CUSTODIOL

K032794 · Dr. Franz Kohler Chemie GmbH · MSB · Apr 5, 2004 · Gastroenterology, Urology

Device Facts

Record IDK032794
Device NameCUSTODIOL
ApplicantDr. Franz Kohler Chemie GmbH
Product CodeMSB · Gastroenterology, Urology
Decision DateApr 5, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.5880
Device ClassClass 2
AttributesTherapeutic

Indications for Use

Custodiol HTK Solution is indicated for perfusion and flushing donor kidneys, livers, and hearts prior to removal from the donor or immediately after removal from the donor. The solution is left in the organ vasculature during hypothermic storage and transportation (not for continuous perfusion) to the recipient.

Device Story

Custodiol HTK Solution is a chemical solution used for organ preservation during transplant procedures. It functions by inactivating organ function through the withdrawal of extracellular sodium and calcium and intensive buffering using histidine/histidine HCl. This process prolongs the period organs can tolerate the interruption of blood and oxygen supply. The solution is characterized by low viscosity at low temperatures, facilitating rapid cooling during initial perfusion. It is intended for use by medical professionals in a clinical or surgical setting to prepare donor organs (kidneys, livers, hearts) for transport. By maintaining physiological conditions and reducing metabolism during cold storage, the solution helps preserve organ viability for the recipient.

Clinical Evidence

Evidence includes a small randomized clinical study and data from a major heart transplant center. Studies compared Custodiol HTK Solution against Celsior Solution and Viaspan Belzer UW Solution, evaluating survival rates and other outcome measures to demonstrate equivalent effectiveness.

Technological Characteristics

Solution containing electrolytes and buffering agents (histidine/histidine HCl). Components occur naturally in the body. Features low viscosity at low temperatures to ensure rapid flow rates during perfusion. Non-mechanical, chemical-based preservation.

Indications for Use

Indicated for perfusion and flushing of donor kidneys, livers, and hearts prior to or immediately after removal from the donor. Used during hypothermic storage and transport; not for continuous perfusion.

