JETSTREAM

K014252 · Deldent , Ltd. · KOJ · Feb 19, 2002 · Dental

Device Facts

Record IDK014252
Device NameJETSTREAM
ApplicantDeldent , Ltd.
Product CodeKOJ · Dental
Decision DateFeb 19, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6080
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The JETSTREAM airpolishing unit is intended to be used to remove stubborn stains, plaque and soft debris. Device applications: Routine polishing especially hard to reach areas, polishing prior to enamel etching and bonding techniques and prior to bonding orthodontic bands and brackets

Device Story

JetStream is an air-polishing unit used in dental clinics by dental professionals. Device utilizes pressurized air and water to deliver abrasive powder to tooth surfaces; removes stubborn stains, plaque, and soft debris. Used for routine cleaning and surface preparation before bonding procedures or orthodontic applications. Operates via connection to dental unit air/water supply. Benefits include efficient cleaning of hard-to-reach areas and improved surface readiness for dental adhesives.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Air-polishing unit; utilizes pressurized air/water and abrasive powder for dental prophylaxis. Form factor is a dental handpiece/unit attachment. No software or electronic components described.

Indications for Use

Indicated for dental patients requiring removal of stubborn stains, plaque, and soft debris, including routine polishing of hard-to-reach areas and surface preparation prior to enamel etching, bonding, or orthodontic bracket/band placement.

Regulatory Classification

Identification

An airbrush is an AC-powered device intended for use in conjunction with articulation paper. The device uses air-driven particles to roughen the surfaces of dental restorations. Uneven areas of the restorations are then identified by use of articulation paper.

Special Controls

The special control for this device is International Electrotechnical Commission's IEC 60601-1-AM2 (1995-03), Amendment 2, “Medical Electrical Equipment—Part 1: General Requirements for Safety.”

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 FEB 1 9 2002 Mr. Alan Edel Deldent Limited 19 Keren Kayemet Street Petach Tikvah, ISRAEL Re: K014252 Trade/Device Name: JetStream Regulation Number: 872.6080 Regulation Name: AirPolishing Unit Regulatory Class: II Product Code: KOJ Dated: November 27, 2001 Received: December 26, 2001 Dear Mr. Edel We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting vour device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. {1}------------------------------------------------ Page 2 - Mr. Edel You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613 . Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Tim M. A. Hultquist Timothy A. Ulatowski Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## LABELING Page 1 of 1 川华S2 2 510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________ Device Name: ____ JETSTREAM_ Indications for Use: The JETSTREAM airpolishing unit is intended to be used to remove stubborn stains, plaque and soft debris. Device applications: Routine polishing especially hard to reach areas, polishing prior to enamel etching and bonding techniques and prior to bonding orthodontic bands and brackets (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use Per 21 CFR801.109) OR Over-The-Counter Use (Optional Format 1-2-96) Sugar Plum "Thision Sign-Off) Ision of Dental, Infection Control, ି ଆଧାରୀ Hospital Devices Number_ KOJLIJAS
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...