MAXIFLEX - SEMI FLEX SCOPE, 25 TO 65 CM

K111480 · Technology Delivery Systems, Inc. · FGB · Apr 4, 2012 · Gastroenterology, Urology

Device Facts

Record IDK111480
Device NameMAXIFLEX - SEMI FLEX SCOPE, 25 TO 65 CM
ApplicantTechnology Delivery Systems, Inc.
Product CodeFGB · Gastroenterology, Urology
Decision DateApr 4, 2012
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The MaxiFlex Semi Flex Scopes are intended to be used by trained medical professionals to examine the urinary tract, and using additional accessories, to perform various diagnostic and therapeutic procedures. Device may be re-used and re-sterilized by the EtO sterilization process up to 3 times

Device Story

Flexible endoscope for urological examination; features operator-controlled distal tip deflection. Available in 25 cm and 65 cm lengths; includes working channel for instrumentation or irrigation (via 'Y Port' accessory). Used by trained medical professionals in clinical settings for urinary tract visualization and procedures. Device is reusable; validated for up to 3 EtO sterilization cycles. Output is direct visualization of urinary tract anatomy for clinical decision-making.

Clinical Evidence

Bench testing only. Device tested for four (4) EtO sterilization cycles to validate re-use capability; no degradation from original design specifications observed.

Technological Characteristics

Flexible endoscope; operator-controlled distal tip deflection. Lengths: 25 cm and 65 cm. Includes working channel; compatible with 'Y Port' accessory for irrigation. Sterilization: EtO.

