestinal Decompression And/Or Intubation
FEW
Catheter, Malecot
FEX
Instrument, Catheter, Punch
FEZ
Catheter And Tube, Suprapubic
FFA
Tube, Drainage, Suprapubic
FFH
Collector, Urine, Pediatric, For Indwelling Catheter
FFP
Dilator, Rectal
FFW
String And Tubes, Gastrointestinal, To Locate Internal Bleeding
FGD
Catheter, Retention, Barium Enema With Bag
FGE
Stents, Drains And Dilators For The Biliary Ducts
FGF
Catheter, Ureteral Disposable (X-Ray)
FGH
Catheter, Double Lumen Female Urethrographic
FGI
Catheter, Urethrographic, Male
FHA
Clamp, Penile
FHS
Dialyzer, Single Coil
FHT
Set, Gavage, Infant, Sterile
FIA
Chair, Dialysis, Unpowered, Without Scales
FIB
Protector, Transducer, Dialysis
FID
Tubing, Dialysate
FIE
Needle, Fistula
FIF
Set, Dialysis, Single Needle With Uni-Directional Pump
FIG
Clamp, Tubing, Blood, Automatic
FIH
Pump, Infusion Or Syringe, Extra-Luminal
FII
System, Dialysate Delivery, Sealed
FIJ
System, Dialysate Delivery, Recirculating, Single Pass
FIK
System, Dialysate Delivery, Recirculating
FIL
System, Dialysate Delivery, Single Pass
FIN
Tank, Holding, Dialysis
FIP
Subsystem, Water Purification
FIQ
Cannula, A-V Shunt
FIR
Pump, Blood, Extra-Luminal
FIS
Flowmeter, Dialysate
FIW
Alarm, Pillow Pressure
FIZ
Meter, Conductivity, Non-Remote
FJA
Manometer, Water
FJB
Detector, Dialysate Level
FJC
Detector, Blood Level
FJD
Detector, Leak, Blood
FJF
Detector, Air Bubble
FJG
Dialyzer, Parallel Flow
FJH
Dialyzer, Disposable
FJI
Dialyzer, Capillary, Hollow Fiber
FJJ
Dialyzer, Twin Coil
FJK
Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
FJM
Guard, Shunt
FJN
Stabilizer, Shunt
FJO
Plier, Tube
FJP
Adaptor, Y
FJQ
Connector, Shunt
FJR
Forceps, Disconnect
FJS
Catheter, Peritoneal, Long-Term Indwelling
FJT
Intracatheter, Dialysis
FJW
Ring, Joint
FJX
Ring, Crimp
FJY
Plier, Crimp
FJZ
Declotting Tray, Kit (Including Contents)
FKA
Dilator, Vessel
FKB
Connector, Blood Tubing, Infusion T
FKC
Clamp, Cannula
FKD
Canister, Coil
FKE
Tie, Dialysis
FKF
Gun, Tie, Dialysis
FKG
Tray, Start/Stop (Including Contents), Dialysis
FKH
Solution-Test Standard-Conductivity, Dialysis
FKI
Set, Dialyzer Holder
FKJ
Filter, Blood, Dialysis
FKL
Insert, Pump, Blood
FKM
Adaptor, Fistula
FKN
Adaptor, Shunt
FKO
Catheter, Peritoneal Dialysis, Single Use
FKP
System, Dialysate Delivery, Single Patient
FKQ
System, Dialysate Delivery, Central Multiple Patient
FKR
Subsystem, Proportioning
FKT
System, Dialysate Delivery, Sorbent Regenerated
FKW
Tip, Vessel
FKX
System, Peritoneal, Automatic Delivery
FKY
Connector, Tubing, Dialysate
FLA
Monitor, Temperature, Dialysis
FLB
Meter, Conductivity, Induction, Remote Type
FLC
Station, Dialysis Control, Negative Pressure Type
FLD
Apparatus, Hemoperfusion, Sorbent
FOC
Bag, Urine Collection, Newborn
FON
Bag, Drainage, With Adhesive, Ostomy
FPD
Tube, Feeding
FRQ
Tube, Levine
GBL
Catheter, Ureteral, General & Plastic Surgery
GBM
Catheter, Urethral
GBT
Catheter, Rectal
GCA
Biliary Catheter For Stone Removal That May Also Allow For Irrigation And Contrast Injection
GDS
Bag, Stomal
KDH
Catheter (Gastric, Colonic, Etc.), Irrigation And Aspiration
KDI
Dialyzer, High Permeability With Or Without Sealed Dialysate System
KDJ
Set, Administration, For Peritoneal Dialysis, Disposable
KDK
Container, Transport, Kidney
KDL
Set, Perfusion, Kidney, Disposable
KDN
System, Perfusion, Kidney
KGC
Tube, Gastro-Enterostomy
KNQ
Dilator, Esophageal
KNR
Adapter, A-V Shunt Or Fistula
KNT
Tubes, Gastrointestinal (And Accessories)
K
22
0218
Siren SGT
K
22
0588
Avanos* CORTRAK* 2 Enteral Access System (EAS)
K
21
2444
Qora Stool Management Kit
K
21
2728
Standard Bougie, 38 Fr. and Hand Pump
K
21
0437
Standard Bougie, 38 Fr.
K
21
1072
Safety Trocar Cannula
K
20
2748
Enteral Feeding Catheter
K
20
3133
ENvizion Medical ENvue ENvizion Medical Enteral Feeding Tube
K
20
0646
TubeClear System
K
20
2539
Nutriglide(TM) Nasal Feeding Tube
K
20
1322
Entuit Nasal Jejunal Feeding Tube
K
19
1885
Standard Bougie
K
19
3325
Avantgarde Faecal Management Systems, Avantgarde Faecal Management System Replacement Pouches
K
19
0977
Navina Smart System, Navina Classic System
K
19
0084
McLean-Ring Enteral Feeding Tube Set
K
19
1387
ENvizion Medical ENVue SYSTEM, ENvizion Medical Enteral Feeding Tube
K
19
1340
CORTRAK* 2 Equilateral Enteral Access System
K
18
3336
Entuit PEG, Entuit PEGJ
K
18
3577
Medline Quick-Clear Wand
K
19
0114
Flexi-Seal PROTECT PLUS Fecal Management System (with ENFit Connector)
K
18
3508
Micro Transgastric-Jejunal Feeding Device
K
18
2804
Traditional Length GJ Feeding Device
