CORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900

K063061 · Viasys Medsystems · KNT · Apr 2, 2007 · Gastroenterology, Urology

Device Facts

Record IDK063061
Device NameCORTRAK ENTERAL ACCESS DEVICE, MODEL 20-0900
ApplicantViasys Medsystems
Product CodeKNT · Gastroenterology, Urology
Decision DateApr 2, 2007
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.5980
Device ClassClass 2

Indications for Use

The CORTRAK™ System is an electrical device designed to aid qualified operators in the placement of VIASYS MedSystems feeding tubes of 8 FR or greater into the stomach or small bowel of patients requiring enteral feeding, Prior to commencing the delivery of food, confirmation of correct tube placement by X-ray or acceptable hospital protocol is required.

Device Story

CORTRAK™ Enteral Access Device aids clinicians in placing feeding tubes (8 FR or larger) into stomach or small bowel. System uses electrical signals to track tube tip position during insertion. Provides real-time visual feedback to operator to assist navigation. Device intended for use by qualified operators in clinical settings. Output allows clinician to monitor tube path; however, final confirmation of correct placement via X-ray or standard hospital protocol remains mandatory before initiating enteral feeding. Benefits include potential reduction in malposition risks during bedside tube placement.

Clinical Evidence

No clinical data provided in the document; substantial equivalence determination based on 510(k) review process.

Technological Characteristics

Electrical device for enteral feeding tube placement. Supports tubes 8 FR or greater. Operates via electrical signal tracking for tip localization. Intended for clinical use by qualified operators.

Indications for Use

Indicated for patients requiring enteral feeding who need placement of VIASYS MedSystems feeding tubes (8 FR or greater) into the stomach or small bowel.

Regulatory Classification

Identification

A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).

Special Controls

*Classification.* (1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "U.S. Department of Health & Human Services" written around the perimeter. Inside the circle is an abstract image of an eagle with its wings spread. The eagle is facing to the right. Food and Drug Administration 9200 Corporate Blvd. Rockville MD 20850 Ms. Stephanie Wasielewski VP, Regulatory Affairs/Quality VIASYS MedSystems 100 Chaddick Drive WHEELING IL 60090 - 2 2007 Re: K063061 Trade/Device Name: CORTRAK™ Enteral Access Device Regulation Number: 21 CFR §876.5980 Regulation Name: Gastrointestinal tube and accessories Regulatory Class: II Product Code: KNT Dated: March 8, 2007 Received: March 9, 2007 Dear Ms. Wasielewski: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Image /page/0/Picture/10 description: The image is a black and white circular logo. The logo contains the text "1806-1906" at the top, "FDA" in the center, and "Centennial" at the bottom. There are three stars below the word "Centennial". The logo is surrounded by a circular border. Preaching and Promoting Public Health {1}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter: | 21 CFR 876.xxxx | (Gastroenterology/Renal/Urology) | 240-276-011 | |-----------------|----------------------------------|-------------| | 21 CFR 884.xxxx | (Obstetrics/Gynecology) | 240-276-011 | | 21 CFR 892.xxxx | (Radiology) | 240-276-012 | | Other | | 240-276-010 | Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html Sincerely yours, Nancy C. Brogdon Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## 510(k) Number: ・ ・ KX4306 | ## DEVICE NAME: CORTRAK ## INDICATIONS FOR USE The CORTRAK™ System is an electrical device designed to aid qualified operators in the placement of VIASYS MedSystems feeding tubes of 8 FR or greater into the stomach or small bowel of patients requiring enteral feeding, Prior to commencing the delivery of food, confirmation of correct tube placement by X-ray or acceptable hospital protocol is required. ## Concurrence of CDRH, Office of Device Evaluation (ODE) Nancy C. Brogdon (Division Sign-Off) Division of Reproductive, Abdominal, and Radiological Devices 510(k) Number_ Prescription Use (Per 21 CFR 801.109)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...