GRANDIO SO FLOW

K103580 · Voco GmbH · EBF · Jan 21, 2011 · Dental

Device Facts

Record IDK103580
Device NameGRANDIO SO FLOW
ApplicantVoco GmbH
Product CodeEBF · Dental
Decision DateJan 21, 2011
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 872.3690
Device ClassClass 2
AttributesTherapeutic

Intended Use

Grandio SO Flow is intended for use as: - filling minimally invasive cavities of all classes - - filling small class I cavities and extended fissure sealing - - filling class II V cavities including V-shaped defects and cervical caries - - blocking out undercuts - - lining or coating cavities . - repairing fillings and veneers - - luting translucent prosthetic pieces (e.g., full ceramic crowns, etc.)

Device Story

Grandio SO Flow is a light-cured, flowable, radiopaque, nano-hybrid resin-based restorative material. Used by dental professionals in clinical settings for direct restorative procedures and luting of translucent prosthetics. Material is applied to prepared tooth surfaces or prosthetic restorations and cured using a dental curing light. Provides structural support, aesthetic restoration, and sealing of dental cavities or defects. Benefits include improved handling for minimally invasive procedures and versatility in restorative applications.

Clinical Evidence

Bench testing only.

Technological Characteristics

Nano-hybrid resin-based restorative material; light-cured; flowable consistency; radiopaque. Formulated for dental cavity restoration and luting. No specific ASTM standards or software components identified.

Indications for Use

Indicated for dental restorative procedures including filling minimally invasive cavities (all classes), small class I cavities, extended fissure sealing, class II-V cavities (including V-shaped defects and cervical caries), blocking out undercuts, lining/coating cavities, repairing fillings/veneers, and luting translucent prosthetic pieces.

Regulatory Classification

Identification

Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl methacrylate (Bis-GMA) intended to restore carious lesions or structural defects in teeth.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/0/Picture/1 description: The image contains the text "Public Health Service". The text is in a simple, sans-serif font and is left-aligned. The text is likely part of a document or sign. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room-WO66-G609 Silver Spring, MD 20993-0002 Mr. Manfred Thomas Plaumann Managing Board Voco GMBH Anton-Flettner-Strasse 1-3 Germany D-27472 JAN 2 1 201 Re: K103580 Trade/Device Name: Grandio SO Flow Regulation Number: 21 CFR 872.3690 Regulation Name: Tooth Shade Resin Material Regulatory Class: II Product Code: EBF Dated: December 17, 2010 Received: December 22, 2010 Dear Mr. Plaumann: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Page 2- Mr. Plaumann Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, Jh for Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use Statement 510(k) Number: _ K10 3580 Device Name: Grandio SO Flow Indications for Use: Grandio SO Flow is intended for use as: - filling minimally invasive cavities of all classes - - filling small class I cavities and extended fissure sealing - - filling class II V cavities including V-shaped defects and cervical caries - - blocking out undercuts - - lining or coating cavities . - repairing fillings and veneers - - luting translucent prosthetic pieces (e.g., full ceramic crowns, etc.) Prescription Use X OR Over-The-Counter Use (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Runo (Division Sign-Off) (Division Sign-On) Infection Control, Dental Devices 510(k) Number:
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...