K
18
2915
ENvizion Medical ENvue; ENvizion Medical Enteral Feeding Tube
K
18
2248
Aspire Venting Tube
K
18
0605
GastroFlush
K
18
0622
Kangaroo Gastrostomy Feeding Tube with ENFit Y-Port
K
18
0725
Aspire Introducer Needle
K
17
2556
TubeClear System
K
18
0026
Bowel Management Device, Bowel Management Irrigation Set
K
17
3955
Mic-Key* SF Over-the-Wire Stoma Measuring Device
K
17
3355
Gastric Sizing Balloon Catheter
K
16
2340
Stomach Tube
K
17
0319
Low Profile Non-Balloon Feeding Device
K
17
0487
Navina Classic System
K
16
0567
Barone Jejunostomy Catheter Set
K
16
0509
Tiger 2 Self-Advancing Nasal Jejunal Feeding Tube
K
16
3002
Kangaroo Feeding Tube with IRIS Technology
K
16
2906
Flexi-Seal PROTECT Fecal Management System
K
16
1413
Low Profile Balloon Feeding Device
K
16
3092
TubeClear Control Box and Clearing Stem
K
16
2110
CORGRIP NG/NI Tube Retention System
K
16
0787
Gabriel Feeding Tube with Balloon, Magnetically Guided Feeding Tube w/Balloon, Gabriel Feeding Tube with Balloon, Preassembled with Stylet
K
15
2246
Aquarius Stoma Measuring Device
K
15
3506
Qora AIM Stool Management Kit, Qora Aeon Stool Management Kit, Qora Arida Stool Management Kit
K
16
0654
GastriSail Gastric Positioning System 40 Fr/CH (13.3mm)
K
15
3461
Guide wire for Edi Catheter 6 Fr, Guide wire for Edi Catheter 8 Fr, 100 cm, Guide wire for Edi Catheter 8 Fr, 125 cm
K
14
0310
Peristeen Anal Irrigation System
K
15
0350
Flexi-Seal Signal Fecal Management System
K
14
2548
MIDSLEEVE
K
14
2327
smARTrack Feeding Tube System
K
14
2971
AMT Bridle - Nasal Tube Retention System
K
14
3088
GastriSail Gastric Positioning System
K
14
2816
AbbVie J
K
14
2792
AbbVie NJ
K
14
2793
AbbVie PEG
K
14
3378
AQUARIUS Gastrostomy Replacement Tube
K
13
3334
VERITRACT ENTERAL FEEDING TUBE SYSTEM
K
14
1631
AQUARIUS EXTENSION FEEDING SET
K
13
3077
GENERICA MEDICAL ENTERNAL DELIVERY; PUMP BAG SET, PUMP SPIKE SET, GRAVITY BAG SET
K
13
3465
CONSURE STOOL MANAGEMENT SYSTEM
K
13
3087
ABBVIE PEG
K
13
3129
ABBVIE NJ
K
13
3096
ABB VIE J
K
13
1183
MED-RX ORAL/ENTERAL SYRINGE
K
13
2686
AQUARIUS LOW PROFILE GASTROSTOMY FEEDING TUBE
K
13
3251
BARD DIGNISHIELD STOOL MANAGEMENT SYSTEM
K
12
3555
KANGAROO FEEDING TUBES WITH IRIS TECHNOLOGY
K
13
3599
CORGRIP
K
13
2424
METRIXCARE
K
13
3881
MACY CATHETER
K
13
0674
ENTUIT THRIVE LP BALLOON RETENTION GASTROSTOMY FEEDING TUBE
K
13
0611
ENTUIT THRIVE BALLOON RETENTION GASTROSTOMY FEEDING TUBE
K
13
1052
TUBECLEAR MODEL 101 (WITH NEW CLEARING STEM NE AND G MODELS)
K
13
1532
ELECTROMAGNETIC TRANSMITTING STYLET
K
12
2653
MIC-KEY SF LOW PROFILE GASTROSTOMY TUBE AND ACCESSORIES
K
12
3716
AMT LOW-PROFILE TRANSGASTRIC-JEJUNAL FEEDING TUBE KIT
K
12
3804
INSTAFLO BOWEL CATHETER SYSTEM KIT
K
13
0483
BOEHRINGER GASTRIC SIZING TUBE
K
12
3659
TUBE-CLEAR, CONTROL BOX (COMPONENT OF TUBECLEAR), CLEARING STEM (COMPONENT OF TUBECLEAR)
K
12
2030
LOW PROFILE GASTROSTOMY FEEDING TUBE OR GASTROTOMEY BUTTON
K
12
1571
TUBECLEAR
K
11
2860
PERISTEEN ANAL IRRIGATION SYSTEM, PERISTEEN ANAL IRRIGATION ACCESSORY UNIT, PERISTEEN ANAL IRRIGATION RECTAL CATHETER
K
11
2511
DOBBHOFF DUAL PORT FEEDING TUBE
K
11
2342
FLEXI-SEAL SIGNAL FECAL MANAGEMENT SYSTEM
K
11
3719
SAFETY SCREW CONNECTOR
K
12
0182
NEOMED GASTROINTESTINAL TUBE AND ACCESSORIES
K
11
2863
ENTERAL ADMINISTRATION SET WITH SOLUTION CONTAINER, ENTERAL ADMINISTRATION SET, ENTERAL EXTENSION SET WITH MINITUBE CONN
K
11
2268
CODAN SAFEFEED ENTERAL FEEDING RESERVOIR
K
12
0272
AMERITUS MEDICAL ENTERAL FEEDING EXTENSION SET
K
11
3351
CORTRAK ENTERAL ACCESS DEVICE
K
10
2712
MED GRAVITY SET, IMED PUMP SET
K
10
2741
ENTERAL FEEDING BAG AND SETS
K
11
0804
AMT G-J TUBE
K
11
2434
BD ORAL/ENTERAL SYRINGE WITH BD UNIVIA CONNECTION
K
11
0005
SYNCRO - BLUE TUBE, THE MAGNETICALLY GUIDED ENTERAL FEEDING TUBE- 8FR TUBE
K
11
0529
ENDOFLIP GASTRIC TUBE
K
10
3254
PERISTEEN ANAL IRRIGATION SYSTEM, IRRIGATION ACCESSORY UNIT, IRRIGATION RECTAL CATHETER, SYSTEM STRAP, IRRIGATION TUBE
K
10
2572
IYUNNI 3ID SUPRAPUBIC CYSTOSTOMY TUBE KIT
K
10
3109
PONSKY* NON-BALLOON REPLACEMENT GASTROSTOMY TUBE
K
10
2391
BARD DIGNISHIELD STOOL MANAGEMENT SYSTEM
K
10
2548
FOOTPRINT MEDICAL POLYURETHANE FEEDING TUBE
K
10
1199
GUIDE WIRE FOR EDI CATHETER, 8FR,125CM,5 EACH,GUIDE WIRE FOR EDI CATHETER, 8FR,125CM,5 EACH,GUIDE WIRE FOR EDI CATHETER,
K
10
0288
NEOMED ENTERAL ONLY EXTENSION SET
K
10
0366
MEDICINA ENTERAL FEEDING TUBES AND ACCESSORIES MODEL MGX/YY
K
10
0365
FARRELL VALVE WITH CORFLO ANTI-IV CONNECTORS MODEL 20-4300AIV
K
09
2628
