OSSEODUO, SHAVER HANDPIECE S80 AND S120, MICROMOTOR 80K
K083720 · Bien-Air Surgery SA · ERL · Mar 20, 2009 · Ear, Nose, Throat
Device Facts
Record ID
K083720
Device Name
OSSEODUO, SHAVER HANDPIECE S80 AND S120, MICROMOTOR 80K
Applicant
Bien-Air Surgery SA
Product Code
ERL · Ear, Nose, Throat
Decision Date
Mar 20, 2009
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 874.4250
Device Class
Class 2
Attributes
Therapeutic, Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K083720 · Mar 20, 2009
OSSEODUO, SHAVER HANDPIECE S80 AND S120, MICROMOTOR 80K
Bien-Air Surgery SA
Surgeon reports/feedback from clinical practice
Post-market clinical performance feedback from ENT surgeons in Italy, Switzerland, and China was used to support the safety and effectiveness of the device.
The OSSEODUO is a drill and shaver system that has been designed for drilling and shaping bone and for the resection of soft and hard tissues as part of surgical operations in the areas of otorhinolaryngology, otoneurology, maxillofacial surgery, and head and neck surgery. The shaver handpiece 580 or S120 is designed for cutting and removal of soft and hard tissue in the fields of: - Endoscopic sinus surgery (such as ethmoidectomy, polypectomy, septoplasty) , - Endoscopic dacryocystorhinostomy (DCR) । - Nasopharyngeal and laryngeal prodedures (such as adenoidectomy, polypectomy, tonsillectomy) - Head and neck surgery( such as acoustic-neuroma removal, tumor removal, rhinoplasty, adipose tissue removal, plastic, reconstructive and aesthetic surgery) The micromotor 80K combines with different drill and micro saw handpieces and is intended for cutting, drilling, shaping and sawing bone as part of various surgical procedures in the areas of ENT and head and neck surgery such as otoneurology, otorhinolaryngology and maxillofacial surgery (facial plastic, reconstructive and aesthetic surgery).
Device Story
OSSEODUO is an electric surgical drill and microdebrider system for ENT and maxillofacial procedures. System comprises a control unit with LCD, footswitch, irrigation pump, and interchangeable handpieces (S80/S120 shaver handpieces; 80K micromotor for drills/saws). Inputs include user-defined settings via control unit keys; outputs are mechanical rotation/oscillation of blades/burs. Operated by surgeons in clinical/OR settings. Shaver handpieces support continuous or oscillating modes; micromotor supports up to 80,000 rpm. Irrigation and suction are integrated into shaver blades/handpieces. Device provides precise tissue resection and bone shaping, aiding surgeons in complex ENT/head and neck surgeries. Benefits include improved surgical access and efficiency in tissue removal.
Clinical Evidence
No clinical data. Bench testing only: simulated tissue resection (oyster/scallop flesh, eggshell) and water aspiration trials compared OSSEODUO to predicate systems. Results confirmed equivalent tissue removal rates (grams/minute) and aspiration performance.
Technological Characteristics
Stainless steel construction; autoclavable. Electric motor drive; control unit with LCD and peristaltic irrigation pump. Shaver handpieces (S80/S120) and micromotor (80K) with ISO 3964 Type E coupling. Speed: 400-12,000 rpm (shaver), up to 80,000 rpm (drill). IPX8 waterproof footswitch. Sterile, single-use shaver blades/burs.
Indications for Use
Indicated for patients undergoing surgical procedures in otorhinolaryngology, otoneurology, maxillofacial, and head and neck surgery requiring drilling, shaping, or resection of bone and soft tissue. Includes endoscopic sinus surgery, DCR, nasopharyngeal/laryngeal procedures, and reconstructive/aesthetic surgery.
Regulatory Classification
Identification
An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that is intended to drive various accessories, such as an ear, nose, and throat bur (§ 874.4140), for the controlled incision or removal of bone in the ear, nose, and throat area.
