OCT · Anti Fog Solution And Accessories, Endoscopy

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeOCT
Device NameAnti Fog Solution And Accessories, Endoscopy
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology
3rd-Party ReviewableYes

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 27)

Showing 20 most recent of 27 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K251068KnoxFog Anti-fogging DeviceUv One Hygienics, Inc.Aug 27, 2025SESE
K231822GOLFF Sterile Anti-Fog SolutionBatrik Medical Manufacturing, Inc.Feb 26, 2024SESE
K221293E-Brik Visualization AssistantJdi Surgical, Inc.Jul 7, 2022SESE
K190864Konix Anti-Fog SolutionTurkuaz Saglik Hizmetleri Medikal Temizlik Kimyasal UrunlerAug 27, 2020SESE
K181887AMD Anti-Fog SolutionAdvanced Medical Design Co., Ltd.Jan 22, 2019SESE
K163257VitreOx Anti-fog SolutionSio2 Nanotech, LLCMay 24, 2017SESE
K152948Medline Anti-Fog SolutionMedline Industries, Inc.Feb 4, 2016SESE
K120821LLICS(TM) LAPARASCOPIC LENS INTERNAL CLEANING SYSTEMMisder, LLCMay 11, 2012SESE
K111622UNIMAX ANTI-FOG SOLUTIONUnimax Medical Systems, Inc.Sep 9, 2011SESE
K102452DEFOGGING AND CLEANING SOLUTION- FLO-XMinimally Invasive Devices, LLCDec 23, 2010SESE
K080613CLEAR-VU SYSTEM, MODELS: CVL-01-1000, CVL-01-1030, CVL-01-1045Minimally Invasive Devices, LLCNov 6, 2008SESE
K063587XODUS MEDICAL ANTI-FOG SOLUTIONXodus Medical, Inc.Jan 9, 2007SESE
K051979ORS MODEL 6000 ENDOSCOPE HOLDERO.R. Solutions, Inc.Aug 30, 2005SESE
K022826CLEAR-IT ANTI-FOG, MODEL PS003Preservation Solutions, Inc.Oct 9, 2002SESE
K993604ENDOSCOPIC ANTI FOG DEVICEMectra Labs, Inc.Mar 3, 2000SESE
K982465DEROYAL INDUSTRIES, INC. DEFOGGERDeroyal Industries, Inc.Aug 11, 1998SESE
K974454CLEARFIELD ANTI-FOG STERILE WIPE, PRODUCT NUMBER 300-004Tucson Medical Corp.Dec 18, 1997SESE
K945732FOG FREETonn Chemical Co., Inc.Jan 4, 1995SESE
K942576CLEAR LENS ENDOSCOPIC FOG REDUCTION DEVICEWhite Knight HealthcareJul 5, 1994SESE
K923843FOGLESSSorex MedicalMar 25, 1994SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...