EG-2940, VIDEO GASTROSCOPE
Device Facts
| Record ID | K961564 |
|---|---|
| Device Name | EG-2940, VIDEO GASTROSCOPE |
| Applicant | Pentax Precision Instrument Corp. |
| Product Code | FDS · Gastroenterology, Urology |
| Decision Date | Jul 9, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
| Attributes | Therapeutic, Pediatric |
Indications for Use
The EG-2940, Video Gastroscope, is intended to provide visualization (via a video monitor) of, and therapeutic access to, the Upper Gastrointestinal Tract. The Upper Gastrointestinal Tract includes, but is not restricted to, the organs; tissues; and subsystems: Esophagus, Stomach, Duodenum, and Small Bowel. The instrument is introduced per orally when indications consistent with the requirement for the procedure are observed in Adult and Pediatric patient populations.
Device Story
Flexible video gastroscope; used for visualization and therapeutic access to upper GI tract. Input: light from 300W xenon lamp (via video processor) illuminates body cavity; CCD collects image data. Operation: light filtered via RGB color wheel; CCD captures data per color strobe; video processor compiles full color frame. Output: video signal to monitor. Used in clinical settings by physicians. Features: flexible insertion tube, control body for angulation, air/water delivery, suction, accessory channel for biopsy forceps. Benefits: enables diagnostic visualization and therapeutic intervention in esophagus, stomach, duodenum, and small bowel.
Clinical Evidence
No clinical data.
Technological Characteristics
Flexible endoscope with CCD imaging sensor and light-carrying bundles. Requires external video processor with 300W xenon lamp and RGB color wheel filtering. Includes working channel for accessories. Connectivity: proprietary connection to video processor. Sterilization: not specified.
Indications for Use
Indicated for visualization and therapeutic access to the upper gastrointestinal tract (esophagus, stomach, duodenum, small bowel) in adult and pediatric patients requiring endoscopic procedures.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Predicate Devices
- EC-3800L, Video Colonoscope Pentax (K951574)
- FG-23H, Fiber Gastroscope Pentax (K850020)
- EPM-330, Video Processor Pentax (K934918)