QJN · Laparoscopic Accessories, Esophageal Sizing

Gastroenterology, Urology · 21 CFR 876.5360 · Class 2

Overview

Product CodeQJN
Device NameLaparoscopic Accessories, Esophageal Sizing
Regulation21 CFR 876.5360
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

A laparoscopic gastrointestinal sizing tool is a prescription use device intended for laparoscopically measuring an extraluminal dimensional parameter of the indicated gastrointestinal organs.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Performance testing must demonstrate that the sizing tool performs as intended under anticipated conditions of use. Performance testing must include the following: (i) Trocar compatibility, which includes shaft bending force characterization; (ii) Joint strength tensile testing; (iii) Distal loop extension/retraction force characterization; (iv) Material selection analysis, which includes corrosion and visual inspection; and (v) Accuracy of the dimensional measurement. (2) Performance testing must support the sterility and/or reprocessing and shelf life of the patient-contacting components of the device. (3) The patient-contacting components of the device must be demonstrated to be biocompatible. (4) Labeling of the device must include the following: (i) A statement regarding metal allergies if the device is made from metallic components; (ii) Specific instructions for proper device use including information regarding the following: (A) Inspection of device prior to use; (B) Surgical access techniques or methodologies; (C) Instructions for avoiding structural damage to vagus nerve bundle; (D) Trocar compatibility; (E) Sizing methodology; and (F) Minimum and maximum dimensional parameters that the device is capable of measuring. (iii) Identification of the associated parent device with which the sizing tool has been demonstrated to be compatible; and (iv) An expiration date.

Recent Cleared Devices (2 of 2)

RecordDevice NameApplicantDecision DateDecision
K230089ETHICON LINX® Esophagus Sizing ToolTorax Medical, Inc.Feb 9, 2023SESE
K201035ETHICON Linx Esophagus Sizing ToolTorax Medical, Inc.Jul 9, 2020SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...