ENTERAL FEEDING TUBE AND ACCESSORIES, FEEDING TUBE EXTENSION SET
K
10
0273
INSTAFLO BOWEL CATHETER SYSTEM KIT
K
10
0173
IYUNNI 3ID TRI-FUNNEL FEEDING TUBE KIT
K
09
3653
URESIL GASTROSTOMY CATHETER KIT , MODEL GCL-630HBK
K
08
3770
COLOPLAST PERISTEEN ANAL IRRIGATION (PAI) SYSTEM
K
09
2418
ENTRACARE GASTROSTOMY FEEDING TUBE
K
09
2049
IYUNNI 3ID TRI-FUNNEL GASTROSTOMY TUBE KIT
K
09
1637
CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
K
09
1759
SINGLE USE SPLINTING TUBE, MODELS ST-Y0002-S, ST-Y0002-H, ST-Y0003-S AND ST-Y0003-H
K
08
3685
ENDOVIVE LOW PROFILE REPLACEMENT GASTROSTOMY TUBE, MODEL 82XX, 8283, 8284, 8285
K
09
0559
FOOTPRINT MEDICAL SILICONE FEEDING TUBE
K
08
3684
ENDO VIVE STANDARD REPLACEMENT GASTROSTOMY TUBE, MODEL 82XX
K
08
3153
ACTIFLO INDWELLING BOWEL CATHETER SYSTEM KIT, MODELS: 32004, 32005, 32006, 32007
K
08
2710
SAFECHILD ENTERAL FEEDING TUBE AND ACCESSORIES AND FEEDING TUBE EXTENSION SET
K
08
2863
DYNAREX ENTERAL DELIVERY PUMP SET WITH SPIKE (1000ML), DYNAREX ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE (1000ML)
K
08
1739
2-PORT THROUGH-THE-PEG (TTP) JEJUNOSTOMY TUBE KIT
K
08
2654
ENTERAL ONLY EXTENSION SET
K
08
1725
ENTERAL PUMP SET, MODEL 20-1010
K
08
2241
THE DALE ACE CONNECTOR (ACCESS CONTROLLER FOR ENTERAL), MODEL H84104751
K
08
0679
MODIFICATION TO CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
K
07
3598
BARD DIGNICARE STOOL MANAGEMENT SYSTEM
K
08
0328
MPS ACACIA ENTERAL FEEDING TUBE
K
07
3034
AMT INITIAL PLACEMENT GI KIT (E2418) AND AMT DILATOR SET (E2419)
K
08
0340
COMPAT DUALFLO ENTERAL DELIVERY PUMP SET WITH SPIKERIGHT PIERCING SPIKE AND 1000 ML WAER BAG
K
07
2652
ENTERAL FEEDING SPIKE ADAPTER
K
07
2756
NON-IV ADAPTER FOR INFANT NG TUBE
K
07
2476
THROUGH-THE-PEG (TTP) JEJUNOSTOMY TUBE KIT
K
07
2550
SIGHTSURE OPERATIONAL INDICATOR, MODEL SS301
K
07
1579
PEF TUBE
K
07
2787
GABRIEL BLUE TUBE MAGNETICALLY GUIDED ENTERAL FEEDING TUBE, MODEL GFT-111
K
07
1764
REALIZE GASTRIC CALIBRATION TUBE, MODELS GCT180, GCT360
K
07
0449
LUMILOC (TM) SAFETY INTRODUCER NEEDLE
K
07
0124
GASTROSTOMY REPLACEMENT TUBE, MODEL 253
K
06
3061
CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
K
06
3118
BARD BALLOON DILATION KIT WITH TRIFUNNEL GASTROSTOMY TUBE
K
06
1432
HOSPIRA ENTERAL FEEDING SET, MODEL 20640
K
06
1021
ENTAKE STANDARD AND SAFETY PEG SYSTEM
K
05
2903
PEDIATRIC FEEDING TUBE
K
05
1206
Y2K2 ENTERNAL TUBE FLUID FILTER
K
05
1551
SMALL INTESTINAL VIDEOSCOPE SYSTEM
K
04
2431
PROCON2
K
04
3203
WILSON-COOK ENTERAL FEEDING TUBE, TIGER TUBE ENTERAL FEEDING TUBE
K
04
3044
ANTI-I.V. ENTERAL FEEDING SYSTEM
K
04
2112
INFANT FEEDING TUBE
K
04
1987
CORTRAK
K
04
3258
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER, PART NO. T4634-02
K
04
3114
KIMBERLY-CLARK MIC-KEY LOW PROFILE GASTROSTOMY TUBE
K
04
3027
MONARCH, TRANSSHAPING GASTROSTOMY TUBE, MODEL 9-XX20
K
04
2572
KENDALL CO2NFIRM NOW CO2 DETECTOR
K
04
2300
AMT INTRODUCER: MINI BUTTON DELIVERY SYSTEM
K
04
1034
SKIN LEVEL GASTROSTOMY TUBE KIT (ECSL)
K
03
0413
Y2K2 ENTERNAL FEEDING MANAGER
K
03
2734
CONVATEC FECAL MANAGEMENT SYSTEM
K
03
0784
NASOGASTRIC BRIDLE SYSTEM WITH MAGNETIC RETRIEVAL
K
03
1492
MOSSMED DUAL INTERMITTENT ASPIRATOR
K
03
3562
FASTRAC GASTRIC ACCESS PORT KIT
K
03
0841
COOK GASTRIC SIZING BALLOON CATHETER
K
02
2558
NGT
K
03
1538
ENDOVIVE INITIAL PLACEMENT PEG KIT, DIRECT PEJ KIT, AND PEG SAFETY KIT
K
03
0855
MODIFICATION TO ENDOVIVE INITIAL PLACEMENT PEG KIT, DIRECT PEJ KIT, PEG SAFETY KIT
K
02
2112
FORTUNE ALL SILICONE STOMACH (GASTRIC) TUBES, MODEL 2020
K
02
3344
INDWELLING FECAL MANAGEMENT SYSTEM-NON-STERILE
K
02
2648
ENDOVIVE INITIAL PLACEMENT DIRECT PEJ KIT, MODELS 6520 & 6521
K
02
1493
ANDERSEN NASOGASTRIC TUBE WITH STYLET, MODELS AN 11S, 13S, 14S & 18S
K
02
0120
ENDOVIVE INITIAL PLACEMENT DIRECT PEJ KIT, ENDOVIVE STANDARD PROFILE BALLOON REPLACEMENT, MODELS 6520, 6521, 6220
K
02
1991
MAGNAFLOW MAGNETICALLY GUIDED ENTERAL FEEDING TUBE
K
02
0005
INFANT FEEDING TUBES
K
01
4297
ENDOVIVE INITIAL PLACEMENT GASTROSTOMY KIT; ENDOVIVE LOW PROFILE BUTTON REPLACEMENT GASTROSTOMY TUBE; SECURI-T INITIAL P
K
02
1034
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
K
02
0985
MODIFIED TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
K
02
0379
PPD BALLOON DILATATION CATHETER
K
01
2113
INDWELLING FECAL MANAGEMENT SYSTEM
K
01
0798
RUSCH CANTOR TUBE
K
01
0797
RUSCH MILLER-ABBOTT TUBE
K
01
2147
DEVICE MODIFICATION OF ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE
K
01
3162
14F X 24CM ASH SPLIT-CATH,14F X 28CM ASH SPLIT-CATH, 14F X 32CM ASH SPLIT-CATH, 14FX36CM ASH SPLIT-CATH, 14F X 40CM ASH
