BONE BLOCK FIXATION SET

K050515 · Straumann USA, Inc. · DZL · Apr 5, 2005 · Dental

Device Facts

Record IDK050515
Device NameBONE BLOCK FIXATION SET
ApplicantStraumann USA, Inc.
Product CodeDZL · Dental
Decision DateApr 5, 2005
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 872.4880
Device ClassClass 2
AttributesTherapeutic

Intended Use

Straumann Bone Block Fixation is used to stabilize and fixate bone grafts and bone filling materials for the regeneration of bone in the oral cavity. The bone grafting fixation technique can make it possible for the placement of dental implants in previously unsuitable sites.

Device Story

Straumann Bone Block Fixation Set consists of a cassette, surgical instruments, and screws; used by dental surgeons in clinical settings to stabilize bone grafts or filling materials during oral bone regeneration procedures. Device enables subsequent dental implant placement in sites previously unsuitable due to bone deficiency. Screws are composed of CP Grade 4 titanium. Operation is manual; surgeon uses instruments to fixate graft material to the patient's jawbone. Output is mechanical stabilization of graft material. Benefits include improved site conditions for dental implant integration.

Clinical Evidence

No clinical data; bench testing only.

Technological Characteristics

Materials: CP Grade 4 titanium screws. Components: Cassette, instruments, and screws. Dimensions modified from predicate. Manual surgical instrumentation. No energy source. Non-software device.

Indications for Use

Indicated for stabilization and fixation of bone grafts and bone filling materials for bone regeneration in the oral cavity to facilitate dental implant placement.

Regulatory Classification

Identification

An intraosseous fixation screw or wire is a metal device intended to be inserted into fractured jaw bone segments to prevent their movement.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # ATTACHMENT 7 ## 510(k) Summary ### 1 . Applicant's Name and Address Straumann USA (on behalf of Institut Straumann AG) Reservoir Place 1601 Trapelo Road Waltham, MA 02451 Telephone Number: 781-890-0001 781-890-6464 Fax Number: Contact Person: Linda Jalbert Vice President, Regulatory & Clinical Affairs ### 2. Name of the Device Trade Name: Common Name: Classification Name: Straumann Bone Block Fixation Set Bone Block Fixation Set Bone Block Fixation Set 21 CFR 872.4880 ## 3. Legally Marketed Devices to which Equivalence is Claimed (Predicate Devices) Guided Bone Regeneration System (K011698) ## Description of the Device 4. Straumann Bone Block Fixation includes a cassette, instruments, and screws that are slight modifications of ones previously cleared by FDA under K011698. Modification to the instruments and screws are in dimensions only. #### 5. Intended Use of the Device Like the predicate device, the Straumann Bone Block Fixation Set is intended for stabilizing and fixating bone grafts and bone filling materials for the regeneration of bone in the oral cavity. {1}------------------------------------------------ ## Basis for Substantial Equivalence ర. The Straumann Bone Block Fixation Set is substantially equivalent to the previously cleared Straumann Guided Bone Regeneration (GBR) System. The intended use is the same. The screws and instruments are similar, and in some cases identical, to the previously cleared GBR System screws and instruments. The screws are composed of CP Grade 4 titanium, which is identical to the previously cleared GBR System screws. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or bird in flight, composed of three curved lines. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 APR 5 2005 Ms. Linda Jalbert Vice President, Regulatory and Clinical Affairs Straumann USA, Incorporated 1601 Trapelo Road Waltham, Massachusetts 02451 Re: K050515 Trade/Device Name: Bone Block Fixation Set Regulation Number: 21 CFR 872.4880 Regulation Name: Intraosseous Fixation Screw or Wire Regulatory Class: II Product Code: DZL Dated: March 18, 2005 Received: March 21, 2005 Dear Ms. Jalbert: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Ms. Jalbert Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Anthony D. Winter for Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ ## Indications for Use 510(k) Number (if known): K050515 Bone Block Fixation Set Device Name: Indications for Use: Straumann Bone Block Fixation is used to stabilize and fixate bone grafts and bone filling materials for the regeneration of bone in the oral cavity. The bone grafting fixation technique can make it possible for the placement of dental implants in previously unsuitable sites. X AND/OR Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Inner 1120 i Islon (Sign-Off) Page 1 of 1 ം : !slon Sign-Old mileotion Control. Dental Devices Number. K0R755 Straumann Bone Block Fixation December 20, 2004 Page 1 of l
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...