Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5130](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5130) → EYC — Catheter, Upper Urinary Tract

# EYC · Catheter, Upper Urinary Tract

_Gastroenterology, Urology · 21 CFR 876.5130 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC

## Overview

- **Product Code:** EYC
- **Device Name:** Catheter, Upper Urinary Tract
- **Regulation:** [21 CFR 876.5130](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5130)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudé catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).

## Classification Rationale

(1) Class II (performance standards).(2) Class I for the ureteral stylet (guidewire), stylet for gastrourological catheter, ureteral catheter adapter, ureteral catheter connector, and ureteral catheter holder. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Recent Cleared Devices (5 of 5)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K200757](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC/K200757.md) | Foley Catheter with Temperature Sensor | Deroyal Industries, Inc. | Oct 15, 2020 | SESE |
| [K061918](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC/K061918.md) | FOLEY CATHETERS WITH TEMPERATURE PROBE | GE Healthcare | Aug 18, 2006 | SESE |
| [K041416](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC/K041416.md) | EXAC-TEMP FOLEY CATHETER AND CLINI-TEMP FOLEY CATHETER | Deroyal | Jul 2, 2004 | SESE |
| [K925790](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC/K925790.md) | EXAC-TEMP & CLINI-TEMP FOLEY CATHETER'S | Deroyal Industries, Inc. | May 17, 1993 | SESE |
| [K890310](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC/K890310.md) | STERILE FOLEY CATHETER | Kosan Far East Ent. , Ltd. | Nov 30, 1989 | SESE |

## Top Applicants

- Deroyal Industries, Inc. — 2 clearances
- Deroyal — 1 clearance
- GE Healthcare — 1 clearance
- Kosan Far East Ent. , Ltd. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC](https://fda.innolitics.com/submissions/GU/subpart-f%E2%80%94therapeutic-devices/EYC)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com