OCY · Endoscopic Guidewire, Gastroenterology-Urology

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeOCY
Device NameEndoscopic Guidewire, Gastroenterology-Urology
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 43)

Showing 20 most recent of 43 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K153264EasyPass GuidewireMedi-Globe CorporationMay 19, 2016SESE
K151471Radifocus Glidewire Endoscopic WireTerumo Medical CorporationSep 17, 2015SESE
K150927Orchestra Hydrophilic Guidewire standard angled, Orchestra Hydrophilic Guidewire straight stiff, Orchestra Hydrophilic Guidewire angled stiff,Orchestra Hydrophilic Guidewire standard straight, Orchestra Hydrophilic Guidewire straight stiffColoplast A/SMay 27, 2015SESE
K150225NovaGold High Performance GuidewireNeometrics, Inc.Mar 16, 2015SESE
K142950Acrobat Calibrated Tip Wire GuideWilson-Cook Medical, Inc.Nov 5, 2014SESE
K141820JAGWIRE HIGH PERFORMANCE GUIDWIREBoston Scientific CorpOct 21, 2014SESE
K142397Predicate III GuidewireLake Region MedicalSep 19, 2014SESE
K140482MANDREL GUIDEWIRELake Region MedicalApr 8, 2014SESE
K133076NOVAGOLD HIGH PERFORMANCE GUIDEWIRENeometrics, Inc.Feb 20, 2014SESE
K131072ORCHESTRA HYDROPHILIC GUIDEWIRE STANDARD ANGLED, ORCHESTRA HYDROPHILIC GUIDEWIRE STRAIGHT STIFF, ORCHESTRA HYDROPHILICColoplast A/SJul 9, 2013SESE
K124052OSTAVI HYDROPHILIC GUIDEWIRELake Region MedicalFeb 26, 2013SESE
K123438XENX STONE MANAGEMENT DEVICEXenolith MedicalJan 10, 2013SESE
K123439NEO ERCP GUIDEWIRENeometrics, Inc.Jan 3, 2013SESE
K122816AXCESS SOFT TIP WIRE GUIDEWilson-Cook Medical, Inc.Oct 9, 2012SESE
K113692XENXXenolith MedicalAug 9, 2012SESE
K091417SINGLE USE GUIDEWIRE, MODELS G-240-2527S, G-240-2545S, G-240-2527A, G-240-2545A, G-240-3527S, G-240-3545S & G-240-3527ATerumo Corp.May 22, 2009SESE
K082536COOK WIRE GUIDESCook Urological, Inc.Oct 27, 2008SESE
K081708TAXI ENDOSCOPIC GUIDEWIRELake Region Mfg., Inc.Aug 26, 2008SESE
K080508MANDREL GUIDEWIRES OR M-WIRELake Region MedicalMar 21, 2008SESE
K072354GUIDEWIRE, MODEL G-V220-3527S AND OTHERSAccellent, Inc.Dec 7, 2007SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...