SPHINCTEROTOME
K973826 · Boston Scientific Corp · KNS · Dec 5, 1997 · Gastroenterology, Urology
Device Facts
| Record ID | K973826 |
| Device Name | SPHINCTEROTOME |
| Applicant | Boston Scientific Corp |
| Product Code | KNS · Gastroenterology, Urology |
| Decision Date | Dec 5, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.4300 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Microvasive® Needle Knife Sphincterotome is indicated for use in transendoscopic sphincterotomy of the Papilla of Vater and/or the Sphincter of Oddi. The Microvasive Needle Knife can also be used to cannulate and inject contrast medium.
Device Story
The Microvasive Needle Knife Sphincterotome is an endoscopic electrosurgical accessory used during ERCP procedures. Operated by a physician, the device is inserted transendoscopically to perform sphincterotomy of the Papilla of Vater or Sphincter of Oddi. It also facilitates cannulation and contrast medium injection. The device functions via electrosurgical energy to cut tissue. It is used in clinical settings where ERCP is performed. By enabling precise sphincterotomy and access to the biliary/pancreatic ducts, the device assists in therapeutic interventions, potentially benefiting patients requiring biliary or pancreatic drainage or stone removal.
Clinical Evidence
No clinical data. Bench testing only, including biocompatibility assessment of patient- and fluid-contact materials and performance testing to verify safety and functionality.
Technological Characteristics
Electrosurgical sphincterotome; sterile, single-use device. Materials: biocompatible patient-contact components. Sterilization: ethylene oxide gas per AAMI protocol. Packaging: tray with Tyvek lid. Energy source: external electrosurgical unit.
Indications for Use
Indicated for patients undergoing transendoscopic sphincterotomy of the Papilla of Vater and/or the Sphincter of Oddi, and for cannulation and contrast medium injection during ERCP. Contraindicated for patients with contraindications specific to ERCP and endoscopic sphincterotomy.
Regulatory Classification
Identification
An endoscopic electrosurgical unit and accessories is a device used to perform electrosurgical procedures through an endoscope. This generic type of device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self-opening rigid snare, flexible suction coagulator electrode, patient return wristlet, contact jelly, adaptor to the cord for transurethral surgical instruments, the electric cord for transurethral surgical instruments, and the transurethral desiccator.
Predicate Devices
- Microvasive Rapid Exchange Sphincterotome
- Ultratome XL Triple Lumen Sphincterotome
Related Devices
- K201121 — Sphincterotome · Hangzhou AGS MedTech Co., Ltd. · Feb 5, 2021
- K251104 — SureTome SW Sphincterotome with DomeTip · Wilson-Cook Medical · Sep 29, 2025
- K172665 — Classic Cotton Cannulatome®, CannulaTome II® Double Lumen Sphincterotome, Cotton CannulaTome II® PC, UTS® Ultra Taper Sphincterotome, Tri-Tome pc® Triple Lumen Sphincterotome, Howell D.A.S.H.® Sphincterotome with DomeTip®, Billroth II Sphincterotome, Soehendra® BII Sphincterotome, Models ACU-1 and ACU-1-VL active cords · Wilson-Cook Medical Inc./Cook Endoscopy · May 24, 2018
- K242192 — Disposable Sphincterotome · Beijing Zksk Technology Co., Ltd. · Feb 6, 2025
- K222421 — Sphincterotome · Hangzhou AGS MedTech Co., Ltd. · May 3, 2023
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows handwritten text that appears to be a combination of letters and numbers. The first line reads 'K973826', and the second line reads '1 of 2'. The handwriting is somewhat rough, giving the text a casual and informal appearance.
