FJS · Catheter, Peritoneal, Long-Term Indwelling

Gastroenterology, Urology · 21 CFR 876.5630 · Class 2

Overview

Product CodeFJS
Device NameCatheter, Peritoneal, Long-Term Indwelling
Regulation21 CFR 876.5630
Device ClassClass 2
Review PanelGastroenterology, Urology
ImplantYes

Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Recent Cleared Devices (20 of 48)

Showing 20 most recent of 48 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K213602Argyle Peritoneal Dialysis Cathetor and Kit, Ritus Peritoneal Dialysis Catheter Tunneling Tool KitCovidien, LLCJan 14, 2022SESE
K180485Argyle Peritoneal Dialysis Catheter and Kits, Argyle Presternal Peritoneal Dialysis Catheter and Kits, Argyle Peritoneal Dialysis Accessory Two Part Titanium Luer Adapter, Argyle Adult Peritoneal Dialysis Accessory Titanium Catheter ExtenderCovidien, LLCJul 27, 2018SESK
K130441FALLER STYLETMedionics International, Inc.Apr 19, 2013SESE
K121383PS X SERIES (BASIC COMPONENTS AND CATHETER), PD X SERIES (CATHETER WITH ALL COMPONENTS)Medical Components, Inc.Sep 5, 2012SESK
K120130FALLER TROCARMedigroup, Inc.May 21, 2012SESE
K113354VETA PERITONEAL DIALYSIS CATHETERPfm Medical, Inc.Mar 13, 2012SESK
K071167FLEX-NECK EXXTENDED PERITONEAL DIALYSIS CATHETER AND ACCESSORIES, MODEL CF-5560Medigroup, Inc.Aug 31, 2007SESK
K070730FLEX-NECK ARC CATHETERMedigroup, Inc.Jul 3, 2007SESK
K060897EMBEDDING TOOL, MODEL TE-1000Medigroup, Inc.Jul 18, 2006SESE
K053123PD CATHMed-Conduit, Inc.Mar 29, 2006SESE
K031351FLEX-NECK PD CATHETER, INFANTMedigroup, Inc.Sep 17, 2003SESE
K012502MEDIGROUP CATHETER EXTENDER/REPAIR KITJanin Group, Inc.Feb 4, 2002SESE
K013017MEDIGROUP KEY TUBEJanin Group, Inc.Dec 6, 2001SESE
K993149PERITONEAL DIALYSIS CATHETERS AND ADAPTERSMedionics International, Inc.Apr 28, 2000SESE
K991042ASH ADVANTAGE PERITONEAL CATHETERJanin Group, Inc.Jun 25, 1999SESE
K970159FLEX-NECK PD CATHETERJanin Group, Inc.Sep 5, 1997SESE
K961392ANTIMICROBIAL PERITONEAL DIALYSIS COIL CATHETER WITH SPI-ARGENT IISil-Med Corp.Jul 18, 1997SESE
K950042SWAN NECK PRESTERNAL PERITONEAL DIALYSIS CATHETERAccurate Surgical Instruments Co.Dec 15, 1995SESE
K934610CATH DOME PD- WATER RESISTANT COVER FOR INDWELLING PERITONEAL DIALYSIS CATHETERS AND TRANSFER SETSTabex Industries, Inc.Sep 23, 1994SESE
K930175CATH BELT PD CATHETER AND TRANSFER SET HOLDERTabex Industries, Inc.Jun 23, 1994SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...