Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart B — Diagnostic Devices](/submissions/GU/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500) → FER — Anoscope And Accessories

# FER · Anoscope And Accessories

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER

## Overview

- **Product Code:** FER
- **Device Name:** Anoscope And Accessories
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (20 of 27)

Showing 20 most recent of 27 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K250645](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K250645.md) | SleeveLUX 24 Anoscope/Proctoscope (P2001); SleeveLUX 16 Anoscope/Proctoscope (P2002) | Haemoband Surgical, Ltd. | Oct 9, 2025 | SESE |
| [K242668](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K242668.md) | Gastro Concepts Air Assist | Gastro Concepts, LLC | Dec 13, 2024 | SESE |
| [K230439](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K230439.md) | WellCare Anoscope | Well Care (Wuhan) Medical Technology Co., Ltd. | Dec 22, 2023 | SESE |
| [K200021](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K200021.md) | Applied Medical Anoscope | Applied Medical Resources | Jan 6, 2021 | SESE |
| [K171701](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K171701.md) | GelPOINT Path Transanal Access Platform | Applied Medical Resources Corp. | Jul 20, 2017 | SESE |
| [K133393](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K133393.md) | GELPOINT PATH TRANSANAL ACCESS PLATFORM | Applied Medical Resources Corp. | Jan 2, 2014 | SESE |
| [K133687](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K133687.md) | THD N-ANO ANOSCOPE | Thd Spa | Dec 11, 2013 | SESE |
| [K121604](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K121604.md) | ANOSPEC DISPOSABLE ANSOSCOPE WITH LIGHT | Obp Corporation | Jul 27, 2012 | SESE |
| [K121135](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K121135.md) | THD ANOSCOPE, PROCTOSCOPE, RECTOSCOPE, RECTOSCOPE AND LIGHT-SCOPE | Thd Spa | Jun 1, 2012 | SESE |
| [K110792](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K110792.md) | GELPOINT PATH | Applied Medical Resources Corp. | May 23, 2011 | SESE |
| [K103647](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K103647.md) | THD DISPOSABLE ANOSCOPES, PROCTOSCOPES AND RECTOSCOPES | Thd Spa | Mar 1, 2011 | SESE |
| [K093896](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K093896.md) | ETHICON ENDO SURGERY SLOTTED ANOSCOPE | Ethicon Endo-Surgery, Inc. | Mar 25, 2010 | SESE |
| [K091490](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K091490.md) | FAMILY OF THD DISPOSABLE ANOSCOPES/PROCTOSCOPES/RECTOSCOPES | Thd Spa | Jun 11, 2009 | SESE |
| [K090432](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K090432.md) | HEMORPEX SYSTEM | Angiologica B. M. Srl | May 29, 2009 | SESE |
| [K080132](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K080132.md) | THD DISPOSABLE ANOSCOPE/PROCTOSCOPE | Thd Spa | Apr 9, 2008 | SESE |
| [K070913](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K070913.md) | SELF-LIGHT DISPOSABLE ANOSCOPE | Sapimed S.P.A. | Aug 10, 2007 | SESE |
| [K060623](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K060623.md) | SHORTSHOT SAEED HEMORRHOIDAL MULTI-BAND LIGATOR WITH TRIVIEW ANOSCOPE | Cook Ireland, Ltd. | Sep 6, 2006 | SESE |
| [K020702](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K020702.md) | O'REGAN DISPOSABLE ANOSCOPE | Canadian Theatre Products , Ltd. | Mar 29, 2002 | SESE |
| [K011825](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K011825.md) | RECTOSIGHT RS300-04;AND PROTOSIGHT PS300-04 DEVICE | Sightline Technologies , Ltd. | Jul 11, 2001 | SESE |
| [K994130](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER/K994130.md) | RECTOSIGHT RS 300-04 | Sightline Technologies , Ltd. | Jun 30, 2000 | SESE |

## Top Applicants

- Thd Spa — 5 clearances
- Applied Medical Resources Corp. — 3 clearances
- Sightline Technologies , Ltd. — 2 clearances
- Welch Allyn, Inc. — 2 clearances
- Angiologica B. M. Srl — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FER)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com