WILLI GELLER CREATION ZI PORCELAIN

K043201 · Jensen Industries, Inc. · EIH · Jan 11, 2005 · Dental

Device Facts

Record IDK043201
Device NameWILLI GELLER CREATION ZI PORCELAIN
ApplicantJensen Industries, Inc.
Product CodeEIH · Dental
Decision DateJan 11, 2005
DecisionSESE
Submission TypeAbbreviated
Regulation21 CFR 872.6660
Device ClassClass 2

Indications for Use

Willi Geller Creation ZI Porcelain is a ceramic material intended for the veneering of zirconium oxide based cores and substructures to form dental restorations

Device Story

Willi Geller Creation ZI Porcelain is a dental ceramic material used by dental technicians in a laboratory setting. The material is applied as a veneer over zirconium oxide-based cores and substructures to create dental restorations. The device functions as a restorative material, providing the necessary mechanical and chemical properties to form durable dental prosthetics. It is intended for prescription use only.

Clinical Evidence

No clinical data; substantial equivalence is based on mechanical and chemical property testing.

Technological Characteristics

Dental porcelain powder for clinical use. Designed for veneering zirconium oxide-based cores. Class II device (Product Code EIH).

Indications for Use

Indicated for use by dental technicians to fabricate dental restorations by veneering zirconium oxide-based cores and substructures.

Regulatory Classification

Identification

Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ JAN, 11, 2005 K043201 ## Section E ## 510(k) SUMMARY | Submitted by: | Jensen Industries<br>50 Stillman Road<br>North Haven CT 06473<br>(203) 239-2090 phone<br>(203) 234-7176 fax<br>Contact: Gary Phelps | |------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------| | Date Prepared: | November 1, 2004 | | Device Name:<br>Common Name:<br>Classification:<br>Product Code: | Willi Geller Creation ZI Porcelain<br>Dental Porcelain<br>Class II<br>EIH | | Predicate Devices: | Willi Geller Creation& AV Porcelain: 510(k) number K002041<br>Lava Ceram: 510(k) number K011394* | ## Device Description Williw Geller Creation ZI porcelain is a dental ceramic that is used by dental technicians to fabricate dental restorations by veneering of zirconium oxide-based cores. Data has been presented to demonstrate that the mechanical properties, chemical qualities, and the indications for use make Willi Geller Creation ZI substantially equivalent to the predicate device Willi Geller Creation& AV Porcelain. The safety and effectiveness of Willi Geller Creation ZI , being determined by the chemical qualities and mechanical properties, is therefore equivalent to the predicate devices. * see page 10 {1}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular and contains the department's name in a ring around the outside. Inside the circle is an abstract symbol that resembles a stylized caduceus or a representation of human figures. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JAN 1 1 2005 Mr. Gary Phelps Quality Assurance Manager Jensen Industries, Incorporated 50 Stillman Road North Haven, Connecticut 06473 Re: K043201 Trade/Device Name: Willi Geller Creation ZI Porcelain Regulation Number: 872.6660 Regulation Name: Porcelain Powder for Clinical Use Regulatory Class: II Product Code: EIH Dated: October 12, 2004 Received: November 18, 2004 Dear Mr. Phelps: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {2}------------------------------------------------ Page 2 - Mr. Phelps Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements modifine in or any Federal statutes and regulations administered by other Federal agencies. of the Act of ally I oderal backed as a requirements, including, but not limited to: registration Tournust comply with an are reveling (21 CFR Part 801); good manufacturing practice alle listing (21 CFR Part 807), and lite systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) This letter wiff anon yourse Finding of substantial equivalence of your device to a premits clothed.com - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 - 11 your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), if you desire specific at Compliance at (301) 594-0115. Also, please note the regulation entitled "Misbranding by reference to premarket notification" (21CFR Part 807.97). You entition, "Therefinance al information on your responsibilities under the Act from the may obtain of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Owe Tillman, Liu, Ph.D. Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## Indications for Use 510(k) Number (if known): K043201 Device Name: Willi Geller Creation ZI Porcelain Indications for Use: Willi Geller Creation ZI Porcelain is a ceramic material intended for the veneering of zirconium oxide based cores and substructures to form dental restorations Prescription Use _____________________________________________________________________________________________________________________________________________________________ AND/OR (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF needed) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Runne (Division Sign-Off) Division of Anesthesiology, General Hospital, Infection Control, Dental Devices 510(k) Number: K04320 Page 1 of __
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...