Diego powered Dissector and Drill System (K020594)
Submission Summary (Full Text)
{0}------------------------------------------------
MAR 2 0 2009
Bien Air°
Surgery
# 510(k) Summary
Date prepared :
Made by :
Bien-Air Surgery SA Rue de l'Ouest 2b 2340 Le Noirmont Switzerland
3rd. December 2008
Submitter (contact):
Huques Froidevaux Quality and Regulatory Affairs Manager Bien-Air Surgery SA 2340 Le Noirmont Phone: +41 32 953 35 35 Fax: +41 32 953 35 37 huques.froidevaux@bienair.com Email:
## Device Name:
Proprietary name: Common names:
OSSEODUO Shaver and Drill System Electrical microresector, microdebrider; shaver Shaver blades, cannulae Electrical surgical drill, ENT drill, straight and angled handpieces, micro-saw handpieces Burs, saw blades
## Classification name:
OSSEODUO Shaver and Drill System:
Drill, surgical, ent (electric or pneumatic) including handpiece (21 CFR 874.4250, Product code ERL) Class II
Shaver blades, burs, rasps and saw blades:
Bur, Ear, Nose And Throat (21 CFR 874.4140, Product code EQJ) Class I
## Applicable 510(k) of predicate devices (substantial equivalence):
| Device | Manufacturer | FDA Clearance |
|---------------------------------------------|----------------------|---------------|
| XPS 3000 System | Medtronic Xomed Inc. | K041523 |
| Diego powered Dissector and Drill<br>System | Gyrus ENT L.L. | K020594 |
A member of the Bien-Air Group
{1}------------------------------------------------
μ083720
#### Device Description:
The OSSEODUO Shaver and Drill System consists of a control unit, a footswitch, connection cables, a shaver handpiece (also named microdebrider or microresector) to drive various shaver blades, a drill motor and assorted handpieces to drive various burs, drills, rasps and micro saw.
The control unit consists of a closed box with, on its main side, an LCD display screen and various function keys allowing the device to be adjusted according to the planned operation. On the right-hand side of the control unit are the connectors for the shaver handpiece S80 and for the micromotor 80K, while the pedal is connected on the rear panel. A peristaltic pump for irrigation and cooling is mounted on the rear panel which also contains the main power-up switch and the fuse holder.
The shaver handpiece includes a micromotor, a gear set, a coupling system for shaver blades and connections for irrigation. Through the control unit it can operate in oscillating modus (reversing after a user-defined number of turns in each direction) or in continuous CW and CCW rotation. Its made of stainless steel and autoclavable. The shaver handpiece is available in two version: the S80 being the basic model and the 5120 with higher rotation speed (up to 12'000 rpm in continuous rotation) and the ability to orient the shaver blade during operation without releasing the chucking mechanism.
The micromotor 80K has an ISO 3964 type E standard coupling which connects to a broad range of different handpieces, such as drill, contra-angle, saw, etc. Through the control unit it can achieve speeds of up to 80'000 rpm. All outer surfaces are made of stainless steel and the motor is autoclavable.
The footswitch allow a smooth progressive and continuous command of the shaver or drill speed. It is IPX8 waterproof.
#### Accessories:
Shaver blades are round elonqated stainless steel cutting instruments, with a small cutting window at the distal tip. At the proximal end a coupling part allow the mounting in the handpiece S80 or S120. The shaver blades have built in ways for irrigation and suction.
They are available in different diameters, with different geometries and different cutting edges. All shaver blades come in sterile packaging (ETO), most are disposable and for single use only. These accessories are designed to be used with the shaver handpiece S80 or S120 only.
Other accessories for the OSSEODUO System include burs, drills and saw blades, which are available sterile or non-sterile, as well as the irrigation lines to be used with the peristaltic pump of the control unit, which are disposable and sterile packaged.
{2}------------------------------------------------
**Intended use of the Device:**
The OSSEODUO is a drill and shaver system that has been designed for drilling and shaping bone and for the resection of soft and hard tissues as part of surgical operations in the areas of otorhinolaryngology, otoneurology, maxillofacial surgery, and head and neck surgery.
