Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5130](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5130) → EZC — Catheter, Coude

# EZC · Catheter, Coude

_Gastroenterology, Urology · 21 CFR 876.5130 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC

## Overview

- **Product Code:** EZC
- **Device Name:** Catheter, Coude
- **Regulation:** [21 CFR 876.5130](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5130)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudé catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).

## Classification Rationale

(1) Class II (performance standards).(2) Class I for the ureteral stylet (guidewire), stylet for gastrourological catheter, ureteral catheter adapter, ureteral catheter connector, and ureteral catheter holder. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Recent Cleared Devices (7 of 7)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K222279](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K222279.md) | Rusch Intermittent Urethral Catheters | Teleflex Medical | Aug 29, 2022 | SESE |
| [K173596](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K173596.md) | Rusch Intermittent Urethral Catheters | Teleflex Medical | Jan 29, 2018 | SESE |
| [K946282](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K946282.md) | UNIVERSAL URETHRAL CATHETER | Louisville Laboratories, Inc. | Mar 31, 1995 | SESE |
| [K913341](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K913341.md) | BARD(R) COUDE TIP TEMPERATURE SENSING CATHETER | C.R. Bard, Inc. | Jan 27, 1992 | SESE |
| [K910846](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K910846.md) | BARD LATEX URINARY CATHETERS DRAINS- DESIGNS MODIF | C.R. Bard, Inc. | Aug 16, 1991 | SEKD |
| [K910197](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K910197.md) | HYDROGEL-COATED URETHRAL CATHETERS AND DRAINS | C.R. Bard, Inc. | Aug 9, 1991 | SESE |
| [K910195](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC/K910195.md) | BARD HYDROGEL-COATED FOLEY CATHETERS | C.R. Bard, Inc. | Aug 9, 1991 | SESE |

## Top Applicants

- C.R. Bard, Inc. — 4 clearances
- Teleflex Medical — 2 clearances
- Louisville Laboratories, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EZC)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).