K171860 · Emergo Global Consulting, LLC · NXC · Jan 5, 2018 · Dental
Device Facts
Record ID
K171860
Device Name
Sureclear aligners
Applicant
Emergo Global Consulting, LLC
Product Code
NXC · Dental
Decision Date
Jan 5, 2018
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.5470
Device Class
Class 2
Attributes
Therapeutic, 3rd-Party Reviewed
Indications for Use
Sureclear™ aligners are indicated for the treatment of tooth malocclusion in patients with permanent dentition.
Device Story
Sureclear™ aligners are custom-fabricated, sequential orthodontic aligners made from clear thermoformed plastic. The system uses digital tooth scans and a dentist-provided prescription plan, processed via the Suresmile® System software (K002620). Technicians use the software to segment tooth data into individual models, interpret prescription instructions, and generate a sequence of intermediate tooth setups representing the treatment stages. Once the doctor approves the plan, aligners are manufactured and shipped. The aligners are worn by the patient for 20-22 hours daily, applying continuous gentle force to reposition teeth. The device is used in a clinical setting under the supervision of a dentist or orthodontist. The system benefits patients by providing a clear, removable alternative to traditional braces for correcting malocclusion.
Clinical Evidence
No clinical testing was performed. Substantial equivalence is supported by non-clinical performance data, including biocompatibility testing per ISO 10993-1 and established performance history of sequential aligners (product code NXC) since 1998.
Technological Characteristics
Sequential aligners fabricated via thermoforming of elastic thermoplastic materials. Biocompatibility per ISO 10993-1. Risk analysis per ISO 14971. Patient-specific dimensions. Software-driven treatment planning and modeling.
Indications for Use
Indicated for treatment of tooth malocclusion in patients with permanent dentition.
Regulatory Classification
Identification
An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services seal on the left and the FDA acronym followed by the full name of the agency on the right. The FDA part of the logo is in blue, with the acronym in a blue square and the rest of the name in a sans-serif font.
January 5, 2018
OraMetrix, Inc. % Mark Job Responsible Third Party Official Regulatory Technology Services, LLC. 1394 25th Street NW Buffalo, Minnesota 551313
Re: K171860
Trade/Device Name: Sureclear™ aligner system Regulation Number: 21 CFR 872.5470 Regulation Name: Orthodontic plastic bracket Regulatory Class: Class II Product Code: NXC Dated: December 27, 2017 Received: December 29, 2017
Dear Mark Job:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Mary S. Runner -S
For Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known)
Device Name sureclear™ aligners
Indications for Use (Describe)
Sureclear™ aligners are indicated for the treatment of tooth malocclusion in patients with permanent dentition.
Type of Use (Select one or both, as applicable)
X Prescription Use (Part 21 CFR 801 Subpart D)
| Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for Emergo. The logo consists of a red circle with three white curved lines inside, followed by the word "EMERGO" in black, uppercase letters. The font is sans-serif and the letters are evenly spaced.
# 510(k) Summary
## OraMetrix sureclear™ aligners
K
#### 5.1 Submission Sponsor
OraMetrix, Inc.
2350 Campbell Creek Blvd.
Suite 400
Richardson, TX 75082
USA
Phone number: 49-30-24309139
Contact: Sabrina Weitzel
Email: sabrina.weitzel@orametrix.de
#### 5.2 Submission Correspondent
Emergo Global Consulting, LLC
2500 Bee Cave Road, Bldg. 1, Suite 300
Austin, TX 78746
Office Phone: (512) 327-9997
Contact: Stuart R. Goldman, Senior Consultant, RA
Email: project.management@emergogroup.com
#### 5.3 Date Prepared
May 31, 2017
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for Emergo. The logo consists of a red circular icon with three curved white lines inside, followed by the word "EMERGO" in black, sans-serif font. The logo is simple and modern, with a focus on the company name.
#### 5.4 Device Identification
| Trade/Proprietary Name: | sureclear™ aligners |
|-------------------------|-----------------------------|
| Common/Usual Name: | Sequential aligners |
| Classification Name: | Orthodontic plastic bracket |
| Regulation Number: | NXC |
| Product Code: | 872.5470 |
| Device Class: | Class II |
| Classification Panel: | Dental |
#### 5.5 Legally Marketed Predicate Device
ClearCorrect System (K113618)
#### 5.6 Device Description
OraMetrix sureclear™ aligners are orthodontic aligners fabricated from a clear, thin thermoformed plastic in a sequential series, individually customized for each patient based on a doctor's prescription to progressively reposition the teeth via gentle, corrective forces in the upper and lower dental arches.
The patient's dentist or orthodontist will use a digital scanning system to capture the anatomy and locations of the patient's teeth, and then after evaluating those will fill out an electronic prescription form describing the treatment plan using OraMetrix's previously cleared Suresmile® System software (K002620). The digitally scanned tooth data and prescription form are sent electronically via the Suresmile System® to OraMetrix technicians, using the Suresmile® System, separate the tooth scan data into individual tooth models representing the patient's malocclusion.
Additional OraMetrix technicians, also using the Suresmile® System's software, interpret the doctor's instructions provided on the prescription form; produce a setup and a sequence of intermediate models corresponding to each stage of the patient's aligner therapy. The setup and the intermediate stages are sent, via the Suresmile® System, back to the doctor for review, modification or approval. Once the doctor is satisfied with the planned therapy, an order for the production, packaging and shipment of the aligners is made via the Suresmile® System.
