BIODERM EID MALE EXTERNAL INCONTINENCE DEVICE

K963950 · Bioderm, Inc. · EXI · Jan 10, 1997 · Gastroenterology, Urology

Device Facts

Record IDK963950
Device NameBIODERM EID MALE EXTERNAL INCONTINENCE DEVICE
ApplicantBioderm, Inc.
Product CodeEXI · Gastroenterology, Urology
Decision DateJan 10, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.5250
Device ClassClass 1
AttributesTherapeutic

Indications for Use

The BioDerm® EID® is an external male catheter intended for the management of urinary incontinence in males. It facilitates urine drainage into a urine collection bag.

Device Story

External male catheter; manages urinary incontinence; facilitates urine drainage into collection bag. Device applied externally to male anatomy; non-latex, self-adhesive design. Used in clinical or home settings; operated by patient or caregiver. Provides passive drainage path for urine; improves patient hygiene and comfort by containing incontinence.

Clinical Evidence

Bench testing only; biocompatibility testing performed to confirm safety for intended use.

Technological Characteristics

Non-latex, self-adhesive external catheter. Form factor designed for male anatomy. Passive drainage mechanism.

Indications for Use

Indicated for males with urinary incontinence requiring urine drainage into a collection bag.

Regulatory Classification

Identification

A urine collector and accessories is a device intended to collect urine. The device and accessories consist of tubing, a suitable receptacle, connectors, mechanical supports, and may include a means to prevent the backflow of urine or ascent of infection. The two kinds of urine collectors are:(1) A urine collector and accessories intended to be connected to an indwelling catheter, which includes the urinary drainage collection kit and the closed urine drainage system and drainage bag; and (2) A urine collector and accessories not intended to be connected to an indwelling catheter, which includes the corrugated rubber sheath, pediatric urine collector, leg bag for external use, urosheath type incontinence device, and the paste-on device for incontinence.

Special Controls

*Classification* —(1)*Class II (special controls) for a urine collector and accessories intended to be connected to an indwelling catheter.* The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.(2) *Class I (general controls).* For a urine collector and accessories not intended to be connected to an indwelling catheter, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Predicate Devices

Submission Summary (Full Text)

{1} K963950 BIODERM JAN 10 1997 # EXHIBIT 10.1: BioDerm® EID® MALE EXTERNAL INCONTINENCE DEVICE ## 510(k) SUMMARY Submitted by: Eric Flam, Ph.D. NTL Associates, Inc. East Brunswick, NJ 08816 (908)390-5656 October 1, 1996 Device Name: BioDerm® EID® MALE EXTERNAL INCONTINENCE DEVICE (a) **Indications for Use** The BioDerm® EID® is an external male catheter intended for the management of urinary incontinence in males. It facilitates urine drainage into a urine collection bag. (b) **Biocompatibility** The results of the biocompatibility tests show the device to be safe for its intended purpose. (c) **Substantial Equivalence** The BioDerm® EID® male external catheter is substantially equivalent to the Hollister PolyTech™, non-latex, self-adhesive urinary external catheter predicate device. BioDerm, Inc. • 11300 49th St. N., Suite B, Clearwater, FL 34622 • 813-573-2866 • Fax 813-573-3448
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...