ELIPAR TRILIGHT

K984247 · Espe Dental AG · EBZ · Feb 25, 1999 · Dental

Device Facts

Record IDK984247
Device NameELIPAR TRILIGHT
ApplicantEspe Dental AG
Product CodeEBZ · Dental
Decision DateFeb 25, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6070
Device ClassClass 2
AttributesTherapeutic

Intended Use

Activator for light-induced intraoral polymerization of resinous dental pit and fissure sealants, restorative materials, bondings, or luting materials

Device Story

ELIPAR® TRILIGHT is a light-curing unit used by dental professionals to polymerize (set) resinous dental materials. The device functions by transmitting light through a rod to the intraoral site. It is a development of the predicate ELIPAR® (VISIO®) unit, designed to provide improved handling and performance properties for the clinician. The device is used in a clinical setting to facilitate the hardening of sealants, restoratives, bondings, and luting materials, directly affecting the clinical workflow of dental restorations.

Clinical Evidence

No clinical data provided; substantial equivalence is based on technological characteristics and intended use compared to the predicate device.

Technological Characteristics

Light-curing unit for polymerization of dental resins. Utilizes a light source and transmission rod. Classified as an Ultraviolet Activator for Polymerization (21 C.F.R. § 872.6070).

Indications for Use

Indicated for light-induced intraoral polymerization of resinous dental pit and fissure sealants, restorative materials, bondings, or luting materials in dental patients.

Regulatory Classification

Identification

An ultraviolet activator for polymerization is a device that produces ultraviolet radiation intended to polymerize (set) resinous dental pit and fissure sealants or restorative materials by transmission of light through a rod.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ 2/25/99 ## 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS ll. Submitter | Name: | ESPE Dental AG | |-----------------|-------------------------------------------| | Street: | ESPE Platz | | ZIP-Code, City: | D-82229 Seefeld | | Federal State: | Bavaria | | Country: | Germany | | Contact: | Dr. Andreas Petermann, Regulatory Affairs | | Phone: | 011-49-8152-700395 | | Fax: | 011-49-8152-700869 | | E-mail: | Andreas_Petermann@ESPE.de | | Date: | 11/16/1998 | Name of Device | Proprietary Name: | ELIPAR® TRILIGHT | |----------------------|------------------------------------------| | Classification Name: | Ultraviolet Activator for Polymerization | | Common Name: | Light-Curing Unit | ## Predicate Device ELIPAR® (VISIO®) by ESPE .................(K803209) Description for the Premarket Notification ELIPAR® TRILIGHT is classified as an Ultraviolet Activator for Polymerization (21 C.F.R. § 872.6070) because it is a device intended to polymerize (set) resinous dental pit and fissure sealants or restorative materials by transmission of light through a rod. (Light-Curing Unit). ELIPAR® TRILIGHT has the same intended use and is substantially equivalent to ESPE's already 510(k) cleared light-curing unit ELIPAR® (VISIO®). Actually, the ELIPAR® TRILIGHT light source is a further development of the ELIPAR® (VISIO®) light source to provide the patient and user with more comfortable handling and more favorable properties. The Euror® (Visio®) light source is well established and determined to be safe and effective. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal is circular and contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized symbol that resembles a caduceus, a traditional symbol of medicine, but with a more abstract and modern design. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 FEB 2 5 1999 Dr. Andreas Petermann Regulatory Affairs ESPE Dental AG ESPE Platz D-82229 Seefeld Bavaria, Germany Re : K984247 Trade Name: Elipar® TriLight Regulatory Class: II Product Code: EBZ November 16, 1998 Dated: Received: November 27, 1998 Dear Dr. Petermann: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general The general controls controls provisions of the Act. provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical General regulation (21 CFR Part 820) and that, Devices: through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory In addition, FDA may publish further announcements action. concerning your device in the Federal Reqister. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 {2}------------------------------------------------ Page 2 - Dr. Petermann through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. -The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diaqnostic devices), please contact the Office of Compliance at (301) 594-4692. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours, Timothy A. Ulatowski Director Division of Dental, Infection Control, and General Hospital Devices Office of Device Evaluation Center for Devices and Radioloqical Health Enclosure {3}------------------------------------------------ ## STATEMENT OF INDICATIONS FOR USE III. Device Name: ELIPAR® TRILIGHT Indications for use: Activator for light-induced intraoral polymerization of resinous dental pit and fissure sealants, restorative materials, bondings, or luting materials 1 Susan Runner (Division Sign-Off) Division of Dental, Infection Control, and General Hospital Devices 198844 510(k) Number Prescription Use. (Per 21 CFR 801.109) Presci i (Per 21 Crk out. 109) 510(k) Elipar® Trilight
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...