#### 5.7 Indication for Use
Sureclear™ aligners are indicated for the treatment of tooth malocclusion in patients with permanent dentition.
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the logo for Emergo. The logo consists of a red circular icon with three curved white lines inside, followed by the word "EMERGO" in black, sans-serif font. The logo is simple and modern.
### 5.8 Substantial Equivalence Discussion
OraMetrix has chosen the ClearCorrect System cleared by the FDA under K113618 as the predicate device for its sureclear™ aligners. The following table compares the subject device to the predicate device with respect to their indications for use, technology and performance testing, thus demonstrating the basis for determination of substantial equivalence between these devices.
| Regulatory Information | | | |
|-----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|
| Device Name | Sureclear™ Aligners | ClearCorrect System | Similarities/<br>Differences |
| Manufacturer | OraMetrix, Inc. | ClearCorrect, Inc. | na |
| 510(k) | Pending | K113618 | na |
| Product Code | NXC | NXC | Same. |
| Regulation | §872.5470 | §872.5470 | Same. |
| Class | II | II | Same. |
| Indications for<br>Use | Sureclear™ aligners are indicated for<br>the treatment of tooth malocclusion<br>in patients with permanent dentition. | The ClearCorrect System is indicated for<br>the treatment of tooth malocclusion in<br>patients with permanent dentition (i.e.,<br>all second molars). The ClearCorrect<br>System positions teeth by way of<br>continuous gentle force. | Same. |
| Prescription use | Yes | Yes | Same. |
| Fundamental Scientific Technology | | | |
| Device Images | Image: Sureclear Aligners | Image: ClearCorrect Aligners | Similar. Varies<br>by patient<br>prescription. |
| Conditions of<br>Use | Worn daily by the patient for<br>approximately 20 to 22 hours, except<br>when performing dental hygiene and<br>eating and drinking. The treatment<br>plan (and time) varies by individual<br>patient prescription. | Worn daily by the patient for<br>approximately 20 to 22 hours, except<br>when performing dental hygiene and<br>eating and drinking. The treatment plan<br>(and time) varies by individual patient<br>prescription. | Same. |
#### Table 5-1 – Comparison of Characteristics
{6}------------------------------------------------
Image /page/6/Picture/1 description: The image shows the Emergo logo. The logo consists of a red circular icon with three curved white lines inside, followed by the word "EMERGO" in black, sans-serif font. The logo is simple and modern, with a focus on the company name.
| Mechanism of<br>Action | Sequential aligners are made from<br>elastic thermoplastic materials that<br>apply continuous gentle force to the<br>teeth. | Sequential aligners are made from<br>elastic thermoplastic materials that<br>apply continuous gentle force to the<br>teeth. | Same. |
|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------|----------|
| Material | Elastic thermoplastic material. | Elastic thermoplastic material. | Similar. |
| Sizes | Patient specific. | Patient specific. | Same. |
| Manufacturing<br>method | Thermoforming. | Thermoforming. | Similar. |
| Body Location | Mouth; mucosal membranes. | Mouth; mucosal membranes. | Same. |
| Relevant Testing Performed | | | |
| Biocompatibility<br>Testing | Per ISO 10993-1 and applicable parts. | Per ISO 10993-1 and applicable parts. | Similar. |
| Animal Testing | Not required and not performed. | Not required and not performed. | Same. |
| Clinical Testing | Not required and not performed. | Not required and not performed. | Same. |
| Risk Analysis | Per ISO 14971. | Assumed to have been performed. | Similar. |
### 5.9 Non-Clinical Performance Data
OraMetrix has submitted finished sureclear™ aligners for the appropriate biocompatibility testing per ISO 10993-1 and its applicable parts, while the physical and mechanical properties of the elastic thermoplastic materials used to fabricate the aligners have previously been demonstrated by the manufacturer of the base materials. The subject device meets all internal OraMetrix specification requirements to support substantial equivalence to the predicate device.
#### 5.10 Clinical Performance Data
The performance of sequential aligners in the clinical environment has been well established since the first such devices were cleared by the FDA in 1998 under product code NXC. Therefore, there was no clinical testing required to support sureclear™ aligners, as the indications for use is equivalent to the predicate device, which was not subjected to any clinical testing. The substantial equivalence of the subject device to the ClearCorrect System is supported by the non-clinical testing that was performed, along with other supporting documentation, and presented in this submission.
#### 5.11 Statement of Substantial Equivalence
Sureclear™ aligners have substantially equivalent Indications for Use as the identified predicate device. While the verbiage of the Indications of Use of the subject device is slightly different than the declared predicate; however, these slight differences do not alter the intended therapeutic use of the device as compared to the predicate device. The conclusions drawn from the data included in this submission,
{7}------------------------------------------------
Image /page/7/Picture/1 description: The image shows the logo for Emergo. The logo consists of a red circular icon with three curved lines inside, followed by the word "EMERGO" in black, sans-serif font. The logo is simple and modern, with a focus on the company name.
demonstrate that sureclear™ aligners are as safe, as effective, and are substantially equivalent to the predicate device in indications for use, design, technological characteristics, mechanism of action, performance, materials and biocompatibility.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.