The shaver handpiece 580 or S120 is designed for cutting and removal of soft and hard tissue in the fields of:
- Endoscopic sinus surgery (such as ethmoidectomy, polypectomy, septoplasty) ,
- Endoscopic dacryocystorhinostomy (DCR) ।
- Nasopharyngeal and laryngeal prodedures (such as adenoidectomy, polypectomy, tonsillectomy)
- Head and neck surgery( such as acoustic-neuroma removal, tumor removal, rhinoplasty, adipose tissue removal, plastic, reconstructive and aesthetic surgery)
The micromotor 80K combines with different drill and micro saw handpieces and is intended for cutting, drilling, shaping and sawing bone as part of various surgical procedures in the areas of ENT and head and neck surgery such as otoneurology, otorhinolaryngology and maxillofacial surgery (facial plastic, reconstructive and aesthetic surgery).
The intended use of the OSSEODUO is substantially equivalent to that of the predicate devices.
| Characteristic | XPS 3000 Expanded Indications | Diego Dissector and Drill<br>System | OSSEODUO Shaver & Drill System |
|-----------------------------------|-------------------------------------------------------------------------------------------|---------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended Use | Cutting soft tissue and bone | Cutting soft tissue and<br>bone | Cutting soft tissue and bone |
| Driver configuration | Console with separate footswitch | Console with separate<br>footswitch | Console with separate footswitch |
| Energy source | Electric | Electric | Electric |
| Speed Indication | Digital | Digital | Digital |
| Fonctions | Drill and Microdebrider | Drill and Microdebrider | Drill and Microdebrider |
| Drill-Fonctions: | From 10'000 rpm to 80'000 rpm<br>Forward and reverse | Up to 44'000 rpm<br>Forward and reverse | From 4000 to 80'000 rpm<br>Forward and reverse |
| Peristaltic pumps | 2 pumps, 1 for irrigation and 1<br>optional pump for handpiece<br>cooling | 1 pump integrated into<br>console for irrigation | 1 pump integrated into console for<br>irrigation |
| Number of<br>Handpieces supported | 6:<br>StraightShot Magnum I or II,<br>Powerforma, Powersculpt, Skeeter,<br>Xcalibur drill | 4:<br>Diego, Stapes, Viper Drill<br>straight and angled | Unlimited: Shaver handpiece S80 or<br>S120, Drill Micromotor 80K with<br>standard ISO 3964 Type E coupling<br>which connects to a number of<br>different handpieces (straight,<br>angled, microsaw, etc). |
### Summary of technological characteristics:
{3}------------------------------------------------
| Microdebrider<br>Operating Modes | Forward, Reverse, Oscillate | Forward, Reverse, Oscillate | Forward, Reverse, Oscillate |
|-----------------------------------------------------------|-------------------------------------------------------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------|
| Microdebrider<br>(Microresector)<br>FWD / REV speed | Straightshot M4:<br>From 500 to 12'000 rpm.<br>Default: 6,000 rpm | Diego:<br>up to 15'000 rpm | Handpiece S120:<br>From 400 to 12'000 RPM<br>Default: 12'000 RPM<br>Handpiece 580:<br>From 400 to 8'000 RPM<br>Default: 8′000 RPM |
| Microdebrider<br>(Microresector)<br>Oscillation Speed | Straighshot M4:<br>From 500 to 5000 RPM<br>Default: 5,000 RPM | Diego:<br>Up to 5000 rpm | Handpiece S80 & S120:<br>From 300 to 5,000 RPM<br>Default: 3,500 RPM |
| Duty cycle at full load<br>oscillating: | Max 60s on<br>Min 30s off | Max 30s on<br>Min 1 minute 30s off | Max 3 min 30s on,<br>Min 6 min off |
| Steam autoclavable<br>handpieces | Yes | Yes | Yes |
| Blade sizes (O.D.) | 2.9 mm - 6 mm | 2.9 - 4.6mm | 3.0 mm - 4.0 mm |
| Suction Capability<br>(micro-debrider) | Yes suction port in line with shaver<br>blade, diameter 3.4mm | Yes suction port in line with<br>shaver blade | Yes suction port in line with shaver<br>blade, diameter 3.9mm |
| Irrigation Capability | Yes,<br>Irrigation port on the shaver blade. | Yes,<br>Irrigation port on the<br>handpiece | Yes<br>Irrigation port on the handpiece |
| Direct patient<br>contacting materials<br>(Burs / Blades) | Stainless Steel and medical<br>polymer | Stainless Steel and medical<br>polymer | Stainless Steel and medical<br>polymer |
| Blades / burs<br>biocompatible | Yes | Yes | Yes |
## Non clinical performance assessment
The substantial equivalence of the OSSEODUO to the Xomed XPS 3000 with Straightshot M4 and to the Gyrus Diego has been tested with various experiments.
