Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5520](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5520) → FAH — Dilator, Urethral, Mechanical

# FAH · Dilator, Urethral, Mechanical

_Gastroenterology, Urology · 21 CFR 876.5520 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH

## Overview

- **Product Code:** FAH
- **Device Name:** Dilator, Urethral, Mechanical
- **Regulation:** [21 CFR 876.5520](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5520)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

A urethral dilator is a device that consists of a slender hollow or solid instrument made of metal, plastic, or other suitable material in a cylindrical form and in a range of sizes and flexibilities. The device may include a mechanism to expand the portion of the device in the urethra and indicate the degree of expansion on a dial. It is used to dilate the urethra. This generic type of device includes the mechanical urethral dilator, urological bougies, metal or plastic urethral sound, urethrometer, filiform, and filiform follower.

## Classification Rationale

(1) Class II (special controls). Except when it is a mechanical urethral dilator, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the urethrometer, urological bougie, filiform and filiform follower, and metal or plastic urethral sound. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Special Controls

*Classification.* (1) Class II (special controls). Except when it is a mechanical urethral dilator, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the urethrometer, urological bougie, filiform and filiform follower, and metal or plastic urethral sound. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Recent Cleared Devices (4 of 4)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K933957](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH/K933957.md) | DILATING URETHRAL SOUND | Cook Urological, Inc. | Nov 17, 1993 | SESE |
| [K902370](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH/K902370.md) | MODIFIED PROSTATIC URETHROPLASTY BALLOON CATHETER | Boston Scientific Corp | Aug 17, 1990 | SESE |
| [K902124](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH/K902124.md) | DOWD CATHETER | Boston Scientific Corp | Aug 9, 1990 | SESE |
| [K831384](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH/K831384.md) | COAXIAL BALLOON URETHRAL DILATOR | Thomas J. Fogarty, M.D. | Jul 26, 1983 | SESE |

## Top Applicants

- Boston Scientific Corp — 2 clearances
- Cook Urological, Inc. — 1 clearance
- Thomas J. Fogarty, M.D. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/FAH)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com