Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart B — Diagnostic Devices](/submissions/GU/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500) → FFS — Image, Illumination, Fiberoptic, For Endoscope

# FFS · Image, Illumination, Fiberoptic, For Endoscope 

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS

## Overview

- **Product Code:** FFS
- **Device Name:** Image, Illumination, Fiberoptic, For Endoscope 
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (20 of 26)

Showing 20 most recent of 26 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K072521](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K072521.md) | COOK FIBER OPTIC BUNDLE AND FLEXOR DEFLECTING ACCESS SHEATH | Cook Urological, Inc. | Nov 20, 2007 | SESE |
| [K061622](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K061622.md) | PS SERIES | Photonic Optische Gerate Gesmbh & Cokg | Mar 5, 2007 | SESE |
| [K063309](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K063309.md) | TRU-CABLE | Truphatek International, Ltd. | Jan 12, 2007 | SESE |
| [K061025](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K061025.md) | ACCUTECH ENDOLITE PROBE | Accutech Medical Technologies, Inc. | May 31, 2006 | SESE |
| [K023633](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K023633.md) | SOVIS OPTIQUE'S ENDOSCOPIC CABLE | Sovis Optique | Dec 31, 2002 | SESE |
| [K001698](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K001698.md) | MICRO LINK ENDOSCOPIC FIBER CABLE, MODEL B1-90159 | Cogent Light Technologies, Inc. | Jul 17, 2000 | SESE |
| [K994084](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K994084.md) | SMITH & NEPHEW XENON LIGHT SOURCES AND ACCESSORIES | Smith & Nephew, Inc. | Jan 20, 2000 | SESE |
| [K991323](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K991323.md) | SMITH & NEPHEW SUBCUTANEOUS ILLUMINATOR | Smith & Nephew, Inc. | Jul 6, 1999 | SESE |
| [K983714](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K983714.md) | SOLARTEC SOURCE 270, MODEL # 90123 | Cogent Light Technologies, Inc. | Dec 23, 1998 | SESE |
| [K982462](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K982462.md) | FIBER OPTIC ENDOILLUMINATION PROBE | Microvision, Inc. | Sep 14, 1998 | SESE |
| [K980636](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K980636.md) | FIBER OPTIC ENDOILLUMINATION PROBE | Dutch Ophthalmic USA, Inc. | May 20, 1998 | SESE |
| [K970217](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K970217.md) | VISTA ILLUMINATION SYSTEM | Vista Medical Technologies, Inc. | Apr 2, 1997 | SESE |
| [K962595](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K962595.md) | KARL STORZ XENON 300 LIGHT SOURCE FOR NON-FLASH APPLICATIONS | KARL STORZ Endoscopy-America, Inc. | Sep 4, 1996 | SESE |
| [K950960](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K950960.md) | REDDY ILLUMINATOR | Luxtec Corp. | Sep 8, 1995 | SESE |
| [K945102](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K945102.md) | MTA:ANGENIEUX STARPOINT XE XENON LIGHT SOURCE | Alm Surgical Equipment, Inc. | Nov 4, 1994 | SESE |
| [K944688](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K944688.md) | LUMINOUS 150 DUAL  LAMPFIBEROPTIC ILLUMINATOR | Progressive Dynamics, Inc. | Nov 1, 1994 | SESE |
| [K940963](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K940963.md) | XENON LIGHT SOURCE | Incredivision, Inc. | Apr 8, 1994 | SESE |
| [K940962](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K940962.md) | LIQUID LIGHT 500 | Incredivision, Inc. | Apr 8, 1994 | SESE |
| [K933216](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K933216.md) | KARL STORZ ENDOSCOPY-AMERICA, INC. | KARL STORZ Endoscopy-America, Inc. | Sep 9, 1993 | SESE |
| [K892145](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS/K892145.md) | FIBER OPTIC LIGHT TRANSMISSION CABLE | Opto Vision, Inc. | Sep 29, 1989 | SESE |

## Top Applicants

- Cogent Light Technologies, Inc. — 2 clearances
- Incredivision, Inc. — 2 clearances
- KARL STORZ Endoscopy-America, Inc. — 2 clearances
- Smith & Nephew, Inc. — 2 clearances
- Accutech Medical Technologies, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FFS)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
