Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart B — Diagnostic Devices](/submissions/GU/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500) → ODE — Endoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd)

# ODE · Endoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd)

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE

## Overview

- **Product Code:** ODE
- **Device Name:** Endoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd)
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **Implant:** yes

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (20 of 20)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K233240](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K233240.md) | GERDX-System | G-Surg GmbH | Jun 21, 2024 | SESE |
| [K240879](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K240879.md) | EsophyX Z+ Device with SerosaFuse Fasteners and Accessories | Endogastric Solutions, Inc. | Apr 26, 2024 | SESE |
| [K172811](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K172811.md) | EsophyX Z, EsophyX2 HD | Endogastric Solutions, Inc. | Oct 19, 2017 | SESE |
| [K171307](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K171307.md) | EsophyX2 HD Device with SerosaFuse Fasteners and Accessories, EsophyX Z Device with SerosaFuse Fasteners and Accessories | Endogastric Solutions, Inc. | Jun 22, 2017 | SESE |
| [K160960](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K160960.md) | EsophyX® Z Device with SerosaFuse Fasteners and Accessories | Endogastric Solutions, Inc. | May 1, 2016 | SESE |
| [K151001](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K151001.md) | MUSE System | Medigus , Ltd. | Jun 5, 2015 | SESE |
| [K143645](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K143645.md) | EsophyX® Z Fastener Delivery Device | Endogastric Solutions, Inc. | Mar 4, 2015 | SESE |
| [K143634](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K143634.md) | MUSE System | Medigus , Ltd. | Jan 20, 2015 | SESE |
| [K142113](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K142113.md) | ESOPHYX2 HD | Endogastric Solutions, Inc. | Sep 30, 2014 | SESE |
| [K132151](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K132151.md) | SRS ENDOSCOPIC STAPLING SYSTEM | Medigus , Ltd. | Mar 19, 2014 | SESE |
| [K120299](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K120299.md) | SRS ENDOSCOPIC STAPLING SYSTEM | Medigus , Ltd. | May 18, 2012 | SESE |
| [K092400](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K092400.md) | ENDOGASTRIC SOLUTIONS ESOPHYX2 SYSTEM WITH SEROSAFUSE FASTENER AND ACCESSORIES, MODEL 2.7.5 | Endogastric Solutions, Inc. | Nov 6, 2009 | SESE |
| [K072125](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K072125.md) | ENDOSCOPIC PLICATION SYSTEM, EPS, EPLICATOR, PLICATOR INSTRUMENT | Ndo Surgical, Inc. | Oct 18, 2007 | SESE |
| [K071553](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K071553.md) | ENDOSCOPIC PLICATION SYSTEM; EPS; PLICATOR | Ndo Surgical, Inc. | Sep 18, 2007 | SESE |
| [K071651](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K071651.md) | EGS SEROSAFUSE IMPLANTABLE FASTENERS, ASSOCIATED DELIVERY DEVICES AND ACCESSORIES | Endogastric Solutions, Inc. | Sep 14, 2007 | SESE |
| [K032820](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K032820.md) | MODIFICATION TO ENDOSCOPIC PLICATION SYSTEM | Ndo Surgical, Inc. | Oct 23, 2003 | SESE |
| [K031262](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K031262.md) | ENDOSCOPIC PLICATION SYSTEM, MODEL 160-00760 | Ndo Surgical, Inc. | May 23, 2003 | SESE |
| [K023234](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K023234.md) | ENDOSCOPIC PLICATION SYSTEM | Ndo Surgical, Inc. | Apr 17, 2003 | SESE |
| [K003956](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K003956.md) | BARD ENDOCINCH SUTURING SYSTEM # 000452; 000454; 000595 | C.R. Bard, Inc. | Jan 5, 2001 | SESE |
| [K994290](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE/K994290.md) | BARD ENDOSCOPIC SUTURING SYSTEM | C.R. Bard, Inc. | Mar 20, 2000 | SESE |

## Top Applicants

- Endogastric Solutions, Inc. — 8 clearances
- Ndo Surgical, Inc. — 5 clearances
- Medigus , Ltd. — 4 clearances
- C.R. Bard, Inc. — 2 clearances
- G-Surg GmbH — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/ODE)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
