MACH BRACKETS BRIGHT BRACKETS

K120471 · World Bio Tech Co., Ltd. · NJM · Jun 4, 2012 · Dental

Device Facts

Record IDK120471
Device NameMACH BRACKETS BRIGHT BRACKETS
ApplicantWorld Bio Tech Co., Ltd.
Product CodeNJM · Dental
Decision DateJun 4, 2012
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.5470
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The device is intended for orthodontic movement of teeth. It is used temporarily and is removed after orthodontic treatment has been completed. The devices are intended to be single used only.

Device Story

Mach Brackets/Bright Brackets are orthodontic ceramic brackets bonded to teeth to facilitate tooth movement. Input: mechanical force from flexible orthodontic arch wires. Operation: brackets are bonded to teeth; arch wires are threaded through self-ligating mechanism to apply steady, gentle pressure to teeth. Output: controlled orthodontic tooth movement. Used in clinical dental settings by orthodontists. Benefits: aesthetic appearance, self-ligating design for easier wire placement/removal, and improved bonding/debonding characteristics.

Clinical Evidence

Bench testing only. Biocompatibility testing performed per ISO 10993-5 (in vitro cytotoxicity) and ISO 10993-10 (oral mucous membrane irritation and skin sensitization). All tests passed.

Technological Characteristics

Material: 99.99% translucent polycrystalline aluminum oxide (Al2O3). Form factor: orthodontic bracket. Mechanism: self-ligating ceramic bracket bonded to teeth, utilizing arch wires for force application. Sterilization: not specified. Software: none.

Indications for Use

Indicated for orthodontic tooth movement in patients requiring orthodontic treatment. Single-use only.

Regulatory Classification

Identification

An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # K120471 : Device: Orthodontic Ceramic Bracket JUN - 4 2012 ## See 510(k) Summary, below. Trade Name: . MACH BRACKETS , BRIGHT BRACKETS 1. Common Name: Orthodontic Ceramic Bracket Classification Name: Bracket, Ceramic, Orthodontic, product code NJM Product Code: NJM Requlation: 872.5470 Class of device : Class II. - 1. The legally marketed device to which we are claiming equivalence: Orthodontic Ceramic brackets (K090933 ) ### 2. Description of device: The MACH BRACKETS are bonded to teeth to apply pressure to the tooth, transmitted through a flexible orthodontic wire, to alter the tooth position. The modified orthodontic ceramic bracket has both aesthetic and self-ligating qualities. The modifications were aimed at facilitating easier orthodontic wire placement and removal through self-ligation and enhancing the bonding and debonding characteristics of the bracket. - 3. Intended Use : The device is intended for orthodontic movement of teeth. It is used temporarily and is removed after orthodontic treatment has been completed. The devices are intended to be single used only. - 4. Technological Characteristics: The MACH BRACKETS is produced using Al2O3, translucent polycrystalline aluminum oxide (99.99%). This MACH BRACKETS are bonded to the teeth with commercially available materials and linked together by "arch wire" that applies steady, gentle produce desired tooth movement - 5. Performance: Bench tests were performed. | Test Items | | Test method | Tested by | Test results | |---------------------------|---------------------------------------------------------|-------------|----------------------------------------------------------------------------------------------|--------------| | Biocompatibility<br>Tests | In vitro cytotoxicity | ISO10993-5 | Dental Devices Testing<br>& Evaluation Center<br>Yeonsei University,<br>College of Dentistry | Passed | | | Oral mucous membrane irritation<br>test | ISO10993-10 | | Passed | | | BrdU' as a guideline for testing skin<br>sensiztization | ISO10993-10 | | Passed | Biocompatibility as follows; The tests demonstrated that the device is as safe, as effective and performs in a substantially equivalent manner to the predicate device. {1}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three tail feathers, representing the department's mission to protect the health of all Americans and provide essential human services. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA". ### Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 World Bio Tech Company, Limited C/O Mr. Peter Chung Correspondent 300 Atwood Street Pittsburgh, Pennsylvania 15213 JUN - 4 2012 Re: K120471 Trade/Device Name: Mach Brackets, Bright Brackets Regulation Number: 21 CFR 872.5470 Regulation Name: Orthodontic Plastic Bracket Regulatory Class: II Product Code: NJM Dated: April 28, 2012 Received: May 9, 2012 Dear Mr. Chung: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {2}------------------------------------------------ ### Page 2 - Mr. Chung Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If vou desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, for Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ #### Indications for Use Statement 4. ## Indications for Use 510(k) Number (if known): K 12 O 4 71 Device Name: Orthodontic Ceramic Bracket. Indications For Use: The device is intended for orthodontic movement of teeth. It is used temporarily and is removed affer orthodontic treatment has been completed. The devices are intended to be single used only. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Rumsey Page 1 of 1 (Division Sign-Off) (Division of Anesthesiology, General Hospital Infection Control, Dental Devices 510(k) Number: k120477
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...