VELSCOPE VX

K102083 · Led Dental, Inc. · NXV · Nov 18, 2010 · Dental

Device Facts

Record IDK102083
Device NameVELSCOPE VX
ApplicantLed Dental, Inc.
Product CodeNXV · Dental
Decision DateNov 18, 2010
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6350
Device ClassClass 2
AttributesReal-World Evidence

Real-World Evidence

SubmissionDeviceSponsorRWD SourcesRWE Use SummaryKey Tags
K102083 · Nov 18, 2010VELSCOPE VXLed Dental, Inc.Clinical photographs from oral medicine and oral dysplasia clinicsClinical photographs of various oral mucosal lesions were acquired using both the predicate device and the new device to demonstrate that the new device provides comparable visualization, supporting substantial equivalence.Oral mucosal lesions; Clinical photography; Substantial equivalence

Clinical Evidence

Study DesignPopulationComparatorKey Endpoints
Retrospective/Observational comparison of clinical imagesPatients referred to oral medicine and oral dysplasia clinics with oral mucosal lesionsPredicate device (VELscope, K070523)Comparison of fluorescence images between predicate and new device

Indications for Use

VELscope Vx is intended to be used by a dentist or health-care provider as an adjunct to traditional oral examination by incandescent light to enhance the visualization of oral mucosal abnormalities that may not be apparent or visible to the naked eye, such as oral cancer and premalignant dysplasia. VELscope Vx is further intended to be used by a surgeon to help identify diseased tissue around a clinically apparent lesion and thus aid in determining the appropriate margin for surgical excision.

Device Story

VELscope Vx is a natural tissue fluorescence visualization system used by dentists or surgeons as an adjunct to traditional oral exams. The device consists of a cordless handpiece containing a blue LED light source, viewing optics, and a rechargeable lithium-ion battery. The handpiece emits blue light (400-460nm) into the oral cavity, causing healthy tissue to fluoresce green; abnormal tissue appears as irregular, dark areas. The clinician views the tissue in real-time through the handpiece optics. This visualization aids in identifying mucosal abnormalities not visible to the naked eye and helps surgeons determine surgical margins for lesion excision. The device is used in clinical settings to improve detection of oral cancer and premalignant dysplasia.

Clinical Evidence

No clinical trials were conducted; evidence consists of comparative clinical photography. Photographs of various oral mucosal lesions were captured using both the predicate VELscope and the VELscope Vx under identical conditions. Comparison of these images supports the substantial equivalence of the devices. No adverse events or complications were reported.

Technological Characteristics

Handheld, cordless oral examination light. Excitation source: blue LED array (400-460nm). Power: rechargeable lithium-ion battery. Viewing optics: identical to predicate. Form factor: integrated handpiece with charging cradle. No software-based processing or connectivity.

Indications for Use

Indicated for use by dentists or healthcare providers as an adjunct to traditional oral exams to visualize oral mucosal abnormalities, including oral cancer and premalignant dysplasia, in patients requiring oral mucosal assessment. Also indicated for surgeons to identify diseased tissue margins around clinically apparent lesions.

