K022264 · Svenska Dental Instruments AB · EGS · Oct 2, 2002 · Dental
Device Facts
Record ID
K022264
Device Name
CLEAN 'N' OIL
Applicant
Svenska Dental Instruments AB
Product Code
EGS · Dental
Decision Date
Oct 2, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.4200
Device Class
Class 1
Intended Use
Clean'n'Oil is a maintenance spray for lubrication and cleaning of Turbines, Straight and Contra-Angled Handpieces, Air-Scalers and Air-Motors.
Device Story
Clean'n'Oil is a maintenance spray designed for dental clinical environments. It is used by dental professionals to lubricate and clean dental handpieces, including turbines, straight and contra-angled handpieces, air-scalers, and air-motors. The device functions as a mechanical maintenance tool to ensure proper operation and longevity of dental instruments. It does not involve electronic processing, software, or automated analysis.
Clinical Evidence
Bench testing only.
Technological Characteristics
Maintenance spray for dental handpieces. Mechanical lubrication and cleaning agent. No electronic components, software, or energy source.
Indications for Use
Indicated for the lubrication and cleaning of dental handpieces, including turbines, straight and contra-angled handpieces, air-scalers, and air-motors.
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
Related Devices
K070297 — CLEARVIEW DENTAL HANDPIECE LUBRICATOR AND LUBRICANT · Dental Air Solutions of Nc, Inc. · Feb 5, 2007
K062418 — K-SPRAY, MODEL 085-2715 · Scican · Oct 19, 2006
K052700 — PANA-SPRAY · Nsk America Corp. · Dec 20, 2005
K070074 — LUBRINA, MODEL HIM-1 · J. Morita USA, Inc. · May 31, 2007
K113674 — SPRAY & CLEAN HANDPIECE CLEANER& LUBRICANT MAXIMA HANDPIECE CLEANER & LUBRICANT EZCARE HANDPIECE CLEANER & LUBRICANT · Handpiece Headquarters, Inc. - Hpr, Inc. · Apr 5, 2012
Submission Summary (Full Text)
{0}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular, with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. In the center of the seal is a stylized image of an eagle with three lines extending from its head.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
# OCT 0 2 2002
Ms. Emma Bergquist Product and Quality Co-Ordinator Svenska Dental Instruments AB Finvids väg 8 P.O. Box 723 SE-194 27 Upplands Väsby SWEDEN
Re: K022264
Trade/Device Name: Clean 'n' Oil Regulation Number: 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EGS Dated: July 1, 2002 Received: July 12, 2002
Dear Ms. Bergquist:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting vour device can be found in the Code of Federal Regulations, Title 21. Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Page 2 – Ms. Bergquist
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies.
You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus. permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613 . Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.qov/cdrh/dsma/dsmamain.html
Sincerely yours
Timothy A. Ulatowski Director Division of Anesthesiology, General Hospital. Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
{2}------------------------------------------------
5 10(k) | Jumbe :
## K022264
Clean'n'Oil
[Jevice Name:
Indicati ans Fo · Use:
Clean'n'Oil is a maintenance spray for lubrication and cleaning of Turbines, Straight and Contra-Angled Handpieces, Air-Scalers and Air-Motors.
(PLE ASE DO NOT WRITE BELOW THIS LINE -- CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off)
Division of Anesthesiology, General Hospital,
Infection Control, Dental Devices
510(k) Number: K033064
> Pre :criptio \ Use: _ (Pe 21CFIR 801.109)
Over -the-Counter Use: __
(Optional format 1-2-96)
### Svonska Dental Instrument AB
P.C. Box 723 SE 194 27 Upplands Väsby SW EDEN
Phone No +46-8-506 505 75 +46-8-506 505 83 Direct line E-mail order and information E-mail Web site
OR
+46-8-590 306 30 Telefax No VAT-No SE556013882701 info@sdidirecta.com emma.bergquist@sdidirecta.com www.sdidirecta.com
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.