Indications for Use

Indicated for trained medical professionals to examine the urinary tract and perform diagnostic and therapeutic procedures in clinical settings.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls: 1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following: 1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures. 2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use. 3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use. 2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes. 3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches 4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error. 5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program. (6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms. (7) Labeling must include: (i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified; (ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA; (iii) Identification of compatible devices; (iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification; (v) Reprocessing instructions for reusable components; (vi) A shelf life for any sterile components; (vii) A description of the device-specific use training program; (viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and (ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance. (8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include: (i) Device motion accuracy and repeatability; (ii) System testing; (iii) Instrument reliability; (iv) Crosstalk; (v) Table motion control; (vi) Thermal effects on tissue; (vii) User-device interface performance; (viii) Workspace access testing; and (ix) Performance testing with compatible devices. (9) Software verification, validation, and hazard analysis must be performed. (10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed. (11) Performance data must demonstrate the sterility of all patient-contacting device components. (12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life. (13) Performance data must validate the reprocessing instructions for the reusable components of the device. (14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible. (15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic. (16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information: (i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and (ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ MaxiFlex Advanced Surgical Devices for Urology K111480 APR - 4 2012 ## Summary This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR Part 807.92 for the Maxi-Flex Semi-Flex Scopes™ #### 1. Company making the submission: | Owner Name: | MaxiFlex, LLC | |--------------------------|-------------------------| | Address: | 1516 Thalia Street | | | New Orleans, LA 70130 | | Telephone: | 225-978-9237 | | Fax: | 504-265-8977 | | Contact: | Gary Ventrella | | E-mail: | garyventrella@me.com | | Correspondent/consultant | Harvey Knauss | | Address: | 1516 Thalia Street | | | New Orleans, LA 70130 | | Telephone: | 832-675-9281 | | Fax: | 713-723-0786 | | E-mail: | Harvey.knauss@gmail.com | ## 2. Device Name: | Trade/Proprietary Name: | Maxi-Flex Semi-Flex Scopes™ | |-------------------------|-----------------------------| | Common Name: | Endoscopes and Accessories | | Regulation Number: | 21 CFR 876.1500 | | Product Code: | FGB | | Device Class: | Class II | #### 3. Predicate Devices: The Maxi-Flex Semi-Flex Scopes™ is substantially equivalent to the Maxi-Flex Semi-Flex Scopes [K062725] and ACMI DUR-8 [K023358]. ## 4. Indications for Use Statement: The MaxiFlex Semi Flex Scopes are intended to be used by trained medical professionals to examine the urinary tract, and using additional accessories, to perform various diagnostic and therapeutic procedures. Device may be re-used and re-sterilized by the EtO sterilization process up to 3 times > 1516 Thalia Street New Orleans, LA 70130 Phone: (504) 265-8972 Fax: (504) 265-8977 www.MaxiFlexLLC.com {1}------------------------------------------------ Image /page/1/Picture/0 description: The image shows the logo for "MaxiFlex Advanced Surgical Devices for Urology". The logo has a series of black dots in an arc above the word "MaxiFlex". Below the word "MaxiFlex" is the phrase "Advanced Surgical Devices for Urology". To the right of the phrase is a starburst design. - 5. Description of Device: The Maxi-Flex Semi Flex Scopes™ is flexible endoscope that allows operator-controlled deflection of the distal end or tip of the scope. The devices will be made available in lengths (25 cm and 65 cm), each length with a working channel. With a Maxi-Flex accessory a 'Y Port' the working channel may be utilized as an irrigation channel. - 6. Testing: Maxi-Flex Semi-Flex Scopes™ (this submission), for reuse has been tested for four (4) EtO sterilization cycles without any degradation from original design specifications. All other core elements of K062725 remain unchanged. - 7. Rx or OTC: The Maxi-Flex Semi-Flex Scopes™ is an Rx prescription device per 21 CFR Subpart D. The indication for use is for clinical setting only. - 8. Conclusions: The Maxi-Flex Semi-Flex Scopes™ is substantially equivalent to the predicate devices in the scope of practical application, effectiveness for this application, and ensuring the safety of its patient. This submission ad re-use to K062725. The Maxi-Flex Semi-Flex Scopes™ with four (4) reuse cycles does not raise any new safety or effectiveness issues. **MaxiFlex, LLC** Gary Ventrella Date: 03/3/12 1516 Thalia Street New Orleans, LA 70130 Phone: (504) 265-8972 Fax: (504) 265-8977 www.MaxiFiexLLC.com {2}------------------------------------------------ # DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it. The caduceus is positioned to the right of the text "DEPARTMENT OF HEALTH & HUMAN SERVICES · USA", which is arranged in a circular fashion around the symbol. The text is in all capital letters and is relatively small compared to the caduceus symbol. #### Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -W066-G609 Silver Spring, MD 20993-0002 Technology Delivery Systems, Inc. % Mr. James Harvey Knauss Contract Consultant Delphi Consulting Group 1516 Thalia Street NEW ORLEANS LA 70130 APR -4 2012 Re: K111480 Trade/Device Name: MaxiFlex - Semi Flex Scopes Regulation Number: 21 CFR§ 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: II Product Code: FGB Dated: March 21, 2012 Received: March 26, 2012 Dear Mr. Knauss: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use sunce in the encrease) to 10g.ing and ment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The 1 ou may, therefore, mains of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and actited , good manataotaning prace. 00, xx 10, xx 1 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = addition. Thease noter of That device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it your device is elassified (otto as to stime major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean Flease of advised that I Dr 3 555 and of the your device complies with other requirements of the Act that I Dri has made a acterimations administered by other Federal agencies. You must 01 any 1 cocrar studios and regulations, but not limited to: registration and listing Comply will an the Act 3 requirements) rr. 801); medical device reporting (reporting of medical {3}------------------------------------------------ Page 2 - device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, Sincerely yours, Benjamin K. Fisher Benjamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ #### Indications for Use Statement 510(k) Number: K111480 Device Name: MaxiFlex - Semi Flex Scopes #### Indications for Use: The MaxiFlex Semi Flex Scopes are intended to be used by trained medical professionals to examine the urinary tract, and using additional accessories, to perform various diagnostic and therapeutic procedures. Device may be re-used and re-sterilized by the EtO sterilization process up to 3 times Prescription Use YES (Part 21 CFR 801 Subpart D) AND/OR Over-The Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Hales (Division Sign-Off) Division of Reproductive, Gastro-Renal, an Urological Devices 510(k) Number. K111480 Section 4 510(k) Submission Page # ind for use form.doc Delphi Consulting Group Houston, TX 77071
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...