Regulatory Classification

Identification

An isolated kidney perfusion and transport system and accessories is a device that is used to support a donated or a cadaver kidney and to maintain the organ in a near-normal physiologic state until it is transplanted into a recipient patient. This generic type of device may include tubing, catheters, connectors, an ice storage or freezing container with or without bag or preservatives, pulsatile or nonpulsatile hypothermic isolated organ perfusion apparatus with or without oxygenator, and disposable perfusion set.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ APR - 5 2004 # 510(k) Summary # Custodiol® HTK Solution Common/Classification Name: Isolated Heart Perfusion and Transport System and Accessories, 21 CFR 876.5880 > Dr. Franz Köhler Chemie GmbH Postfach 1117 D-64659 Alsbach-Hähnlein Germany Contact: E. Schaffner, M.D. Prepared: September 5, 2003 #### LEGALLY MARKETED PREDICATE DEVICES A. For its indication for use, the Custodiol HTK Solution is substantially equivalent to the Celsior Cold Storage Solution, which was cleared by FDA as K991594 for the single indication of heart preservation. For its specific formulation and other physical and chemical characteristics, it is substantially equivalent to the currently marketed Custodiol product. #### B. DEVICE DESCRIPTION The HTK solution is intended for perfusion and flushing donor hearts prior to removal from the donor and for preserving the heart during hypothermic storage and transport to the recipient. HTK solution is based on the principle of inactivating organ function by withdrawal of extracellular sodium and calcium, together with intensive buffering of the extracellular space by means of histidine/histidine HCI, so as to prolong the period for which the organs will tolerate interruption of blood and oxygen supply. Only a small portion of the osmolality of the HTK solution is due to the sodium and potassium. The composition of HTK is similar to that of extracellular fluid. All of the components of the HTK solution occur naturally in the body. The HTK solution is relatively low in potassium concentration so that residual solution in the transplanted organ poses no danger to the recipient. This is particularly important in organs that take up relatively large amounts of the perfusate, which may find its way into the recipient's circulation. The HTK solution has a low viscosity, even at low temperatures. This characteristic assures rapid flow rates during initial perfusion, allowing the {1}------------------------------------------------ CO32794 20f 3 organ to be quickly cooled. #### C. INDICATIONS FOR USE Custodiol HTK Solution is indicated for perfusion and flushing donor kidneys, livers, and hearts prior to removal from the donor or immediately after removal from the donor. The solution is left in the organ vasculature during hypothermic storage and transportation (not for continuous perfusion) to the recipient. #### SUBSTANTIAL EQUIVALENCE SUMMARY D. The Custodiol HTK Solution is a medical device, and it has a similar indications for use as the legally marketed predicate devices. While the indications for use statement is not identical to those of the predicate devices, the intended use is clearly the same. The Custodiol HTK Solution has the same technological characteristics as the predicate devices. However, the characteristics may not be sufficiently precise to assure equivalence through a point by point comparison. Therefore, extensive clinical and animal data has been collected by the sponsor and others. The performance data clearly demonstrates equivalence. ### TECHNOLOGICAL CHARACTERISTICS ui Both the Custodiol HTK Solution and the predicate device are solutions containing electrolytes, buffering agents, and other materials occurring naturally in the body. Both solutions are intended to reduce metabolism and preserve physiological conditions of explanted organs and tissue during cold storage. ### E. TESTING Several clinical studies have been reported that compared the performance of Custodiol HTK Solution with the Celsior Solution, the Viaspan Belzer UW Solution, and others. These studies have compared survival rates and other outcome measures. The primary evidence for the equivalence in effectiveness of Custodiol to that of Celsior has come from a small randomized clinical study and from the extensive experience of the largest heart transplant center in the world. #### CONCLUSIONS ு. The clinical and other performance data amply demonstrate that Custodiol performs as well as the predicate device. This pre-market {2}------------------------------------------------ submission demonstrates Substantial Equivalence as defined and understood in the Federal Food Drug and Cosmetic Act and various guidance documents issued by the Center for Devices and Radiological Health. {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo features a stylized eagle with three wavy lines representing the feathers. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 APR - 5 2004 Dr. Franz Köhler Chemie GmbH c/o T. Whit Athey, Ph.D. Senior Consultant The Health Policy Resources Group, LLC 2305 Gold Mine Road, Suite 200 BROOKEVILLE MD 20833-2233 Re: K032794 Trade/Device Name: Custodiol® HTK Solution for Perfusion and Flushing of Donor Hearts Regulation Number: 21 CFR §876.5880 Regulation Name: Isolated kidney perfusion and transport system and accessories Regulatory Class: II Product Code: 78 MSB Dated: January 21, 2004 Received: January 21, 2004 Dear Dr. Athey: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirement; as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the clectronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050. {4}------------------------------------------------ This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of the letter: | 8xx. 1xxx | (301) 594-4591 | |----------------------------------|----------------| | 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 | | 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 | | 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 | | Other | (301) 594-4692 | Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrt/dsma/dsmamain.html. Sincerely yours, Nancy C. Brogdon Nancy C. Brogdon Director, Division of Reproductive, Abdominal and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure Page 2 {5}------------------------------------------------ ## STATEMENT OF INDICATIONS FOR USE 510(k) Number (if known): Device Name: Custodiol HTK Solution Indications For Use: Custodiol HTK Solution is indicated for perfusion and flushing donor kidneys, livers, and hearts prior to removal from the donor or immediately after removal from the donor. The solution is left in the organ vasculature during hypothermic storage and transportation (not for continuous perfusion) to the recipient. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use X (Per 21 CFR 801.109) OR Over-The-Counter Use ___________ NancyC basgodon (Division Sign-Off) Division of Reproductive. Abe ominal, and Radiological Devic 510(k) Number 000050
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...