K
01
3144
DUAL PORT WIZARD LOW PROFILE REPLACEMENT GASTROSTOMY DEVICE; DUAL PORT WIZARD FEEDING/DECOMPRESSION TUBE, MODEL 00220W
K
01
1341
LH400 YES-SET Y-PORT ENTERAL SPIKE PUMP SET
K
01
1343
LH 500 ENTERAL FEEDING GRAVITY BAG SET
K
01
1340
LH 450 ENTERAL FEEDING BAG PUMP SET W/INTEGRATED Y-PORT
K
01
2476
MONARCH, TRANSSHAPING GASTROSTOMY TUBE MODEL 9-2010
K
01
1467
ROSS EMBRACE PUMP SET
K
00
2838
GASTRIC SUCTION AND DRAINAGE CATHETER
K
01
1077
ANDERSEN INTESTINAL TUBE, MILLER-ABBOTT TYPE (AN 22)
K
00
1916
COMPAT REPLACEMENT GASTROSTOMY TUBE KIT, MODEL 0974XX
K
99
0365
GASTRIC LAVAGE VALVE
K
99
3358
SIGHTSURE OPERATION INDICATOR, MODEL SS301
K
99
4300
NASOGASTRIC TUBE HOLDER, MODEL 160
K
99
2719
AMSURE ENTERAL DELIVERY PUMP SET WITH SPIKE
K
99
3296
TRIP TONOMETRY CATHETER, 14F
K
99
1918
NUTRISAFE EXTENSION TUBE
K
99
3138
BALLARD MIC-KEY G LOW PROFILE GASTROSTOMY REPLACEMENT KIT
K
99
1375
BARD BALLOON INFLATION SYSTEM
K
99
2494
FLEXIFLO ENTERAL FEEDING TUBE
K
99
2181
TRIP TONOMETRY CATHETER, 8F
K
99
1668
COMPAT JEJUNOSTOMY TUBE KIT, MODEL 088OXX (XX=16,14, OR 12)
K
99
0863
MODIFICATION TO FLEXFLO POLYG GASTROSTOMY TUBE
K
99
0389
MOSS GASTROSTOMY TUBE
K
98
4628
MODIFICATION OF MOSS P.E.G. TRAY
K
98
3476
BIONAVIGATION SYSTEM FOR PLACEMENT OF ENTERAL FEEDING TUBES
K
98
4310
MOSS TUBES, INC, ALL SILICONE GASTROSTOMY TUBE
K
99
0127
CORFLO CUBBY LOW PROFILE GASTROSTOMY DEVICE (LPGD)
K
98
2500
CHAIT CECOSTOMY CATHETER
K
98
3366
TRIP TONOMETRY CATHETER, 16F
K
98
1323
COMPAT MINI-G REPLACEMENT GASTROSTOMY TUBE
K
98
2894
MIC-KEY GLOW PROFILE GASTROSTOMY REPLACEMENT KIT
K
97
1434
A.M.T. G-TUBE BALLOON REPLACEMENT GASTROSTOMY FEEDING DEVICE
K
98
1203
RUSCH BLAKEMORE 3 LUMEN, STERILE
K
97
3892
RUSCH BLAKEMORE TUBE - 4 LUMEN (MINNESOTA TYPE)
K
98
0305
AMT BUTTON REPLACEMENT GASTROSTOMY DEVICE
K
97
4806
VYGON NEO-SUMP
K
97
3409
KANGAROO ENTERAL FEEDING EXTENSION SET FOR SYRINGE PUMPS
K
97
2478
PRE-LOADED REPLACEMENT G-TUBES AND ACCESSORIES
K
97
2102
RADIUS PUSH OVER THE GUIDE WIRE PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
K
97
2025
RADIUS PULL PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
K
97
1901
RADIUS LOW PROFILE GASTROSTOMY TUBE KIT
K
97
3891
LAPAROSCOPIC GASTROSTOMY KIT
K
97
3893
AMT BALLOON STOMA MEASURING DEVICES, AMT BALLOON MEASURING DEVICE, AMT BALLOON MEASURING DEVICE WITH STOP VALVE, AMY BAE
K
97
1757
LOW PROFILE FEEDING SET ACCESSORY
K
96
2554
FLEXIFLO LOW-PROFILE BALLOON GASTROSTOMY TUBE
K
97
0849
ENTERAL NUTRITION 1000 ML/500ML
K
97
0178
CLOG ZAPPER ENTERAL FEEDING TUBE DECLOGGING SYSTEM
K
96
4920
RPI DUAL PORT IRRIGATION ADAPTER
K
97
1230
SHERWOOD MEDICAL COMPANY , KANGAROO, ENTRISTAR, PERCUTANEOUS GASTROSTOMY KIT
K
97
0890
#ES-32 SUCTION CATHETER 32 FR.
K
96
5087
COMPAT GASTROSTOMY/JEJUNOSTOMY FEEDING TUBE KIT(088000)
K
95
0017
FLEXIFLO FLOCATOR SMALL BOWEL FEEDING SYSTEM
K
96
1664
COMPAT NASOJEJUNAL FEEDING TUBE
K
96
3113
FLEXIFLO POLYG GASTOSTOMY TUBE
K
96
1345
DOMED PERCUTANEOUS ENDOSCOPIC GASTROSTOMY(P.E.G.) FEEDING TUBE
K
96
2375
MICROVASIVE BALLOON GASTROSTOMY TUBE KIT
K
93
5512
CORPAK REPLACEMENT GASTROSTOMY DEVICE STOMACORE
K
96
1884
CATH CADDIE
K
95
5181
U.S. ENDOSCOPY GROUP, INC. BALLOON REPLACEMENT GASTROSTOMY TUBE
K
95
5248
U.S. ENDOSCOPY PULL PEG KIT & U.S. ENDOSCOPY GUIDEWIRE PEG KIT
K
96
0677
KANGAROO JEJUNAL FEEDING SYSTEM
K
96
0632
KANGAROO FEEDING TUBE PLACMENT STYLET
K
96
0415
WILSON-COOK BALLOON INFLATION DEVICE
K
96
0177
P.E.G. PATIENT CARE KIT
K
95
4879
PERCUTANEOUS REPLACEMENT GASTROSTOMY FEEDING CATHETER TRAY (MODIFICATION)
K
95
4429
KANGAROO ENTRISTAR SKIN-LEVEL GASTROSTOMY KIT
K
95
4776
REPLACEMENT GASTROSTOMY FEEDING CATHETER TRAY
K
94
6249
BARD(R) JEJUNAL FEEDING/GASTRIC DECOMPRESSION TUBES
K
92
2567
LOW PROFILE CATHETER
K
94
5618
GASTROINTESTINAL TUBES & ACCESSORIES
K
94
1228
ENDOLUMINAL ACCESS TUBE
K
95
3375
NG SECURE
K
94
6140
PRG BUTTON
K
95
3232
HOLLISTER NASOGASTRIC TUBE ATTACHMENT DEVICE
K
92
3488
GASTRANIMAL PERCUTANEOUS REPLACEMENT GASTROOMY
K
93
1921
CORPAK GASTROSTOMY TUBE
K
95
1489
MRI'S ALL SILICONE GASTROSTOMY TUBE
K
93
2880
GRASSI GASTROJEJUNOSTOMY TUBE
K
92
4306
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY
K
94
5612
MIC NASOGASTRIC-GASTROJEJUNAL FEEDING TUBE
K
94
3240
FLEXIFLO SIX ENTERAL NUTRITION PUMP SET
K
92
2217
FLEXIFLO NASOENTERIC FEEDING TUBE
K
94
5012
CATCO NUTRITIONAL CATHETER
K
94
0548
MIC PERCUTANEOUS ENDOSCOPIC JEJUNAL FEEDING TUBE
K
92
1478
GUARDPORT
K
92
2216
FLEXIFLO TUBE PLACEMENT VERIFIER
