Disposable Trocars

K250820 · Sinolinks Medical Innovation, Inc. · GCJ · Jul 11, 2025 · Gastroenterology, Urology

Device Facts

Record IDK250820
Device NameDisposable Trocars
ApplicantSinolinks Medical Innovation, Inc.
Product CodeGCJ · Gastroenterology, Urology
Decision DateJul 11, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Disposable Trocars have applications in minimally invasive surgical procedures to establish a path of entry for endoscopic instruments in abdominal area.

Device Story

Disposable Trocars are manual surgical instruments used to penetrate the abdominal wall during laparoscopic procedures. The device consists of a puncture rod component and a casing component (trocar sleeve). The surgeon manually inserts the device to create a path for endoscopic instruments; once positioned, the puncture rod is withdrawn, leaving the casing to serve as a working channel. A gas injection valve allows connection to a pneumoperitoneum machine, while an integrated choke valve and sealing system maintain pneumoperitoneum by preventing air leakage during instrument insertion or removal. The device is intended for single use in clinical settings by trained surgical staff. It facilitates minimally invasive surgery by providing stable access for endoscopes and staplers, potentially reducing patient trauma compared to open surgery.

Clinical Evidence

No clinical study is included in this submission. Evidence is based on non-clinical bench and ex vivo testing, including biocompatibility (ISO 10993 series), sterility (ISO 11135), shelf-life (ASTM F1980), and simulated transport (ASTM D4169). Ex vivo testing on porcine tissue evaluated penetration force, fixation force, and tip integrity.

Technological Characteristics

Materials: PE, PC, ABS, silica gel. Principle: Manual mechanical puncture and maintenance of pneumoperitoneum via sealing valves. Dimensions: 5, 10, 12, 15 mm diameters; 70, 100 mm lengths. Sterilization: Ethylene Oxide (EO) to SAL 10^-6. Connectivity: None. Software: None.

