# FDA · Enteroscope And Accessories

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA

## Overview

- **Product Code:** FDA
- **Device Name:** Enteroscope And Accessories
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (19 of 19)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K251204](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K251204.md) | FUJIFILM Stiffening Wire Device (SW-2000) | FUJIFILM Healthcare Americas Corporation | Sep 26, 2025 | SESE |
| [K233321](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K233321.md) | Double Balloon Endoscope  EN-840T, Over-tube TS-1214C | FUJIFILM Healthcare Americas Corporation | Jun 13, 2024 | SESE |
| [K231323](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K231323.md) | Ancora-SB | Aspero Medical, Inc. | Aug 31, 2023 | SESE |
| [K223295](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K223295.md) | Endoscope Model EN-580T, Over-tube TS-1314B, Balloon BS-4, Tube Kit TY-500D | Fujifilm Corporaton | Jan 11, 2023 | SESE |
| [K213195](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K213195.md) | Balloon BS-3 | Fujifilm Corporation | Oct 29, 2021 | SESE |
| [K191330](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K191330.md) | Arc Enterocuff | Boddingtons Plastics, Ltd. | Jan 31, 2020 | SESE |
| [K183032](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K183032.md) | FUJIFILM Double Balloon Endoscope EI580BT | Fujifilm Corporation | Jun 24, 2019 | SESE |
| [K183683](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K183683.md) | FUJIFILM Double Balloon Endoscopes EN-580T, EC-450BI5, EN-450P5/20, and EN-450T5 | Fujifilm Corporation | Feb 27, 2019 | SESE |
| [K143556](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K143556.md) | Fujifilm Double Balloon Endoscopes Models EN-530T and EN-580T | Fujifilm Medical Systems U.S.A, Inc. | Aug 20, 2015 | SESE |
| [K071254](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K071254.md) | SMALL INTESTINAL VIDEOSCOPE SYSTEM | Olympus Medical Systems Corporation | Mar 25, 2008 | SESE |
| [K060923](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K060923.md) | NAVIAID BGE DEVICE, MODEL 21-001 | Smart Medical Systems , Ltd. | Aug 15, 2006 | SESE |
| [K060235](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K060235.md) | ENDO-EASE ENDOSCOPIC OVERTUBE | Spirus Medical, Inc. | Aug 4, 2006 | SESE |
| [K040048](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K040048.md) | FUJINON DOUBLE BALLOON ENTEROSCOPY SYSTEM | Fujinon, Inc. | Jun 7, 2004 | SESE |
| [K031256](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K031256.md) | XSIF-1TQ140A SMALL INTESTINAL VIDEOSCOPE | Olympus Opto-Electronics Co., Ltd. | Jul 23, 2003 | SESE |
| [K993704](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K993704.md) | GASTRO-INTESTINAL SYSTEM EN-410WM | Fujinon, Inc. | Feb 11, 2000 | SESE |
| [K904800](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K904800.md) | SIF-SW | Olympus Corp. | Mar 27, 1991 | SESE |
| [K840722](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K840722.md) | ENTEROSCOPE | Trimedyne, Inc. | Jun 7, 1984 | SESE |
| [K841396](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K841396.md) | TRANSFER TROLLEY | Setma, Inc. | May 7, 1984 | SESE |
| [K810757](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA/K810757.md) | I.V. ADMINISTRATION SET | American Mcgaw | Apr 8, 1981 | SESE |

## Top Applicants

- Fujifilm Corporation — 3 clearances
- Fujinon, Inc. — 2 clearances
- FUJIFILM Healthcare Americas Corporation — 2 clearances
- Trimedyne, Inc. — 1 clearance
- Spirus Medical, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA](https://fda.innolitics.com/submissions/GU/subpart-b%E2%80%94diagnostic-devices/FDA)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).