Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart B — Diagnostic Devices](/submissions/GU/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500) → NLM — Laparoscope, General & Plastic Surgery, Reprocessed

# NLM · Laparoscope, General & Plastic Surgery, Reprocessed

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM

## Overview

- **Product Code:** NLM
- **Device Name:** Laparoscope, General & Plastic Surgery, Reprocessed
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (20 of 23)

Showing 20 most recent of 23 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K201511](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K201511.md) | Reprocessed Endoscopic Trocars and Sleeves | Stryker Sustainability Solutions | Jul 31, 2020 | SESE |
| [K182828](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K182828.md) | Medline ReNewal Reprocessed Carter-Thomason Needle Point Suture Passer | Surgical Instrument Service and Savings, Inc. | Apr 15, 2019 | SESE |
| [K172097](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K172097.md) | Reprocessed Ethicon Bladeless Trocars; Reprocessed Ethicon Universal Trocar Sleeves | Renovo, Inc. | Oct 6, 2017 | SESE |
| [K172093](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K172093.md) | Reprocessed Covidien Trocar | Renovo, Inc. | Oct 5, 2017 | SESE |
| [K160740](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K160740.md) | Medline ReNewal Reprocessed ENDOPATH XCEL Trocar with OPTIVIEW Technology | Surgical Instrument Service and Savings, Inc. | May 6, 2016 | SESE |
| [K153258](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K153258.md) | Medline ReNewal Reprocessed Versaport V2 Bladeless Optical Trocars | Surgical Instrument Service and Savings (Dba Medline Renewal | Apr 5, 2016 | SESE |
| [K133414](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K133414.md) | REPROCESSED CLOSURE SYSTEM | Sterilmed, Inc. | Jan 22, 2014 | SESE |
| [K132629](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K132629.md) | REPROCESSED DILATING TIP TROCARS | Stryker Sustainability Solutions | Dec 31, 2013 | SESE |
| [K121240](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K121240.md) | REPROCESSED ENDOSCOPIC TROCARS | Sterilmed, Inc. | Jun 11, 2012 | SESE |
| [K111002](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K111002.md) | REPROCESSED ENDOSCOPIC TROCARS | Sterilmed, Inc. | Jul 18, 2011 | SESE |
| [K100080](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K100080.md) | REPROCESSED TROCARS, MODEL B5LT AND CB5LT | Ascent Healthcare Solutions | Mar 19, 2010 | SESE |
| [K063788](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K063788.md) | REPROCESSED ENDOSCOPIC TROCARS AND CANNULAS | Ascent Healthcare Solutions | Oct 15, 2007 | SESE |
| [K070059](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K070059.md) | REPROCESSED TROCARS | Ascent Healthcare Solutions | Oct 2, 2007 | SESE |
| [K060676](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K060676.md) | NES REPROCESSED ENDOSCOPIC TROCAR | Northeast Scientific, Inc. | Sep 7, 2007 | SESE |
| [K062497](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K062497.md) | REPROCESSED TROCARS | Ascent Healthcare Solutions | Jan 31, 2007 | SESE |
| [K053585](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K053585.md) | VANGUARD REPROCESSED SUTURE PASSER | Ascent Healthcare Solutions | Oct 11, 2006 | SESE |
| [K052299](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K052299.md) | REPROCESSED ENDOSCOPIC TROCAR | Sterilmed, Inc. | May 23, 2006 | SESE |
| [K043592](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K043592.md) | REPROCESSED ENDOSCOPIC TROCAR | Sterilmed, Inc. | May 23, 2005 | SESE |
| [K043253](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K043253.md) | VANGUARD REPROCESSED DILATING TIP AND BLUNT TROCARS | Vanguard Medical Concepts, Inc. | Apr 8, 2005 | SESE |
| [K043594](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM/K043594.md) | VANGUARD REPROCESSED BLADED TROCAR, NON-BLADED TROCAR, TROCAR ACCESSORIES | Vanguard Medical Concepts, Inc. | Mar 31, 2005 | SESE |

## Top Applicants

- Sterilmed, Inc. — 6 clearances
- Ascent Healthcare Solutions — 5 clearances
- Renovo, Inc. — 2 clearances
- Stryker Sustainability Solutions — 2 clearances
- Surgical Instrument Service and Savings, Inc. — 2 clearances

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/NLM)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
