AESOP SYSTEM AND ACCESSORIES
Device Facts
| Record ID | K960655 |
|---|---|
| Device Name | AESOP SYSTEM AND ACCESSORIES |
| Applicant | Computer Motion, Inc. |
| Product Code | GCJ · Gastroenterology, Urology |
| Decision Date | May 3, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
Indications for Use
The intended use of the AESOP System is a robotic computer driven system whose function is to hold and position a laparoscope. It is indicated for use in all forms of laparoscopic surgery. A few examples are cholecystectomy, laparoscopic hernia repair, and laparoscopic appendectomy.
Device Story
Robotic computer-driven system; holds and positions laparoscope during laparoscopic surgery. Operated by surgeon via hand, foot, or voice control. Voice control utilizes self-contained, speaker-dependent speech recognition system to translate verbal commands into positioning movements. System replaces manual holding of laparoscope; provides stable, surgeon-controlled visualization. Used in operating room environment.
Clinical Evidence
Bench testing only. System tested against IEC 601-1, IEC 601-1 Amendment 1, IEC 601-2-18, UL544, AAMI TIR 12, EMC Directive 89/336/EEC, CAN/CSA-C22.2 standards, and internal functional test requirements.
Technological Characteristics
Robotic arm system; electromechanical actuation. Voice control interface: speaker-dependent speech recognition. Standards: IEC 601-1, IEC 601-1 Amendment 1, IEC 601-2-18, UL544, AAMI TIR 12, EMC Directive 89/336/EEC, CAN/CSA-C22.2. Reusable medical device.
Indications for Use
Indicated for use in all forms of laparoscopic surgery, including cholecystectomy, laparoscopic hernia repair, and laparoscopic appendectomy.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Predicate Devices
- AESOP System (K931783)