ESW · Prosthesis, Esophageal

General, Plastic Surgery · 21 CFR 878.3610 · Class 2

Overview

Product CodeESW
Device NameProsthesis, Esophageal
Regulation21 CFR 878.3610
Device ClassClass 2
Review PanelGeneral, Plastic Surgery
ImplantYes

Identification

An esophageal prosthesis is a rigid, flexible, or expandable tubular device made of a plastic, metal, or polymeric material that is intended to be implanted to restore the structure and/or function of the esophagus. The metal esophageal prosthesis may be uncovered or covered with a polymeric material. This device may also include a device delivery system.

Classification Rationale

Class II. The special control for this device is FDA's “Guidance for the Content of Premarket Notification Submissions for Esophageal and Tracheal Prostheses.”

Special Controls

The special control for this device is FDA's “Guidance for the Content of Premarket Notification Submissions for Esophageal and Tracheal Prostheses.”

Recent Cleared Devices (20 of 59)

Showing 20 most recent of 59 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253327HANAROSTENT Esophagus Upper (CCC)M.I.Tech Co., Ltd.Oct 30, 2025SESE
K243619Niti-S Esophageal Stent; Esophageal TTS StentTaewoong Medical Co., Ltd.Oct 30, 2025SESE
K251265Resilience Fully Covered Esophageal Stent SystemMerit Medical Systems, Inc.Jul 23, 2025SESE
K233939Ultraflex Esophageal NG Stent System; WallFlex Esophageal Stent SystemBoston ScientificApr 29, 2024SESE
K233837Agile Esophageal Stent SystemBoston Scientific CorporationApr 4, 2024SESE
K240522Esophageal TTS StentTaewoong MedicalMar 22, 2024SESE
K223266Hilzo Esophageal StentsThoracent, Inc.Jan 16, 2024SESE
K221482Esophageal TTS StentTaewoong Medical Co., Ltd.Jun 22, 2022SESE
K211960Agile Esophageal OTW Stent SystemBoston Scientific CorporationNov 22, 2021SESE
K213251HANAROSTENT Esophagus Asymmetric (CCC)M.I.Tech Co., Ltd.Nov 18, 2021SESE
K211706Esophageal TTS StentTaewoong Medical Co., Ltd.Oct 8, 2021SESE
K201160HANAROSTENT Esophagus (CCC), HANAROSTENT Esophagus (NCN)M.I.Tech Co., Ltd.Jul 23, 2021SESE
K200860HANAROSTENT Esophagus TTS (CCC), HANAROSTENT Esophagus TTS (NCN)M.I.Tech Co., Ltd.May 20, 2020SESE
K182910Segmented Esophageal Stent SystemMicro-Tech (Nanjing) Co., Ltd.May 29, 2019SESE
K180144Agile Esophageal Stent SystemBoston Scientific CorporationSep 21, 2018SESE
K172813Esophageal Stent SystemMicro-Tech (Nanjing) Co., Ltd.May 18, 2018SESE
K162717Evolution Esophageal Stent System – Partially CoveredCook Ireland, Ltd.Dec 21, 2016SESE
K130004ULTRAFLEX ESOPHAGEAL NG STENT SYSTEMBoston Scientific CorporationDec 6, 2013SESE
K123205ESOPHAGEAL TTS STENTTaewoong Medical Co., Ltd.Oct 9, 2013SESE
K120983ULTRAFLEX ESOPHAGEAL NG STENT SYSTEMBoston Scientific CorporationMay 2, 2012SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...