Indications for Use

Indicated for patients undergoing minimally invasive surgical procedures requiring an entry path for endoscopic instruments in the abdominal area.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Predicate Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION July 11, 2025 Sinolinks Medical Innovation, Inc. Juan Zhao Director of Compliance & Regulatory Affairs Department No.10 Ziwei Road, Zhonglou Zone ChangZhou, Jiangsu CN 213023 RE: K250820 Trade/Device Name: Disposable Trocars Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: Class II Product Code: GCJ Dated: June 11, 2025 Received: June 11, 2025 Dear Juan Zhao: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1} K250820 - Juan Zhao Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K250820 - Juan Zhao Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, James H. Jang -S Digitally signed by James H. Jang -S Date: 2025.07.11 10:38:53 -04'00' James Jang, Ph.D. Acting Assistant Director DHT4A: Division of General Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} FORM FDA 3881 (8/23) Page 1 of 1 PSC Publishing Services (301) 443-6740 EF | DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. | | --- | --- | | 510(k) Number (if known) K250820 | | | Device Name Disposable Trocars | | | Indications for Use (Describe) The Disposable Trocars have applications in minimally invasive surgical procedures to establish a path of entry for endoscopic instruments in abdominal area. | | | Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | | | CONTINUE ON A SEPARATE PAGE IF NEEDED. | | | This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* | | | The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov | | | "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." | | {4} 510(k) Number: K250820 # 510(k) Summary This 510(k) Summary is being submitted in accordance with requirements of Title 21, CFR Section 807.92. The assigned 510(k) Number: K250820. # 1. Submitter: Sinolinks Medical Innovation, Inc. No.10 Ziwei Road, Zhonglou Zone, Changzhou 213023 Jiangsu China. Contact Person: Juan Zhao Contact Title: Director, Regulatory Affairs Phone: +86-51988021670 Email: zhaojuan@sinolinks.com.cn Date Prepared: July 9, 2025 # 2. Proposed Device: Trade Name: Disposable Trocars Common Name: Disposable Trocars Classification Name: Endoscope and accessories Regulation Number: 876.1500 Product Code: GCJ Regulation Class: II # 3. Predicate Device(s): Primary Predicate Device: Trade Name: Disposable Bladeless Trocar, Disposable Optical Trocar and Disposable Bladed Trocar. 510(k) Number: K190029 Regulation Number: 876.1500 Product Code: GCJ Regulation Class: II Manufacturer: Changzhou Xin Neng Yuan Medical Stapler Co., Ltd. # 4. Proposed Device Description Disposable Trocars are medical devices that penetrate the abdominal wall during laparoscopic surgery. They provide a passageway for the surgical device insertion and removal and maintain pneumoperitoneum during surgical procedures. The model numbers of Disposable Trocars include AVTB 5-70, AVTB 5-100, AVTB 10-70, AVTB 10-100, AVTB 12-70, AVTB 12-100, AVTC 5-70, AVTC 5-100, AVTC 10-70, AVTC 10-100, AVTC 12-70, AVTC 12-100, AVTC 15-70, {5} 510(k) Number: K250820 and AVTC 15-100. The AVTB Disposable Trocars comprise an upper sealing component, a casing component, and a puncture rod component. The upper sealing component is composed of a seal lid, an upper retaining ring, a wave seal ring, a conical sealing ring, a lower retaining ring, and a retaining cover for locking. The casing component is composed of choke valve, self-commissioning sealing cap, casing seat, seal ring, trocar sleeve, gas injection valve, and gas injection switch. The puncture rod component is composed of an upper fixing cover, a locking buckle, a puncture rod, and a lower fixing cover. AVTC Disposable Trocars comprise casing component, puncture rod component, upper sealing component, and converter component (only applicable to AVTC 15 specification). The casing component is composed of choke valve, self-commissioning sealing cap, casing seat, sealing ring, trocar sleeve, gas injection valve, and gas injection switch. The puncture rod component is composed of an upper fixing cover and a puncture rod. The upper sealing component (5/10/12 specification) is composed of seal lid, an upper retaining ring, a wave seal ring, a conical sealing ring, a lower retaining ring, and a retaining cover for locking. The upper sealing component (15 specifications) is composed of a seal lid, an elastic seal ring, and a retaining cover for locking. The converter component (15 specifications) is composed of converter, converter cover, sealing cap of upper converter cover, and upper converter cover. Disposable Trocars are divided into B and C according to different shapes. According to the inner diameter of the trocar, it is divided into four sizes: 5, 10, 12, and 15. According to the length of the trocar, it is divided into two sizes: 70 and 100. ## 5. Indications for use The Disposable Trocars have applications in minimally invasive surgical procedures to establish a path of entry for endoscopic instruments in abdominal area. ## 6. Technological Characteristics: The materials of Disposable Trocars are PE, PC, ABS, and silica gel. The assembled Disposable Trocars puncture the hole (use a blade to cut a pre-puncture hole) of the abdomen, reach the predetermined position through the {6} 510(k) Number: K250820 abdominal wall, and then withdraw the puncture rod component, leaving the casing component as the working channel of endoscopic stapler and endoscope. The gas injection valve is connected to the pneumoperitoneum machine. The choke valve and casing component form a closed space with the human body to maintain the pneumoperitoneum. When the stapler or endoscope is inserted, due to the existence of choke valve, there is basically no air leakage. A little air leakage can be supplemented by pneumoperitoneum machine. ## 7. Summary of non-clinical testing: The following non-clinical tests, including both bench and ex vivo, were conducted to demonstrate that the performance of the proposed device is substantially equivalent to that of the predicate device and to verify that the proposed device met all design specifications. Results of biocompatibility, sterility, and packaging tests demonstrated that the proposed device met its specifications and requirements. Dimension verification and bench performance test were conducted to demonstrate the essential performance of the proposed device. The results of the tests listed below showed that the subject device is substantially equivalent to the predicate device. 