K
94
3675
ENTERAL DELIVERY SETS WITH HYDRATION PORT
K
92
4850
VANSONNENBERG GASTROSTOMY CATHETER
K
94
3685
MIC DISPOSABLE SNARE
K
93
5633
NO-MES
K
92
3046
BIOLOGIC DT-1000 MACHINE
K
93
3842
KLEIN RECTAL TAMPNADE BALLOON
K
93
5198
GASTROENTEROLOGY AND UROLOGY GUIDEWIRE MODIFICATIONS
K
92
6581
MIC TRANSGASTRIC JEJUNAL TUBE
K
93
2295
NON-BALLOON REPLACEMENT GASTROSTOMY KIT
K
93
5045
BIOSEARCH LAPROSCOPIC GASTRONOMY CATHETER
K
92
0579
LOW PROFILE PASSPORT PUSH & PULL KITS & PEG TUBE
K
92
3002
ENTEROCLYSIS TUBE
K
92
5061
HELLER TRANSILLUMINATING STYLETTE
K
92
3168
DUAL PORT ENTERAL Y-ADAPTOR
K
93
2861
FLEXIFLO GASTROSTOMY KIT
K
92
5102
FLEXIFLO LAPAROSCOPIC JEJUNOSTOMY KIT
K
92
1680
E-Z PEG
K
92
5854
VYGON - ENTERAL FEEDING TUBE - POLYURETHANE
K
92
1652
MIC TRANSGASTRIC JEJUNAL FEEDING TUBE KIT
K
92
1370
MIC GASTRO-ENTEROSTOMY TUBE MODIFICATION
K
93
6168
WILSON-COOK BALLOON INFLATION DEVICE
K
93
4772
GASTRONOMY TUBE HOLDER
K
92
5261
NUTRICARE ENTERAL FEEDING TUBE
K
92
4065
MIC PEG TUBE
K
92
2998
ENFUSE ENTERAL FEEDING TUBE
K
92
0703
GASTROINTESTINAL FEEDING TUBE
K
92
2667
MIC LOW PROFILE GASTROSTOMY TUBE
K
93
0456
INTHERM SINGLE-STICK RADIALLY EXPANDING DILATOR
K
93
2855
HOLLISTER VERTICAL DRAIN/TUBE ATTACHMENT DEVICE
K
92
4996
FLEXIFLO 60 NASOJEJUNAL FEEDING TUBE
K
92
4697
FLEXIFLO LAPAROSCOPIC GASTROSTOMY KIT
K
92
4308
GASTROPORT II
K
92
1853
4 SURE TM FEEDING TUBES
K
91
5841
BARD GAUDERER UNIVERSAL PERCUTANEOUS ENDOSCOPIC
K
92
3692
STOMA MEASURING DEVICE
K
92
0262
ONAT BALLOONED NASOGASTRIC TUBE
K
92
3983
PEG GUIDEWIRE SYSTEM GASTROSTOMY TUBE KIT
K
91
5837
NON-BALLOON REPLACEMENT GASTROSTOMY SYSTEM
K
92
3474
LOW PROFILE GASTROMSTOMY DEVICE
K
92
1127
PANDA NEEDLE CATHETER JEJUNOSTOMY KIT
K
92
0493
PEG PREP TRAY
K
92
2209
NASOGRASTRIC TUBBE HOLDER
K
92
1697
FLEXIFLO COMPANION ENTERAL PUMP SETS AND CONTAINER
K
91
5735
FLEXIFLO QUANTUM ENT. PUMP SETS AND ENT. NUT. CONT
K
92
0894
DECOMPRESSION TUBES
K
92
1026
PRESSURE GAUGE
K
91
5110
FLEXIFLO OVER-THE-GUIDEWIRE GASTROSTOMY KIT
K
91
4375
NON-WEIGHTED POLYURETHANE ENTERAL FEEDING TUBE
K
91
3997
SAECG CARDIOGRAPH MODEL M1754A
K
91
3476
GI BLEEDER/OD SET
K
91
5171
LOPEZ VALVE TM II
K
91
3784
DOBBHOFF(R) SINGLE PASS PEG KIT
K
91
3786
FLEXIFLO OVER-THE-GUIDEWIRE GAST KIT W/CR-BAR BUMP
K
90
0623
ZIMMON ESOPHAGO-GASTRIC BALLOON TAMPONADE DEVICE
K
91
3603
FIBRETWINS
K
91
2047
WILSON-COOK RUSSELL GASTROSTOMY KIT
K
91
0382
FLEXIFLO ENTERAL FEEDING TUBE
K
91
1897
GASPARAITIS ESOPHAGRAM CATHETER SET
K
91
0910
MOSS- ANCHOR SET
K
91
0912
MOSS NASAL TUBE MARK IV
K
91
0911
MOSS P.E.G. TRAY
K
91
0913
MOSS GASTROSTOMY TUBE
K
91
0332
FLEXIFLO SACKS-VINE GASTROSTOMY KITS
K
90
5164
TUBE DECLOGGER
K
90
2623
FLEXIFLO STOMATE EXTENSION TUBE
K
90
3662
PEEWEE REPLACEMENT GASTROSTOMY TUBE
K
90
0464
MIC PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE
K
90
3579
FLEXIFLO STOMATE DECOMPRESSION TUBE
K
90
3325
FLEXIFLO (R) VERSA-PEG (TM) GASTROSTOMY KIT
K
90
2099
WILSON-COOK VARICES TAMPONADE BALLOON CUFF
K
89
5650
ENTERAL PUMP SET W/ENTERA-FLO SPIKE
K
89
5329
600ML AND 1200ML ENTERAL BAG ADM. SET FOR ENTERA
K
89
5142
ENTERAL PUMP SET WITH ENTERAL SPIKE
K
90
2641
RPI ENTERAL FEEDING BAG 1000ML AND 500ML
K
90
2684
MIC ANAL INCONTINENCE TUBE
K
90
1835
LAKE N/G FEEDING TUBE (WITH Y PORT CONNECTOR)
K
90
2729
R.P.I. GRAVITY SAFE FEEDING BAG
K
90
0624
DOBBHOFF(R) GASTROTRAC JEJUNAL FEEDING SYSTEM
K
90
0590
BIOSEARCH DOBBHOFF(R) GASTROTRAC JEJUNAL FEEDING
K
90
0563
DOBBHOFF(R) ENDOENTERIC GASTRIC DECOMPRESSION CATH
K
90
0324
DOBBHOFF WIRE GUIDED JEJUNAL FEEDING TUBE
K
90
1023
GASTROINTESTINAL TUBES AND ACCESSORIES
K
90
1574
ACKRAD MPR DRAINAGE CATHETER SET
K
90
1683
IMPROVED BAKER TWIN-CUFF SUMP TUBE
K
90
1134
ENTERA-FLO REPLACEMENT GASTROSTOMY TUBE
K
90
1753
600 OR 1200 ML. ENTERAL BAG ADMINISTRATION SET
K
90
1130
ENTERA-FLO FEEDING TUBE
K
90
0852
MAGNET RETRIEVAL CATHETER
K
89
5933
ENTERAL PUMP SETS FOR USE WITH ROSS FLEXIFLO-III
K
89
5919
ENTERAL BAG ADMINI. SETS FOR USE W/FLEXIFLO-III
K
89
5696
ENTERAL PUMP SET W/ENTERAL SPIKE FOR USE W/FEED PU
K
89
5330
600ML AND 1200ML ENTERAL BAG ADM. SET FOR FRENTA
K
89
5366
ENTERAL PUMP SET WITH ENTERA (TM)-FLO SPIKE
K
89
5246
FRENTA(R) DUO-SET
K
89
6210
GASTRIC SUMP TUBE
K
89
5706
TUBING ORGANIZER
K
89
5616
L.T.C. FEEDING TUBE
K
89
3888
HOLLISTER FEEDING TUBE ATTACHMENT DEVICE
K
89
3541
VINYL BAG W/GRAVITY ADMINISTRATION SET
K
89
3540
VINYL BAG W/PUMP ADMINISTRATION SET
K
89
4857
PEDI-TUBE(R) STYLET
K
88
5220
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY KIT
