TELEX IN-THE-EAR CUSTOM HEARING AID WITH THRESHOLD COMPRESSION-II

K964639 · Telex Communications, Inc. · ESD · Jan 21, 1997 · Ear, Nose, Throat

Device Facts

Record IDK964639
Device NameTELEX IN-THE-EAR CUSTOM HEARING AID WITH THRESHOLD COMPRESSION-II
ApplicantTelex Communications, Inc.
Product CodeESD · Ear, Nose, Throat
Decision DateJan 21, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 874.3300
Device ClassClass 1
AttributesTherapeutic

Indications for Use

to amplify and transmit sound to the ear.

Device Story

In-the-ear (ITE) custom hearing aid; amplifies and transmits sound to ear. Features threshold compression and 2-band compression (AC+). Assembled from standard industry components. Operated by patient; provides adjustable gain and frequency response. Controls include volume, low/high band gain, crossover frequency, threshold, loudness boost, and low-cut switch. Powered by standard hearing aid batteries (13, 312, 10A, or 5A). Assists patients with hearing impairment by adjusting dynamic range via 2-band compression.

Clinical Evidence

Bench testing only; compliance with ANSI S3.2-1987 standards for frequency response and technical specifications.

Technological Characteristics

ITE custom form factor; standard hearing aid components; ANSI S3.2-1987 compliant. Power: 13, 312, 10A, or 5A batteries. Features 2-band dynamic range compression amplifier. Manual controls: volume, gain, crossover, threshold, loudness boost, low-cut switch.

Indications for Use

Indicated for individuals requiring sound amplification to compensate for hearing loss.

Regulatory Classification

Identification

An air-conduction hearing aid is a wearable sound-amplifying device intended to compensate for impaired hearing that conducts sound to the ear through the air. An air-conduction hearing aid is subject to the requirements in § 800.30 or § 801.422 of this chapter, as applicable. The air-conduction hearing aid generic type excludes the group hearing aid or group auditory trainer, master hearing aid, and the tinnitus masker, regulated under §§ 874.3320, 874.3330, and 874.3400, respectively.

Predicate Devices

Submission Summary (Full Text)

{0} TELEX JAN 21 1997 Item C K964639 9600 Aldrich Avenue South Minneapolis, Minnesota 55420 USA Telephone 612-884-4051 (612) 884-0043 fax 510(K) SUMMARY Trade Name: Telex In-the-Ear Custom Hearing Aid with Threshold Compression II Common Name: Hearing Aid, ITE Classification Name: Air Conduction Hearing Aid, 77ESD Equivalent to: Telex Model 28A K922066 Description: Intended use: to amplify and transmit sound to the ear. Features: Threshold Compression, 2-band compression, AC+ Assembly: assembled from standard components that are widely used by other hearing aid manufacturers. Technical characteristics: technical specifications comply with S3.2-1987 ANSI standards. Fit: frequency response per S3.2-1987 ANSI standard as shown on specification filed with 510(k). Controls: Volume control, Low Band Gain (optional), High Band Gain (optional), Crossover Frequency (optional), Threshold Control, Loudness Boost (optional), Set-screw Volume Control (optional), Low cut Switch (optional) Power: Standard hearing aid battery (13, 312, 10A or 5A) Comparison to predicate device: identical to the model 28A, except for different amplifier which incorporates dynamic range compression in two bands as an optional compensation strategy. Submitted by: Tom Scheller Chief Engineer Hearing Instruments Group Telex Communications, Inc. 9600 Aldrich Ave S. Minneapolis, MN 55420 (612) 884-4051 voice (612) 884-0043 fax Contact: Tom Scheller Prepared: 15 November, 1996
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...