Following trials have been conducted:
- i Resection of oyster-flesh mixed with eggshell to simulate the resection of cartilage.
- . Resection of scallops flesh
- । Aspiration of water
By each trial, following points have been watched: weight of removed tissues, frequency of the aspiration system.
{4}------------------------------------------------
K0863720
These experiments have confirmed that the OSSEODUO system has a similar rate of tissue removal (grams per minute) to the two reference systems. The aspiration of water with the same vacuum system has also shown equivalent results. Pertaining frequency of clogging, the results vary widely randomly from one measure to the other even with the same system so that comparison between systems are difficult.
These experiments have however clearly confirmed that the OSSEODUO system is equivalent in its function and capability to the predicate devices.
## Post Market Surveillance
As the OSSEODUO system has been CE-marked and cleared for market in Europe since October 2007, feedback of clinical performance of the OSSEODUO system has been reported by different ENT Surgeons from Italy, Switzerland and China.
Following topics have been addressed by the surgeons
- Cutting performance of the shaver blades compared to competition
- Suction/aspiration capability in shaver mode
- Drilling of bone at 40'000 rpm compared to competition
The different surgeon's reports confirm the effectiveness and safety of the OSSEODUO system
#### Conclusions
A comparison of technical features, non clinical testing with the predicate systems as well as post market performance feedback demonstrate that the OSSEODUO system is substantially as safe and effective as the predicate devices.
{5}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/5/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized emblem featuring a symbol that resembles an abstract caduceus or a stylized representation of human services.
## Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 2 0 2009
Bien Air Surgery SA c/o Hugues Froidevaux Quality & Regulatory Affairs Manager Rue de l'Ouest 2b Le Noirmont Switzerland 2340
Re: K083720
Trade/Device Name: OSSEODUO Shaver and Drill System Regulation Number: 21 CFR 874.4250 Regulation Name: Ear, nose, and throat electric or pneumatic surgical drill Regulatory Class: Class II Product Code: ERL Dated: February 3, 2009 Received: February 18, 2009
Dear Mr. Froidevaux:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{6}------------------------------------------------
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
M. B. Eglinton, mD
Malvina B. Eydelman, M.D. Director Division of Ophthalmic and Ear. Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
K083720
# Indications for Use
510(k) Number (if known): K083720
OSSEODUO, Shaver Handpiece S80 and S1.20, Micromotor 80K Device Name:
Indications for Use:
The OSSEODUO is a drill and shaver system that has been designed for drilling and shaping bone and for the resection of soft and hard tissues as part of surgical operations in the areas of otorhinolaryngology, otoneurology, maxillofacial surgery, and head and neck surgery.
The shaver handpiece S80 or S120 is designed for cutting and removal of soft and hard tissue in the fields of:
- Endoscopic sinus surgery (such as ethmoidectomy, polypectomy, septoplasty) -
- Endoscopic dacryocystorhinostomy (DCR) -
- Nasopharyngeal and laryngeal prodedures (such as adenoidectomy, polypectomy, tonsillectomy)
- Head and neck surgery( such as acoustic-neuroma removal, tumor removal, rhinoplasty, adipose tissue removal, plastic, reconstructive and aesthetic surgery)
The micromotor 80K combines with different drill and micro saw handpieces and is intended for cutting, drilling, shaping and sawing bone as part of various surgical procedures in the areas of ENT and head and neck surgery such as otoneurology, otorhinolaryngology and maxillofacial surgery (facial plastic, reconstructive and aesthetic surgery).
Prescription Use
(Per 21 CFR 801.109)
Prescription Use X (Part 21 CFR 801 Subpart D)
510(k) Number
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off)
Division of Ophthalmic and Ear,
Nose and Throat Devices
Page 1 of 1
BAS / HF /2009-01-27
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.