K
89
1371
GILSDORF PERCU. ENDO.-PEG & PERCU. FLOURO.-PFG
K
89
3209
ENTERA-FLO SPIKE SET
K
89
0093
PVC EMPTY SOLUTION CONTAINER ENTERAL PUMP SET
K
89
2439
KENDALL CURITY STOMACH TUBES
K
89
0424
ENTERAL FEEDING CONTAINER
K
89
0430
ENTAINER(TM) ENTERAL FEEDING CONTAINER
K
89
0151
ENTERAL BAG/SET
K
89
1109
PANDA(R) NEEDLE CATHETER JEJUNOSTOMY TUBE
K
89
0871
BARD MOSS(R) GASTROSTOMY TUBE
K
89
0870
BARD GASTROSTOMY FEEDING DEVICE
K
88
5339
FLOW THRU 16,18,20,22 FR REPLACE. GASTRO TUBE KIT
K
89
0552
CP&S GAVAGE CONSTAINER, DISPOSABLE
K
88
4127
LAKE N/G FEEDING TUBE
K
88
4275
FLEXIFLO INTRODUCER (DIRECT STICK) GASTROSTOMY KIT
K
88
4309
NH PEDIATRIC REPLACEMENT GASTROSTOMY KIT
K
88
4128
LAKE N/G EXTENSION SET
K
88
4439
GASTROSTOMY FEEDING DEVICE
K
88
3319
HILL NASOGASTRIC TUBE
K
88
2918
KIM NASO-INTESTINAL TUBE
K
88
2682
COMPAT ENTERAL DELIVERY SYSTEM
K
88
2867
CORPAK PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE
K
88
2218
COMPAT (R) ENTERAL DELIVERY SYSTEM
K
88
2089
MRM GASTROSTOMY BELT
K
88
3351
PERCUTANEOUS ENDOSCOPIC GASTROSTOMY FEEDING TUBE
K
88
3336
GASTROSTOMY FEEDING TUBE
K
88
0767
MIC NEEDLE JEJUNOSTOMY TUBE KIT
K
88
1978
ENTERAL FEEDING TUBES
K
88
1162
ENTERA* ENTERAL FEEDING BAG
K
87
5232
INTRO-REDUCER (NASOGASTRIC TUBE)
K
88
1310
DENT SLEEVE MANOMETRIC CATHETER
K
87
4154
ELECATH(R) TRANSESOPHAGEAL PACING CATHETER
K
88
0768
MIC (SPECIFIC LINE) REPLACEMENT KIT
K
88
0201
REPLACEMENT SILICONE GASTROSTOMY TUBE KIT #87600
K
88
0051
ENTERAL BAG/SET
K
87
4936
MEDSURG PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TRAY
K
87
5171
J-CATH(TM)
K
87
4755
EFFNER FE-EX* OROGASTRIC
K
87
3360
ENTERON PERCUTAN. ENDOSCOPIC GASTROSTOMY TRAY-PEG
K
88
0232
NH REPLACEMENT GASTROSTOMY KIT
K
87
5126
MIC (SPECIFIC LINE) INSERTION KIT
K
87
1848
NUTRITION DELIVERY SETS FOR VM 05 AMBULA. PUMP
K
87
4393
ENTERAL FEEDING TUBE
K
87
3343
ENTUBE-MEER AND MEER FEEDING TUBE BRIDLE SYSTEM
K
87
2921
MSS ENTERAL DELIVERY SET
K
87
3441
BAKER TWIN-CUFF INTESTINAL DECOMP/PLICATION TUBE
K
87
2771
LOW PROFILE GASTROSTOMY
K
87
2932
MOSS(R) MARK IV NASAL TUBES CAT.# 87168
K
87
2531
MIC MUSHROOM TIP GASTROSTOMY TUBE
K
87
1846
FLEXIFLO TOPTAINER TOP-FILL ENTERAL NUTRIT. SYSTEM
K
87
2096
INFANT FEEDING KIT/SET NASOGASTRIC FEEDING KIT
K
87
2097
INFANT FEEDING TUBE
K
87
1691
MODIFIED MULTI-LUMEN NASOGASTRIC TUBE
K
87
1528
ENTRIMIT GRAVITY FEEDING SET
K
87
1554
MOSS(R) GASTROSTOMY TUBE CAT #5-17719
K
87
1019
ENFUSE ENTERNAL ADMINISTRATION SET & PUMP SET
K
87
1003
ENTROSET-SW
K
87
0508
GASTROINTESTINAL TUBE
K
86
4683
NEONATAL FEEDING KIT
K
86
4364
WINDSOR SAFETY-TOP ENTERAL FEEDING BAG/BAG & SET
K
86
4218
PROCON
K
86
1323
REPLACEMENT GASTROSTOMY TUBE
K
86
1309
JEJUNAL FEEDING TUBE
K
86
4182
ENTERAL ADMINISTRATION ADAPTERS
K
86
2855
CRAIG NASO-GASTRIC TUBE HOLDER
K
86
1599
T-FASTENER
K
86
2573
HOLLISTER DRAIN TUBE ATTACHMENT
K
86
2489
ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE
K
86
1494
EMPTY SOLUTION TRANSFER CONTAINER 1,500 ML
K
86
2091
MCGAW NUTRA-FEED EFS ENTERAL FEEDING TUBE
K
86
1862
DIETO CONTAINER FOR ENTERAL NUTRITION
K
86
1427
ENTUBE TM, ENTERAL FEEDING TUBE
K
86
1618
TRAVASORB FEEDING TUBES - (2L8014) AND (2L8024)
K
86
1090
NUTRI-CATH - FEEDING TUBE
K
86
1552
TOP-PORT ENTERAL FEEDING BAG AND PREATTACHED SETS
K
86
0818
ONE TIME ENTERAL FEEDING BAG
K
86
0991
SCLEROTHERAPY INJECTION CATHETER
K
85
5098
COMPAT ENTERAL DELIVERY SYSTEMS
K
85
5097
COMPAT ENTERAL DELIVERY SYSTEMS
K
86
0589
INFLATOR/DEFLATOR PISTON SYRINGE
K
86
1051
ISOLIFE DISPENSING SYSTEM
K
86
0285
XRO GASTRO-DUODENAL, DUAL FLOW TUBE, SALEM TYPE
K
86
0052
QWIK-CALL
K
86
0075
DYNAFEED ENTERAL PUMP FEED BAG
K
85
4616
ENTERAL FEEDING BAG
K
85
4660
THE MMG ENTERAL FEEDING ADMINISTRATION SET
K
85
5121
COLOSHIELD KIT
K
85
4215
DYNAFEED
K
85
3384
E-Z-EM GASTRIC LAVAGE CATHETER
K
85
3253
CORPAK FARRELL VALVE ENTERAL GASTRIC PRESSURE RELI
K
85
3353
88000 GASTROSTOMY-JEJUNAL FEEDING TUBE KIT
K
85
2552
COONS GASTROSTICK SYSTEM
K
85
2535
E-Z P.E.G. W/PERCUTANEOUS ENDOSCOPY GASTROSTOMY
K
85
3288
FEEDING UNITS & TUBES
K
85
1975
ENTERAL FEEDING BAG, 1000 ML, & TUBING SET
K
85
3309
P.A. ENTERAL FEEDING BAG 1100
K
85
2966
ENTERAL FEEDING CONTAINER
K
85
3197
MIC JEJUNAL FEEDING TUBE
K
85
2707
GASTRO-ENTEROSTOMY TUBE
K
85
2363
MIC GASTROSTOMY TUBE PERCUTANEOUS INSERTION KIT
K
85
2792
CORPAK ENTERAL SOL ADM PUMP SET W/ SCREW
K
85
1672
NYHUS/NELSON TUBE
K
85
0664
ENDO-TUBE
K
85
1671
GASTROINTESTINAL TUBE
K
85
1539
CHESEBROUGH-PONDS KANGAROO PUMP SET W/EASY-CAP CLO
K
85
1444
KEITH-A.R.V.
