K993296 · Datex-Ohmeda, Inc. · KNT · Dec 15, 1999 · Gastroenterology, Urology
Device Facts
Record ID
K993296
Device Name
TRIP TONOMETRY CATHETER, 14F
Applicant
Datex-Ohmeda, Inc.
Product Code
KNT · Gastroenterology, Urology
Decision Date
Dec 15, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 876.5980
Device Class
Class 2
Intended Use
TRIP Tonometry Catheter, 14F is used for the determination of regional PCO2 (PrCO2) and intramucosal pH (pHi) of the gastric mucosal tissue when used as a gastrointestinal tract access device for connecting a Tonocap™ monitor (Regional and Airway capnometer) . The sampling line and biofilter built into the device serve as a means of connecting the catheter to the monitor and as transducer protector to prevent patient cross-contamination and monitor damage, respectively. It incorporates a second lumen used for feeding and/or decompression or aspiration of the contents of the stomach.
Device Story
TRIP Tonometry Catheter, 14F is a gastrointestinal access device used to measure regional gastric mucosal PCO2 (PrCO2) and intramucosal pH (pHi). The catheter connects to a Tonocap monitor via an integrated sampling line and biofilter, which protects the monitor and prevents cross-contamination. A second lumen allows for gastric feeding, decompression, or aspiration. Used in clinical settings (OR, ICU, ER) by healthcare professionals to monitor patients with suspected mesenteric ischemia. The device provides data to clinicians to assess tissue perfusion and metabolic status, aiding in clinical decision-making for critically ill patients.
Clinical Evidence
No clinical data provided; substantial equivalence based on device design and intended use.
Technological Characteristics
14F catheter with dual-lumen design; includes integrated sampling line and biofilter for transducer protection. Functions as a gastrointestinal access device for PCO2/pHi monitoring via connection to a Tonocap monitor. Materials and sterilization methods are consistent with standard gastrointestinal catheter requirements.
Indications for Use
Indicated for surgical, operating room, intensive care unit, emergency/trauma, and hospital patients with suspected mesenteric ischemia.
Regulatory Classification
Identification
A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).
Special Controls
*Classification.* (1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.
Reference Devices
Tonocap monitor
Related Devices
K980384 — TRIP TONOMETRY CATHETER, 18F · Datex-Engstrom, Inc. · May 1, 1998
K992181 — TRIP TONOMETRY CATHETER, 8F · Datex-Ohmeda, Inc. · Aug 24, 1999
K983366 — TRIP TONOMETRY CATHETER, 16F · Datex-Engstrom, Inc. · Dec 23, 1998
K052167 — DATEX-OHMEDA S/5 TONOMETRY MODULE, E TONO AND ACCESSORIES · GE Healthcare · Sep 8, 2005
K013704 — MEDIPLUS SINGLE USE GI MANOMETRY CATHETER · Mediplus , Ltd. · Aug 5, 2002
Submission Summary (Full Text)
{0}------------------------------------------------
and the control control of the control of the control of the control of the control of the contribution of the contribution of the contribution of the contribution of the con
Image /page/0/Picture/2 description: The image shows the logo for the Department of Health & Human Services - USA. The logo is circular, with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter of the circle. In the center of the circle is an abstract symbol that resembles an eagle or a bird in flight, composed of three curved lines.
DEC 1 5 1999
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Mr. Joel C. Kent FDA Official Correspondent Manager, Quality and Regulatory Affairs Datex-Ohmeda, Inc. Three Highwood Drive Tewksbury, MA 01876
Re: K993296 TRIP Tonometry Catheter, 14F Dated: September 28, 1999 Received: October 1, 1999 Regulatory Class: Il 21 CFR §876.5980/Procode: 78 KNT 21 CFR §868.1400/Procode: 73 CCK 21 CFR §868.1700/Procode: 73 CBR
Dear Mr. Kent:
We have reviewed vour Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895, A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Requlation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".
Sincerely yours,
CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{1}------------------------------------------------
Page 1 of 1
510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________ K993296
Device Name: TRIP Tonometry Catheter, 14F
Indications For Use:
TRIP Tonometry Catheter, 14F is used for the determination of regional PCO2 (PrCO2) and intramucosal pH (pHi) of the gastric mucosal tissue when used as a gastrointestinal tract access device for connecting a Tonocap™ monitor (Regional and Airway capnometer) . The sampling line and biofilter built into the device serve as a means of connecting the catheter to the monitor and as transducer protector to prevent patient cross-contamination and monitor damage, respectively. It incorporates a second lumen used for feeding and/or decompression or aspiration of the contents of the stomach.
It is indicated for use in surgical/operating room patients, intensive care unit patients , emergency/trauma patients and hospital patients with suspected mesenteric ischemia.
## (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use 1 (Per 21 CFR 801.109)
OR
Over-The-Counter Use _
(Optional Format 1-2-96)
(Division Sign-Off) (Division Sign-Off)
Division of Repreductive, Abdominal, ENT, and Radiological Device 510(k) Number .
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.