RICHARDS TOTAL/PARTIAL PROSTHESIS

K962564 · Gyrus Ent LLC · ETB · Jan 22, 1997 · Ear, Nose, Throat

Device Facts

Record IDK962564
Device NameRICHARDS TOTAL/PARTIAL PROSTHESIS
ApplicantGyrus Ent LLC
Product CodeETB · Ear, Nose, Throat
Decision DateJan 22, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 874.3450
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Richards Total/Partial Prosthesis is indicated for the total/partial reconstruction of the ossicular chain that has lost its function due to disease, trauma, or congenital defect.

Device Story

Prosthesis for middle ear ossicular chain reconstruction; replaces non-functional ossicles. Device features trimmable shaft and tiltable head for angulation against tympanic membrane. Used by ENT surgeons in clinical settings. Head composed of Hydroxylapatite; shaft composed of Plasti-Pore. Provides structural replacement to restore sound conduction.

Clinical Evidence

No clinical data provided; substantial equivalence based on design similarity and established material properties of Hydroxylapatite.

Technological Characteristics

Materials: Hydroxylapatite (head), Plasti-Pore (shaft). Design: Trimmable shaft, tiltable head for angulation. Classification: Total Ossicular Replacement Prosthesis (21 CFR 874.3450) and Partial Ossicular Replacement Prosthesis (21 CFR 874.3495).

Indications for Use

Indicated for patients requiring total or partial ossicular chain reconstruction due to disease, trauma, or congenital defects affecting middle ear function.

Regulatory Classification

Identification

A partial ossicular replacement prosthesis is a device intended to be implanted for the functional reconstruction of segments of the ossicular chain and facilitates the conduction of sound wave from the tympanic membrane to the inner ear. The device is made of materials such as stainless steel, tantalum, polytetrafluoroethylene, polyethylene, polytetrafluoroethylene with carbon fibers composite, absorbable gelatin material, porous polyethylene, or from a combination of these materials.

Predicate Devices

Submission Summary (Full Text)

{0} JAN 22 1997 Food and Drug Administration 510(k) Notification - Richards Total/Partial Prosthesis June 28, 1996 Smith & Nephew ENT Smith & Nephew Richards Inc. 2925 Appling Rd., Bartlett, TN 38133 Telephone: 901-373-0200 Toll Free: 800-262-3540 Fax: 901-373-0220 k962564 Smith & Nephew # 510(k) Summary of Safety and Effectiveness Trade Name: Richards Total/Partial Prosthesis Common Name: Partial Ossicular Replacement Prosthesis Classification Name: Total Ossicular Replacement Prosthesis (§ 874.3450) Total Ossicular Replacement Prosthesis (§ 874.3495) Official Contact: Ronald K. Smith Senior Regulatory Affairs Specialist Smith & Nephew ENT a division of Smith & Nephew Richards, Inc. 2925 Appling Road Bartlett, TN 38133 Telephone: (901) 373-0200 Telefax: (901) 373-0276 Date Prepared: June 28, 1996 The Richards Total/Partial Prosthesis is substantially equivalent to the Tilt-Top TORP and PORP marketed by Smith & Nephew ENT. These devices have the same indications for use, total/partial reconstruction of the ossicular chain that has lost its function due to disease, trauma, or congenital defect. The Richards Total/Partial Prosthesis and the predicate devices both have trimmable shafts made of Plasti-Pore and heads that may be tilted for proper angulation against the tympanic membrane. The head of the Richards Total/Partial Prosthesis is made from Hydroxylapatite, a widely accepted material for middle ear reconstruction. Differences between the Richards Total/Partial Prosthesis and the predicate device should not affect the safety or effectiveness. RS059601 RI RICHARDS
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...