K
83
2170
MUFFLER GAS-AIR VENT UNIT
K
85
0182
IVAC KEOFEED II POLYURETHANE FEEDING TUBE
K
85
0134
ENTRON ENTERAL FEEDING BAG
K
84
3939
PEDIATRIC SIZE K-TUBE A OR B
K
84
3567
KANGAROO NASOGASTRIC FEEDING TUBE
K
84
4745
K-TUBE
K
84
4789
KANGAROO ACCESS II ENTERAL FEEDING CONTAINER
K
84
4203
ENTERNAL FEEDING TUBE SILICONE-EF401, 402 & 403
K
84
4175
ENTERNAL FEEDING TUBE-POLYURETHANE EF504
K
84
4174
FLEXIBLE STAINLESS STEEL STYLET FOR ENTERNAL FEEDI
K
84
2174
PERCUTANEOUS GASTROSTOMY TUBE
K
84
4222
BIOSEARCH GLASER PEG PERCUTANEOUS ENDOSCOPIC GASTR
K
84
3975
9 FRENCH 42LONG POLYURETHANE GRADUATED ENTERIC FE
K
84
2808
URITROL-M
K
84
3392
GAUDERER GASTROSTOMY BUTTON
K
84
3305
DAVOL GAUDERER-PONSKY PERCUTAN-ENDOSCOP
K
84
1986
PROTOMED/TOWIC NASOGASTRIC TUBE DRAINAGE BAG
K
84
2841
VIVONEX TUNG STEN TIP TUBE
K
84
2589
IVAC KEOFEED HYDROPHILIC FEEDING TUBE
K
84
2076
MIC GASTROSTOMY TUBE
K
84
1945
ENTERAL FEEDING BOTTLE
K
84
1349
ESOPHAGEAL TUBE
K
84
1428
JEJUNOSTOMY SET FOR TUBE FEEDING
K
84
1289
RECTAL IRRIGATION TUBE
K
84
0864
GORE-TEX CATHETER
K
84
1330
GASTROSTOMY FEEDING TUBE
K
84
0752
ENTEROCYSIS TUBE W/GUIDE WIRE & CONNECT
K
84
1014
WEIGHTED FEEDING TUBE W/PRE-INSERTED
K
84
1034
DEAVER T-DRAIN & CATTEL T-DRAIN
K
84
1039
CANTOR TUBE
K
84
1038
BLAKEMORE TUBE
K
84
1036
RECTAL BALLOON CATHETERS
K
84
1033
MILLER-ABBOTT TUBE
K
84
1035
ULTRA BAKER JEJUNOSTOMY TUBE
K
84
0916
DIETO CONTAINER FOR ENTERNAL NUTRIT
K
84
0656
ENTERNAL Y EXTENSION SET RECORDER
K
84
0936
NEEDLE CATHETER JEJUNOSTOMY REPAIR KIT
K
83
3687
DISPOS. ENTERIC FEEDING TUBES W/SAFE-T
K
83
4562
ENTERNAL FEEDING TUBE
K
84
0019
K-TUBE REPAIR KIT
K
83
4554
ETHOX WEIGHTED FEEDING TUBE
K
83
4268
ISLAMI GASTROINTESTINAL TUBE
K
83
4258
HODGE DECOMPRESSION TUBE
K
83
3947
SUPERIOR ENTERNAL FEEDING SYSTEM
K
83
2093
FEEDING GASTROSTOMY TUBE
K
83
3492
PERCUTANEOUS ENDOSCOPIC GASTROSCOPY
K
83
3621
ENTRI FLEX FEEDING TUBE
K
83
3591
FEEDING TUBE
K
83
3513
NEEDLE CATHETER JEJUNOSTOMY KIT
K
83
2859
FOAM HELMET - USE W/ESOPHAGEAL TAMPONA
K
83
3293
LEIDER FEEDING TUBE W/HYDROMER LUBR
K
83
2966
FLEXIFLO ENTERAL FEEDING TUBE
K
83
3054
GASTRIC SUMP TUBES
K
83
2927
GRAVITY ENTERAL FEEDING SET
K
83
2196
SHERIDAN/LEVI-A-SUMP
K
83
2672
FOUR LUMEN BLAKEMORE TUBE
K
83
2293
ENTERNAL FEEDING TUBE
K
83
1971
VIVONEX TUNGSTEN TIP TUBE-TWISTED WIRE
K
83
1968
VIVONEX TUNGSTEN TIP TUBE-BRAIDED
K
83
1969
VIVONEX TUNGSTEN TIP TUBE-WOUND
K
83
2501
ENEMA TUBE
K
83
1847
JEJUNOSTOMY KIT
K
83
1840
FEEDING TUBE PLACEMENT STYLET
K
83
1823
AXIOM FEEDING GASTRO TUBE
K
83
1631
GASTROSTOMY FEEDING SET
K
83
1328
NEONATAL NASOGASTRIC FEEDING TUBE-
K
83
1970
VIVONEX TUNGSTEN TIP TUBE-MONOFILA-
K
83
1974
STOMACH TUBE LEVIN TUBE
K
83
1868
DOBBHOFF FEEDING TUBE W/HYDROMER LUB
K
82
3475
BROOKS SCLEROTHERAPY CUFF
K
83
1009
CANTOR TUBE
K
83
0990
BLAKEMORE TUBE
K
83
0989
BAKER JEJUNOSTOMY TUBE
K
83
0998
MILLER-ABBOTT TUBE
K
83
0985
STOMACH TUBE
K
83
0987
LEVIN TUBE
K
83
0986
RECTAL TUBES
K
83
0794
ARGYLE MADEN SILICONE GASTROSTOMY TUBE
K
83
1167
ENTERAL PUMP SET
K
83
1168
ENTERAL DELIVERY SET
K
83
1169
TOP-FILL BAG
K
83
0965
ENTERAL SOLUTION ADMIN. PUMP SET
K
83
0710
ARGYLE SILICONE SALEM SUMP TUBE
K
83
0119
NEEDLE CATHETER JEJUNOSTOMY KIT
K
82
3195
GASTRIC LAVAGE KIT
K
82
2087
DIA SCOPE
K
82
3082
TRAVASORB NASOGASTRIC NASOINTESTINAL
K
82
2879
ENTERAL NUTRITION 1
K
82
2004
FACE SHIELDS
K
82
2875
PEDI-TUBE PEDIATRIC FEEDING TUBE
K
82
2565
NEEDLE CATHETER JEJUNOSTOMY KIT
K
82
2380
ROMBEAU GASTROSTOMY-JEJUNAL TUBE
K
82
2631
ARGYLE DUO-TUBE
K
82
2228
GASTRO VAGE SET FOR GASTRIC LAVAGE
K
82
2443
NASO-GARD NASOGASTRIC TUBE HOLDER
K
82
1825
CONPHAR SILICONE FEEDING TUBE
K
82
1906
CORPAK ENTERIC FEEDING TUBE W/GUIDE TIP
K
82
1409
CORPAK-ENTERAL FEEDING CONTAINER
K
82
1410
CORPAK-MONITOR ENTERAL FEEDING CONTAIN
K
82
1231
VIVONEX TUNGSTEN TIP TUBE PLACEMENT
K
82
1067
VIVONEX ACUTROL ENTERNAL FEEDING SYS
K
82
1036
ENTERNAL SOLUTION ADMIN. SET
K
81
3585
WATERS ILEOSTOMY VALVE
K
82
0420
AM. PH. STERILE FEEDING TUBE
K
82
0441
ARGYLE PVC FEEDING TUBE
K
82
0442
ARGYLE INDWELL FEEDING TUBE
K
82
0176
VYGON ENTERNAL NUTRITION TUBES
K
81
3526
FECAL SANITARY TUBE
K
81
3132
THE CHICAGO GULLET
K
81
3169
CELESTIN PULSION ESOPHOGEAL PROSTHESIS
K
81
2648
EHTOX GASTRIC LAVAGE KIT #2050 & #2070
K
81
2427
CARTMILL/BARRY FEEDING TUBE
K
81
2507
THE KEOFEED STOMACH TUBE
K
81
2102
O.N.A.T.
K
81
2279
ENTER-A1 ENTERIC FEEDING TUBE
K
81
1968
VIVONEX TUNGSTEN TIP
K
81
1683
ENTRI ENTERNAL FEEDING SET
K
81
1533
MGN FEEDING TUBE
K
81
1639
ETHIX FEEDING TUBES POLYURETHANE/RADIOP.