Regulatory Classification

Identification

An ultraviolet detector is a device intended to provide a source of ultraviolet light which is used to identify otherwise invisible material, such as dental plaque, present in or on teeth.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ Image /page/0/Picture/0 description: The image contains a sequence of digits. The digits are '1102083'. The digits are written in a simple, sans-serif font and are evenly spaced. The image appears to be a close-up of the digits. ### 510(k) Summary # NOV 1 8 2010 Submitter's Name: David Morgan, PhD 235 - 5589 Byrne Road Address: Burnaby BC V5J 3J1 Canada (604) 434-4614, ext. 262 Phone: Date of Submission: July 23 2010 Contact Person: David Morgan, PhD E-mail: david.morgan@leddental.com (604) 434-4612 Fax: Device Name: VELscope Vx Common Name: Oral Examination Light Classification Name: Ultraviolet detector Marketed Device of Equivalence: VELscope (K070523) #### Description of Device: The VELscope Vx system is a natural tissue fluorescence direct visualization system to be used as an adjunctive tool for oral mucosal examination. The main components of VELscope are the Handpiece, incorporating light source, viewing optics and rechargeable battery. Charging Cradle and external power supply. The VELscope Handpiece emits a safe, visible, blue light into the oral cavity, which excites the oral tissue and causes it to fluoresce. The oral cavity can then be examined in real time and suspicious tissue that may require further investigation can be quickly identified. When viewed through the VELscope Handpiece, abnormal tissue typically appears as an irregular, dark area that stands out against the otherwise normal green fluorescence pattern of surrounding health tissue. #### Intended Use: VELscope Vx is intended to be used by a dentist or health-care provider as an adjunct to traditional oral examination by incandescent light to enhance the visualization of oral mucosal abnormalities that may not be apparent or visible to the naked eye, such as oral cancer and premalignant dysplasia. VELscope Vx is further intended to be used by a surgeon to help identify diseased tissue around a clinically apparent lesion and thus aid in determining the appropriate margin for surgical excision. {2}------------------------------------------------ ### Characteristics of VELscope compared to Predicate Device: As compared to the predicate device, the VELscope Vx system has identical Indications for Use. The main technological differences between the VELscope Vx and the predicate VELscope system are: - The light source has now been integrated into the Handpiece by replacing the . metal halide lamp originally situated in a separate Light Source Unit with a ring of blue light emitting diodes (LED's) now situated around the distal window of the Handpiece itself. - The VELscope Vx Handpiece can now operate in a completely cordless fashion . powered by a rechargeable lithium ion battery. The essential performance specifications of the device are equivalent to the predicate VELscope device: - The excitation band (400-460nm) is the same as the predicate device and the . optical output power in that excitation band is comparable. - . The emission (viewing) optics are identical to the predicate device. #### Non-Clinical Data Spectral data comparing the optical intensity distribution of the VELscope Vx excitation light with that of the predicate VELscope are provided to support substantial equivalence. #### Clinical Data Clinical photographs were taken of a variety of oral mucosal lesions from patients referred to oral medicine and oral dysplasia clinics. Conventional (white light) as well as fluorescence photographs using both the predicate VELscope and the VELscope Vx were acquired. No adverse events or complications were reported. A comparison of the predicate VELscope and VELscope Vx images supports the substantial equivalence of the VELscope Vx with the predicate VELscope. #### Conclusion The VELscope Vx system has identical indications for use as the predicate VELscope system and comparative excitation spectral data and clinical fluorescence photographs of oral mucosal lesions support the fact that, despite the technological differences, the VELscope Vx system is substantially equivalent to the VELscope system already cleared under 510(k) - K070523. {3}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo features the department's name in a circular arrangement around a symbol. The symbol consists of three stylized, curved lines that appear to be flowing or waving. #### Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 David Morgan, PhD Chief Science Officer LED Dental Incorporated 235-5589 Byrne Road Burnaby, BC Canada V5J 3J1 NOV 1 8 2010 Re: K102083 Trade/Device Name: VELscope Vx Regulation Number: 21 CFR 872.6350 Regulation Name: Ultraviolet Detector Regulatory Class: II Product Code: NXV Dated: October 18, 2010 Received: October-29, 2010 Dear Dr. Morgan: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice. labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {4}------------------------------------------------ #### Page 2- Dr. Morgan Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely vours. Nh for Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indications for Use 510(k) Number (if known): 10 2083 VELscope Vx Device Name: NOV 1 8 2010 Indications For Use: VELscope Vx is intended to be used by a dentist or health-care provider as an adjunct to traditional oral examination by incandescent light to enhance the visualization of oral mucosal abnormalities that may not be apparent or visible to the naked eye, such as oral cancer and premalignant dysplasia. VELscope Vx is further intended to be used by a surgeon to help identify diseased tissue around a clinically apparent lesion and thus aid in determining the appropriate margin for surgical excision. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Kure (Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices Page 1 of 510(k) Number: __
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...