# SECTION 9 510(K) SUMMARY
DEC - 5 1997
## FOI RELEASABLE
Pursuant to §513(i)(3)(A) of the Food, Drug, and Cosmetic Act, Boston Scientific Corporation is required to submit with this Premarket Notification "...adequate summary of any information respecting safety and effectiveness or state that such information will be made available upon request of any person." Boston Scientific Corporation chooses to submit a summary of information respecting safety and effectiveness.
| ➤ COMMON/USUAL NAMES: | Sphincterotome | | |
|---------------------------------------------------|----------------------------------------------------------------------------------|--------|------------|
| ➤ TRADE/PROPRIETARY NAME: | None at this time | | |
| ➤ CLASSIFICATION NAME &<br>DEVICE CLASSIFICATION: | Class II | | |
| | Name | Number | 21 CFR Ref |
| | Endoscopic Electrosurgical<br>Unit and Accessories. | 78 KNS | 876.4300 |
| ➤ DEVICE PANEL/BRANCH: | Gastroenterology-Urology (GU)<br>Gastro-Renal (GRDB) | | |
| ➤ OWNER/OPERATOR: | Boston Scientific Corporation<br>One Boston Scientific Place<br>Natick, MA 01760 | | |
| ➤ CONTACT PERSON: | Daniel J. Dillon, Senior Regulatory Affairs Specialist | | |
#### INDICATIONS FOR USE
The Microvasive® Needle Knife Sphincterotome is indicated for use in transendoscopic sphincterotomy of the Papilla of Vater and/or the Sphincter of Oddi.
#### Contraindications
Contraindications for this device are those specific to endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES).
{1}------------------------------------------------
#### COMPLICATIONS
Possible complications include, but may not be limited to: pancreatitis; perforation; hemorrhage, hematoma, cholangitis; stone impaction; septicemia/infection; and allergic reaction to contrast medium
## SUBSTANTIAL EQUIVALENCE
Boston Scientific Corporation believes that the Microvasive® Needle Knife Sphincterotome is substantially .equivalent to the currently-marketed Microvasive® Rapid Exchange Sphincterotome and Ultratome XLTM Triple Lumen Sphincterotome.
### Performance Characteristics
Laboratory testing regarding characteristics was performed on the Microvasive® Needle Knife Sphincterotome to verify its safety and performance. A biocompatibility assessment was performed on the patient- and fluid-contact materials of the Microvasive® Needle Knife Sphincterotome with satisfactory results.
#### Packaging, Sterilization, And Pyrogenicity
The Microvasive® Needle Knife Sphincterotome will be sterile in a tray sealed with a Tyvek lid. The Microvasive® Needle Knife Sphincterotome will be sterilized using ethylene oxide gas using the AAMI protocol for ethylene oxide sterilization. Pyrogenicity testing will be performed on a periodic basis to monitor bacterial endotoxin levels.
#### CONCLUSION
Boston Scientific Corporation believes that Microvasive® Needle Knife Sphincterotome is substantially equivalent to the currently-marketed Microvasive® Rapid Exchange Sphincterotome and Ultratome XLTM Triple Lumen Sphincterotome. A comparison of the descriptive characteristics of these products demonstrate the Microvasive® Needle Knife Sphincterotome is equivalent in its indications for use, while being very similar in design and materials. In addition, Boston Scientific Corporation has presented laboratory testing and biocompatibility information. The information presented provides assurance that the Microvasive® Needle Knife Sphincterotome will meet the minimum requirements that are considered acceptable for its intended use.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular emblem with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is a stylized image of three human profiles facing right, stacked on top of each other.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC - 5 1997
Mr. Daniel J. Dillon Senior Regulatory Affairs Specialist Boston Scientific Corporation One Boston Scientific Place Natick, Massachusetts 01760-1537
Re: K973826 Microvasive® Needle Knife Sphincterotome Dated: October 3, 1997 Received: October 7, 1997 Regulatory class: II 21 CFR §876.4300/Product code 78 KNS
Dear Mr. Dillon:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic OS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus. permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807,97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours.
h. William Yu
Lillian Yin, Ph.D. Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
{3}------------------------------------------------
510(k) Number:
Fo Be Determined K973826
Device Name:
Microvasive® Needle Knife Sphincterotome
Indication for Use:
The Microvasive® Needle Knife Sphincterotome is indicated for use in transendoscopic sphincterotomy of the Papilla of Vater and/or the Sphincter of Oddi. The Microvasive Needle Knife can also be used to cannulate and inject contrast medium.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Robert R. Satting/
(Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devices 510(k) Number
*Prescription Use*
(Per 21 CFR 801.109)
OR
Over-The-Counter Use_