K
81
1061
AUTOMATED GASTRIC LAVAGE
K
81
0979
ARROW NEEDLE-CATHETER JEJUNOSTOMY KIT
K
81
0996
ENTERNAL PUMP SET W/INTEGRAL CONTAINER
K
81
0573
TUBE FEEDING SET
K
81
0854
KANGAROO NASOGASTRIC FEEDING TUBE
K
81
0250
TRAY, IRRIGATION
K
81
0392
OESOPHAGEAL THERAPY KIT
K
81
0499
PERCUTANEOUS GASTROINTESTINAL TUBE
K
81
0156
ARGYLE SALEM SUMP TUBE
K
80
2585
FEEDING TUBES IN SILICONE 5,6,8&10 SIZES
K
80
2482
KEOFEED (R) EASY-FILL ENTERIC FEED BAG
K
80
2300
VIVONEX JEJUNOSTOMY KIT
K
80
1558
ENTERIC FEEDING TUBE W/SEGM. FLEX. WT.
K
80
1511
NASO-GARD NASOGASTRIC TUBE HOLDER
K
80
1498
ENTRI NASOGASTRIC FEEDING TUBE
K
80
0918
MODIFIED FEEDING JEJUNOSTOMY TUBE
K
80
0815
ENTERAL & NASOGASTRIC SOL. ADMIN. SET
K
80
0955
TUBE FEEDING CONTAINER 1500 ML DISPOSE.
K
80
0508
STOMACH TUBES
K
80
0510
RECTAL & HARRIS FLUSH TUBES
K
80
0507
FEEDING TUBES
K
79
2597
RECTAL LEAKAGE INHIBITOR
K
79
2333
BAKER INTESTINAL TUBE, TWIN CUFF
K
79
1714
SURGIFEED
K
79
1758
CLINIFEEDING SYSTEM 1
K
79
1250
CONPHAR STOMACH TUBE-STERILE-X-RAY
K
79
1269
CONPHAR STOMACH TUBE-STERILE
K
79
1268
CONPHAR RECTAL TUBE-STERILE
K
79
1257
CONPHAR FEEDING TUBE-STERILE
K
79
0612
NUTRIFLOW NASOGASTRIC FEEDING TUBE
K
79
0387
FEEDING TUBE W/ LUBRICANT COATING
K
78
1230
GAVAGE ADMIN. SET
K
76
0945
SILASTIC PERCUTANEOUS GASTROINTEST. TUBE
K
76
0708
SILASTIC BRAND Q7-2091 GASTRIC SUMP TUBE
KNX
Collector, Urine, (And Accessories) For Indwelling Catheter
KNY
Accessories, Catheter, G-U
KNZ
Accessories, A-V Shunt
KOB
Catheter, Suprapubic (And Accessories)
KOC
Accessories, Blood Circuit, Hemodialysis
KOD
Catheter, Urological
KOE
Dilator, Urethral
KPF
System, Dialysate Delivery, Semi-Automatic, Peritoneal
KPH
Catheter, Rectal For Continent Ileostomy
KPI
Stimulator, Electrical, Non-Implantable, For Incontinence
KPL
Colonic Irrigation System
KPM
Shunt, Peritoneal
KPO
Dialysate Concentrate For Hemodialysis (Liquid Or Powder)
KPP
Peritoneal Dialysate Filter
KQQ
Tubing, Dialysate (And Connector)
KQR
Detector, Air Or Foam
KXM
System Accessories, Extracorporeal
LBW
Set, Dialysis, Single Needle (Co-Axial Flow)
LCG
Intestinal Splinting Tubes
LFJ
Catheter, Subclavian
LFK
Catheter, Femoral
LIF
Dialyzer Reprocessing System
LJH
System, Irrigation, Urological
LKY
Device, External Penile Rigidity
LLB
System, Blood, Extracorporeal And Accessories
LNS
Lithotriptor, Extracorporeal Shock-Wave, Urological
LQR
Dislodger, Stone, Biliary
LRI
Ph Meter For Dialysis Hydrogen Ion Concentration
MJC
Catheter, Urological (Antimicrobial) And Accessories
MLW
Warmer, Peritoneal Dialysate
MNG
External Urethral Occluder, Urinary Incontinence-Control, Female
MNV
Strip, Dialysate Ph Indicator
MON
System, Hemodialysis, Remote Accessories
MPB
Catheter, Hemodialysis, Non-Implanted
MQS
System, Hemodialysis, Access Recirculation Monitoring
MSB
System And Accessories, Isolated Heart, Transport And Preservation
MSD
Catheter, Hemodialysis, Implanted
MSE
Hemodialyzer, Re-Use, Low Flux
MSF
Hemodialyzer, Re-Use, High Flux
MSY
Strip, Test, Reagent, Residuals For Dialysate, Disinfectant
MSZ
Strip, Test, Reagent, Residuals For Dialysate
NAM
Stimulator, Peripheral Nerve, Non-Implanted, For Pelvic Floor Dysfunction
NDS
Media, Culture, Ex Vivo, Tissue And Cell
NFK
Kit, Repair, Catheter, Hemodialysis
NHV
System, Water Purification, General Medical Use
NIE
Catheter, Hemodialysis, Triple Lumen, Non-Implanted
NIF
Catheter, Hemodialysis, Triple Lumen, Implanted
NML
Catheter, Biliary, Reprocessed
NNE
Needle, Fistula, Reprocessed
NNG
Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed
NNW
Bag, Urine Collection, Leg, For External Use, Non-Sterile
NNX
Device, Incontinence, Urosheath Type, Non-Sterile
NNY
Sheath, Corrugated Rubber, For Non-Indwelling Catheter, Non-Sterile
NNZ
System, Urine Drainage, Closed, For Non-Indwelling Catheter, Non-Sterile
NOA
Device, Paste-On For Incontinence, Non-Sterile
NOO
Clamp, Dialysis Arm
NOY
Agents, Embolic, For Treatment Of Benign Prostatic Hyperplasia
NQJ
Catheter, Hemodialysis, Non-Implanted, Ultrafiltration, For Peripheral Use
NTZ
Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator
NUB
Colonic Irrigation System, General Well Being
NYU
Catheter, Hemodialysis, Implanted, Coated
NWO
Kit, Catheter, Urinary (Exludes Hiv Testing)
NWP
Suprapubic Cystostomy Catheter Kit
NWQ
Kit, Catheter, External, Male (Excludes Hiv Testing)
NWR
Kit, Catheter, Foley (Excludes Hiv Testing)
NZU
Collector, Urine, Powered, Non Indwelling Catheter
ODN
Ultrafiltration-Controlled Nocturnal Dialysate Delivery System
ODX
Autonomous Extracorporeal Blood Leak Detector/Alarm
OHR
Catheter Care Tray
ONW
Hemodialysis System For Home Use
ONY
Oral Removable Retainer For Weight Management
PBP
Rectal Insert
PCU
Pancreatic Stent, Covered, Metallic, Removable
PEH
Hemodialysis Catheter Luer End Cap
PEV
Dialysis Administration Kit
PEW
Implantable Transprostatic Tissue Retractor System
PFH
Venous Window Needle Guide
PIA
Vibrator For Climax Control Of Premature Ejaculation
PID
Esophageal Dilator Balloon With Or Without Electrode Sensors
PIE
Esophageal Dilator With Balloon And Electrode Sensors
PIF
Gastrointestinal Tubes With Enteral Specific Connectors
QGC
Suprapubic Catheter Accessories
PIH
Urethral Insert With Pump For Bladder Drainage
PIN
Kidney Perfusion Kit
PIO
Enteral Specific Transition Connectors
PJH
Dynamic Rectal Control System
PKI
Fully Subcutaneous Implanted Hemodialysis Catheter
PLI
Gastrointestional Tube Holder
PLQ
Enzyme Packed Cartridge