1. Compatible with endoscope and endoscopic stapler 2. Flexibility 3. Parts compatible with each other 4. Airtightness and air resistance 5. Connection strength 6. Luer connector 7. Insertion and pull-out performance of puncture rod 8. Gas leak rate 9. Endotoxin limit test An ex vivo study was conducted on porcine tissue to evaluate the penetration force and fixation force. In addition, tip integrity was evaluated after each insertion. Shelf-life testing was conducted based on an accelerated aging test in accordance with ASTM F1980-21 Standard Guide for Accelerated Aging of Sterile Barrier Systems and Medical Devices. The real-time aging study is ongoing to evaluate longer stability and will support the results of the accelerated aging test. Simulated transport testing was conducted based on ASTM D4169:2022 Standard Practice for Performance Testing of Shipping Containers and Systems and support product and packaging performance {7} 510(k) Number: K250820 Sterilization validation was conducted in accordance with ISO 11135:2014 using the overkill validation methods to demonstrate the ability to achieve a sterility assurance level of $10^{-6}$. Biocompatibility testing was performed in accordance with: - FDA Guidance, Use of International Standard ISO-10993, “Biological Evaluation of Medical Devices Part 1: Evaluation and Testing within a risk management process” - ISO 10993-1:2018 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process - ISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity - ISO 10993-10:2021 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization - ISO 10993-12:2021 Biological evaluation of medical devices - Part 12: Sample preparation and reference materials - ISO 10993-11:2017 Biological evaluation of medical devices - Part 8 Tests for systemic toxicity - ISO 10993-23:2021 Biological evaluation of medical devices - PART 23: Tests for irritation - ISO 10993-18:2020 Biological evaluation of medical devices Chemical characterization of medical device materials within a risk management process Sterility and packaging: Accelerated aging, simulated transport, product sterility performance, and packaging performance tests were tested according to: - ISO 10993-7:2008 Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals - ASTM F88/F88M-23 Standard Test Method for Seal Strength of Flexible Barrier Materials - ASTM F1929-23 Standard Test Method for Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration - USP <85> Bacterial Endotoxins Test {8} 510(k) Number: K250820 ## 8. Clinical Test Conclusion No clinical study is included in this submission. ## 9. Substantially Equivalent (SE) Comparison Table 1 Comparison of Technology Characteristics | Item | Proposed Device Disposable Trocars | Predicate Device Disposable Bladeless Trocar, Disposable Optical Trocar and Disposable Bladed Trocar (K190029) | | --- | --- | --- | | Classification | II | II | | Regulation Number | 876.1500 | 876.1500 | | Product Code | GCJ | GCJ | | Intended Use | The Disposable Trocars have applications in minimally invasive surgical procedures to establish a path of entry for endoscopic instruments in abdominal area. | The devices, Disposable Bladeless Trocar, Disposable Optical Trocar and Disposable Bladed Trocar, have applications in abdominal, thoracic, and gynecologic minimally invasive surgical procedures to establish a path of entry for endoscopic instruments. | | Configuration | Puncture rod | Puncture needle | {9} 510(k) Number: K250820 | | Trocar sleeve Converter | Puncture sleeve Reducer cap | | --- | --- | --- | | Single Use | Single Use | Single Use | | Operation Mode | Manually | Manually | | Accessory | No accessory | Puncture sleeve, reducer cap | | Safety features | No safety feature | No safety feature | | Labeling | Comply with 21 CFR section 801 | Comply with 21 CFR section 801 | | Shaft Diameter | Available in 5 mm, 10 mm, 12 mm, and 15 mm | Available in 3 mm, 5 mm, 8 mm, 10 mm, 12 mm, and 15 mm | | Shaft Length | Available in 70 mm and 100 mm | Available in 75 mm and 100 mm | | Material | ABS, PC, PE, colorant, silica gel | ABS, PC, PE, colorant, rubber | | Trocar Width | 61 mm, 65 mm | 52.4 mm, 61.4 mm | | Total Length | 151 mm, 194 mm, 204 mm | 158 mm, 184 mm, 172 mm, 197 mm | | Needle Tip Shape | Fin | Fin | | Sterilization | EO sterilized | EO sterilized | | SAL | 10^{-6} | 10^{-6} | 6 {10} 510(k) Number: K250820 | Endotoxin Limit | 20 EU per device | 20 EU per device | | --- | --- | --- | | Shelf life | 3 years | 2 years | | Packaging method | Sealing method | Sealing method | | Cytotoxicity | No cytotoxicity | No cytotoxicity | | Sensitization | No sensitization | No sensitization | | Skin Irritation | No irritation | No irritation | | Pyrogen | No pyrogen | No pyrogen | 10. Conclusion: The proposed Disposable Trocars are found substantially equivalent to the predicate device. The differences between the proposed and predicate devices do not raise new or different questions of safety and/or effectiveness. The non-clinical performance testing demonstrates that the device is as safe and effective as the legally marketed device.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...