Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart E — Surgical Devices](/submissions/GU/subpart-e%E2%80%94surgical-devices) → [21 CFR 876.4480](/submissions/GU/subpart-e%E2%80%94surgical-devices/876.4480) → FFK — Lithotriptor, Electro-Hydraulic

# FFK · Lithotriptor, Electro-Hydraulic

_Gastroenterology, Urology · 21 CFR 876.4480 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK

## Overview

- **Product Code:** FFK
- **Device Name:** Lithotriptor, Electro-Hydraulic
- **Regulation:** [21 CFR 876.4480](/submissions/GU/subpart-e%E2%80%94surgical-devices/876.4480)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

An electrohydraulic lithotriptor is an AC-powered device used to fragment urinary bladder stones. It consists of a high voltage source connected by a cable to a bipolar electrode that is introduced into the urinary bladder through a cystoscope. The electrode is held against the stone in a water-filled bladder and repeated electrical discharges between the two poles of the electrode cause electrohydraulic shock waves which disintegrate the stone.

## Classification Rationale

Class II. The special control for this device is FDA's “Guidance for the Content of Premarket Notifications for Intracorporeal Lithotripters.”

## Special Controls

The special control for this device is FDA's “Guidance for the Content of Premarket Notifications for Intracorporeal Lithotripters.”

## Recent Cleared Devices (20 of 61)

Showing 20 most recent of 61 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K243032](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K243032.md) | EHL Probe (SCDG-AS); EHL Probe (SCDG-BS); EHL Probe (SCDG-CS) | Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. | Mar 21, 2025 | SESE |
| [K242888](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K242888.md) | Electrohydraulic Lithotriptor (TCS-B3-II) | Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. | Mar 21, 2025 | SESE |
| [K230488](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K230488.md) | EL27-Compact; Sterile EHL-Probes | Walz Elektronik GmbH | Aug 31, 2023 | SESE |
| [K202813](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K202813.md) | URO-TOUCH 9 French Probe | Northgate Technologies, Inc. | Jun 14, 2021 | SESE |
| [K191124](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K191124.md) | Swiss LithoClast Trilogy | E.M.S Electro Medical Systems S.A | May 29, 2019 | SESE |
| [K162119](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K162119.md) | UreTron PF Series Probe | Med-Sonics Corp. | Aug 29, 2016 | SESE |
| [K160198](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K160198.md) | UreTron MultiProbe Lithotripter System | Med-Sonics Corp. | Feb 23, 2016 | SESE |
| [K132795](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K132795.md) | CYBERWAND STERILE PROBE SET | Cybersonics, Inc. | Nov 26, 2013 | SESE |
| [K130368](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K130368.md) | AUTOLITH TOUCH; URO TOUCH | Northgate Technologies, Inc. | Nov 15, 2013 | SESE |
| [K123038](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K123038.md) | SWISS LITHOBREAKER | E.M.S Electro Medical Systems S.A | Jan 16, 2013 | SESE |
| [K120303](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K120303.md) | CYBERWAND DUAL ACTION ULTRASONIC LITHOTRIPSY SYSTEM | Cybersonics, Inc. | Jun 5, 2012 | SESE |
| [K111058](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K111058.md) | URETRON MODEL URT | Med-Sonics Corp. | Mar 30, 2012 | SESE |
| [K102169](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K102169.md) | CYBERWAND LITHOTRIPTER | Cybersonics, Inc. | Aug 30, 2010 | SESE |
| [K092033](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K092033.md) | VIBROLITH AND VIBROLITH PLUS  INTRACORPOREAL LITHOTRIPTOR | Elmed USA | Apr 30, 2010 | SESE |
| [K072422](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K072422.md) | CYBERWAND STERILE PADS, MODEL: CW-RBPBX | Cybersonics, Inc. | Oct 24, 2007 | SESE |
| [K062475](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K062475.md) | LMA STONEBREAKER DEVICE; PROBE SIZE 1.0MM, 1.6MM, 2.0MM | The Laryngeal Mask Co., Ltd. | May 9, 2007 | SESE |
| [K052135](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K052135.md) | CYBERSONICS CYBERWAND DUAL PROBE LITHOTRIPTER | Cybersonics, Inc. | Dec 20, 2005 | SESE |
| [K011911](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K011911.md) | SUCTION PUMP FOR INTRACORPOREAL ULTRASOUND LITHOTRIPTER AND ACCESSORIES, MODEL 2207.XXX | Richard Wolf Medical Instruments Corp. | Sep 17, 2001 | SESE |
| [K011848](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K011848.md) | CIRCON AEH-4 ELECTROHYDRAULIC LITHOTRIPSY PROBE | Circon Video | Sep 11, 2001 | SESE |
| [K012445](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK/K012445.md) | EMS SWISS LITHOCLAST MASTER (A.K.A. SWISS LITHOCLAST ULTRA) | Electro Medical Systems SA | Aug 24, 2001 | SESE |

## Top Applicants

- Northgate Technologies, Inc. — 11 clearances
- Cybersonics, Inc. — 5 clearances
- Northgate Research, Inc. — 5 clearances
- Electro Medical Systems SA — 4 clearances
- Richard Wolf Medical Instruments Corp. — 4 clearances

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK](https://fda.innolitics.com/submissions/GU/subpart-e%E2%80%94surgical-devices/FFK)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
