VITALITY SYSTEM

K993143 · Soma Blue, Inc. · LKY · Dec 27, 1999 · Gastroenterology, Urology

Device Facts

Record IDK993143
Device NameVITALITY SYSTEM
ApplicantSoma Blue, Inc.
Product CodeLKY · Gastroenterology, Urology
Decision DateDec 27, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.5020
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Vitality System consists of a manual vacuum pump, a cylinder, cushion inserts, constriction ring loader, constriction rings, and lubricant. The Vitality System's intended use is to manage erectile dysfunction by allowing the creation of a full erection suitable for sexual activity. This is accomplished through the use of the manual vacuum pump to remove air from the cylinder, creating vacuum pressure within the cylinder. Blood is thereby drawn into the penis, causing it to become erect. The constriction ring is then placed around the base of the erect penis to restrict the outflow of blood. When activity is complete, the ring is removed from the base of the penis. This product is intended for over the counter use.

Device Story

Vitality System is a vacuum erection device (VED) for management of erectile dysfunction. Components include manual vacuum pump, cylinder, cushion inserts, constriction ring loader, constriction rings, and lubricant. User operates manual pump to evacuate air from cylinder placed over penis; negative pressure induces blood engorgement and erection. Constriction ring is manually transferred from loader to base of penis to maintain erection by restricting venous outflow. Ring is removed after sexual activity. Device is intended for over-the-counter (OTC) use by patients in home setting. Provides non-invasive, mechanical method to achieve and maintain erection.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Mechanical vacuum erection device. Components: manual vacuum pump, cylinder, cushion inserts, constriction ring loader, constriction rings, lubricant. Non-powered, manual operation. No software or electronic components.

Indications for Use

Indicated for management of erectile dysfunction in adult males to facilitate erection suitable for sexual activity.

Regulatory Classification

Identification

External penile rigidity devices are devices intended to create or maintain sufficient penile rigidity for sexual intercourse. External penile rigidity devices include vacuum pumps, constriction rings, and penile splints which are mechanical, powered, or pneumatic devices.

Special Controls

*Classification.* Class II (special controls). The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. The special control for these devices is the FDA guidance document entitled “Class II Special Controls Guidance Document: External Penile Rigidity Devices.” See § 876.1(e) for the availability of this guidance document.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three curved lines representing its body and wings. The eagle faces left and is enclosed in a circular border. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the top of the circle. DEC 2 7 1999 Mr. John M. Mitchell Vice President Renaissance Medical ™, LLC Division of SOMA Blue TM, Inc. P.O. Box 1447 1025 Broad Street Augusta, GA 30903 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Re: K993143 Vitality System™ Dated: December 8, 1999 Received: December 15, 1999 Unclassified/Procode: 78 LKY Dear Mr. Mitchell: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regult in requlatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours, CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {1}------------------------------------------------ 510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________ Device Name: Vitality System™ Indications for Use: The Vitality System consists of a manual vacuum pump, a cylinder, cushion inserts, constriction ring loader, constriction rings, and lubricant. The Vitality System's intended use is to manage erectile dysfunction by allowing the creation of a full erection suitable for sexual activity. This is accomplished through the use of the manual vacuum pump to remove air from the cylinder, creating vacuum pressure within the cylinder. Blood is thereby drawn into the penis, causing it to become erect. The constriction ring is then placed around the base of the erect penis to restrict the outflow of blood. When activity is complete, the ring is removed from the base of the " penis. This product is intended for over the counter use. ## (PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | Prescription Use (Per CFR 801.109) | OR | Over-The-Counter Use <span></span> | |------------------------------------|----|------------------------------------| |------------------------------------|----|------------------------------------| (Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devices | 510(k) Number | K993143/5001 | (Optional Format 1-2-96) | |---------------|--------------|--------------------------| |---------------|--------------|--------------------------|
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...