ASEPTICO VCT VERSATILE COMMAND TECHNOLOGY MODEL AEU-925

K030163 · Aseptico, Inc. · EKX · Mar 3, 2003 · Dental

Device Facts

Record IDK030163
Device NameASEPTICO VCT VERSATILE COMMAND TECHNOLOGY MODEL AEU-925
ApplicantAseptico, Inc.
Product CodeEKX · Dental
Decision DateMar 3, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.4200
Device ClassClass 1
AttributesTherapeutic, 3rd-Party Reviewed

Indications for Use

Aseptico's AEU-925 VCT can be used for a wide range of dental procedures including; 1) Dental endodontic surgeries, such as drilling into the root canal. 2) General dentistry, such as removing carious material from the dentine. 3) Performing dental implant surgeries, such as perforating the bone, and tapping and threading procedures required before placement of implant prosthetics.

Device Story

AEU-925 VCT is a programmable dental system for controlling low-voltage dental motor speed, direction, and torque. Used in dental clinics by dentists; system manages endodontic and implant procedures. Inputs include operator-selected modes (Implant/Endodontic), foot control signals (water on/off, direction, preset scrolling), and voice commands for preset navigation. Device features built-in dynamometer for calibration, water pump for irrigation, and memory library for speed/torque settings to prevent file/implant overtightening. Connectivity to PC allows setting updates. Output is controlled motor operation; provides irrigation. Benefits include procedural precision and reduced risk of mechanical failure during endodontic/implant tasks.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Programmable digital control system for low-voltage dental motors. Features: built-in dynamometer for calibration, integrated water pump, foot control (AE-19), and autoclavable motor (AE-9A-30). Connectivity: PC interface for setting uploads. User interface: voice command support and preset memory library. Energy source: low-voltage electrical.

Indications for Use

Indicated for patients undergoing dental endodontic surgeries, general dentistry procedures (e.g., caries removal), and dental implant surgeries (e.g., bone perforation, tapping, threading).

Regulatory Classification

Identification

A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo for ASEPTICO International. The logo features a stylized swirl on the left, followed by the word "ASEPTICO" in a bold, shadowed font. Below "ASEPTICO" is the word "International" in a smaller, italicized font. To the right of the text is a faded image of a world map. Aseptico Inc. 8333 216th St SE Woodinville, WA 98072 Telephone 425.487.315 Fax 360 668-8722 www.aseptico.com grant@aseptico.com KO30163 ## 510(k) Summary MAR 0 3 2003 Grant Ramaley Contact: Date Prepared: September 16, 2002 Trade or Proprietary Name: Aseptico VCT Versatile Control Technology Model AEU-925 Classification Name: 872.4200 Dental Handpiece and Accessories ## Description of characteristics This programmable dental system digitally controls the speed, direction and torque of a low voltage dental motor. Each dental system has programmed into memory a library of speed and torque settings for commonly used Endodontic files and dental implants. The AEU-925 can also be programmed by the dentist to hold in memory six speed and torque settings that they prefer to use most. The speed and torque limiting features are intended to reduce overtightening of Endodontic files and dental implants. List of features: - 1) Stores speed and torque settings in its "Library" that can be recalled later - 2) Allows the operator to select the "mode" of operation from either "Implant" or "Endodontic" operation. - 3) Has a built in dynamometer to calibrate the handbiece, motor and console prior to use. - 4) Uses the autoclavable motor AE-9A-30. - 5) Has a built in water pump to provide irrigation - 6) Allows connectivity to a personal computer to upload new settings, - 7) Foot control AE-19 can be used to activate water on/off, change forward/reverse direction of the drill, scroll through various presets that are in the program menu, - 8) Allows the operator to use voice commands to step through library of preset speed and torque values. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. Inside the circle is a stylized symbol that resembles three abstract human figures or birds in flight, arranged in a layered, overlapping manner. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAR 0 3 2003 Aseptico, Incorporated C/O Mr. Charles Mack Responsible Third Party Official Underwriters Laboratories, Incorporated 2600 N. W. Lake Road Camas, Washington 98601-8542 Re: K030163 Trade/Device Name: Aseptico's AEU-925 VCT Versatile Command Technology Regulation Number: 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EKX Dated: February 13, 2003 Received: February 21, 203 Dear Mr. Mack: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {2}------------------------------------------------ Page 2 - Mr. Mack Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4613. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours. Susan Roman Susan Runner, DDS, MA Interim Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ Page of 510(k) Number K030163 Dental Handpiece and Accessories Device Name: Indications For Use: Aseptico's AEU-925 VCT can be used for a wide range of dental procedures including; 1) Dental endodontic surgeries, such as drilling into the root canal. 2) General dentistry, such as removing carious material from the dentine. 3) Performing dental implant surgeries, such as perforating the bone, and tapping and threading procedures required before placement of implant prosthetics. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use سمد (Per CFR 801.109) (Optional Format 1-2-96)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...